• 제목/요약/키워드: Signal detector

검색결과 997건 처리시간 0.022초

Confirmation Method of Target Detection for Vehicle Mounted Metal Detector

  • Jung, Byung-Min;Shin, Beom-Su;Chang, YuShin;Yang, DongWon
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권10호
    • /
    • pp.49-54
    • /
    • 2016
  • In this paper, the confirmation method of target detection for the vehicle mounted metal detector (MD) has been described. The vehicle mounted MD with the arrayed 6 coils to detect the width of 2.4 m was demonstrated. It is important and necessary to inform the location of the objects detected by the MD. The confirmation method of target detection was verified by using the MD GUI and the analysis of the receive signal processing. The receive signal processing is performed by comparing the threshold and the difference of the signal calibrated at initial location and the signal detected at present location.

가산성과 신호 의존성 잡음이 있을 때의 신호 검파 방식 (A Detection Scheme in Additive and Signal-Dependent Noise)

  • 김상엽;김선용;박성일;손재철;송익호;윤진선;최진호
    • 한국통신학회:학술대회논문집
    • /
    • 한국통신학회 1991년도 추계종합학술발표회논문집
    • /
    • pp.107-110
    • /
    • 1991
  • When the noise has both additive and signal-dependent components, locally optimum detector test statistics are obtained for detection of weak composite signals using the generalized Neyman-Pearson lemma. In order to consider the non-additive noise as well as purely-additive noise, a generalized observation model is used in this paper. The locally optimum detector test statistics are derived for several different cases according to the relative strengths of the known signal component, the random signal component, and the signal-dependent noise component. Schematic diagrams of the locally optimum detector structures are also included.

혼성 신호 회로에 대한 효과적인 BIST (An Efficient BIST for Mixed Signal Circuits)

  • 방금환;강성호
    • 대한전자공학회논문지SD
    • /
    • 제39권8호
    • /
    • pp.24-33
    • /
    • 2002
  • 혼성 신호 회로의 설계에 있어 저비용의 고효율 테스트 효율을 보장하기 위해 테스트의 노력은 계속되어 왔다. 특히 테스트를 고려한 BIST(built-in-self-test)설계 방법으로 발전해가고 있는 추세인데, 회로상에서 전체적인 테스트 용이도와 분석에 있어 보다 향상된 방법으로 접근할 수 있고 이러한 시스템에 대해 분석하는데 수월하게 할 수도 있다. 이 논문에서는 효과적인 테스트를 위한 방법을 위해 DC전압과 전압 위상에 대한 BIST를 구현하는 것을 제안하였다. 즉 정상적인 회로와 고장회로에서의 동작에서 전압과 위상의 차이를 검출하는 회로를 하드웨어상으로 구성함으로써 비용과 시간 등을 효과적으로 줄이는 방법을 제안하였다. 실험 결과에서는 기존의 BIST와 비교하여 향상된 것을 나타낸다.

교통신호의 자동최적점제어를 위한 마이크로파 FM-CW 검지계통에 관한 연구 (A Study on Microwave-FM-CW Detection System for the Sutomatic Optimal Point Traffic Control)

  • 양흥석;김호윤
    • 전기의세계
    • /
    • 제22권1호
    • /
    • pp.35-41
    • /
    • 1973
  • An automatic point traffic control method is recommended for more idealistic traffic flow over coarse road netowrks. The automatic control apparatus recommended, consists of a transceiver, amplifier, digital-to-analog converter, signal light controller for emergency and steady state, and digital counter as monitor. The transmitter sends a signal to the target vy means of Microwave-FM-CW and a diode detector picks up the echo signal. Thus the operation of the entire system will be carried out through an open loop state. Some factors necessary for an ideal detector system are rapid response, longevity and stability. An analytical method of the Doppler effect substitutes the conventional frequency deviation into the amplitude of detector output. The changing rate of amplitude is proportional to the voltage of the detector output. Some induced formula from Maxwell's radiation field theory ensures this new method, and, new method, and proves the fact with an experimental data presentation. Stability depends upon Klystron as an oscillator and a diode as a detector. the transceiver installation affects on the response and sensitivity of the system. In accordance with the detector output, several targets are easily classified by amplitudes on the scope. The traffic flow, i.e., target movement which is analyzed by the amplitude method, is shown through the scope and indicates it on the digital counter. The best efficiency for the amplitude analysis can be attained through use of an antenna having the highest sensitivity.

  • PDF

약한 다진 신호에 알맞은 결정 기준: 2부. 초광대역 다중접속 시스템에의 응용 (Decision Criterion for Weak M-ary Signals: Part 2. Application to UWB Multiple Access Systems)

  • 오종호;이주미;배진수;구진규;송익호
    • 한국통신학회논문지
    • /
    • 제31권1C호
    • /
    • pp.1-7
    • /
    • 2006
  • 이 논문에서는, 약한 다진 신호에 알맞도록 1부에서 제안한 검파기준을 바탕으로 간섭이 충격성일 때 초광대역 다중접속 시스템에 알맞은 검파 기법을 살펴본다. 제안한 검파기는 최대 비슷함 검파기준을 바탕으로 한 최적 검파기와 견주어 볼 때 얼개가 더 간단하고 성능이 거의 같다. 한편, 간섭이 충격성일 때, 제안한 검파기는 정규 환경에 최적화된 검파기보다 성능이 더 좋다는 것도 보인다.

전압 이중 검출법에 의한 독립형 엔진-발전기 시스템 응답특성 개선 (Dynamic Response Improvement of Stand Alone Engine-Generator System using Double Voltage Detection Method)

  • 이동희;안진우
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1195-1199
    • /
    • 2008
  • In this paper, peak detector of generator's output voltage and variable gain controller are introduced for a fast dynamic response. The conventional r,m.s, signal detected has inherent time delay, and the dynamic response of generator using conventional PID controller has some problem in sudden load change. In this paper, the peak detector and signal selector with variable gain controller is used to overcome this problem. The main controller can check the voltage state from the peak detector. When a sudden load change, the over-voltage and under-voltage signal from peak detector change the controller's gain and exciter's current reference. The proposed scheme can improve the dynamic response, which is verified from experimental test of 200kW diesel engine-generator.

Detection of the Ultrasonic Signals due to Partial Discharges in a 154kV Transformer

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권6호
    • /
    • pp.297-303
    • /
    • 2002
  • We have developed an on-line ultrasonic detector to monitor partial discharge in an operating transformer. The ultrasonic sensor has 150[KHz] resonance frequency and contains a pre-amplifier with 60[㏈] gain. The on-line ultrasonic detector has 50~300[KHz] frequency band-pass filter to remove electrical and mechanical noises from the transformer. This detector has an ultrasonic signal discrimination algorithm which discriminates ultrasonic signals due to partial discharge in a transformer. A moving average method of ultrasonic signal number was employed to effectively monitor the increasing trend of the partial discharge. This paper describes an experience of partial discharge detection in a 154[㎸] operating transformer using an ultrasonic detector. With regards to gas analysis in oil, C2H2 gas was produced with a warning level in this transformer We detected ultrasonic signals on the transformer steel wall, and estimated the position of partial discharge. With further inspection, we found carbonized marks due to partial discharge on the supporting bolt which fastens the windings.

다목적 수동형 라돈농도 측정기 개발 (Development of A Multipurpose Passive Type Radon Monitor)

  • 이봉재;박영웅
    • 동위원소회보
    • /
    • 제21권4호
    • /
    • pp.55-65
    • /
    • 2006
  • A passive type radon monitor adopting two silicon PIN detector as radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this instrument has been performance-tested by using reference radon concentration and a reference photon radiation field. As a result, in a electronic performance test, radiation signals from each detector were well observed in each signal processing circuit. The radiation detection sensitivity of this instrument after several test-irradiations to a Cs-137 gamma radiation source and a standard radon concentration appeared to be 1.37 cph/$\mu$Svh-1 and 1.66 pCi/L respectively. The developed radon monitor in this paper could be used conveniently in monitoring of radon concentration in buildings which population utilize in Korea.

  • PDF

Phase Difference Detector for Satellite Tracking Based on Field Experiments of COMETS

  • Ta, Masuhisa;Nakajima, Isao;Juzoji, Hiroshi
    • Journal of Multimedia Information System
    • /
    • 제5권3호
    • /
    • pp.155-162
    • /
    • 2018
  • Nowadays, the tracking technology of Quadrant Detector will become actual by new micro devices. Based on the past filed data of the reception experiment with COMETS satellite, we have studied on new device (AD8302, phase difference detector) was acquired and suspect its abilities. In 1998, we have developed a Quadrant Detector for mobile to track a weak signal from satellite on Ka band of COMETS. The Quadrant Detector is comprised of four dedicated feed components for reception under an environment of Nakagami - Rician fading, and one transmission and reception feed component. We were successful in receiving a 23 GHz beacon signal from ICE transponder of the COMETS and succeeded in tracking the satellite from a moving vehicle at speeds of approximately 10 ~ 20 Km/h on paved roads. In 2018, with new device AD8302, we have verified new QD system and performed a simulation, based on the past filed experiment. This new device shall be improving the tracking abilities from mobile body on the earth to the multimedia satellite.

A New Formula to Predict the Exact Detection Probability of a Generalized Order Statistics CFAR Detector for a Correlated Rayleigh Target

  • Kim, Chang-Joo
    • ETRI Journal
    • /
    • 제16권2호
    • /
    • pp.15-25
    • /
    • 1994
  • In this paper we present a new formula which can predict the exact detection probability of a generalized order statistics (GOS) constant false alarm rate (DFAR) detector for a partially correlated Rayleigh target model (0 < $ \rho$< 1) in a closed form, where $\rho$ is the correlation coefficient between returned pulses. By simply substituting a set of specific coefficient into the derived formula, one can obtain the detection probability of any kind of CFAR detector. Detectors may include the order statistics CFAR detector, the censored mean level detector, and the trimmed mean CFAR detector, but are not necessarily restricted to them. The numerical result for the first order Markov correlation model as applied to some of the detectors shows that as $\rho$ increases from zero to one, higher signal-to-noise ratio is required to achieve the same detection probability.

  • PDF