Performance Evaluation of Octonion Space-Time Coded Physical Layer Security in MIMO Systems (MIMO 시스템에서 옥토니언 시공간 부호를 이용한 물리계층 보안에 대한 성능 분석)

  • Young Ju Kim;BeomGeun Kwak;Seulmin Lim;Cheon Deok Jin
    • Journal of Broadcast Engineering
    • /
    • v.28 no.1
    • /
    • pp.145-148
    • /
    • 2023
  • Open-loop Octonion space-time block code for 4 transmit antenna system is considered and random phases are applied to 4 transmit antennas for physical layer security. When an illegal hacker estimates the random phases of 1 through 4 transmit antennas with maximum likelihood (ML), this letter analyzes the bit error rate (BER) performances versus signal-to-noise ratio (SNR). And the Octonion code in the literature[1] does not have full orthogonality so, this letter employs the perfect orthogonal Octonion code. When the hacker knows that the random phases are 2-PSK constellations and he should estimate all the 4 random phases, the hacking is impossible until 100dB. When the hacker possibly know that some of the random phases, bit error rate goes down to 10-3 so, the transmit message could be hacked.

Shear-wave elasticity imaging with axial sub-Nyquist sampling (축방향 서브 나이퀴스트 샘플링 기반의 횡탄성 영상 기법)

  • Woojin Oh;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.403-411
    • /
    • 2023
  • Functional ultrasound imaging, such as elasticity imaging and micro-blood flow Doppler imaging, enhances diagnostic capability by providing useful mechanical and functional information about tissues. However, the implementation of functional ultrasound imaging poses limitations such as the storage of vast amounts of data in Radio Frequency (RF) data acquisition and processing. In this paper, we propose a sub-Nyquist approach that reduces the amount of acquired axial samples for efficient shear-wave elasticity imaging. The proposed method acquires data at a sampling rate one-third lower than the conventional Nyquist sampling rate and tracks shear-wave signals through RF signals reconstructed using band-pass filtering-based interpolation. In this approach, the RF signal is assumed to have a fractional bandwidth of 67 %. To validate the approach, we reconstruct the shear-wave velocity images using shear-wave tracking data obtained by conventional and proposed approaches, and compare the group velocity, contrast-to-noise ratio, and structural similarity index measurement. We qualitatively and quantitatively demonstrate the potential of sub-Nyquist sampling-based shear-wave elasticity imaging, indicating that our approach could be practically useful in three-dimensional shear-wave elasticity imaging, where a massive amount of ultrasound data is required.

Levels of sulfonamides for animals in food (식품 중 설폰아마이드계 동물용의약품의 잔류실태)

  • Jeong, Jiyoon;Hong, Mooki;Choi, Dongmi
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.84-90
    • /
    • 2007
  • To determine levels of 11 sulfonamides for animals in food, simultaneously, a selective method of high performance liquid chromatography with UV detector has been applied. The targets were sulfachlorpyridazine (SCP), sulfadiazine (SDZ), sulfadimethoxine (SDM), sulfisoxazole (SSX), sulfamerazine (SMZ), sulfamethazine (SMT), sulfamethoxazole (SMX), sulfamethoxypyridazine (SMP), sulfamonomethoxine (SMM), sulfaquinoxaline (SQX) and sulfathiazole (STZ). Food samples were beef, pork, chicken, milk and whole egg that were collected at the main 6 cities in Korea as Seoul, Busan, Daejon, Incheon, Mokpo and Gangneung. After homogenizing food samples with sodium phosphate solution and acetonitrile, it was extracted with n-hexane. The mobile phase gradient was a mixture of 5 mM potassium phosphate (pH 3.25) and methanol with a gradient ratio from 100:0 to 30:70. The UV wavelength was 270 nm. The overall recoveries were ranged from 75% to 95% and the limit of detection was minimum 0.004 mg/kg for SMT, and 0.007 mg/kg for STZ at signal/noise > 3, respectively. As results, sulfonamide drugs were not detected in most of the selected food samples, however, sulfamonomethoxine was detected in meat. The determined level of sulfamonomethoxine were 0.03 and 0.06 mg/kg for beef that were below the MRLs.

A Study on X-ray Radiography for the Diagnosis of Screw Insertion Operation of Odontoid Fracture Patients in Cervical (목뼈 치아돌기 골절 환자의 나사못 삽입수술 진단을 위한 X-Ray 촬영법 연구)

  • Byung-Ju-Ahn;In-Soo Kim;Jong-Nam Song;Jae-Bok Han
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.309-315
    • /
    • 2024
  • The Study In order to obtain a Clear Image of fractures in Atlas and Axis of Cervical Spin, this Study obtained Images examined using a Cervical Spin Pantom and a Radiation device, and then Commissioned five Radiologists and three Orthopedic Regent Doctors for Subjective Psychological ROC (Receiver, Operation, Characteristic) Evaluation. As aRresult, the X-ray Tube was Tilted 15° toward the leg to Receive a high score of 29 Points during the Eamination, and the Objective Evaluation Signal-to-noise Ratio (SNR) was 6.032 points, which was high. In Addition, by Tilting the X-ray tube 10° toward the head, it received a high score of 33 points during the Examination, and a high score of 7.840 Points in the objective evaluation. And as a result of Subjectively and Objectively Statistically Evaluating the Examined Images, the Cronbach Alpha value was Calculated as 0.791. Since the Cronbach Alpha value was 0.7 or higher, the Reliability could be Evaluated as 'very good', and the significance probability (p) was Statistically Significant at 0.042 points.

The study of PbO's sintering effect for high efficiency x-ray detection sensor (고효율 방사선 검출 센서를 위한 PbO 박막의 소결효과에 대한 연구)

  • Jung, Suk-Hee;Kim, Yoon-Suk;Kim, Young-Bin;Kim, Min-Woo;Oh, Kyung-Min;Yun, Min-Seok;Nam, Sang-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.3
    • /
    • pp.37-40
    • /
    • 2009
  • In this study, we made a high efficiency x-ray detecting sensor using the lead oxide(PbO) that are used in direct method of x-ray detector. PbO with nano size particles is produced by sol-gel method for high efficiency. The produced PbO with nano size is deposited on ITO(Induim Tin Oxide) glass in several temperature using the PIB(particle-in-binder) method. The thickness of the deposited PbO is about $200{\mu}m$. Through the measurement of dark current, sensitivity and SNR(Signal To Noise Ratio), an electrical properties of the produced PbO film are analyzed. Therefore, we show that an electrical properties are changed according to a temperature and that the PbO film that was treated at $500^{\circ}C$ in O2 atmosphere is the most high efficiency x-ray detecting sensor.

  • PDF

A l0b 150 MSample/s 1.8V 123 mW CMOS A/D Converter (l0b 150 MSample/s 1.8V 123 mW CMOS 파이프라인 A/D 변환기)

  • Kim Se-Won;Park Jong-Bum;Lee Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.1
    • /
    • pp.53-60
    • /
    • 2004
  • This work describes a l0b 150 MSample/s CMOS pipelined A/D converter (ADC) based on advanced bootsuapping techniques for higher input bandwidth than a sampling rate. The proposed ADC adopts a typical multi-step pipelined architecture, employs the merged-capacitor switching technique which improves sampling rate and resolution reducing by $50\%$ the number of unit capacitors used in the multiplying digital-to-analog converter. On-chip current and voltage references for high-speed driving capability of R & C loads and on-chip decimator circuits for high-speed testability are implemented with on-chip decoupling capacitors. The proposed AU is fabricated in a 0.18 um 1P6M CMOS technology. The measured differential and integral nonlinearities are within $-0.56{\~}+0.69$ LSB and $-1.50{\~}+0.68$ LSB, respectively. The prototype ADC shows the signal-to-noise-and-distortion ratio (SNDR) of 52 dB at 150 MSample/s. The active chip area is 2.2 mm2 (= 1.4 mm ${\times}$ 1.6 mm) and the chip consumes 123 mW at 150 MSample/s.

A study on the improved de-interlacing applying third order spline interpolation for horizontal direction and ELA (수평방향의 3차 스플라인 보간과 ELA을 이용한 개선된 디인터레이싱 연구)

  • Baek, Kyung-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.696-701
    • /
    • 2017
  • This paper proposes an improved de-interlacing method that converts interlaced images into progressive images from one field. First, it calculates inter-pixel values applying third-order spline interpolation for the horizontal direction from four upper lower pixel values of missing pixels. From inter-pixel values obtained from spline interpolation and upper lower pixels with value, the proposed method makes an accurate estimate of the direction by applying the correlation between upper and lower pixels. The correlation between upper and lower pixels is calculated in nine directions of a missing pixel by using values obtained from spline interpolation and pixels with value. The direction of an edge is determined as the direction in which the correlation between upper and lower pixels is at its minimum. Thus, a missing pixel is calculated by taking the average of upper lower pixels obtained from the predicted direction of an edge. From the simulation results, there are problems in that it takes a bit more time for processing, but it is expected that the time problem will be improved by increasing CPU processing speed. As for image quality, it is shown that the proposed method improves both subjective and objective image quality and quantitatively improves picture signal-to-noise ratio (PSNR) in the range between 0.1 dB to 0.5 dB, as compared with previously presented de-interlacing methods.

Frequency stabilization of 1.5μm laser diode by using double resonance optical pumping (이중공명 광펌핑을 이용한 1.5μm 반도체 레이저 주파수 안정화)

  • Moon, Han-Sub;Lee, Won-Kyu;Lee, Rim;Kim, Joong-Bok
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.193-199
    • /
    • 2004
  • We present the double resonance optical pumping(DROP) spectra in the transition 5P$_{3}$2/-4D$_{3}$2/ and 5P$_{3}$2/-4D$_{5}$ 2/ of ($^{87}$ Rb) and the frequency stabilization in the $1.5mutextrm{m}$ region using those spectra. Those spectra have high signal-to-noise ratio and narrow spectral linewidth, which is about 10 MHz. We could account fur the relative intensities of the hyperfine states of those spectra by the spontaneous emission into the other state. When the frequency of the $1.5mutextrm{m}$ laser diode was stabilized to the DROP spectrum, the frequency fluctuation was about 0.2 MHz fDr sampling time of 0.1 s and the Allan deviation(or the square root of the Allan variance) was about 1${\times}$10$^{-11}$ for averaging time of l00s.

Study on the Residue Analysis of Organophosphorus and Organochlorine Pesticides with Ion Trap and Quadrupole Mass Spectrometer (Ion Trap Mass Spectrometer와 Quadrupole Mass Spectrometer를 이용한 유기인제 및 유기염소제 농약 분석에 관한 연구)

  • Rhee, Jae-Seong;Park, Hyun-Mee;Er, Yon-Woo
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.12
    • /
    • pp.902-909
    • /
    • 1995
  • Detection limit as well as calibration curves on organophosphorus pesticide(dimethoate, diazinon, parathion-methyl, fenitrothion, malathion) and BHCs were measured for evaluation of utility on qualitative or quantitative analysis of pesticides with ion Trap mass spectrometer and quadrupole mass spectrometer. As ionization source, EI and CI were adopted for qualitative analysis of pesticides by comparison of each fragmentation pattern. At the same time, the utility as trace analysis techniques through scan or selected ion monitoring(SIM) mode was evaluated. With ion trap for all pesticides, detection limit(DL, 1 ${\mu}L$ injection) on scan mode was ranged 0.008∼0.225 ng at signal to noise ratio 3. With quadrupole DL on scan mode was ranged 0.23∼3.1 ng over 0.032∼0.68 ng on SIM mode. The calibration curve with ion trap generated good linearity over 0.99 as correlation coefficient. As clean up procedure, Bio Beads S-X3 was used for the separation of oils from five organophosphorous pesticides in flour extractant showing more than 80% as recovery at most cases. In case of BHCs in jinseng with Florisil column, the recovery of pesticides has been 60% to 90%.

  • PDF

Optimal HPLC Condition for Simultaneous Determination of Anthocyanins in Black Soybean Seed Coats (검정콩 함유 안토시아닌의 동시분석을 위한 최적 HPLC 분석 조건)

  • Choung, Myoung-Gun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.53 no.4
    • /
    • pp.359-368
    • /
    • 2008
  • Black soybean has been widely utilized as foods and oriental medicinal materials. The pigmentation in the seed coat of black soybean is due to accumulate anthocyanins in the epidermis palisade layer. The anthocyanins of black soybean seed coat are considered as a parameter of quality evaluation of black soybean. Therefore, the purpose of this study was to investigate the most suitable HPLC condition for simultaneous determination of anthocyanins in black soybean seed coats extracts. The efficient HPLC analytical condition of D3G, C3G, and Pt3G contained extracts of black soybean seed coats was developed. The gradient elution employed a $250\;mm\;{\times}\;4.6\;mm$ i.d. YMC-pak ODS-AM 303 column. The gradient system was used two mobile phases. A gradient elution was performed with mobile phase A, consisting of 5% aqueous formic acid, and mobile phase B, comprising 5% formic acid - acetonitrile, and delivered at a flow rate of 0.7 mL/min as follows: $0{\sim}35\;min$, $90%\;A{\sim}60%\;A$; 36 min, 90% A; 46 min, 90% A. The UV-VIS. detection wavelength was set at 520 nm. The limit of detection (LOD) for D3G, C3G, and Pt3G were under 10 ng/mL.