• Title/Summary/Keyword: Silver oxide

Search Result 173, Processing Time 0.026 seconds

Influence of Source/Drain Electrodes on the Properties of Zinc Tin Oxide Transparent Thin Film Transistors (Zinc Tin Oxide 투명 박막트랜지스터의 특성에 미치는 소스/드레인 전극의 영향)

  • Ma, Tae Young;Cho, Mu Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.7
    • /
    • pp.433-438
    • /
    • 2015
  • Zinc tin oxide transparent thin film transistors (ZTO TTFTs) were fabricated by using $n^+$ Si wafers as gate electrodes. Indium (In), aluminum (Al), indium tin oxide (ITO), silver (Ag), and gold (Au) were employed for source and drain electrodes, and the mobility and the threshold voltage of ZTO TTFTs were observed as a function of electrode. The ZTO TTFTs adopting In as electrodes showed the highest mobility and the lowest threshold voltage. It was shown that Ag and Au are not suitable for the electrodes of ZTO TTFTs. As the results of this study, it is considered that the interface properties of electrode/ZTO are more influential in the properties of ZTO TTFTs than the conductivity of electrode.

In Vitro Cytotoxicity of Zinc Oxide Nanoparticles in Cultured Statens Seruminstitut Rabbit Cornea Cells

  • Lee, Handule;Park, Kwangsik
    • Toxicological Research
    • /
    • v.35 no.3
    • /
    • pp.287-294
    • /
    • 2019
  • The possibility of eye exposure for workers participating in manufacturing of nanoparticles or consumers using products containing nanoparticles has been reported, but toxicity studies on the eye are scarce. In this study, cytotoxicity of five nanoparticles including silver, ceria, silica, titanium and zinc were tested using Statens Seruminstitut Rabbit Cornea (SIRC) cells. When cells were treated with nanoparticles with concentrations of $1-100{\mu}g/mL$ for 24 hr, zinc oxide nanoparticles showed higher toxicity to cornea cells. $LC_{50}$ of zinc oxide nanoparticles was less than $25{\mu}g/mL$ but those of other nanoparticles could not be calculated in this test, which means more than $100{\mu}g/mL$. Generation of reactive oxygen species was observed, and expression of apoptosis related biomarkers including Bax and Bcl-2 were changed after treatment of zinc oxide nanoparticles, while no other significant toxicity-related changes were observed in cornea cells treated with Ag, $CeO_2$, $SiO_2$ and $TiO_2$ nanoparticles.

The Influence of Temperature on the Recovery Reaction of Silver Based on the Pourbaix Diagram (Pourbaix Diagram에 의거한 은(銀)의 회수반응(回收反應)에 미치는 온도영향(溫度影響))

  • Won, Yu-Ra;Kim, Dong-Su
    • Resources Recycling
    • /
    • v.21 no.6
    • /
    • pp.74-81
    • /
    • 2012
  • The Influence of temperature on the recovery reaction of silver in aqueous solution was investigated based on Pourbaix diagram constructed by thermodynamic calculation at different temperatures. It was observed that the stability of water is more strongly affected by pH variation and the stable region of ${Ag^+}_{(aq)}$ is diminished at higher temperature. It was shown that the recovery of $Ag_{(aq)}$ in the forms of $Ag_{(s)}$ and $Ag_2O_{3(s)}$ is more advantageous thermodynamically at lower temperature, however, the recovery of $Ag_{(aq)}$ in the forms of $Ag_2O_{(s)}$$Ag_2O_{2(s)}$ is more advantageous as temperature increases. The rise of temperature is considered to demote the recovery of silver thermodynamically in strong acidic condition ($pH{\leq}2$), but more silver is regarded to be recovered with temperature above pH 2. Finally, The recovery of silver in the elemental state is shown to be more sensitively influenced by temperature variation compared with the recovery of silver in its oxide form.

Silver Nanowire-Based Stretchable Transparent Electrodes for Deformable Organic Light-Emitting Diodes (신축성 유기발광다이오드를 위한 은 나노와이어 기반의 신축성 투명 전극 기판 연구)

  • Jung, Hyunsu;Go, Hyeck;Park, Gye-Choon;Yun, Changhun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.609-614
    • /
    • 2017
  • The proposed stretchable transparent electrodes based on silver nanowires (AgNWs) were prepared on a polyurethane (PU) substrate. In order toavoid the surface roughness caused by the silver nanowires, a titanium oxide ($TiO_2$) buffer layer was addedby coating and heating the organometallic sol-gel solution. The fabricated stretchable electrodes showedan electrical sheet resistance of $24{\Omega}sq^{-1}$, 78% transmittance at 550 nm, and an average surface roughness below 5 nm. Furthermore, the AgNW-based electrode maintained its initial electrical resistance under 130% strain testing conditions, without the assistance of additional conductive polymer layers. In this paper, the critical role of the $TiO_2$ buffer layer between the AgNW network and the PU substrate has been discussed.

A Studies on the Characteristics of Reliability Test by Automotive Touch Screen Silver Pastes (자동차 터치스크린용 실버페이스트 종류에 따른 신뢰성 테스트 특성 연구)

  • Kim, Jung-won;Choi, Ung-se
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.205-208
    • /
    • 2016
  • In this paper, different types of touch screen silver pastes for bonding in conductive pattern formed over the ito film by bonding each sample of 5 was dried. The dry conditions, the oxidation of the ito film is a condition that does not occur. Reliability testing constant temp and humidity, cold-hot impact test is in progress. Each test will check the status of five sheets conductive pattern bonding. Conductive pattern bonding, after each 240,480,615 hours to check the status of silver pattern bonding. Reliability testing these through different silver pastes can see that the change in the adhesion and conductivity deterioration of the quality can be prevented, and reliability testing low temperature curing from the surface of silver pastes that can come as soon as the discoloration was unknown.

Disinfection Efficiency of Silver Disinfectants for Biofilm (은 화합물을 이용한 생물막 제어)

  • Kim, Jae-Eun;Kim, Jee-Yeon;Yoon, Je-Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.81-87
    • /
    • 2006
  • The industrial systems contain many sites and components susceptible to biofilms formation. Biofilms play an important role in microbial growth and industrial fouling. Thus, the control of the biofilms in industrial systems has been emphasized, however, the efficient controlling method was not provided yet. Since silver compounds have no residual and corrosion problem, the interest for silver compounds as a biofilm control disinfectant has been increased. In this study, we attempted to examine the disinfection ability of silver compounds. The disinfection efficiency of two silver compounds(silver ion and silver oxide) were evaluated for biofilms in comparison with suspended cells using well known indicator microorganisms(E. coli, P. aeruginosa) and compared with that of chlorine. Silver compounds were found to be effective in inactivating E. coli and P. aeruginosa biofilms. The reason for superiority of silver compounds as biofilm disinfectant was suggested by that silver can penetrate into the inner biofilm matrix faster than chlorine without consumption. This study reports that the disinfectant which is highly effective in inactivating the suspended cells in water becomes the less effective for controlling biofilm because of its high reactivity. This results imply that the effective strategy for biofilm control can be achieved by considering thoroughly the chemical nature of disinfects and biofilm structure and the reactivity between them.

Metal Oxide Thin Film Transistor with Porous Silver Nanowire Top Gate Electrode for Label-Free Bio-Relevant Molecules Detection

  • Yu, Tae-Hui;Kim, Jeong-Hyeok;Sang, Byeong-In;Choe, Won-Guk;Hwang, Do-Gyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.268-268
    • /
    • 2016
  • Chemical sensors have attracted much attention due to their various applications such as agriculture product, cosmetic and pharmaceutical components and clinical control. A conventional chemical and biological sensor is consists of fluorescent dye, optical light sources, and photodetector to quantify the extent of concentration. Such complicated system leads to rising cost and slow response time. Until now, the most contemporary thin film transistors (TFTs) are used in the field of flat panel display technology for switching device. Some papers have reported that an interesting alternative to flat panel display technology is chemical sensor technology. Recent advances in chemical detection study for using TFTs, benefits from overwhelming progress made in organic thin film transistors (OTFTs) electronic, have been studied alternative to current optical detection system. However numerous problems still remain especially the long-term stability and lack of reliability. On the other hand, the utilization of metal oxide transistor technology in chemical sensors is substantially promising owing to many advantages such as outstanding electrical performance, flexible device, and transparency. The top-gate structure transistor indicated long-term atmosphere stability and reliability because insulator layer is deposited on the top of semiconductor layer, as an effective mechanical and chemical protection. We report on the fabrication of InGaZnO TFTs with silver nanowire as the top gate electrode for the aim of chemical materials detection by monitoring change of electrical properties. We demonstrated that the improved sensitivity characteristics are related to the employment of a unique combination of nano materials. The silver nanowire top-gate InGaZnO TFTs used in this study features the following advantages: i) high sensitivity, ii) long-term stability in atmosphere and buffer solution iii) no necessary additional electrode and iv) simple fabrication process by spray.

  • PDF