• Title/Summary/Keyword: Simple myopic astigmatism

Search Result 24, Processing Time 0.017 seconds

Analysis of Astigmatism in Korean Adults from 20 to 29 Yesrs Old (20세부터 29세까지 한국인 성인 난시 분석)

  • Kim, Douk-Hoon;Park, Sang-Youl
    • Journal of Korean Clinical Health Science
    • /
    • v.9 no.1
    • /
    • pp.1478-1485
    • /
    • 2021
  • Purpose. To analysis of astigmatism in Korean adults from 20 to 29 years old. Methods. From January 2019 to February 2020, one hundred two subjects were performed in refraction test using the Auto-Refractometry. Results. In the type of astigmatism based on refractive error, the male's right eye was 4.26% simple myopic astigmatism and 95.74% complex myopic astigmatism, and the left eye was 2.22% simple myopic astigmatism and 97.78% complex myopic astigmatism. However, in the female's right eye, simple myopic astigmatism was 2.27%, complex myopic astigmatism was 97.73%, and left eye was simple myopic astigmatism was 2.17%, complex myopic astigmatism was 97.83%. The types of astigmatism in men and women similar to other. The mean refractive astigmatism values were -0.922±-0.798 diopter and -0.877±-0.707 diopter for male right and left eye, and -0.765±-0.599 diopter and -0.853±-0.586 diopter for female. On the other hand, the refraction values of the right and left eyes of men and women have statistical significance(p=0.000). The mean power comparative between refractive astigmatism and corneal astigmatism power were -0.186±-0.745 diopter, -1.091±-0.589 diopter in male and -1.140±-0.593 diopter, -1.140±-0.534 diopter in female. Therefore, the mean power values of the refractive astigmatism and corneal astigmatism of men and women were statistical significance(p=0.000). At the 0.75 diopter or more, which can have clinical symptoms of astigmatism power, males have 60.86% and 72.09% of the right and left eyes, and females have 47,64% and 60.10% of the right and left eyes. At 0.75 diopter or more, which can have clinical symptoms of corneal astigmatism power, males have 68.75% and 74% of the right and left eyes, and females have 86.50% and 82.35% of the right and left eyes. In the type of astigmatism axis, both men and women had a high frequency of the rule astigmatism. However, men had a high frequency of against-the-rule astigmatism and women showed a high frequency of oblique astigmatism. Conclusions. In this study, the complex myopic astigmatism and with-the rule astigmatism was the most common of all subjects. However, there was a statistical significance between right and left eyes of all subjects. The corneal astigmatism was higher refractive values in both males and females than refractive astigmatism. This study suggests that the analysis of the astigmatism can provide the useful diagnosis information for the correction of visual acuity.

Association between astigmatism and amblyopia.

  • Sapkota, Kishor;Kim, Douk Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.10 no.1
    • /
    • pp.1553-1558
    • /
    • 2022
  • Purpose: The aim of this study was to determine the association between stigmatism and amblyopia. Methods: It was a hospital based, cross-sectional retrospective study conducted in Nepal Eye Hospital. Medical record of amblyopic children aged 13 years or younger from were reviewed. Children with amblyopic eyes due to simple astigmatism were included. Relation between depth of amblyopia with magnitude and types of astigmatism, orientation of axis was determined. Out of 139 amblyopic eyes of 82 children, 93 were simple myopic astigmatism and remaining 42 were simple hyperopic astigmatism. Results: Mean age of patients was 7.38±2.61 years. Visual acuity improved by at least one line in Snellen chart in 4/5th of eyes after astigmatic correction. Moderate amblyopia was found to be present in 45% eyes while severe amblyopia in 16% of eyes. With the rule astigmatism was found to be present in 88% eyes. Mean astigmatism was 2.47±0.98D and majority of eyes (67.7%) had high astigmatism. Depth of amblyopia was not associated with magnitude of astigmatism (p > 0.05) but number of lines improved with astigmatic correction was correlated with the magnitude of astigmatism (p < 0.001). Risk of amblyopia is more in high myopic astigmatism. Conclusion: Presenting age of amblyopic children was late in Nepal. Depth of amblyopia was not associated with magnitude of astigmatism.

A Study of Eye Refraction state on old Age (노안의 굴절이상과 안경착용에 대한 연구)

  • Kim, Jin-Koo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.81-84
    • /
    • 2001
  • This study can provide the accurate information on the treatment of visual acuity of a old ages by test of eye refraction state. The test was performed the visual acuity test by the object methods, and subjects was the over 45 old age. The eye types were 12% positive for emmetropia, 19% for myopia. and 69% for hyperopia, respectively. The abnormal refraction eyes were 3% positive for simple myopic astigmatism, 16% for myopic astigmatism, 14% for simple hyperopia, 5% for simple hyperopic astigmatism, 62% for mixed astigmatism, respectively. The axis of astigmatisms were 72% positive for against-the-rule astigmatism, 21% for with-the-rule astigmatism, 7% for ablique astigmatism, respectively.

  • PDF

A Study of Abnormal Refraction Eye on Female Old Age (노인 여성의 굴절이상 눈에 대한 연구)

  • Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.125-129
    • /
    • 2000
  • To fine understand the visual acuity of female old age. This study was researched the visual acuity test by the object and subject methods. The major findings was as follows: 1. The eye types were 80.94% positive for hyperopia. 13.86% for myopia and 5.19% for emmetropia respectively. 2. The anbormal refraction eye was positive for mixed astigmatism for 78.27%, myoptic com pound astigmatism (10.99%), simple presbyopia(4.97%), myopic simple astigmatism(2.88%), presbyopia compound astigmatism (1.57%), simple myopia(0.78%) and presbyopia simple astigmatism(0.52%). 3. The axis of astigmatism was 60.23% for against regular astigmatism. 22.73% for oblique astigmatism and 17.05% for regular astigmatism respectively. 4. On the total myopic spheric power, the -0.50 spheric equivalent ${\leq}-2.00$ was 90.2%, the -2.00${\leq}-6.00$ was 9.8%. 5. On the total presbyopic spheric power, the -0.50${\leq}-2.00$ was 80.252%, the -2.00${\leq}-6.00$ was 16.99% and 2.56% for anything over the 6.00 diopter. 6. On the astigmatic power, the $0.50{\geq}$ cylinder power${\geq}1.00$ was 69.35%,the 1.00> cylinder power ${\geq}2.00$ was 27.38%, and anything over the 2.00 cylinder diopter was 3.27%.

  • PDF

Survey on the Refractive Status of Primary School Children with Subnormal Visual Acuity in Seoul (서울지역 초등학동 비정시안의 굴절상태에 대한 조사)

  • Kim, Hye Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.65-69
    • /
    • 2001
  • To investigate the visual acuity of the primary school children. This study was researched visual acuity test using objective and subjective methods. 1. The eye types were 90.3% positive for myopia, 3.1% for emmetropia, 4.9% hyperopia, 1.7% for mired astigmatism. 2. The abnormal refraction eyes were 58.6% positive for simple myopia, 29.9% for myopic compound astigmatism, 5.1% for my optic simple astigmatism and 1.9% for simple hyperopia, 1.9% for hyperopic compound astigmatism, 1.3% for hyperopic simple astigmatism, 1.3% for mixed astigmatism. 3. The axis of astigmatism were 85.7% for astigmatism with-the-rule, 9.3% for astigmatism against-the-rule, 5.0% for astigmatism oblique. 4. On total myopic spheric power. the -0.50

  • PDF

A study of Frequency Distributions by the Action styles (작업환경에서 오는 시력분포 및 고찰)

  • Kang, Hyang Nyeo;Kim, Sung Tae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.99-105
    • /
    • 2000
  • The classifying distribution by the action style was opticion 100, photoartist 100, college student 100 for the simple myopic 35%, for the simple myopic astigmatism 2%, for the compound myopic astigmatism 30.6% for the mixed astigmatism 62.6% for the compound hyperopic astigmatism 37.4% for the ratio of emmetropia 22.4% respectively. The retractive erroreye were -0.50~-2.00Dptr for the simple myopia 14%, -2.00~-6.00Dptr 16%, -6.00Dptr 5%, C-0.25(90.180)~C-2.00DptrAxis(90, 180) 2% for the simple myopicastigmatismS-0.25C-0.25DptrAxis(90, 180)~S-1.00C-1.00DptrAxis (90, 180) 22.6%, S-1.00C-1.00 DptrAxis (90, 180)~S-2.00C-2.00DptrAxis(90, 180) 8% for the compound myopic astigmatism. S+0.25C -0.25DptrAxis(90, 180)~S+2.00C-2.00DptrAxis(90,180) 6.2% for the mixed astigmatism. S+0.25C+0.25DptrAxis(90,180)~S+1.00C+1.00DptrAxis(90,180) 3.4%, S+1.00C+1.00DptrAxis(90,180)~S+2.00C+2.00DptrAxis(90,180) 0.34% for the compound hyperopic astigmatism.

  • PDF

The Study of the Abnormal Refraction Eye of the Primary School Children in Daegu (대구지역 초등학생 굴절이상안에 대한 연구)

  • Kim, Dae Nyoun;Kim, Hye Dong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.49-53
    • /
    • 2001
  • To investigate the visual acuity of the primary school children. the visual acuity test wan performed the object and subject method. The results were follows. 1. The eye types were 94.8% positive for myopia, 1.2% for emmetropia and 4.0% hyperopia, respectively. 2. The abnormal refraction eyes were 71.3% positive for simple myopia, 17.9% for myopic compound astigmatism, 6.9% for myopic simple astigmatism, and 2.5% for simple hyperopia, 0.6%for hyperopic compound astigmatism, 0.8%for hyperopic simple astigmatism, respectively. 3. The axis of astigmatism were 72.8% for astigmatism with-the-rule, 23.2% for astigmatism against-the-rule, 4.0% for astigmatism oblique, respectively. 4. On the total myopic spheric power, the -0.50

  • PDF

The Study of the Abnormal Refraction Eye on the Women Middle and High school Students (여자 중·고등학생들의 굴절이상 눈에 대한 연구)

  • Kim, Douk-Hoon;Shin, Jang-Cheol
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.135-140
    • /
    • 1999
  • To investigate the visual acuity of the women middle and high school students, the visual acuity test was performed the object and subject methods. The results were as follows; 1. The eye types were 96.7% positive for myopia, 2.5% for emmetropia, and 0.8% for hyperopia, respectively. 2. The abnormal refraction eyes were 61% positive for simple myopia, 35.2% for myopitic compound astigmatism, 3% for myopic simple astigmatism, and 0.8% for simple presbyopia, respectively. 3. The asix of astigmatism were 95% positive for irregular astigmatism axis, 3% for regular astigmatism axis, and 2% for oblique astigmatism axis, respectively. 4. On the total myopic spheric power, the -0.50

  • PDF

The Character Factor of Myopia by the Living Styles (생활 환경에서 오는 후천적 근시의 성격요인)

  • Kim, Jeong-Sik;Kang, Hywang-Yoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.129-133
    • /
    • 1999
  • For the myopia eyes of the people which are ametropia, the classified distribution has showed % for the simple myopic, 50% for the compound myopic astigmatism, 15% for the simple myopic astigmatism and 19% for the mixed astigmatism. The myopic ametropia for the both eyes has the distribution of 35% for -0.50D~-2.00Dptr, 54% for -2.00~6.00Dptr, and 11% for over -6.00Dptr. The classifying distribution for the age for the myopic ametropia was 54% for 15~20, 22% for 21~40, 14% for 41~60 and 10% for 61. The occupational distribution for the myopic ametropia has showed 61.5% for the student(Middle, High, College), 13.5% for the office worker, and 15% for the house wives as well as the small business. The hour affecting the refraction most for a day was after P.M. 7 which recorded 45% as the highest value. The reason is that the myopia degree decreases in the morning as the cornea flats and the situation is reversed in the afternoon so that there is a difference of Sph -0.50D and as getting darker the refraction degree of the light coming through the enlarged pupil refraction around the cornea is high. For the seasons the highest myopic degree has been recorded for 68% in the summer due to the shortage of nutrition and the climination inside the body by the exhaustion of sweat. In the blood types A and B are distributed closely as 34% and more active man with O has recorded higher myopic degree than woman. However woman showed higher accommodation power than man regardless the blood types. In the characteristic factors of myopic eye, the character feels fatigue easily has showed the distribution for 42% which is the highest and it could be classified largely by two the.

  • PDF

A Study of Eye Refraction State on Male Old Age (노인 남성의 안굴절 상태에 대한 연구)

  • Yoo, Jae Tae;Kim, Douk Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.21-25
    • /
    • 2000
  • The old age may experienced the visual acuity decrease according to refraction abnormality and they have a inconvenient real life style on viewing condition. So that, This study can provide the accurate information on the treatment of visual acuity of a male old ages by test of eye refraction state. The test was performed the visual acuity test by the object and subject methods.and the subjects was the Korean male over 55 old age. The eye types were 0.8 % positive for emmetropia, 15.2 % for myopia, and 84 % for hyperopia, respectively. The abnormal refraction eyes were 1.3 % positive for simple myopic astigmatism, 13.9 % for compound myopic astigmatism. 3.4 % for simple hyperopia and 3.1 % for simple hyperopic astigmatism, 77.5 % for mixed astigmatism, respectively. The asix of astigmatisms were 62% positive for against-the-rule astigmatism, 6% for with-the rule astigmatism, and 32 % for oblique astigmatism, respectively. On the total myopic spherical power, the $-0.50{\leq}$spheric equivalent <-2.00 diopter was 84.3%, the $-2.00{\leq}$spherical equivalent <-6.00.diopter was 15.7%. On the total hyperopic spherical power, the $+0.50{\leq}$spheric equivalent <+2.00 diopter was 74.2%, the $+2.00{\leq}$spherical equivalent <+6.00 diopter was 24.8%, and anything over the +6.00 diopter was 1%. On the astigmatic power, the $0.5{\leq}$cylinder <1.00 diopter was 54.1%, the $1.00{\leq}$cylinder <2.00 diopter was 32.4%, and anything over the 2.00 cylinder diopter was 13.5%.

  • PDF