• Title/Summary/Keyword: Simple Technique

Search Result 3,399, Processing Time 0.03 seconds

Nipple Reduction with a Pentahedral Excision Technique (오면체 모양 절제법을 이용한 유두축소)

  • Hong, Yoon Gi;Sim, Hyung Bo
    • Archives of Plastic Surgery
    • /
    • v.36 no.3
    • /
    • pp.327-332
    • /
    • 2009
  • Purpose: Several methods of the nipple reduction have been reported. However, the methods described previously are difficult or have some demerits. This study proposes a simple technique for reduction of the nipple height as well as diameter. Methods: The purposed nipple height is marked. A pentahedral design of excision was marked around the nipple. Local anesthetic solution was infiltrated and a 4 - 0 Nylon traction suture was applied at the nipple apex. Excision of the nipple inside both two triangles and a rectangle was made. Remaining two flaps were approximated using 5 - 0 Nylon simple interrupted sutures. However, a part of wound closure was not done in the central area of the nipple. Results: 83 patients(166 nipples) underwent this procedure from December 1999 to December 2008. Follow up ranged from 6 months to 2 years with a mean of 10 months. 78 patients were female and 5 patients were male. No major complication occurred and remaining scars were very inconspicuous. Conclusion: This simple technique has the advantage of nipple reduction in both height and diameter, and provides good aesthetic outcomes.

Simple Estimation of Sound Source Directivity in Diffused Acoustic Field: Numerical Simulation (확산음향장에서의 음원 지향성 간이추정: 수치시뮬레이션)

  • Kim, Kookhyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.421-426
    • /
    • 2019
  • The directivity of an underwater sound source should be measured in an acoustically open field such as a calm sea or lake, or an anechoic water tank facility. However, technical difficulties arise when practically implementing this in open fields. Signal processing-based techniques such as a sound intensity method and near-field acoustic holography have been adopted to overcome the problem, but these are inefficient in terms of acquisition and maintenance costs. This study established a simple directivity estimation technique with data acquisition, filtering, and analysis tools. A numerical simulation based on an acoustic radiosity method showed that the technique is practicable for sound source directivity estimation in a diffused reverberant acoustic field like a reverberant water tank.

Spatial Downscaling Method for Use of GCM Data in A Mountainous Area (산악지역에 GCM 자료를 이용하기 위한 공간 축소방법 개발)

  • Kim, Soojun;Kang, Na Rae;Kim, Yon Soo;Lee, Jong So;Kim, Hung Soo
    • Journal of Wetlands Research
    • /
    • v.15 no.1
    • /
    • pp.115-125
    • /
    • 2013
  • This study established a methodology for the application of downscaling technique in a mountainous area having large spatial variations of rainfall and tried to estimate the change of rainfall characteristics in the future under climate change using the established method. The Namhan river basin, which is in the mountainous area of the Korean peninsula, has been chosen as the study area. Artificial Neural Network - Simple Kriging with varying local means (ANN-SKlm) has been built by combining artificial neural network, which is one of the general downscaling techniques, and SKlm technique, which can reflect the geomorphologic characteristics like elevation of the study area. The evaluation of SKlm technique was done by using the monthly rainfalls at six weather stations which KMA(Korea Meteorological Administration) is managing in the basin. The ANN-SKlm technique was compared with the Thiessen technique and ordinary kriging(OK) technique. According to the evaluation result of each technique the SKlm technique showed the best result.

Realization of High Q Inductor on Low Resistivity Silicon Wafer using a New and simple Trench Technique (새로운 트랜치 방법을 이용한 저저항 실리콘 기판에서의 High Q 인덕터의 구현)

  • 이홍수;이진효유현규김대용
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.629-632
    • /
    • 1998
  • This paper presents a new and simple technique to realize high Q inductor on low resistivity silicon wafer with 6 $\Omega$.cm. This technique is very compatible with bipolar and CMOS standard silicon process. By forming the deep and narrow trenches on the low resistivity wafer substrate under inductor pattern, oxidizing and filling with undoped polysilicon, the low resistivity silicon wafer acts as high resistivity wafer being suitable for the fabrication of high Q inductor. By using this technique the quality factor (Q) for 8-turn spiral inductor was improved up to max. 10.3 at 2 ㎓ with 3.0 $\mu\textrm{m}$ of metal thickness. The experiment results show that Q on low resistivity silicon wafer with the trench technique have been improved more than 2 times compared to the conventional low resistivity silicon wafer without trenches.

  • PDF

Double Random Phase Encryption Based Orthogonal Encoding Technique for Color Images

  • Lee, In-Ho;Cho, Myungjin
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.129-133
    • /
    • 2014
  • In this paper, we propose a simple Double random phase encryption (DRPE)-based orthogonal encoding technique for color image encryption. In the proposed orthogonal encoding technique, a color image is decomposed into red, green, and blue components before encryption, and the three components are independently encrypted with DRPE using the same key in order to decrease the complexity of encryption and decryption. Then, the encrypted data are encoded with a Hadamard matrix that has the orthogonal property. The purpose of the proposed orthogonal encoding technique is to improve the security of DRPE using the same key at the cost of a little complexity. The proposed orthogonal encoder consists of simple linear operations, so that it is easy to implement. We also provide the simulation results in order to show the effects of the proposed orthogonal encoding technique.

A Simple ESR Measurement Method for DC Bus Capacitor Using DC/DC Converter (DC/DC 컨버터를 이용한 DC Bus 커패시터의 간단한 ESR 측정 기법)

  • Shon, Jin-Geun;Kim, Jin-Sik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.372-376
    • /
    • 2010
  • Electrolytic capacitors have been widely used in power electronics system because of the features of large capacitance, small size, high-voltage, and low-cost. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. The estimation of the equivalent series resistance(ESR) is important parameter in life condition monitoring of electrolytic capacitor. This paper proposes a simple technique to measure the ESR of an electrolytic capacitor. This method uses a switching DC/DC boost converter to measure the DC Bus capacitor ESR of power converter. Main advantage of the proposed method is very simple in technique, consumes very little time and requires only simple instruments. Simulation results are shown to verify the performance of the proposed method.

Evaluation of the Educational Efficacy of a Cadaver-based Model for Teaching a Simple Suture Technique to Medical Students (임상실습과정 의과대학생을 대상으로 카데바 모델을 이용한 단순 봉합술 교육의 효율성)

  • Do, Hyun Soo;Min, Jin Hong;Hong, Seung Woo;Han, Sang Kyoon;Kim, In Soo;Ryu, Seung;Lee, Jin Woong;Kim, Seung Whan;Yoo, In Sool
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.121-125
    • /
    • 2006
  • Purpose: There is ongoing demand to deliver better procedural training to medical students in the emergency department. Thus, we studied the efficacy of a cadaver-based training model for teaching simple suture techniques to medical students. Methods: We investigated ten fourth-year medical students, who were rounding and being trained in the Emergency Department of Chungnam National University Hospital. They were educated with slides about a simple suture technique for 30 minutes to evaluate the efficacy of the cadaver-based training model. We prospectively measured their skill by administering a test on the cadaver-based simple suture technique in 3cm sized linar wound separately to each of them. Results: A total of ten fourth-year medical students completed the investigation. The tension, the direction of suture, the degree of cleanness, the number of sutures, the adequacy of the cutting thread length, and the suturing time in the first attempt were compared with those in the second one. The second results were compared with those in the third one, and the third results were compared with those in the fourth one. All the results had statistical significance. Conclusion: These findings support the value of the cadaver-based simple suture technique training model as a medical student teaching model. The cadaver-based simple suture technique teaching model is a good way of teaching several medical skills to medical students.

Electrochemical Detection of Lead and Cadmium in Human Saliva by Anodic Stripping Voltammetry (ASV) Analysis: A Pilot Study (양극 벗김 전압전류법 (Anodic stripping voltammetry: ASV)을 이용한 인체 타액 내 납과 카드뮴의 검출: 예비 연구)

  • Kim, Young-Jun;Kim, Cheul
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.347-355
    • /
    • 2007
  • The aim of this study was to evaluate the differences of salivary lead (Pb) and cadmium (Cd) concentrations, using ASV analysis, after various pre-treatment procedures. 10 unstimulated whole saliva samples of non-exposed subjects to Pb and Cd were collected. Each sample was divided into 6 aliquots and centrifugation was performed in only 3 aliquots. After centrifugation, 3 different types of pre-treatment procedures were carried out. Also, these pre-treatment procedures were carried out for another 3 aliquots, without centrifugation. Pre-treated aliquots were analyzed electrochemically, by ASV. The results are as follows: 1. Mean concentration of Pb in saliva after centrifugation was significantly higher than that of non-centrifugation. 2. In the detection sensitivity of Pb in saliva, those of simple dilution technique by HCl and acid digestion technique by nitric acid were significantly higher than that of simple dilution technique by electrolyte. 3. Mean concentration of Cd in saliva after centrifugation was significantly higher than that of non-centrifugation. 4. In the detection sensitivity of Cd in saliva, those of simple dilution technique by HCl and acid digestion technique by nitric acid were higher than that of simple dilution technique by electrolyte. But, there were no significant differences between them.

Equalizing pulse with error diffusion technique using Look-up-Table and subfield pattern for reducing dynamic false contour

  • Seo, Ki-Ho;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.321-324
    • /
    • 2003
  • We reported the method for the relatively simple equalizing pulse to reduce dynamic false contour. Equalizing pulse is determined by look-up-table and moving direction and velocity of the image. Used lookup-table is a few. If image moves to right or left, necessary LUT is only one for the velocity of 1 pixel/tvfield to right or left. This technique makes the process simple after obtaining motion information.

  • PDF

A Simple Three-Phase Single-Stage AC/DC Converter with Magnetic Energy Feedback Technique for Power Factor Correction (역률개선 위한 자기에어지 궤환기법의 간단한 삼상 단일전력단 AC/DC 컨버터)

  • 문건우;윤석호;윤종수;이기선;추진부
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.438-443
    • /
    • 1998
  • A simple single-stage AC/DC forward converter with transformer magnetic energy feedback technique for power factor correction is proposed. The operational principle of the proposed converter is presented. The proposed converter gives the good power factor correction, low line current harmonic distortions, and tight output voltage regulation. The prototype shows high power factor with low line current harmonics.

  • PDF