• Title/Summary/Keyword: Signal of AE RMS Voltage

Search Result 11, Processing Time 0.03 seconds

Tool Life Monitoring using AE Signal in Gear Shaping (기어가공식 AE 신호를 이용한 공구수명의 감시)

  • 최성필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.130-134
    • /
    • 1996
  • The characteristics of AE(Acoustic Emission) signal is related to cutting conditio, tool material, and tool geometry in metal cutting. The relation between AE signal and tool life was investigated experimentally. Experiment is carried out by gear shaping and SCM 420 workpiece. AE RMS voltage were increased according totool wear. It is suggested that maximum value of AE RMS voltage is an effective parameter to monitor tool life.

  • PDF

Monitoring of Tool Wear using AE Signal in Interrupted cutting (단속절삭에서 AE신호를 이용한 공구마멸의 감시)

  • 김정석
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.6 no.2
    • /
    • pp.112-118
    • /
    • 1997
  • Characteristics of AE(Acoustic Emission) signal is related to cutting conditions, tool materials, and tool geometry in metal cutting. Relation between AE signal and tool wear was investigated experimentally. Experiment is carried out by interrupted cutting for SCM420 workpiece with TiN coating tool on HSS material. AE RMS voltage and count per event were increased according to tool wear. The major results are as follows : 1) AE RMS value is nearly constant as cutting speed changes, but is rapidly increase as feed rate increases. 2) AE RMS value and Count per Event increase as tool wear increases. 3) It is more effective to monitor tool wear by Incremental rate of AE RMS value than by Incremental rate of count per event.

  • PDF

Acoustic Emission Monitoring of Incipient Failure in Journal Bearings( III ) - Development of AE Diagnosis System for Journal Bearings - (음향 방출을 이용한 저어널 베어링의 조기 파손 감지(III) -저어널 베어링 AE 진단 시스템 개발-)

  • Chung, Min-Hwa;Cho, Yong-Sang;Yoon, Dong-Jin;Kwon, Oh-Yang
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.3
    • /
    • pp.155-161
    • /
    • 1996
  • For the condition monitoring of the journal bearing in rotating machinery, a system for their diagnosis by acoustic emission(AE) was developed. AE has been used to detect abnormal conditions in the bearing system. It was found from the field application study as well as the laboratory experiment using a simulated journal bearing system that AE RMS voltage was the most efficient parameter for the purpose of current study. Based on the above results, algorithms and judgement criteria for the diagnosis system was established. The system is composed of four parts as follows: the sensing part including AE sensor and preamplifier, the signal processing part for RMS-to-DC conversion to measure AE ms voltage, the interface part for transferring RMS voltage data into PC using A/D converter, and the software part including the graphic display of bearing conditions and the diagnosis program.

  • PDF

Detection of Built-up Edge by AE Signal Analysis (AE 신호 분석에 의한 구성인선의 감지)

  • Oh, Min-Seok;Won, Jong-Sik;Jung, Youn-Gyo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.18-24
    • /
    • 1999
  • ThisPaper investigates the feasibility of using acoustic emission signal analysis for the detection of built-up edge during machining. Experiments were conducted on a CNC-lathe using conventional carbide insert tools under various cutting conditions. The cutting forces were also measured for comparisons. Experimental evidence is presented which indicates that the presence of a built-up edge can significantly affect the generation of acoustic emission in metal cutting. It is shown that under conditions in which a built-up edge is generated, the variation of $AE_{rms}$ signal with cutting speed can be quite different from the generally accepted linear, monotonic increase as previously reported. The feasibility of utilizing $AE_{rms}$ in built-up edge sensing is suggested.

  • PDF

Detection of B.U.E. by AE signal analysis (AE 신호 분석에 의한 구성인선의 감지)

  • 오민석;원종식;정윤교
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.259-264
    • /
    • 1995
  • Recently, in order to achieve high flexibilty, monitoring and control strategies of a new type have been developed. This paper investigates the fesability of using scoustic emission signal analysis for the detection of built-up edge during machining. Results for maching SM45C steel show that the presence of a built-up edge can significantil affect the generation of acoustic emission in metal cutting. When the cutting speed comes to the conditions conducive to development of built-up edge, it is shown that the slope of curve-fitted AErms signal undergoes a change. The fesability of utilizing AErms in built-up edge sensing is sugested.

  • PDF

Development of Fiber-Optic AE Sensor for On-Line Monitoring System (광섬유를 이용한 상시감시 시스템용 음향방출센서의 개발)

  • Nam, Jae-Yeong;Jeong, Jae-Hyeon;Choe, Jae-Bung;Kim, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.12
    • /
    • pp.2891-2898
    • /
    • 2000
  • The objective of this paper is to develop a fiber-optic acoustic emission(AE) sensor applicable to on-line monitoring systems which is suitable for long-distance signal transmission. An AE sensor was developed by use of a fiber-optic cantilever and an extrinsic Fabry-Perot interferometer(EEPI). The efficiency of signal processing was improved by driving the high frequency AE signals into the low frequency ones. In order to verify the developed sensor, the tensile and the pencil lead fracture(PLF) tests were performed including the experiment showing the Kaiser effect. Form tests, AE signals were successfully detected in the elastic-plastic deformation range, especially higher signals at the crack propagation. The developed sensor was expected to be used for an on-line monitoring of crack propagation in mechanical system.

A Study on the Cutting Characteristics in the Machining of SKD11 by Face Milling (난삭재인 SKD11의 정면밀링 가공시 절삭특성에 관한 연구)

  • 김형석;문상돈;김태영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.73-78
    • /
    • 1994
  • Wear and fracture mode of ceramic tool for hardened SKD11 steel was investigated by face milling in this study. The cutting force and Acoustic Emission(AE) signal were utilized to detect the wear and fracture of ceramic tool. The following conclusions were obtained : (1) The wear and fracture modes of ceramic tool are characterized by three types: \circled1wear which has normal wear and notch wear, \circled2 wear caused by scooping on the rake face, \circled3 large fracture caused by thermal crack in the rake face. (2) The wear behaviour of ceramic tool can be detected by the increase of mean cutting force and the variation of the AE RMS voltage. (3) The catastrophic fracture of ceramic tool can be detected by the cutting force(Fz-component). (4) As the hardness of work material increased, Acoustic Emission RMS value and mean cutting force(Fz) increased linearly, but the tool life decreased.

  • PDF

Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves (발전용 밸브누설 음향 진단 및 감시시스템)

  • Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

A Study on the Application of Acoustic Emission Measurement for the In-process Detection of Milling Tools' Wear and Chipping (밀링 공구마멸과 치핑의 검출을 위한 음향방출 이용에 관한 연구)

  • Yoon, J.H.;Kang, M.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.1
    • /
    • pp.31-37
    • /
    • 1991
  • Acoustic emission(AE) signals detected during metal cutting were applied as the experimental test to sensing tool wear and chipping on the NC vertical milling machine. The in-process detection of cutting tool wear including chipping, cracking and fracture has been investigated by means of AE in spite of vibration or noise through intermittent metal cutting, then the following results were obtained 1) When the tool wear is increased suddenly, or the amplitude of AE signals changes largely, it indicates chipping or breaking of the insert tip. 2) It was confirmed that AE signal is highly sensitive to the cutting speed and tool wear. 3) At the early period of cutting, the wear were large and RMS value increased highly by the influence of minute chipping and cracking, etc. Therefore, the above situations should be considered for the time when the tool would be changed.

  • PDF

Study on the Comparison of Piezoelectric Property of Acoustic Sensor for Valve Leak Diagnosis (밸브누설 진단용 PZT 및 Pb-Free 음향센서의 압전특성 비교 연구)

  • Lee, Sang-Guk;Park, Sung-Keun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3383-3388
    • /
    • 2007
  • To compare the sensor performance of AE leak diagnosis system which can measure valve leak conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured on valve of the simulated test system for power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, pressure difference, valve size and fluid using both piezoelectric acoustic emission sensor and Pb-Free acoustic emission sensor. The results of this study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve.

  • PDF