• Title/Summary/Keyword: Signal current

Search Result 2,707, Processing Time 0.027 seconds

Soft-Start Open Circuit Voltage and Constant Current Sequence Control of 2.5[kW] HID Search Lamp for Ship (선박용 2.5[kW] HID 탐사등의 Soft-Start 방식에 의한 개방회로 전압과 점등전류 순차 제어)

  • Park, Noh-Sik;Kwon, Soon-Jae;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.8
    • /
    • pp.45-51
    • /
    • 2008
  • HID(High Intensity Discharge) search lamp for shipment requires a high open circuit and output current compare than vehicle. This paper presents a soft-start open circuit voltage and constant current sequence control method for 2.5[kW] HID search lamp. The proposed method controls the opal circuit voltage and discharge current of HID lamp according to ignition signal with a simple 8-bit micro-processor and PWM device. For the stable control of lamp, micro-processor checks the output voltage and current. And the checked signals are compared with ignition signal and changes the control mode for stable operation. An ignition signal and micro-processor change the control mode from open circuit voltage contort to constant current control. The proposed control scheme is verified from experimental tests of 2.5[kW] HID search lamp for shipment.

The Influence of Frequency on Wayside Transmitter of ATP System upon Reinforcing Bars in Concrete Slab Track (콘크리트 슬래브궤도에서 철근이 ATP시스템 지상자의 주파수에 미치는 영향)

  • Kim, Min-Seok;Yoon, In-Mo;Ko, Jun-Seog;Lee, Jong-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.6
    • /
    • pp.536-542
    • /
    • 2008
  • In concrete slab track, the signal current using wayside transmitter of ATP (Automatic Train Protection) system is influenced by reinforcing bars. The magnetic coupling between reinforcing bars and wayside transmitter of ATP system as a filter makes an input current distorted. So, it makes an alternating current signal with a desirable size not transmit to on-board system of a train. Way to decrease the distortion of an input current signal frequency is to avoid maximum induction current frequency. And the induction phenomenon between reinforcing bars insulated and wayside transmitter of ATP system does not occur. In this paper, we represent the model about wayside transmitter of ATP system and reinforcing bars on the concrete slab tracks, and calculated the parameters demanded for the model. Also, we demonstrated it through the Maxwell program. Furthermore, we calculated impedance on wayside transmitter used in KVB system and ERTMS/ETCS system which are a kind of ATP system, frequency response of induction current, using Matlab, and demonstrated the validity of it, using PSpice program.

Measurement of Optogalvanic Signal in Hollow Cathode Discharge Tube (Hollow Cathode Discharge Tube에서의 광검류 신호 측정)

  • Lee, Jun-Hoi;Yoon, Man-Young;Kim, Song-Kang
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.874-877
    • /
    • 2002
  • The optogalvanic signals were measured using hollow cathode discharge tube with argon as buffer gas at change of discharge currents. A change of ionization rate due to electron collision causes an increase or decrease of the electric conductivity. This change in electric conductivity generates the optogalvanic signal. We conclude that optogalvanic signal has close relation with the lowest metastable atoms density at low current.

  • PDF

The Effects of Signal Delay on Scanning Velocity Modulation in CRT

  • Choo, Seong-Hun;Choi, Jong-Hoon;Bae, Min-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.1160-1163
    • /
    • 2003
  • The effects of time delay between a video signal and a current signal applied to velocity modulation coil on free-spot movement and beam size were measured and analyzed quantitatively in this study. The result shows that it is the most important to avoid signal mismatching in order to achieve the optimal velocity modulation performance.

  • PDF

A Low-voltage High-speed PWM signal generation Based on Relaxation oscillator

  • Siripruchyanun, Montree
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.735-738
    • /
    • 2002
  • This paper a new simple PWM (Pulse Width Modulation) signal generation based on modified relaxation oscillator is introduced. Its advantages of the proposed principle are that the precise PWM signal can be easily achieved with a high frequency range up to several megahertz and a low-voltage power supply. The proposed circuit can accept either voltage or current modulating signal. It is very suitable for developing into Integrated Circuits (ICs) form in communication applications. The simulation and experimental results are also depicted, they shown good agreement with theoretical anticipation.

  • PDF

A fully-differential bipolar current-controlled current amplifier(CCCA) (완전-차동형 바이폴라 전류-제어 전류 증폭기(CCCA))

  • 손창훈;임동빈;차형우
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.289-292
    • /
    • 2001
  • A Novel fully-differential bipolar current-controlled current amplifier(CCCA) for electrically tunable circuit design at current-mode signal processing were designed. The CCCA was consisted of fully-differential subtracter and fully-differential current gain amplifier. The simulation result shows that the CCCA has current input impedance of 0.5 Ω and a good linearity. The CCCA has 3-dB cutoff frequency of 20 MHz for the range over bias current 100$mutextrm{A}$ to 20 ㎃. The power dissipation is 3 mW.

  • PDF

Stand-Alone PV System by Parallel Operation Control of Current-Source Inverter without Battery (전류원 인버터의 병렬운전에 의한 축전지 없는 태양광 시스템의 구성)

  • 박성준;김종달
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.6
    • /
    • pp.291-297
    • /
    • 2003
  • This paper presents a current-source-inverter based on a buck-boost configuration and its application for residential photovoltaic system. The proposed circuit has five switches. Among them, only one switch acts as chopping, and the other determine the polarity of output; therefore, it can reduce the switching loss. Because the input inductor current is operated on the discontinuous conduction mode, high power factor can be achieved without additional input current controller. So the overall system shows a simple structure. The operational modes are analysed in depth, and then it was verified through the experimental results using a 150 [W] prototype equipped with digital signal processor TMS320F241.

Low Cost Rotor Fault Detection System for Inverter Driven Induction Motor

  • Kim, Nam-Hun;Choi, Chang-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.500-504
    • /
    • 2007
  • In this paper, the induction motor rotor fault diagnosis system using current signals, which are measured using axis-transformation method, and speed, which is estimated using current information, are presented. In inverter-fed motor drives unlike line-driven motor drives the stator currents have numerous harmonics components and therefore fault diagnosis using stator currents is very difficult. The current and speed signal for rotor fault diagnosis needs to be precise. Also, high resolution information, which means the diagnosis system, demands additional hardware such as low pass filter, high resolution ADC, encoder and etc. Therefore, the proposed axis-transformation and speed estimation method are expected to contribute to low cost fault diagnosis systems in inverter-fed motor drives without the need for an encoder and any additional hardware. In order to confirm validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation using Park transformation and speed estimation method are compared with the results obtained from fast Fourier transforms.

Observation of Negative Resistance Region in Voltage-current Curve of Hollow Cathode Discharge (속이 빈 원통형음극 방전의 전압-전류 곡선에서 음 저항 영역 관찰)

  • Lee, Jun-Hoi;Lee, Sung-Jik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.9
    • /
    • pp.870-875
    • /
    • 2005
  • We measured the optogalvanic signal and discharge voltage-current(V-I) curve under the two different discharge conditions with different buffer gases, Ar, and Ne. When the Gd was used as a cathode material at low discharge current less than 10mA, a significant change was observed in the current-voltage curve. Time resolved optogalvanic signal measurement were measured by the diode laser of which wavelengths correspond to metastable transition line of these gases (Ar, Ne). From these measurements, we found that the characteristics of the V-I curve strongly depend on the Penning ionization process.

A Study on the Average Current-Mode Control AC/DC ZVT-Boost Converter with Active-Clamp Method (능동 클램프 방식을 이용한 AC/DC ZVT 승압형 컨버터의 평균전류모드 제어에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Kim, Pill-Soo;Lim, Nam-Hyuk;Yoon, Suk-Ho;Chang, Sung-Won
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1005-1008
    • /
    • 2001
  • This paper presents average current-mode control AC/DC ZVT(Zero Voltage Transition) Boost Converter. This boost converter perceives feed forward signal of input and feedback signal of output for average current-mode control proposed converter employs active-clamp method for ZVT. This converter gives the good PFC(Power Factor Correction), low line current hormonic distortions and tight output voltage regulations. This converter also has a high efficiency by active-clamp method. The principle of operation, feature, and design considerations are illustrated and verified through the experiment with a 150W, 120kHz prototype converter.

  • PDF