• Title/Summary/Keyword: Simplified Assessment

Search Result 262, Processing Time 0.029 seconds

Simplified elastic-plastic analysis procedure for strain-based fatigue assessment of nuclear safety class 1 components under severe seismic loads

  • Kim, Jong-Sung;Kim, Jun-Young
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2918-2927
    • /
    • 2020
  • This paper proposes a simplified elastic-plastic analysis procedure using the penalty factors presented in the Code Case N-779 for strain-based fatigue assessment of nuclear safety class 1 components under severe seismic loads such as safety shutdown earthquake and beyond design-basis earthquake. First, a simplified elastic-plastic analysis procedure for strain-based fatigue assessment of nuclear safety class 1 components under the severe seismic loads was proposed based on the analysis result for the simplified elastic-plastic analysis procedure in the Code Case N-779 and the stress categories corresponding to normal operation and seismic loads. Second, total strain amplitude was calculated directly by performing finite element cyclic elastic-plastic seismic analysis for a hot leg nozzle in pressurizer surge line subject to combined loading including deadweight, pressure, seismic inertia load, and seismic anchor motion, as well as was derived indirectly by applying the proposed analysis procedure to the finite element elastic stress analysis result for each load. Third, strain-based fatigue assessment was implemented by applying the strain-based fatigue acceptance criteria in the ASME B&PV Code, Sec. III, Subsec. NB, Article NB-3200 and by using the total strain amplitude values calculated. Last, the total strain amplitude and the fatigue assessment result corresponding to the simplified elastic-plastic analysis were compared with those using the finite element elastic-plastic seismic analysis results. As a result of the comparison, it was identified that the proposed analysis procedure can derive reasonable and conservative results.

Assessment of pushover-based method to a building with bidirectional setback

  • Fujii, Kenji
    • Earthquakes and Structures
    • /
    • v.11 no.3
    • /
    • pp.421-443
    • /
    • 2016
  • When conducting seismic assessment of an asymmetric building, it is essential to carry out three-dimensional analysis considering all the possible directions of seismic input. For this purpose, the author proposed a simplified procedure is to predict the largest peak seismic response of an asymmetric building subjected to horizontal bidirectional ground motion acting in an arbitrary angle of incidence in previous study. This simplified procedure has been applied to torsionally stiff (TS) asymmetric buildings with regular elevation. However, the suitability of this procedure to estimate the peak response of an asymmetric building with vertical irregularity, such as an asymmetric building with setback, has not been assessed. In this article, the pushover-based simplified procedure is applied to estimate the peak response of asymmetric buildings with bidirectional setback. Nonlinear dynamic (time-history) analysis of two six-storey asymmetric buildings with bidirectional setback and designed according to strong-column weak beam concept is carried out considering various directions of seismic input, and the results compared with those estimated by the proposed method. The largest peak displacement estimated by the simplified method agrees well with the envelope of the dynamic analysis response. The suitability assessment of the simplified procedure to analysed building models is made as well based on pushover analysis results.

Progress of the 2013 Interim Guidelines for Determining Minimum Propulsion Power to Maintain the Manoeuvrability of Ships in Adverse Conditions (황천 시 최소추진출력 관련 IMO 잠정 가이드라인의 진행 현황과 적용 결과 검토)

  • Sung, Young Jae;Ock, Yu Bin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.6
    • /
    • pp.497-506
    • /
    • 2019
  • Literature survey was conducted on the 2013 Interim Guidelines for determining the minimum propulsion power to maintain the manoeuvrability of ships in adverse conditions. The International Maritime Organization (IMO) Marine Environment Protection Committee (MEPC) documents related with the Guidelines were reviewed. Compatibility of the present Guidelines can be checked by two different levels: (Level 1) minimum power lines assessment and (Level 2) simplified assessment. The IHS (Information Handling Services) sea-web data on the bulk carriers and the tankers, which were built after 2000, were used to examine the Level 1 assessment. KVLCC2 was used to examine the Level 2 assessment. Regarding the Level 2 assessment, effects of the adverse weather conditions, the added resistance due to waves, the wake fractions and the thrust deduction factors were discussed.

Simplified methods for seismic assessment of existing buildings

  • Tehranizadeh, Mohsen;Amirmojahedi, Maryam;Moshref, Amir
    • Earthquakes and Structures
    • /
    • v.10 no.6
    • /
    • pp.1405-1428
    • /
    • 2016
  • Besides the complex instructions of guidance documents for seismic rehabilitation of existing buildings, some institutions have provided simple criteria in terms of simplified rehabilitations. ASCE 41-06 is one of documents that introduced a simple method for assessment of certain buildings that do not require advanced analytical procedures. Furthermore the New Zealand guideline has presented a simple lateral mechanism analysis that is a hand static analysis for determining the probable collapse mechanism, lateral strength and displacement capacity of the structure. The present study is focused on verifying the results of the simplified methods which is used by NZSEE and ASCE 41-06 in assessment of existing buildings. For this, three different special steel moment and braced frames are assessed under these two guidelines and the accuracy of the results is checked with the results of nonlinear static and dynamic analysis. After comparison of obtained results, suggestions are presented to improve seismic retrofit criteria.

Development of Simplified Collision and Grounding Strength Assessment System of Oil Tankers (유조선의 간이 충돌/좌초강도 평가시스템 개발)

  • Lee T.K.;Kim J.D.;Chun T.B.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.2 no.2
    • /
    • pp.86-94
    • /
    • 1999
  • This paper describes a development of Collision/grounding Strength Assessment System (COSAS) using simplified method. This method is formulated in closed-form equation by taking into account crushing caused by bulbous bow collision and cutting caused by forward speed grounding. To verify the accuracy of the developed system, some examples for test models of double side/bottom structure in collision/grounding situation are considered. This system might be useful for analysis of structural damage of oil tankers in collision/grounding.

  • PDF

Evaluation of environmental impacts for the bogie of electric motor unit(EMU) using simplified life cycle assessment(S-LCA) (간략화된 전과정 평가를 이용한 전동차 대차의 환경영향 진단)

  • Kim Yong-Ki;Yoon Hee-Teak;Yang Yun-Hee;Lee Jae-Young
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.6 s.31
    • /
    • pp.581-585
    • /
    • 2005
  • In this study, the environmental impacts of a bogie in the electric motor unit(EMU) were evaluated quantitatively using simplified life cycle assessment(S_LCA). Target was the bogie and life cycle inventory(LCI) database for the bogie was established. The software used for simplified LCA was PASS. Environmental impacts with the parts of the bogie were dependent on their weight significantly. Among impact categories, abiotic resource depletion(ARD) and global warming(GW) were shown dominantly. Global warming was occurred mainly due to the emission of CO₂released from energy consumption and abiotic resource depletion was caused mostly by the consumption of iron ore for the manufacturing of steel. Therefore, the environmental impacts of the bogie could be reduced by the light-weighting of EMU and the improvement of energy efficiency.

Lightning Risk Assessment for Structures Lower than 20m High (높이 20미터 미만인 구조물의 낙뢰리스크 평가)

  • Lee, Ju-Chul;Kim, Gi-Hyun;Lee, Young-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.21-27
    • /
    • 2012
  • Korean Industrial Standards for lightning protection system complies with IEC standards. However, the standards are applicable only to buildings and structures more than 20 meters in high. Therefore, it is necessary to determine whether lightning protection system should be installed on structures lower than 20 meters high. This paper proposes an efficient method of assessing risk against lightning of structures lower than 20 meters high. The method suggests simplified lightning protection system and provides selecting an appropriate protection level. The suggested method assumes that structure under assessment has no lightning protection system and there is no person around the structure at the moment of lightning stroke. A simplified method of assessing the risk to human within the structure is developed by adopting the general assessment factor. The selection of a protection level is possible by comparing tolerable risk with physical damage risk caused by a direct lightning. Finally, this paper gives ways to establish surge protection measures when a structure with lightning risk is within a radius of 2km from the assessed structure even if this structure requires no lightning protection system.

Demonstration of the Effectiveness of Monte Carlo-Based Data Sets with the Simplified Approach for Shielding Design of a Laboratory with the Therapeutic Level Proton Beam

  • Lai, Bo-Lun;Chang, Szu-Li;Sheu, Rong-Jiun
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.50-57
    • /
    • 2022
  • Background: There are several proton therapy facilities in operation or planned in Taiwan, and these facilities are anticipated to not only treat cancer but also provide beam services to the industry or academia. The simplified approach based on the Monte Carlo-based data sets (source terms and attenuation lengths) with the point-source line-of-sight approximation is friendly in the design stage of the proton therapy facilities because it is intuitive and easy to use. The purpose of this study is to expand the Monte Carlo-based data sets to allow the simplified approach to cover the application of proton beams more widely. Materials and Methods: In this work, the MCNP6 Monte Carlo code was used in three simulations to achieve the purpose, including the neutron yield calculation, Monte Carlo-based data sets generation, and dose assessment in simple cases to demonstrate the effectiveness of the generated data sets. Results and Discussion: The consistent comparison of the simplified approach and Monte Carlo simulation results show the effectiveness and advantage of applying the data set to a quick shielding design and conservative dose assessment for proton therapy facilities. Conclusion: This study has expanded the existing Monte Carlo-based data set to allow the simplified approach method to be used for dose assessment or shielding design for beam services in proton therapy facilities. It should be noted that the default model of the MCNP6 is no longer the Bertini model but the CEM (cascade-exciton model), therefore, the results of the simplified approach will be more conservative when it was used to do the double confirmation of the final shielding design.

A Study on the Applicability of Arias Intensity Liquefaction Assessment (Arias Intensity 액상화 평가기법의 적용성에 관한 연구)

  • Hwang, Jungtae;Lee, Jongkeun;Shin, Eunchul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.6
    • /
    • pp.13-19
    • /
    • 2013
  • In this study, the target ground was selected for the assessment of liquefaction, for which energy-based Arias intensity liquefaction assessment method was applied, The results of evaluation by simplified method using conventional in-situ test were compared. The result of the assessment of liquefaction revealed that the safety factor of the Arias Intensity using the actual records of the Hachinohe and Ofunato earthquake showed generally similar trends with the simplified method, However, the Arias Intensity factor of safety for the artificial earthquake created from the design response spectrum showed some difference from the factors of safety of the simplified method. The shear stress ratio and the occurrence strength of the Arias Intensity are differently calculated between stress and energy, but the resistance stress ratio of the simplified method and the resistance strength of the Arias Intensity use the empirical chart of the results of the standard penetration test for the actual liquefaction areas by the earthquake, which seems the reason for the similar results between Arias Intensity assessment and stress concept simplified method for Hachinohe and Ofunato earthquakes. Therefore, it was found that the energy-based Arias Intensity liquefaction assessment could represent the dynamic changes of the ground caused by seismic characteristics such as acceleration, magnitude, duration and amplitude.

The Assessment Guideline of the Simplified Test Maturity Model (TMM) for An Assessor (심사원을 위한 경량화 테스트 성숙도 모델을 위한 평가 가이드 연구)

  • Jang, Woo Sung;Kim, Ki Du;Son, Hyun Seung;Park, Bo Kyung;Kim, R. Young Chul
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.8
    • /
    • pp.379-384
    • /
    • 2017
  • In real software business environment, there are required to validate software quality in diverse usage range of software for many small & medium companies. Software quality means both qualities of production and process. In our situation, we focus on better process quality of a test organization than a whole organization. But even the original test maturity model (TMM) does not enough to apply with our domestic venture/small & medium companies. To solve this problem, we suggest the simplified test maturity model for our companies. We redefine this simplified model with the original TMM and a test process improvement next (TPI next) model. The previous models just have provided each definition of maturity level, goal and activity per each level, which not exists an assessment guideline and a formal assessing procedure. Due to this reasons, an assessor is difficult to assess the test organization without them. this paper suggest an assessment guideline of the simplified TMM and also define the procedure which is included with activities and byproducts. With these assessment guideline, an assessor can work possible to formally assess test organizations of small & medium companies, and with self assessment guideline they can be correctly provision before assessment of their organizations.