• Title/Summary/Keyword: Side-coupling

Search Result 246, Processing Time 0.027 seconds

A Study on the Characteristics of Circular Piezoelectric Transformner which has Multi-layered Crescent-Shaped Input Electrode (적층형 Crescent-Shaped Input Type 원형 압전변압기의 특성)

  • Jeong, Seong-Su;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.223-224
    • /
    • 2006
  • This paper present a new disk-type piezoelectric transformer. The input side of the transformer has a crescent-shaped electrode and the output side has a focused poling direction. This transformer has multi-layered structure. The piezoelectric transformers operated m each transformer's resonance vibration mode. The electrodes and poling directions on commercialy available piezoelectric ceramic disks were designed so that the planar or shear mode coupling factor ($k_p,\;k_{15}$) becomes effective rather than the transverse mode coupling factor ($k_{31}$). The Resonance frequency is 65.22[kHz] and maximum voltage step-up ratio is 149. Multi-layered transformer has better efficiency and step-up ratio than the single-layered transformer.

  • PDF

A Study on the Application of Voltage Transformer at Transmission Lines (송전선로측 권선형 변성기 사용에 따른 기술적 고찰)

  • Choi, Ky-Youl;Park, Moon-Bin
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1152-1154
    • /
    • 1999
  • Recently. due to the drastic development of communication method between substations for pilot protective relaying system. The power line carrier(PLC) application is getting obsolete. Consequently, the coupling capacitor voltage transformer (CCVT) loses its necessity for the carrier coupling function, and so wound voltage transformer(VT) can be used to substitute CCVT for voltage signal. However, VT has been reported to give rise to ferro-resonance phenomena, so sufficient consideration on applying the VT to line side is required. This study introduces probable technical problems in using the VT on T/L side, and carries out feasibility study on the basis of modeling results by EMTP(Electro-magnetic transient program)

  • PDF

Design of a Piezoelectric Transformer with Crescent-Shaped Input type (Crescent-Shaped 입력형 압전변압기의 설계)

  • Jung, Sung-Su;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.367-370
    • /
    • 2004
  • This paper present a new disk-type piezoelectric transformer. The input side of the transformer has a crescent-shaped electrode and the output side has a focused poling direction. The piezoelectric transformers operated in each transformer's resonance vibration mode. The electrodes and poling directions on commercially available piezoelectric ceramic disks were designed so that the planar or shear mode coupling factor $(k_p,\;k_{15})$ becomes effective rather than the transverse meed coupling factor $(k_{31})$. A single layer prototype transformer, 26[m] in diameter and 2.0[mm] thickness, was fabricated, such as step-up ratio, power transformation efficiency and temperature were measured.

  • PDF

Force Characteristic Analysis of Permanent Magnet Linear Coupling with Vertical Magnetized using an Analytical Magnetic Field Calculations (해석적 방법을 이용한 수직방향으로 자화된 영구자석 선형커플링의 힘 특성 해석)

  • Lee, Jae-Hyun;Choi, Jang-Young
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.742-743
    • /
    • 2015
  • Magnetic couplings are do not require any mechanical contact with the power transmitted to the secondary side according to the primary side. For this reason, well-suited for isolated systems such as vacuums or high pressure. So, this paper presents the force characteristic analysis of the permanent magnet (PM) linear coupling with vertical magnetized using an analytical magnetic field calculations. Based on the definition of governing equations and magnetic vector potential, we obtained the analytical solutions according to the boundary condition for each of the regions. Also, we derived from the force generated in the permanent magnet surface using the Maxwell stress tensor. The analytical results are proved the validity by comparing to the finite element method (FEM).

  • PDF

A Study on the Characteristics of Circular Piezoelectric Transformer which has Crescent-Shaped Input Electrode (Crescent-Shaped Input Type 원형압전변압기의 특성)

  • Jeong, Seong-Su;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.234-235
    • /
    • 2005
  • This paper present a new disk-type piezoelectric transformer. The input side of the transformer has a crescent-shaped electrode and the output side has a focused poling direction. The piezoelectric transformers operated in each transformer's resonance vibration mode. The electrodes and poling directions on commercially available piezoelectric ceramic disks were designed so that the planar or shear mode coupling factor ($k_p,\;k_{15}$) becomes effective rather than the transverse mode coupling factor ($k_{31}$).

  • PDF

Design and FEM Analysis of a Circular Piezoelectric Transformer with Crescent-Shaped Input Electrode (Crescent형 입력부를 가진 원형압전변압기의 설계 및 유한요소 해석)

  • Jeong, Seong-Su;Park, Tae-Gone
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1951-1953
    • /
    • 2005
  • This paper present a new disk-type piezoelectric transformer. The input side of the transformer has a crescent-shaped electrode and the output side has a focused poling direction. The piezoelectric transformers operated in each transformer's resonance vibration mode. The electrodes and poling directions on commercially available piezoelectric ceramic disks were designed so that the planar or shear mode coupling factor $(k_p,\;k_{15})$ becomes effective rather than the transverse mode coupling factor ($k_{31}$). A single layer prototype transformer, 26[mm] in diameter and $1.5{\sim}4.0[mm]$ thick, was fabricated, such as step-up ratio, power transformation efficiency and temperature were measured.

  • PDF

The Inductive Interference of Communication Line Near by Transmission Line (송전선로 주변 통신선의 유도장해 원인 분석)

  • Kang, Y.W.;Kwak, J.S.;Kweon, D.J.;Shim, E.B.;Bae, J.H.;Kim, J.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.400-402
    • /
    • 2003
  • The inductive interference can be happened on some of the communication line that is located near by paralleled transmission line. The causes of inductive interference are magnetic coupling, capacitive coupling and residual voltage at neutral point of transmission line. In this paper, after grounding the one side of communication line, we have measured the voltage to ground at the other side of it. And we also have measured the voltage to ground at the end of it without grounding. As a result, we proved that the cause of inductive interference is the difference of ground voltages.

  • PDF

A Study for improvement of Efficiency of Full-Bridge Converter using Non-Contact Method (무접점 풀브리지컨버터의 효율향상을 위한 연구)

  • Lim Sung-Hun;Joo Yeon-Hong;Lee Seong-Ryong;Han Byoung-Sung
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.90-93
    • /
    • 2001
  • This paper suggests the circuit topology to transfer AC power using a detachable transformer The circuit topology for AC output load through the magnetic coupling and its principle of operation are described. It can decrease the size of detachable transformer by employing the high-frequency magnetic coupling. It is shown in this paper that the efficiency of noncontact energy transfer system can be improved by applying both the full bridge converter with PFC function to the 1st side of its and the series resonance to the 2nd side to minimize the effect of the leakage inductance.

  • PDF

Synthesis, Photovoltaic Properties and Side-chain Effect of Copolymer Containing Phenothiazine and 2,1,3-Benzothiadiazole (Phenothiazine과 2,1,3-Benzothiadiazole을 포함한 Copolymer의 합성 및 Side-chain 치환에 따른 Photovoltaic 특성 연구)

  • Yun, Dae-Hee;Yoo, Han-Sol;Seong, Ki-Ho;Lim, Jeong-Ho;Park, Yong-Sung;Wo, Je-Wan
    • Applied Chemistry for Engineering
    • /
    • v.25 no.5
    • /
    • pp.487-496
    • /
    • 2014
  • In this study, three kinds of polymers based on phenothiazine-benzothiadiazole were synthesized by a Suzuki coupling reaction, and the various side-chains were substituted at the nitrogen of phenothiazine. The optical and electrochemical properties of synthesized polymers were analyzed. The results indicate that their absorption ranged from 300 to 700 nm, and also confirmed the ideal highest occupied molecular orbital (HOMO) energy level was about -5.4 eV with low band-gap energy. Photovoltaic devices were fabricated using a photoactive layer composed of a blended solution of the polymer and $PC_{71}BM$ in ortho-dichlorobenzene The device with P2HDPZ-bTP-OBT containing the branched side-chain and long chain showed the best performance; the maximum power conversion efficiency of this device was 2.4% (with $V_{OC}$ : 0.74 V, $J_{SC}$ : $6.9mA/cm^2$, FF : 48.0%).

Variable Optical Attenuator using Optical Coupling between a Side Polished Fiber and Refractive Index Matching Liquid (측면 연마된 광섬유와 굴절률 정합액사이의 광결합을 이용한 가변 광 감쇠기)

  • Kim, Kwang-Taek;Song, Jae-Won
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.9
    • /
    • pp.50-55
    • /
    • 1999
  • In this paper we proposed a variable optical attenuator using the side polished fiber coupled with a refractive index matching liquid. Small variation of refractive index of matching liquid can induce very large change of optical loss due to the coupling between the fiber mode and radiation mode. The thermo-optic effect of matching liquid was used to ontrol the optical attenuation. The side polished fiber block was fabricated using the silicon V gloove. Experimental results showed that $5^{\circ}C$ temperature variation was enough to adjust full range attenuation. The polarization dependent loss and insertion loss of the fabricated devices were 0.5dB and 0.2dB respectively.

  • PDF