• 제목/요약/키워드: Signal Combining

검색결과 485건 처리시간 0.02초

Prediction of Axillary Lymph Node Metastasis in Early Breast Cancer Using Dynamic Contrast-Enhanced Magnetic Resonance Imaging and Diffusion-Weighted Imaging

  • Jeong, Eun Ha;Choi, Eun Jung;Choi, Hyemi;Park, Eun Hae;Song, Ji Soo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제23권2호
    • /
    • pp.125-135
    • /
    • 2019
  • Purpose: The purpose of this study was to evaluate dynamic contrast-enhanced breast magnetic resonance imaging (DCE-MRI), and diffusion-weighted imaging (DWI) variables, for axillary lymph node (ALN) metastasis in the early stage of breast cancer. Materials and Methods: January 2011-April 2015, 787 patients with early stage of breast cancer were retrospectively reviewed. Only cases of invasive ductal carcinoma, were included in the patient population. Among them, 240 patients who underwent 3.0-T DCE-MRI, including DWI with b value 0 and $800s/mm^2$ were enrolled. MRI variables (adjacent vessel sign, whole-breast vascularity, initial enhancement pattern, quantitative kinetic parameters, signal enhancement ratio (SER), tumor apparent diffusion coefficient (ADC), peritumoral ADC, and peritumor-tumor ADC ratio) clinico-pathologic variables (age, T stage, multifocality, extensive intraductal carcinoma component (EIC), estrogen receptor, progesterone receptor, HER-2 status, Ki-67, molecular subtype, histologic grade, and nuclear grade) were compared between patients with axillary lymph node metastasis and those with no lymph node metastasis. Multivariate regression analysis was performed, to determine independent variables associated with ALN metastasis, and the area under the receiver operating characteristic curve (AUC), for predicting ALN metastasis was analyzed, for those variables. Results: On breast MRI, moderate or prominent ipsilateral whole-breast vascularity (moderate, odds ratio [OR] 3.45, 95% confidence interval [CI] 1.28-9.51 vs. prominent, OR = 15.59, 95% CI 2.52-96.46), SER (OR = 1.68, 95% CI 1.09-2.59), and peritumor-tumor ADC ratio (OR = 6.77, 95% CI 2.41-18.99), were independently associated with ALN metastasis. Among clinico-pathologic variables, HER-2 positivity was independently associated, with ALN metastasis (OR = 23.71, 95% CI 10.50-53.54). The AUC for combining selected MRI variables and clinico-pathologic variables, was higher than that of clinico-pathologic variables (P < 0.05). Conclusion: SER, moderate or prominent increased whole breast vascularity, and peritumor-tumor ADC ratio on breast MRI, are valuable in predicting ALN metastasis, in patients with early stage of breast cancer.

CT 촬영 조건에 따른 PET 영상의 변화 (Change of PET Image According to CT Exposure Conditions)

  • 박재윤;김정훈;이용기
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.473-479
    • /
    • 2019
  • 다양한 촬영 조건의 CT 감쇠 지도가 PET 영상에 영향을 미치는지 알아보기 위하여 다양한 kVp와 mA조건에서 Uniformity phantom 영상의 신호 강도(SI; Signal Intensity)와 표준 섭취율 계수(SUV; Standardized Uptake Value)를 측정하고, CTDI (Computed Tomography Dose Index)를 통해 각 조건에 따른 피폭선량을 측정하였다. 또한 동일한 조건에서 Resolution phantom의 반치폭(FWHM; Full Width at Half Maximum)을 측정하여 CT의 kVp와 mA에 따른 PET 영상의 화질 변화에 대하여 정량적으로 알아보고자 하였다. 연구 결과, CT의 촬영 조건은 PET 영상에는 영향을 주지 않는 것으로 나타났으나, CT의 촬영 조건이 감소하게 되면 방사선 피폭이 감소하게 되지만 영상에 영향을 미치게 되므로 향후 진단이 가능한 CT 화질을 유지하면서 방사선 피폭을 최소화할 수 있는 양전자 방출 단층 촬영(PET/CT; Positron Emission Tomography / Computed Tomography)의 촬영 조건에 대한 연구가 지속적으로 되어야 할 것이다.

Feasibility of Three-Dimensional Balanced Steady-State Free Precession Cine Magnetic Resonance Imaging Combined with an Image Denoising Technique to Evaluate Cardiac Function in Children with Repaired Tetralogy of Fallot

  • YaFeng Peng;XinYu Su;LiWei Hu;Qian Wang;RongZhen Ouyang;AiMin Sun;Chen Guo;XiaoFen Yao;Yong Zhang;LiJia Wang;YuMin Zhong
    • Korean Journal of Radiology
    • /
    • 제22권9호
    • /
    • pp.1525-1536
    • /
    • 2021
  • Objective: To investigate the feasibility of cine three-dimensional (3D) balanced steady-state free precession (b-SSFP) imaging combined with a non-local means (NLM) algorithm for image denoising in evaluating cardiac function in children with repaired tetralogy of Fallot (rTOF). Materials and Methods: Thirty-five patients with rTOF (mean age, 12 years; range, 7-18 years) were enrolled to undergo cardiac cine image acquisition, including two-dimensional (2D) b-SSFP, 3D b-SSFP, and 3D b-SSFP combined with NLM. End-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) of the two ventricles were measured and indexed by body surface index. Acquisition time and image quality were recorded and compared among the three imaging sequences. Results: 3D b-SSFP with denoising vs. 2D b-SSFP had high correlation coefficients for EDV, ESV, SV, and EF of the left (0.959-0.991; p < 0.001) as well as right (0.755-0.965; p < 0.001) ventricular metrics. The image acquisition time ± standard deviation (SD) was 25.1 ± 2.4 seconds for 3D b-SSFP compared with 277.6 ± 0.7 seconds for 2D b-SSFP, indicating a significantly shorter time with the 3D than the 2D sequence (p < 0.001). Image quality score was better with 3D b-SSFP combined with denoising than with 3D b-SSFP (mean ± SD, 3.8 ± 0.6 vs. 3.5 ± 0.6; p = 0.005). Signal-to-noise ratios for blood and myocardium as well as contrast between blood and myocardium were higher for 3D b-SSFP combined with denoising than for 3D b-SSFP (p < 0.05 for all but septal myocardium). Conclusion: The 3D b-SSFP sequence can significantly reduce acquisition time compared to the 2D b-SSFP sequence for cine imaging in the evaluation of ventricular function in children with rTOF, and its quality can be further improved by combining it with an NLM denoising method.

DS/CDMA 모뎀 구조와 ASIC Chip Set 개발 (A development of DS/CDMA MODEM architecture and its implementation)

  • 김제우;박종현;김석중;심복태;이홍직
    • 한국통신학회논문지
    • /
    • 제22권6호
    • /
    • pp.1210-1230
    • /
    • 1997
  • 본 논문에서는 기준신호를 나타내는 하나의 파일럿채널과 다수의 트래픽채널을 갖는 DS/CDMA용 송수신기구조를 제안한다. 파일럿채널은 데이타 변조가 되지 않은 순수 PN 부호성분을 전송하며 수신단에서 PN 동기 및 동기복조의 기준신호로 이용한다. 또한 이러한 구조는 순방향뿐만 아니라 역방향 링크에도 적용된다. 제안된 DS/CDMA 방식의 특징은 다음과 같다. 첫째, 트래픽채널의 확산 방식은 I-phase 및 Q-phase의 확산부호를 파일럿채널의 그것과 교차하게 배치한 interlaced quardrature-spreading(IQS) 구조를 갖는데 이는 기존의 확산방식에 비해 데이타 신호의 영교차율을 줄여 송신단 출력신호 레벨의 변화를 작게한다. 둘째, PN부호의 초기동기 및 동기초적시 임계값을 적응적으로 자동설정하며, 초기동기시 PN 부호를 한 칩씩 이동하게 하여, 기존의 방식에 비해 초기동기 시간을 절반으로 줄이게 했으며, 수신부에서 PN 부호 발생기를 하나만 사용하여 초기동기 및 동기추적이 되게했다. 또한 state machine을 이용하여 재동기 timing을 자동설정 하도록 설계했다. 셋째, 본 방식에서는 자동주파수조절(automatic frequency control: AFC)기능, 입력신호의 크기에 따라 능동적으로 유효한 출력 레벨을 조절하는 자동 레벨조절(automatic level control: ALC)기능, bit-error-rate(BER)을 자동계산하는 기능, 인접 채널과의 간섭을 최소화하기 위한 스펙트럼 성형기능 등을 도입하여 사용자 편의를 도모했다. 넷째, 데이타 전송속도를 16Kbps~1.024Mbps로 가변이 되게함으로써 다양한 응용에 대처할 수 있게 설계했다. 한편, 본 논문에서 제안한 DS/CDMA 모뎀구조는 다양한 simulation을 통하여, 알고리즘 검증 과정을 거쳤으며, 제안된 DS/CDMA 모뎀 구조는 VHDL을 이용하여 ASIC으로 구현하였다. DS/CDMA용 ASIC은 송신부 ASIC과 수신부 ASIC으로 나누어 개발 하였으며, 한개의 ASIC당 3개의 채널을 동시에 수용할 수 있으며, 다수의 ASIC을 사용하여 여러 채널의 다중접속이 가능하다. 제작완료된 ASIC은 기능시험을 완료했으며 실제 line-of-sight(LOS) 시스템 구현에 적용중이다.

  • PDF

산악기상관측정보를 이용한 위성정보 기반의 전천후 기온 자료의 평가 - 강원권역을 중심으로 (Evaluation of the Satellite-based Air Temperature for All Sky Conditions Using the Automated Mountain Meteorology Station (AMOS) Records: Gangwon Province Case Study)

  • 장근창;원명수;윤석희
    • 한국농림기상학회지
    • /
    • 제19권1호
    • /
    • pp.19-26
    • /
    • 2017
  • 지표면 기온($T_{air}$ surface air temperature)은 기상 및 기후학 분야에서 대표적인 기상인자일 뿐만 아니라 육상생태계 기능을 조절하는 주요 환경조건 인자이다. MODIS와 같은 인공위성정보 활용 기술은 지표면 기온을 연속적으로 모니터링 할 수 있는 기회를 제공한다. 하지만 복잡 산악지역에서의 관측 정확도의 한계와 구름 등에 의한 자료 결측은 연속적인 모니터링을 제한한다. 이 연구에서는 위성정보를 기반으로 복잡 산악지역에서 인 강원도 지역을 대상으로 전천후 기온정보를 생산하여 산악기상관측자료를 이용하여 평가하였다. 산악지역에 대한 정확도 개선을 위해 Aqua MODIS 기온정보(MYD07_L2)에 대기기온감률 방법을 적용한 결과, 기존보다 약 4% RMSE 개선효과(ME의 경우 95%)가 나타났다. 전천후 기온정보 산출을 위해 MYD07_L2 기온정보와 GCOM-W1 AMSR2 37 GHz 밝기온도 자료간의 픽셀 기반의 회귀모형 방법을 적용하였다. 산악기상 관측 자료와 비교한 결과 전반적으로 좋은 일치도를 보였으나(r=0.80, RMSE=7.9K), 겨울철에 다소 과소모의의 경향을 나타냈다. 그럼에도 불구하고 전체 자료 중 결측되었던 61.4%의 자료(n=2,657)를 복원하여 복잡 산악지역에 대해 위성정보 기반의 전천후 기온정보 생산이 가능함을 확인하였다. 향후 이 연구에서 사용한 간단하고 효과적인 회귀모형 방법은 과거 및 최신 위성정보를 활용을 통한 시공간적인 확장이 가능할 것으로 사료된다.