• Title/Summary/Keyword: Signal Compression

Search Result 560, Processing Time 0.025 seconds

Adaptive Sampling for ECG Detection Based on Compression Dictionary

  • Yuan, Zhongyun;Kim, Jong Hak;Cho, Jun Dong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.608-616
    • /
    • 2013
  • This paper presents an adaptive sampling method for electrocardiogram (ECG) signal detection. First, by employing the strings matching process with compression dictionary, we recognize each segment of ECG with different characteristics. Then, based on the non-uniform sampling strategy, the sampling rate is determined adaptively. As the results of simulation indicated, our approach reconstructed the ECG signal at an optimized sampling rate with the guarantee of ECG integrity. Compared with the existing adaptive sampling technique, our approach acquires an ECG signal at a 30% lower sampling rate. Finally, the experiment exhibits its superiority in terms of energy efficiency and memory capacity performance.

Development of Ultrasonic Pulse Compression Using Golay Codes (Golay 코드를 사용한 초음파펄스압축법 개발)

  • Kim, Young-H.;Kim, Young-Gil;Jeong, Peter
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.185-193
    • /
    • 1994
  • Conventional ultrasonic flaw detection system uses a large amplitude narrow pulse to excite a transducer. However, these systems are limited in pulse energy. An excessively large amplitude causes a dielectric breakage of the transducer, and an excessively long pulse causes decrease of the resolution. Using the pulse compression, a long pulse of pseudorandom signal can be used without sacrificing resolution by signal correlation. In the present work, the pulse compression technique was implemented into an ultrasonic system. Golay code was used as a pseudorandom signal in this system, since pair sum of autocorrelations has no sidelobe. The equivalent input pulse of the Golay code was derived to analyze the pulse compression system. Throughout the experiment, the pulse compression technique has demonstrated for its improved SNR(signal to noise ratio) by reducing the system's white noise. And the experimental data also indicated that the SNR enhancement was propotional to the square root of the code length used. The technique seems to perform particularly well with highly energy-absorbent materials such as polymers, plastics and rubbers.

  • PDF

Optical Signal Sampling Based on Compressive Sensing with Adjustable Compression Ratio

  • Zhou, Hongbo;Li, Runcheng;Chi, Hao
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.288-296
    • /
    • 2022
  • We propose and experimentally demonstrate a novel photonic compressive sensing (CS) scheme for acquiring sparse radio frequency signals with adjustable compression ratio in this paper. The sparse signal to be measured and a pseudo-random binary sequence are modulated on consecutively connected chirped pulses. The modulated pulses are compressed into short pulses after propagating through a dispersive element. A programmable optical filter based on spatial light modulator is used to realize spectral segmentation and demultiplexing. After spectral segmentation, the compressed pulses are transformed into several sub-pulses and each of them corresponds to a measurement in CS. The major advantage of the proposed scheme lies in its adjustable compression ratio, which enables the system adaptive to the sparse signals with variable sparsity levels and bandwidths. Experimental demonstration and further simulation results are presented to verify the feasibility and potential of the approach.

Analysis on Code Used in Pulse Compression Method for Improving Resolution of Ultrasound Imaging System (초음파 영상 시스템에서의 해상도 개선을 위한 펄스압축기법에 사용되는 코드에 대한 분석)

  • You, Y.M.;Lee, H.H.;Song, T.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.115-116
    • /
    • 1998
  • Pulse echo techniques have been used for the conventional medical ultrasound imaging systems. However, their resolution is limited in the transmitted signal power. To overcome this limit, pulse compression method used in the radar systems was proposed. This system transmits a continuous coded signal and then compresses the received signal into the short and high resolution pulse by using correlator. The reflectors can be detected by cross-correlation between the transmitted signal and the received signal with the depth information. In this paper, we will present a comparative study of the performances of the most common sequences(pseudo-chirp, m-sequences, modified Golay code). The best result for improving resolution is obtained with the modified Golay Code.

  • PDF

A Study on Joint ATR-Compression System Design Algorithm for Integrated Target Detection (목표물 탐지를 고려한 자동탐색기능 압축시스템 설계 알고리듬에 관한 연구)

  • 남진우
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.1
    • /
    • pp.12-18
    • /
    • 2001
  • SAR radar and FLIR images, which are taken from sensors on aircrafts or satellites, are compressed prior to transmission to facilitate rapid transfer through the limited bandwidth channels. In this case, it is important that it achieves compression ratio as high as possible as well as high target detection rate. In this paper a joint ATR-compression system based on the subband coding and VQ is proposed, which utilizes the encoder as a predictor or classifier for target detection. Simulation result shows that the proposed system achieves a relatively high level of target detection performance as well as a high compression ratio over 200:1.

  • PDF

A Study on the Data Compression of the Voice Signal using Multi Wavelet (다중 웨이브렛을 이용한 음성신호 데이터 압축에 관한 연구)

  • Kim, Tae-Hyung;Park, Jae-Woo;Yoon, Dong-Han;Noh, Seok-Ho;Cho, Ig-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.1
    • /
    • pp.625-629
    • /
    • 2005
  • According to the rapid development of the information and communication technology, the demand on the efficient compression technology for the multimedia data is increased magnificently. In this Paper, we designed new compression algorithm structure using wavelet base for the compression of ECG signal and audible signal data. We examined the efficiency of the compression between 2-band structure and wavelet packet structure, and investigated the efficiency and reconstruction error by wavelet base function using Daubechies wavelet coefficient and Coiflet coefficient for each structure. Finally, data were compressed further more using Huffman code, and resultant Compression Rate(CR) and Percent Root Mean Square difference(PRD) were compared with those of existent DCT.

  • PDF

Improvement of acoustic feedback stability by bandwidth compression and expansion

  • 염동홍;안수길
    • The Journal of the Acoustical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.16-21
    • /
    • 1985
  • Both shifiting the input signal's frequencies by a fixed frequency and compressing the input signal's bandwidth have been known to be effective in improving the stability margin of public adress systems operating in reverberant spaces. This paper describes the effect of an alternative approach of improving the acoustic-feedback stability and yet maintaining speech inteligibility by bandwidth compression and expansion. Conditions are derived for this technizue to be realized and an experimental system has been made - up. A series of experiments has been performed in small spaces and the results have shown that more than 5dB improvement can be obtained in the stability margin.

  • PDF

Medical Image Compression using Adaptive Subband Threshold

  • Vidhya, K
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.499-507
    • /
    • 2016
  • Medical imaging techniques such as Magnetic Resonance Imaging (MRI), Computed Tomography (CT) and Ultrasound (US) produce a large amount of digital medical images. Hence, compression of digital images becomes essential and is very much desired in medical applications to solve both storage and transmission problems. But at the same time, an efficient image compression scheme that reduces the size of medical images without sacrificing diagnostic information is required. This paper proposes a novel threshold-based medical image compression algorithm to reduce the size of the medical image without degradation in the diagnostic information. This algorithm discusses a novel type of thresholding to maximize Compression Ratio (CR) without sacrificing diagnostic information. The compression algorithm is designed to get image with high optimum compression efficiency and also with high fidelity, especially for Peak Signal to Noise Ratio (PSNR) greater than or equal to 36 dB. This value of PSNR is chosen because it has been suggested by previous researchers that medical images, if have PSNR from 30 dB to 50 dB, will retain diagnostic information. The compression algorithm utilizes one-level wavelet decomposition with threshold-based coefficient selection.

An implementation of DWT Encoder design for image compression (영상 압축을 위한 DWT Encoder 설계)

  • 이강현
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.491-494
    • /
    • 1999
  • Introduction of digital communication network such as Integrated Services Digital Networks(ISDN) and digital storage media have rapidly developed. Due to a large amount of image data, compression is the key techniques in still image and video using digital signal processing for transmitting and storing. Digital image compression provides solutions for various image applications that represent digital image requiring a large amount of data. In this paper, the proposed DWT(Discrete Wavelet Transform) filter bank is consisted of simple architecture, but it is efficiently designed that a user obtain a wanted compression rate as only input parameter. If it is implemented by FPGA chip, the designed encoder operates in 12MHz.

  • PDF