• Title/Summary/Keyword: Simple standard deviation

Search Result 250, Processing Time 0.024 seconds

The influence of mileage program on brand loyalty of the apparel firm (의류업의 마일리지 제도가 브랜드 충성도에 미치는 영향)

  • 오경화;심혜연;홍병숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.3_4
    • /
    • pp.384-394
    • /
    • 2003
  • The purpose of this research is to provide the apparel companies with a successful business strategy by analyzing the concept, function and current status of mileage programs; and examining how customer's attitude, recognition, experience, compensation method of the mileage program in apparel companies affect its brand loyalty. In this research simple random sampling was performed. The sample pool was based on 494 people which included college students and employed men and women in their twenties and thirties living in Seoul and in the metropolitan area. The data analysis was completed on the basis of SPSS package, using frequency, percentage, mean, standard deviation, factor analysis, variation, Scheffe test, regression, t-test, and X/sup2/. The following results were found in this research: It is effective to maintain brand loyalty through continuous relationship with consumers as fierce competition increases in apparel companies. A mileage program is a win/win strategy that allows clothing companies to increase its sales and brand loyalty while consumers feel greater satisfaction.

The Determination of Dissolved Total Fe by Flow Injection Analysis in Environmental Samples

  • Kim, Do Hoon;Takeda, Kazuhiko;Sakugawa, Hiroshi;Lee, Jin Sik
    • Analytical Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.510-515
    • /
    • 2001
  • There has been an increasing need for analytical methods of dissolved total iron (tFe) that are highly sensitive, rapid, inexpensive and simple for environmental samples. A sensitive flow injection analysis (FIA) method for determining the concentration of tFe in environmental samples was developed. The proposed method required 10 minutes and only $500{\mu}L$ of sample for and analysis. The standard deviation was 5.0% at $0.5{\mu}gL^{-1}$ (n=6), and the detection limit was $0.075{\mu}gL^{-1}$. The developed method was applied to environmental samples such as tap water, mineral water, rain, snow and cloud water. Since this FIA system was free form interferences of coexisting ions commonly found in samples, sub-${\mu}gL^{-1}$ level of tFe could be easily determined without further preconcentration and separation.

  • PDF

Statistical Approach to Analyze Vibration Localization Phenomena in Periodic Structural Systems

  • Shin Sang Ha;Lee Se Jung;Yoo Hong Hee
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.7
    • /
    • pp.1405-1413
    • /
    • 2005
  • Malfunctions or critical fatigue problems often occur in mistuned periodic structural systems since their vibration responses may become much larger than those of perfectly tuned periodic systems. These are called vibration localization phenomena and it is of great importance to accurately predict the localization phenomena for safe and reliable designs of the periodic structural systems. In this study, a simple discrete system which represents periodic structural systems is employed to analyze the vibration localization phenomena. The statistical effects of mistuning, stiffness coupling, and damping on the vibration localization phenomena are investigated through Monte Carlo simulation. It is found that the probability of vibration localization was significantly influenced by the statistical properties except the standard deviation of coupling stiffness.

A Synthesis of Optically Active cis and trans 2-(5-Hydroxypoperidin-2-yl)acetates

  • P.N. Reddy;한상수;정교현
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.6
    • /
    • pp.617-618
    • /
    • 1998
  • A simple and reproducible pretreatment method was developed for the determination of dioxins in milk sample. Liquid-liquid extraction (LLE) was used for the initial extraction of the analyte from milk. For the elimination of interferences coextracted from milk, acid treatment followed by multilayer silica gel, and then alumina column clean-up were performed. The clean extract could be obtained without carbon column or high performance liquid chromatographic (HPLC) clean-up procedure. Polychlorinated biphenyles (PCBs) and dioxins were separated on neutral alumina activated at 180 ℃ for 12 hours. The final extract was analyzed by HPLC and high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The recovery of dioxins spiked in milk at 75-300 ppt level was 83.3-98.9% and their relative standard deviation was 4.1-14%.

Analytical Method for Dioxin and Organo-Chlorinated Compounds : (I) Pretreatment of Milk Samples for Dioxin Analysis

  • 양정수;김진영;최용욱;이대운
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.6
    • /
    • pp.619-624
    • /
    • 1998
  • A simple and reproducible pretreatment method was developed for the determination of dioxins in milk sample. Liquid-liquid extraction (LLE) was used for the initial extraction of the analyte from milk. For the elimination of interferences coextracted from milk, acid treatment followed by multilayer silica gel, and then alumina column clean-up were performed. The clean extract could be obtained without carbon column or high performance liquid chromatographic (HPLC) clean-up procedure. Polychlorinated biphenyles (PCBS) and dioxins were separated on neutral alumina activated at 180 ℃ for 12 hours. The final extract was analyzed by HPLC and high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The recovery of dioxins spiked in milk at 75-300 ppt level was 83.3-98.9% and their relative standard deviation was 4.1-14%.

Electrochemical Behavior and Differential Pulse Polarographic Determination of Piperacillin Sodium

  • Hahn, Young-hee;Son, Ean-ji
    • Archives of Pharmacal Research
    • /
    • v.23 no.3
    • /
    • pp.197-201
    • /
    • 2000
  • In an aqueous piperacillin sodium solution, a well-defined single wave or single peak was observed by direct current(DC) polarography or differential pulse polarography(DPP). The peak potential change per pH unit was -54 mV in the phosphate buffer at $18^{\circ}C$, which indicated that protons were involved in the electrochemical reduction of the 2,3-dioxopiperazine moiety of piperacillin sodium with a $H^{+}e^{-}$ ratio of one. Using a phosphate buffer of pH 4.3, the $1.0{times}10^{-7}$ M piperacillin sodium single peak could be determined by DPP with relative standard deviation of 1.6 %(n=3). Piperacillin sodium could be analyzed with-out interference from penicillin G-potassium, which enabled the employment of DPP as a fast and simple technique for monitoring the synthetic process of the antibiotic.

  • PDF

Criticality benchmark of McCARD Monte Carlo code for light-water-reactor fuel in transportation and storage packages

  • Jang, Junkyung;Lee, Hochul;Lee, Hyun Chul
    • Nuclear Engineering and Technology
    • /
    • v.50 no.7
    • /
    • pp.1024-1036
    • /
    • 2018
  • In this paper, McCARD code was verified using various models listed in the NUREG/CR-6361 benchmark guide, which provides specifications for single pin-cells, single assemblies, and the whole core classified depending on the nuclear properties and structural characteristics. McCARD code was verified by comparing its results with those of SCALE code for single pin-cell and single assembly benchmark problems. The difference in the multiplication factor obtained through the two codes did not exceed 90 pcm. The benchmark guide treats a total of 173 whole core experiments. The experiments are categorized as simple lattices, separator plates, reflecting walls, reflecting walls and separator plates, burnable absorber fuel rods, water holes, poison rods, and borated moderator. As a result of numerical simulation using McCARD, the mean value of the multiplication factors is 1.00223 and the standard deviation of the multiplication factors is 285 pcm. The difference between the multiplication factors and the experimental value is in the range of -665 pcm to + 1609 pcm. In addition, statistics of results for experiments categorized by reactor shape, additional structure, burnable poison, etc., are detailed in the main text.

Spectrophotometric Determination of Copper After Selective Extraction with $\alpha$-(2-Benzimidazolyl)-$\alpha ^{\prime}, \alpha ^{\prime} ^{\prime}$-(N-5-nitro-2-pyridyl hydrazone)-toluene in the Presence of Brij 58

  • 박찬일;김현수;차기원
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.3
    • /
    • pp.352-354
    • /
    • 1999
  • The spectrophotometric determination of Cu(Ⅱ) with α-(2-benzimidazolyl)-α',α"-(N-5-nitro-2-pyridylhydrazone)-toluene has been investigated. The optimum conditions of pH, stability, concentration of ligand and surfactant were evaluated. This method is a simple and sensitive method for determination of Cu(Ⅱ) and offers a selective separation of Cu(Ⅱ) from sample solution containin- I ppm below amount of Ni(Ⅱ), Co(Ⅱ), Zn(Ⅱ) and Sn(Ⅱ). Copper was determined by measuring the absorbance of Cu(Ⅱ)-BINPHT complex extracted with benzene in Brij 58 surfactant at 410 nm. Beer's law is obeyed over the concentration range 0∼2.5 μgmL-1 and the detection limit (S/N=2) is 0.06 μgmL-1. The relative standard deviation at the 0.3 μgmL-1 is 2.4% (N=7). The method was applied for the determination of Cu(Ⅱ) in various milks.

Availability and Utilizations of Library Information Resources in Secondary Schools by Special Patrons

  • Asuata, Isibhakhome Eleaena;Emasealu, Helen Uzoezi
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.12 no.1
    • /
    • pp.35-47
    • /
    • 2022
  • This study adopted the descriptive survey research method. The population of this study comprised of the hearing impaired students in selected government secondary schools in Rivers state. The population of hearing impaired students in Rivers State is 257. A simple random sampling technique was used to select a sample size of 159. A self-developed instrument titled "Availability and Utilization of Library Information Resources Questionnaire (AULIRQ)" was utilized for data collection. 153 responses were collated, indicating a 96.2% response rate. The data collected was arranged and analyzed using frequency count, percentages, and mean and standard deviation. Finding reveals that information resources in the libraries understudied were inadequate and under-utilized. Also, it was established that among other barriers, under-funding is a major barrier to making information resources available for the physically challenged. It was recommended that schools offering special education for the hearing impaired should pace up in their developmental gap by providing such resources and ensure adequate funding by all stakeholders.

Indirect Determination of Nitrite by Flame Atomic Absorption Spectrometry Using a Lead(IV) Dioxide Oxidant Microcolumn

  • Noroozifar, Meissam;Khorasani Motlagh, Mozhgan;Taheri, Aboozar;Homayoonfard, Marjan
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.6
    • /
    • pp.875-880
    • /
    • 2006
  • A new, simple and fast flow injection analysis (FIA) method has been developed for the indirect determination of nitrite. The proposed indirect automatic method is based on the oxidation of nitrite to nitrate using a lead(IV) dioxide oxidant microcolumn where the flow of the sample through the microcolumn reduces the $PbO_2$ solid phase reagent to Pb(II), which is measured by flame atomic absorption spectrometry. The absorbance of Pb(II) are proportional to the concentration of nitrite in the samples. The calibration curve was linear up to 30 mg $L ^{-1}$, with a detection limit of 0.11 mg $L ^{-1}$ for a 400 mL injected sample volume and a sampling rate of about 80 $h ^{-1}$. The results exhibit no interference from the presence of large amounts of ions. The developed procedure was found to be suitable for the determination of nitrite in foodstuffs and wastewaters. A relative standard deviation better than 0.9% was obtained in a repeatability study. The reliability of the method was established by parallel determination against the standard method.