• 제목/요약/키워드: Simple isolator

검색결과 30건 처리시간 0.022초

이중챔버를 이용한 공압가진기의 주파수 범위 확장 (Frequency Range Expansion of Pneumatic Exciter by Using Dual-chamber)

  • 박영우;김광준
    • 한국소음진동공학회논문집
    • /
    • 제23권10호
    • /
    • pp.909-919
    • /
    • 2013
  • Pneumatic exciters can be good replacements of electrodynamic, piezoelectric and hydraulic exciters owing to simple structure and large exciting force. One problem to be solved is a slow response caused by compressibility of air. Desirable frequency response characteristics of exciter are constant magnitude and zero degree phase, because users want no time delay between input signal and output force. For this reason, frequency range of pneumatic exciters is limited about 0~1 Hz. Therefore, expansion of frequency range is an important issue when designing the pneumatic exciter. In this paper, the pneumatic exciter which has same structure with active pneumatic isolator is dealt with. The dynamic characteristics are presented, and its limitation of expanding frequency range is shown based on analytical studies. Then the pneumatic exciter with dual-chamber is suggested to overcome this problem. Based on simulation study, a design method is presented.

Design approach of high damping rubber bearing for seismic isolation

  • Tiong, Patrick L.Y.;Kelly, James M.;Or, Tan T.
    • Smart Structures and Systems
    • /
    • 제20권3호
    • /
    • pp.303-309
    • /
    • 2017
  • Structural control through seismic isolation using elastomeric rubber bearing, which is also known as High Damping Rubber Bearing (HDRB), has seen an increase in use to provide protective from earthquake, especially for new buildings in earthquake zones. Besides, HDRB has also been used in structural rehabilitation of older yet significant buildings, such as museums and palaces. However, the present design approach applied in normal practice has often resulted in dissimilar HDRB dimension requirement between structural designers and bearing manufacturers mainly due to ineffective communication. Therefore, in order to ease the design process, most HDRB manufacturers have come up with catalogs that list all necessary and relevant product lines specifically for structural engineers to choose from. In fact, these catalogs contain physical dimension, compression property, shear characteristic, and most importantly, the total rubber thickness. Nonetheless, other complicated issues, such as the relationship between target isolation period and displacement demand (which determines the total rubber thickness), are omitted due to cul-de-sac fixing of these values in the catalogs. As such, this paper presents a formula, which is derived and extended from the present design approach, in order to offer a simple guideline for engineers to estimate the required HDRB size. This improved design formula successfully minimizes the discrepancies stumbled upon among structural designers, builders, and rubber bearing manufacturers in terms of variation order issue at the designing stage because manufacturer of isolator is always the last to be appointed in most projects.

LRB 기초분리장치의 교량 내진효과 (Seismic Effect of LRB Base Isolator on Bridges)

  • 황의승
    • 대한토목학회논문집
    • /
    • 제13권5호
    • /
    • pp.13-18
    • /
    • 1993
  • 본 논문의 목적은 LRB 기초분리장치가 설치된 교량의 내진효과를 해석하는 것이다. 기초분리방법은 지진력이 구조물에 전달되기 전에 그 영향을 최소화시키는 방법으로 현재 건물, 발전소, 교량 등의 구조물에 실용화되고 있다. 본 연구에서는 대표적인 기초분리장치인 Lead Rubber Bearing이 설치된 교량의 단순화된 모델을 개발하고 여러 크기의 LRB에 대하여 지진의 영향을 해석하였다. 단순화된 교량모델의 운동방정식을 Newmark ${\beta}$ 방법에 의해 시간이력해석을 수행하였다. 기초분리장치의 모델로는 이중선형성을 갖는 스프링을, 교각모델로는 비선형성 및 강성저하를 고려한 Q-HYST모델을 사용하였다. 해석예로 미국 네바다주에 소재한 Rose Creek 교량에 대한 남북방향 El Centro지진(1940)의 영향을 해석하였다. 상부구조 횡방향처짐, 교각연성 및 교각 밑면 전단력을 구하였다.

  • PDF

실험적 동적 모델을 이용한 헬기용 FLIR 센서의 마운트 설계 (Mount Design of Helicopter FLIR Sensor Using Experimental Dynamic Model)

  • 조기대
    • 한국소음진동공학회논문집
    • /
    • 제14권11호
    • /
    • pp.1129-1136
    • /
    • 2004
  • The structural modification to install a heavy sensor was made at the front extremities of the foreign-produced helicopter operated in the Korea Navy Mounting the sensor directly to the nose structure is unlikely to be practical because it lowers a dynamic mode of the airframe close to rotor blade passing frequencies, leading to increased helicopter vibration. Unfortunately we have no information on dynamic characteristics of the imported helicopter. So the experimental modal model derived from shake testing on the overall airframe of a working helicopter was used to solve the sensor Installation problems. The sensitivity analysis was done to evaluate what the best of modification woo)d be. Simple ID model and experimental modal data for mount system with sensor were Incorporated into overall dynamic model to assess the effects of the sensor installation on helicopter. Modal testing for the modified helicopter shows that the airframe modes are sufficiently displaced from rotor passing frequencies. The mount system has been proven fight to be sufficiently stable to meet vibration-level requirement for all required operational profiles.

철도레일 방진 체결장치의 진동 및 소음 저감 효과에 관한 실험적 연구 (Experimental Study of Vibration and Noise Reduction Effect of Railroad Vibration Isolator)

  • 이장현;김태언;이성춘;전익범
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1373-1378
    • /
    • 2000
  • Vibration caused by railroad vehicle including subway train running raises a lot of problems to the neighboring buildings. Therefore lots of methods to isolate the railway vibration have been studied and practically applied to sites. As one of them, specially designed vibration isolation device was installed in the some section of Seoul subway. This device is installed between the rail and track slab. Because the process of installation is relatively simple, this method can be applied to the existing railways in servicing. We measured the vibration and noise to check the effectiveness of this device before and after the installation. The result showed that the vibration level of the slab and platform was reduced to 7 - 10 dB. Expecially high frequency component was reduced to a large amount. From this result, we can conclude that these kind of devices are useful to the reduction of the railroad vibration, expecially the high frequency vibration which can cause structure born noise.

  • PDF

Efficient optimal design of passive structural control applied to isolator design

  • Kamalzare, Mahmoud;Johnson, Erik A.;Wojtkiewicz, Steven F.
    • Smart Structures and Systems
    • /
    • 제15권3호
    • /
    • pp.847-862
    • /
    • 2015
  • Typical base isolated buildings are designed so that the superstructure remains elastic in design-level earthquakes, though the isolation layer is often quite nonlinear using, e.g., hysteretic elements such as lead-rubber bearings and friction pendulum bearings. Similarly, other well-performing structural control systems keep the structure within the linear range except during the most extreme of excitations. Design optimization of these isolators or other structural control systems requires computationally-expensive response simulations of the (mostly or fully) linear structural system with the nonlinear structural control devices. Standard nonlinear structural analysis algorithms ignore the localized nature of these nonlinearities when computing responses. This paper proposes an approach for the computationally-efficient optimal design of passive isolators by extending a methodology previously developed by the authors for accelerating the response calculation of mostly linear systems with local features (linear or nonlinear, deterministic or random). The methodology is explained and applied to a numerical example of a base isolated building with a hysteretic isolation layer. The computational efficiency of the proposed approach is shown to be significant for this simple problem, and is expected to be even more dramatic for more complex systems.

Semi-active leverage-type isolation system considering minimum structural energy

  • Lin, Tzu-Kang;Lu, Lyan-Ywan;Chen, Chi-Jen
    • Smart Structures and Systems
    • /
    • 제21권3호
    • /
    • pp.373-387
    • /
    • 2018
  • Semi-active isolation systems based on leverage-type stiffness control strategies have been widely studied. The main concept behind this type of system is to adjust the stiffness in the isolator to match the fundamental period of the isolated system by using a simple leverage mechanism. Although this system achieves high performance under far-field earthquakes, it is unsuitable for near-fault strong ground motion. To overcome this problem, this study considers the potential energy effect in the control law of the semi-active isolation system. The minimal energy weighting (MEW) between the potential energy and kinetic energy was first optimized through a series of numerical simulations. Two MEW algorithms, namely generic and near-fault MEW control, were then developed to efficiently reduce the structural displacement responses. To demonstrate the performance of the proposed method, a two-degree-of-freedom structure was employed as a benchmark. Numerical results indicate that the dynamic response of the structure can be effectively dampened by the proposed MEW control under both far-field and near-fault earthquakes, whereas the structural responses resulting from conventional control methods may be greater than those for the purely passive control method. Moreover, according to experimental verifications, both the generic and near-fault MEW control modes yielded promising results under impulse-like earthquakes. The practicability of the proposed control algorithm was verified.

Experiment of an ABS-type control strategy for semi-active friction isolation systems

  • Lu, Lyan-Ywan;Lin, Ging-Long;Lin, Chen-Yu
    • Smart Structures and Systems
    • /
    • 제8권5호
    • /
    • pp.501-524
    • /
    • 2011
  • Recent studies have discovered that a conventional passive isolation system may suffer from an excessive isolator displacement when subjected to a near-fault earthquake that usually has a long-period velocity pulse waveform. Semi-active isolation using variable friction dampers (VFD), which requires a suitable control law, may provide a solution to this problem. To control the VFD in a semi-active isolation system more efficiently, this paper investigates experimentally the possible use of a control law whose control logic is similar to that of the anti-lock braking systems (ABS) widely used in the automobile industry. This ABS-type controller has the advantages of being simple and easily implemented, because it only requires the measurement of the isolation-layer velocity and does not require system modeling for gain design. Most importantly, it does not interfere with the isolation period, which usually decides the isolation efficiency. In order to verify its feasibility and effectiveness, the ABS-type controller was implemented on a variable-friction isolation system whose slip force is regulated by an embedded piezoelectric actuator, and a seismic simulation test was conducted for this isolation system. The experimental results demonstrate that, as compared to a passive isolation system with various levels of added damping, the semi-active isolation system using the ABS-type controller has the better overall performance when both the far-field and the near-fault earthquakes with different PGA levels are considered.

세 가지 프로브를 이용한 초고속 비행체 내부 항력 보정 기법의 실험적 연구 (An Experimental Study on Internal Drag Correction of High Speed Vehicle Using Three Probes)

  • 진현
    • 한국항공우주학회지
    • /
    • 제49권7호
    • /
    • pp.529-537
    • /
    • 2021
  • 스크램제트 엔진을 갖는 초고속 비행체로 풍동실험을 수행하였다. 스크램제트 엔진은 별도의 압축기가 없기 때문에 간단한 구조를 갖고 있지만 연소실에서 초음속 연소가 일어날 수 있도록 흡입구를 설계하는 것이 중요하다. 본 연구에서는 연소실 직전에 있는 격리부 출구면 압력 측정을 통해 내부 유동 특성 및 흡입구 시동 조건을 판단하였고 흡입구 성능 변수를 계산하여 마하수 별로 결과를 비교하였다. 유동관통형 초고속 비행체의 공력 특성도 분석하였고 정확한 공력 특성 분석을 위해서 내부 항력 보정이 필요하다. 본 연구에서는 내부 항력 보정을 위해 세 가지 프로브를 이용한 실험 기법을 제시하였다. 내부 항력 보정을 적용하여 내부 유동이 비행체 공력에 미치는 영향을 파악할 수 있었다.

산물벼 함수율 측정을 위한 $2{\times}2$ 마이크로스트립 패치 안테나 개발 (A $2{\times}2$ Microstrip Patch Antenna Array for Moisture Content Measurement of Paddy Rice)

  • 김기복;김종헌;노상하
    • Journal of Biosystems Engineering
    • /
    • 제25권2호
    • /
    • pp.97-106
    • /
    • 2000
  • To develop the grain moisture meter using microwave free space transmission technique, a 10.5GHz microwave signal with the power of 11mW generated by an oscillar with a dielectric resonator is transmitted to an isolator and radiated from a transmitting $2{\times}2$ microstrip patch array antenna into the sample holder filled with the 12 to 26%w.b. of Korean Hwawung paddy rice. the microwave signal, attenuated through the grain with moisture, is collected by a receiving $2{\times}2$ microstrip patch array antenna and detected using a Shottky diode with excellent high frequency characteristic. A pair of light and simple microstrip patch array antenna for measurement of grain moisture content is designed and implemented on atenflon substrate with trleative dielectric constant of 2.6 and thickness of 0.54 by using Ensemble ver. 4.02 software. The aperture of microstrip patch arrays is 41 mm width and 24mm high. The characteristics of microstrip patch antenna such as grain. return loss, and bandwidth are 11.35dBi, -38dB and 0.35GHz($50^{\circ}$ at far-field pattern of E and H plane. The width of the sample holder is large enough to cover the signal between the antennas temperature and bulk density respectively. The calibration model for measurement of grain moisture content is proposed to reduce the effects of fluectuations in bulk density and temperature which give serious errors for the measurements . From the results of regression analysis using the statistically analysis method, the moisture content of grain samples (MC(%)) is expressed in terms of the output voltage(v), temperature (t), and bulk density of samples(${\rho}b$)as follows ;$$MC(%)\;=\;(-3.9838{\times}10^{-8}{\times}v^{3}+8.023{\times}10^{-6}{\times}v^{2}-0.0011{\times}v-0.0004{\times}t+0.1706){\frac{1}{{\rho}b}}{\times}100$ Its determination coefficient, standard error of prediction(SEP) and bias were found to be 0.9855, 0.479%w.b. and -0.0.369 %w.b. respectively between measured and predicted moisture contents of the grain samples.

  • PDF