• Title/Summary/Keyword: Signal current

Search Result 2,707, Processing Time 0.036 seconds

A study on DSP based power analyzing and control system by analysis of 3-dimensional space current co-ordinates (3차원 전류좌표계 해석법에 의한 DSP 전력분석 제어장치에 관한 연구)

  • 임영철;정영국;나석환;최찬학;장영학;양승학
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.543-552
    • /
    • 1996
  • The goal of this paper is to developed a DSP based power analyzing and control system by 3-Dimensional (3-D) space current co-ordinates. A developed system is made up of 486-PC and DSP (Digital Signal Processor) board, Active Power Filter, Non-linear thyristor load, and Power analyzing and control program for Windows. Power is analyzed using signal processing techniques based on the correlation between voltage and current waveforms. Since power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm, flexibility of the proposed system which has both power analysis mode and control mode, is greatly enhanced. Non-active power generated while speed of induction motor is controlled by modulating firing angle of thyristor converter, is compensated by Active Power Filter for verifying a developed system. Power analysis results, before/after compensation, are numerically obtained and evaluated. From these results, various graphic screens for time/frequency/3-D current co-ordinate system are displayed on PC. By real-time analysis of power using a developed system, power quality is evaluated, and compared with that of conventional current co-ordinate system. (author). refs., figs. tabs.

  • PDF

A Study on Signal Processing Method for Welding Current in Automatic Weld Seam Tracking System (용접선 자동추적시 용접전류 신호처리 기법에 관한 연구)

  • 문형순;나석주
    • Journal of Welding and Joining
    • /
    • v.16 no.3
    • /
    • pp.102-110
    • /
    • 1998
  • The horizontal fillet welding is prevalently used in heavy and ship building industries to fabricate the large scale structures. A deep understanding of the horizontal fillet welding process is restricted, because the phenomena occurring in welding are very complex and highly non-linear characteristics. To achieve the satisfactory weld bead geometry in robot welding system, the seam tracking algorithm should be reliable. The number of seam tracker was developed for arc welding automation by now. Among these seam tracker, the arc sensor is prevalently used in industrial robot welding system because of its low cost and flexibility. However, the accuracy of arc sensor would be decreased due to the electrical noise and metal transfer. In this study, the signal processing algorithm based on the neural network was implemented to enhance the reliability of measured welding current signals. Moreover, the seam tracking algorithm in conjunction with the signal processing algorithm was implemented to trace the center of weld line. It was revealed that the neural network could be effectively used to predict the welding current signal at the end of weaving.

  • PDF

Estimation on the Future Traffic Volumes and Analysis on Information Value of Tidal Current Signal in Incheon (인천항의 장래 교통량 추정 및 조류신호의 정보가치 분석)

  • Kim, Jung-Hoon;Kim, Se-Won;Gug, Seung-Gi
    • Journal of Navigation and Port Research
    • /
    • v.31 no.6
    • /
    • pp.455-462
    • /
    • 2007
  • This paper estimated the future traffic volume incoming and outgoing in Incheon port, and analyzed the value of information serviced by tidal current signal operation center in Incheon. The cargo traffic in 2020 will increase twice as much as in 2005 according to the national ports basis plan. The maritime traffic will increase greatly consequently. Also, MOMAF has operated tidal current signal operation center to prevent marine accidents caused by current influence on vessels navigating through Incheon. However the quantitative effect is not known because there is no analysis about its value. Therefore the value of information serviced by tidal current signal operation center in Incheon was calculated with contingent valuation method(CVM), and the information value was analyzed considering future traffic in this study. Thus, the annual information value was calculated at about $170{\sim}280$ million won, considered traffic volume using the information of tidal current directly in 2020 since 2006.

Estimation of Delta Winding Current and Its Application to a Compensated-Current-Differential Relay for a Y-Δ Transformer

  • Kang, Yong-Cheol;Lee, Byung-Eun;Jin, En-Shu
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.255-263
    • /
    • 2010
  • The compensated-current-differential relay uses the same restraining current as a conventional relay, but the differential current is modified to compensate for the effects of the exciting current. Delta winding current is necessary to obtain the modified differential current for a $Y-\Delta$ transformer. This paper describes an estimation algorithm of the delta winding current and its application to a compensated-current-differential relay for a $Y-\Delta$ transformer. Prior to saturation, the core-loss current is calculated and used to modify the differential current. When the core first enters saturation, the initial value of the core flux is obtained by inserting the modified differential current into the magnetization curve. This flux value is used to derive the magnetizing current and consequently the modified differential current. The operating performance of the proposed relay was compared against a conventional current differential relay with harmonic blocking. Test results indicate that the proposed relay remained stable during severe magnetic inrush and over-excitation, and its operating time is significantly faster than a conventional relay. The relay is unaffected by the level of remanent flux and does not require an additional restraining or blocking signal to maintain stability. This paper concludes by implementing the proposed algorithm into a prototype relay based on a digital signal processor.

A Noise Reduction Method with Linear Prediction Using Periodicity of Voiced Speech

  • Sasaoka, Naoto;Kawamura, Arata;Fujii, Kensaku;Itoh, Yoshio;Fukui, Yutaka
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.102-105
    • /
    • 2002
  • A noise reduction technique to reduce background noise in corrupted voice is proposed. The proposed method is based on linear prediction and takes advantages of periodicity of voiced speech. A voiced sound is regarded as a periodic stationary signal in short time interval. Therefore, the current voice signal is correlated with the voice signal delayed by a pitch period. A linear predictor can estimate only the current signal correlated with the delayed signal. Therefore, the enhanced voice can be obtained as output of the linear predictor. Simulation results show that the proposed method is able to reduce the background noise.

  • PDF

A Study on a Displacement Measurement Method of Magnetic Levitation System Applying the Inductance Characteristic (인덕턴스 특성을 이용한 자기부상계의 변위 측정의 한 방법에 관한 연구)

  • 김창화;양주호
    • Journal of KSNVE
    • /
    • v.6 no.3
    • /
    • pp.357-362
    • /
    • 1996
  • The magnetic levitation system has great advantages, such as little friction, no lubrication, no noise and so on. But the magnetic levitation system need a stabilizing controller because it is a unstable, system in natural and it need a sensor for displacement measurement to control the system. In this paper, we proposed a sensorless method to measure the gap between the magnetic pole and the levitated object with application the inductance characteristic which vary according to gap. We made a driving circuit which supply simultaneously the control input PWM(Pulse Width Modulation) signal and the carrier PWM signal to estimate the gap. Because the inductance is a function of gap, and the current of the carrier signal is a function of the inductance, we could estimate the gap from the measurement of the current of the carrier signal. Finally, we investigated the validity of the proposed method through the experimental results.

  • PDF

Analog Signal Conditioner Using Fuzzy Logic Technique

  • Maipradith, N.;Riewruja, V.;Chaikla, A.;Julsereewong, P.;Ukakimaparn, P.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.472-472
    • /
    • 2000
  • An analog signal conditioner using fuzzy logic technique, which has multiple-input and multiple-output terminals, is proposed in this paper. The proposed signal conditioner can be employed to linearly translate the level of signals to a standard voltage signal (1-5V) and convert the form of signals to a standard current signal (4-20mA). The implementation method based on the use of a commercial 8-bit microcontroller, the analog-to-digital (A/D) converters, the digital-to-analog (D/A) converters and the voltage-to-current (V/I) converter. The simulation result and the experimental results are presented, which further confirm the feasibility of this approach.

  • PDF

Effect of Calmodulin on Ginseng Saponin-Induced $Ca^{2+}$-Activated $Cl^{-}$ Channel Activation in Xenopus laevis Oocytes

  • Lee Jun-Ho;Jeong Sang-Min;Lee Byung-Hwan;Kim Jong-Hoon;Ko Sung-Ryong;Kim Seung-Hwan;Lee Sang-Mok;Nah Seung-Yeol
    • Archives of Pharmacal Research
    • /
    • v.28 no.4
    • /
    • pp.413-420
    • /
    • 2005
  • We previously demonstrated the ability of ginseng saponins (active ingredients of Panax ginseng) to enhance $Ca^{2+}$-activated $Cl^{-}$ current. The mechanism for this ginseng saponin-induced enhancement was proposed to be the release of $Ca^{2+}$ from $IP_{3}-sensitive$ intracellular stores through the activation of PTX-insensitive $G\alpha_{q/11}$ proteins and PLC pathway. Recent studies have shown that calmodulin (CaM) regulates $IP_{3}$ receptor-mediated $Ca^{2+}$ release in both $Ca^{2+}-dependent$ and -independent manner. In the present study, we have investigated the effects of CaM on ginseng saponin-induced $Ca^{2+}$-activated $Cl^{-}$ current responses in Xenopus oocytes. Intraoocyte injection of CaM inhibited ginseng saponin-induced $Ca^{2+}$-activated $Cl^{-}$ current enhancement, whereas co-injection of calmidazolium, a CaM antagonist, with CaM blocked CaM action. The inhibitory effect of CaM on ginseng saponin-induced $Ca^{2+}$-activated $Cl^{-}$ current enhancement was dose- and time-dependent, with an $IC_{50} of 14.9\pm3.5 {\mu}M$. The inhibitory effect of CaM on saponin's activity was maximal after 6 h of intraoocyte injection of CaM, and after 48 h the activity of saponin recovered to control level. The half-recovery time was calculated to be $16.7\pm4.3 h$. Intraoocyte injection of CaM inhibited $Ca^{2+}$-induced $Ca^{2+}$-activated $Cl^{-}$ current enhancement and also attenuated $IP_{3}$-induced $Ca^{2+}$-activated $Cl^{-}$ current enhancement. $Ca^{2+}$/CaM kinase II inhibitor did not inhibit CaM-caused attenuation of ginseng saponin-induced $Ca^{2+}$-activated $Cl^{-}$ current enhancement. These results suggest that CaM regulates ginseng saponin effect on $Ca^{2+}$-activated $Cl^{-}$ current enhancement via $Ca^{2+}$-independent manner.

침수 누전에 대한 자계 특성

  • Kim, Tak-Yong;Lee, Gyeong-Seop;Kim, Jin-Sa;Kim, Chung-Hyeok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.147-147
    • /
    • 2009
  • Every year respect a countermeasure establishment the electric leakage detection system and electric leakage investigation work are becoming enforcement line plentifully in about the electric leakage accident which is increasing, measuring in compliance with a most ground connection voltage and an image electric current mainly is become accomplished, inputs a pulsation group signal in the line and detects a signal change between the line a method which there is. In order to investigate the quality in compliance with an electric leakage electric current from the electric leakage area after conferring the electric leakage environment in compliance with a flooding when the electric leakage electric current exists in the surface, it investigated the electric leakage electric current quality from the electric current distribution and flooded districts from the present paper.

  • PDF

Design and Implementation of a Current Controller for Boost Converters Using a DSP (DSP를 이용한 부스트 컨버터의 전류 제어기 설계 및 구현)

  • Lee, Kwang-Woon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.259-265
    • /
    • 2012
  • This paper introduces a method for design and implementation of a current controller for boost converter operating in continuous conduction mode (CCM) using a digital signal processor (DSP). A Proportional-Integral (PI) type current controller outputs an average voltage command for inductor, used in the input side of the boost converter, and the duty-ratio of PWM (pulse width modulation) signal for switching device is directly calculated from the average voltage command. The gains of the PI current controller are selected such that the current response characteristics are the same as those of a first-order low-pass filter. The proposed current control scheme is implemented using a DSP based on fixed-point math operations and an experimental study has been performed to validate the proposed method.