• Title/Summary/Keyword: Simmons model

Search Result 4, Processing Time 0.037 seconds

Analysis of Charge Transfer Mechanism in Molecular Memory Device using Temperature-dependent Electrical Measurement (온도에 의존하는 전기적 측정을 이용한 분자 메모리 소자의 전하 이동 메커니즘 분석)

  • Choi, Kyung-Min;Koo, Ja-Ryong;Kim, Young-Kwan;Kwon, Sang-Jik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.7
    • /
    • pp.615-619
    • /
    • 2008
  • A molecular memory device which has a structure of Al/$Al_2O_3$/ASA-15 LB monolayer/Ti/Al device, was fabricated. To study a charge transfer mechanism of molecular memory devices, current density-voltage (J-V) characteristics were measured at an increasing temperature range from 10 K to 300 K with an interval of 30 K. Strong temperature-dependent electrical property and tunneling through organic monolayer at low bias (below 0.5 V) were appeared. These experimental data were fitted by using a theoretical formula such as the Simmons model. In comparison between the theoretical and the experimental results, it was verified that the fitting results using the Simmons model about direct tunneling was fairly fitted below 0.5 V at both 300 K and 10 K. Hopping conduction was also dominant at all voltage range above 200 K due to charges trapped by defects located within the dielectric stack, including the $Al_2O_3$, organic monolayer and Ti interfaces.

Comparison of Tunneling Characteristics in the MTJs of CoFeB/MgO/CoFeB with Lower and Higher Tunneling Magnetoresistance

  • Choi, G.M.;Shin, K.H.;Seo, S.A.;Lim, W.C.;Lee, T.D.
    • Journal of Magnetics
    • /
    • v.14 no.1
    • /
    • pp.11-14
    • /
    • 2009
  • We investigated the I-V curves and differential tunneling conductance of two, CoFeB/MgO/CoFeB-based, magnetic tunnel junctions (MTJs): one with a low tunneling magnetoresistance (TMR; 22%) and the other with a high TMR (352%). This huge TMR difference was achieved by different MgO sputter conditions rather than by different annealing or deposition temperature. In addition to the TMR difference, the junction resistances were much higher in the low-TMR MTJ than in the high-TMR MTJ. The low-TMR MTJ showed a clear parabolic behavior in the dI/dV-V curve. This high resistance and parabolic behavior were well explained by the Simmons' simple barrier model. However, the tunneling properties of the high-TMR MTJ could not be explained by this model. The characteristic tunneling properties of the high-TMR MTJ were a relatively low junction resistance, a linear relation in the I-V curve, and conduction dips in the differential tunneling conductance. We explained these features by applying the coherent tunneling model.

Particle loading as a design parameter for composite radiation shielding

  • Baumann, N.;Diaz, K. Marquez;Simmons-Potter, K.;Potter, B.G. Jr.;Bucay, J.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3855-3863
    • /
    • 2022
  • An evaluation of the radiation shielding performance of high-Z-particle-loaded polylactic acid (PLA) composite materials was pursued. Specimens were produced via fused deposition modeling (FDM) using copper-PLA, steel-PLA, and BaSO4-PLA composite filaments containing 82.7, 75.2, and 44.6 wt% particulate phase contents, respectively, and were tested under broad-band flash x-ray conditions at the Sandia National Laboratories HERMES III facility. The experimental results for the mass attenuation coefficients of the composites were found to be in good agreement with GEANT4 simulations carried out using the same exposure conditions and an atomistic mixture as a model for the composite materials. Further simulation studies, focusing on the Cu-PLA composite system, were used to explore a shield design parameter space (in this case, defined by Cu-particle loading and shield areal density) to assess performance under both high-energy photon and electron fluxes over an incident energy range of 0.5-15 MeV. Based on these results, a method is proposed that can assist in the visualization and isolation of shield parameter coordinate sets that optimize performance under targeted radiation characteristics (type, energy). For electron flux shielding, an empirical relationship was found between areal density (AD), electron energy (E), composition and performance. In cases where ${\frac{E}{AD}}{\geq}2MeV{\bullet}cm{\bullet}g^{-1}$, a shield composed of >85 wt% Cu results in optimal performance. In contrast, a shield composed of <10 wt% Cu is anticipated to perform best against electron irradiation when ${\frac{E}{AD}}<2MeV{\bullet}cm{\bullet}g^{-1}$.

An Application Effect of Rhythmic Movement Program for the Health Promotion in the Elderly (노인의 건강증진을 위한 율동적 운동프로그램의 적용효과)

  • 이숙자
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.3
    • /
    • pp.776-790
    • /
    • 2000
  • Every year the number of the elderly increases in Korea thanks to the improvemen of social and economical levels and the development of medicine. However, many problems such as insufficent care and the isolation of the elderly have been commonplace. This trend exists not only because of increased lifespan but also the changing social structure of the nuclear family. Accordingly, inspite of the development of medicine, geriatric diseases including circulatory diseases are increasing in proportion of elderly population, as well as the severity. Therefore, it is important to emphasize that health care programs provide the best possible health care and functional capacities in terms of healthy elderly lifestyles. Especially, the phenomena of aging and geriatric diseases taking place with the elderly naturally are affected by lifestyle and the drastic changes in exercise patterns. This study aims to improve geriatric health by introducing a rhythmic movement program for the elderly to estabilish a health-promoting self-care system and by developing quality of life, perceived health status, their physical and physiological functions and emotional state. The theoretical framework used in this dissertation is derived from the Health-Promoting Self-Care System Model (Simmons, 1990), which integrates the Self-Care Deficit Nursing Theory (Orem, 1985), the interaction model of Client Health Behavior (Cox, 1982) and the Health Promotion Model (Pender, 1987). As a quasi-experimental design, the nonequivalent control group pretest-posttest design is utilized for this study. The subjects of this study consist of 64 people, over 65 years old who live in 2 nursing homes for the aged located in S city , Kyong-gi province and volunteered for this study from July, 12, 1999 to September, 17, 1999. They are divided into two groups:33 in the experimental group and 31 in the control group. The experimental group particpated in the Rhythmic Movement Program at the nursing home, which was comprised of 45 minutes a session, 5 sessions a week during 9 weeks. In order to measure the results of the Rhythmic Movement Program, aspects of perceived health status, balance, flexibility, grip strength, leg strength, heart rate, blood pressure, depression, anxiety and the quality of life were measured before and after participating in the Rhythimic Movement Program for the experimental group after 9 weeks, as well as the control group. The collected data were processed by SPSS PC+ and analyzed by the X2 test, t-test, ANCOVA and the Pearson Correlation Coefficient. The results of this study are as follows: 1. The perceived health status conditions in the experimental group show statistically significant improvement when compared to the control group (F=17.51, p=.000). 2. The physical and physiological functions, that is, balance (F=17.51, p=.000), flexibility (F=8.01, p=.006), grip strength (F=3.21, p=.018) and leg strength (F=25.78, p=.000) in the experimental group are higher than the control group. The vital signs, that is, the number of heart rate (F=.022, p=.884), systolic pressure (F=1.73 p=.193), and diastolic pressure (F=2.74, p=.103) in the experimental group compared to the control group decreased, but doesn't show statistically significant differences. Immune responses (F=5.13, p=.003) showed statistically significant increases in the experimental group when compared to the control group. 3. The emotional state are improved, that is, degree of depression (F=11.56, p=.001) and degree of anxiety (F=9.14, p=.004) in the experimental group showed statistically significant decreases. 4. The quality of life in the experimental group (F=3.03, p=.037) showed statistically significant differences compared to the control group. 5. The observations of the relationships among the perceived health status, emotional state , the quality of life, the relationships between the perceived health status, the degree of depression (r=-.653, p=.000) and the degree of anxiety (r=-.786, p=.000) were in contrary propotions, while the relationships between the perceived health status and the quality of life (r=.234, p=.008) were in direct propotion. In conclusion, the Rhythmic Movement Program used in this study for geriatric nursing care is simple and safe for application to the elderly and shows significant effects by implementing 5 sessions a week for 9 weeks. The Rhythmic Movement Program improves the quality of life, maintains as well as improves the physical and physiological fuctions and emotional state, therefore this program is strongly recommended for positive applications for independant geriatric nursing health care.

  • PDF