• 제목/요약/키워드: Silorane system adhesive

검색결과 5건 처리시간 0.021초

Microtensile bond strength of silorane-based composite specific adhesive system using different bonding strategies

  • Bastos, Laura Alves;Sousa, Ana Beatriz Silva;Drubi-Filho, Brahim;Pires-de-Souza, Fernanda de Carvalho Panzeri;Garcia, Lucas da Fonseca Roberti
    • Restorative Dentistry and Endodontics
    • /
    • 제40권1호
    • /
    • pp.23-29
    • /
    • 2015
  • Objectives: The aim of this study was to evaluate the effect of pre-etching on the bond strength of silorane-based composite specific adhesive system to dentin. Materials and Methods: Thirty human molars were randomly divided into 5 groups according to the different bonding strategies. For teeth restored with silorane-based composite (Filtek Silorane, 3M ESPE), the specific self-etching adhesive system (Adhesive System P90, 3M ESPE) was used with and without pre-etching (Pre-etching/Silorane and Silorane groups). Teeth restored with methacrylate based-composite (Filtek Z250, 3M ESPE) were hybridized with the two-step self-etching system (Clearfil SE Bond, Kuraray), with and without pre-etching (Pre-etching/Methacrylate and Methacrylate groups), or three-step adhesive system (Adper Scotchbond Multi-Purpose, 3M ESPE) (Three-step/Methacrylate group) (n = 6). The restored teeth were sectioned into stick-shaped test specimens ($1.0{\times}1.0mm$), and coupled to a universal test machine (0.5 mm/min) to perform microtensile testing. Results: Pre-etching/Methacrylate group presented the highest bond strength values, with significant difference from Silorane and Three-step/Methacrylate groups (p < 0.05). However, it was not significantly different from Pre-etching/Silorane and Methacrylate groups. Conclusions: Pre-etching increased bond strength of silorane-based composite specific adhesive system to dentin.

접착시스템의 소수성이 Low-shrinkage silorane resin과 상아질의 미세인장강도에 미치는 영향 (Effect of adhesive hydrophobicity on microtensile bond strength of low-shrinkage silorane resin to dentin)

  • 조소연;강현영;김경아;유미경;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제36권4호
    • /
    • pp.280-289
    • /
    • 2011
  • 연구목적: 본 연구의 목적은 다양한 소수성을 지닌 최신 상아질 접착시스템과 저수축 silorane 레진의 미세인장결합강도를 평가하는 것이다. 연구 재료 및 방법: 36개의 갓 발치된 제3대구치를 이용했다. Low-speed diamond saw를 사용하여 교합면에 평행하게 치관을 잘라 middle dentin을 노출시켰다. 치아를 무작위로 9 group으로 나눴다. Silorane self-etch adhesives (SS), SS + phosphoric acid etching (SS + pa), Adper Easy bond (AE), AE + Silorane system bonding (AE + SSb), Clearfil SE bond (CSE), CSE + SSb, All-Bond 2 (AB2), AB2 + SSb, All-Bond 3 (AB3). 접착제를 적용한 후에 Filtek LS (3M ESPE)를 2 mm씩 3회 적층충전하였다. 각 층은 40s씩 광중합하였다. 0.8 mm ${\times}$ 0.8 mm stick을 Micro Tensile Tester로 1 mm/min cross-head speed의 인장력을 가하였다. 파절양상를 관찰하기 위해 광학현미경을 이용하였다. 5가지 접착제의 소수성정도를 결정하기위해 water sorption test하였다. 결과: silorane 레진과 5가지 접착제의 ${\mu}TBS$: SS, 23.2 ${\pm}$ 6.9 MPa; CSE, 19.4 ${\pm}$ 4.4 MPa; AB3, 30.3 ${\pm}$ 4.0 MPa; AB2와 AE, no bond. Additional layering of SSb: CSE + SSb, 26.2 ${\pm}$ 10.3 MPa; AB2 + SSb, 33.9 ${\pm}$ 7.3 MPa; AE + SSb, no bond. 높은 ${\mu}TBS$는 cohesive failure와 관련있었다. SS는 낮은 가장 낮은 water sorption을 보였고 다음으로 AB3, AE, CSE, AB2 순서였다. AE는 가장 높은 용해도를 나타냈고 다음으로 CSE, AB2였다. 결론: 접착제의 소수성이 증가할수록, silorane 레진의 접착강도도 증가하였다. 비전용접착제 위에 silorane adhesive bonding을 layering하는 것은 AB2 + SSb 그룹에서만 결합강도를 유의하게 증가시켰다. AB3는 SS와 유사한 ${\mu}TBS$ & water sorption을 나타냈다. 따라서 AB3는 siloran resin을 접착시키는데 SS를 대체할만한 경쟁력있는 접착제이다.

Low-shrinking composites. Are they reliable for bonding orthodontic retainers?

  • Uysal, Tancan;Sakin, Caglar;AI-Qunaian, Talal
    • 대한치과교정학회지
    • /
    • 제41권1호
    • /
    • pp.51-58
    • /
    • 2011
  • Objective: To evaluate the shear bond strength (SBS), fracture mode, wire pull out (WPO) resistance and microleakage between low-shrinking and conventional composites used as a lingual retainer adhesive. Methods: A total of 120 human mandibular incisor teeth, extracted for periodontal reasons, were collected. Sixty of them were separated into two groups. To determine the SBS, either Transbond-LR (3M-Unitek) or Silorane (3M-Espe) was applied to the lingual surface of the teeth by packing the material into standard cylindrical plastic matrices (Ultradent) to simulate the lingual retainer bonding area. To test WPO resistance, 20 samples were prepared for each composite where the wire was embedded in the composite materialand cured. Then tensile stress was applied until failure of the composite occurred. The remaining 60 teeth were divided into two groups and multi-stranded 0.0215-inch diameter wire was bonded with the same composites. Microleakage was evaluated by the dye penetration method. Statistical analyses were performed by Wilcoxon, Pearson chi-square, and Mann-Whitney-U tests at p < 0.05 level. Results: The SBS and WPO results were not statistically significant between the two groups. Significant differences were found between the groups in terms of fracture mode (p < 0.001). Greater percentages of the fractures showed mix type failure (85%) for Silorane and adhesive (60%) for Transbond-LR. Microleakage values were lower in low-shrinking composite than the control and this difference was found to be statistically significant (p < 0.001). Conclusions: Low-shrinking composite produced sufficient SBS, WPO and microleakage values on the etched enamel surfaces, when used as a lingual retainer composite.

Silorane계 복합레진의 중합수축응력의 평가 (Evaluation of polymerization shrinkage stress in silorane-based composites)

  • 류승지;전지훈;민정범
    • Restorative Dentistry and Endodontics
    • /
    • 제36권3호
    • /
    • pp.188-195
    • /
    • 2011
  • 연구목적: 새로운 silorane 복합레진의 중합수축응력을 기존의 methacrylate 계열의 복합레진과 비교 분석하는 것이다. 연구 재료 및 방법: Z250, P60, P90 각 군당 10개의 시편을 준비하였다. 시편에 스트레인 게이지를 부착하고 각 재료의 제조사에서 추천하는 접착제 도포 후 10초간, 수복 재료 적용 후 40초간 할로겐 광조사기로 광중합한 뒤 중합수축응력을 측정 하였다. 외경 10 mm, 내경 7 mm, 높이 3 mm의 아크릴릭 주형을 준비하고 주형의 내면은 5초간 sandblasting 처리한 후, 30초간 35% 인산으로 산부식 시행하였다. 주형의 외면은 Cyanoacrylate adhesive (SOKKI)로 스트레인 게이지를 부착하였다. 주형의 내면과 복합 레진을 접착하기 위한 접착제로 methacrylate 기질의 복합 레진 2종은 Single Bond (3M ESPE)를, silorane 기질의 복합레진은 P90 Adhesive system (3M ESPE)을 적용하였고 할로겐 광조사기를 사용하여 10초간 광중합하였다. 시편에 부착된 스트레인 게이지를 TML data logger에 연결시키고 광중합 전의 초기값을 설정한다. 중합시간은 모든 군의 에너지 총량을 동일하게 하기 위해 400 mW/$cm^2$의 광강도로 설정하여 40초간 광중합하였다. 광중합 시점부터 1초 간격으로 800초 간의 스트레인 값을 측정하였고 스트레인 값은 Hooke's law를 이용하여 각 시점의 수축응력으로 환산하여 기록하였다. 결과: 1. 모든 군에서 광중합 직후에는 일시적으로 팽창하였다가 급속한 수축률을 보였고 시간이 지날수록 수축률이 감소하는 경향을 보이다가 200초 이후에는 수축률이 완만해지는 양상을 보였다. 2. 모든 군에서 수축응력이 계속 증가하였고, silorane 기질의 복합레진 P90이 methacrylate 기질의 복합레진 Z250, P60 보다 낮은 수축응력 값을 보였다(p < 0.05). 3. Methacrylate 기질의 복합레진인 Z250과 P60 두가지 재료간 수축응력에는 통계적으로 유의한 차이가 없었다(p > 0.05). 결론: Silorane 기질 복합레진의 사용은 methacrylate 기질 복합레진보다 중합수축응력이 더 작을 것으로 기대되지만 silorane 기질 복합레진의 탄성계수에 있어서 다소 불리한 특성이 보고되는 바, 임상적 적용에 앞서 이에 대한 충분한 고찰 및 추가적인 연구가 더 필요할 것으로 사료된다.

Effect of 38% carbamide peroxide on the microleakage of silorane-based versus methacrylate-based composite restorations

  • Hashemi Kamangar, Sedighe Sadat;Ghavam, Maryam;Mahinfar, Nazanin;Pourhashemi, Seyed Jalal
    • Restorative Dentistry and Endodontics
    • /
    • 제39권3호
    • /
    • pp.172-179
    • /
    • 2014
  • Objectives: This study aimed to assess the effect of 38% carbamide peroxide on the microleakage of class V cavities restored with either a silorane-based composite or two methacrylate-based composites. Materials and Methods: A total of 96 class V cavities were prepared on the buccal surface of extracted human teeth with both enamel and dentin margins and were randomly assigned into three groups of Filtek P90 (3M-ESPE) + P90 system adhesive (3M-ESPE)(group A), Filtek Z250 (3M-ESPE) + Adper Prompt L-Pop (3M-ESPE)(group B) and Filtek Z350XT (3M-ESPE) + Adper Prompt L-Pop (group C). Half of the teeth were randomly underwent bleaching (38% carbamide peroxide, Day White, Discus Dental, applying for 15 min, twice a day for 14 day) while the remaining half (control) were not bleached. Dye penetration was measured following immersion in basic fuchsine. Data were statistically analyzed using Kruskal-Wallis and Mann-Whitney U tests at a level of 0.05. Results: No significant differences were found between composites in the control groups in enamel (p = 0.171) or dentin (p = 0.094) margins. After bleaching, microleakage of Z250 (in enamel [p = 0.867] or dentin [p = 0.590] margins) and Z350 (in enamel [p = 0.445] or dentin [p = 0.591]margins) did not change significantly, but the microleakage of P90 significantly increased in both enamel (p = 0.042) and dentin (p = 0.002) margins. Conclusions: No significant differences were noted between the bleached and control subgroups of two methacrylate-based composites in enamel or dentin margins. Microleakage of silorane-based composite significantly increased after bleaching.