• Title/Summary/Keyword: Side walls

Search Result 299, Processing Time 0.026 seconds

Fabrication of 3-D Structures by Inclined and Rear-side Exposures (선택적 경사 노광과 후면 노광에 의한 3차원 구조물의 제작)

  • 이준섭;신현준;문성욱;송석호;김태엽
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.1
    • /
    • pp.47-52
    • /
    • 2004
  • 3D microstructures with different side-wall angles and different scales are fabricated by both methods of inclined exposure and rear-side exposure at each of selected areas on a same substrate. Conventional methods of inclined exposure are used to make side-walls with a same inclined angle on one substrate and to get a scale error due to front-side exposure through thick photoresist layer, But, by using the proposed method, we are able to fabricate 3D microstructures on a same substrate with various side-wall angles and accurate dimensions as the original design. In the rear-side exposure, UV exposure light reflects from the chromium mask pattern after passing through the thick photoresist layer, resulting in fabrication of well-defined, inclined 3D structures inside the thick photoresist layer.

Effects of a Specularly Reflecting Wall in an Infinite Square Duct on Conductive-Radiative Heat Transfer (정사각형 계의 전도-복사열전달에서 정반사면의 영향)

  • Byeon, Gi-Hong;Han, Dong-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1451-1458
    • /
    • 2001
  • The effects of a specularly reflecting surface on the wall heat flux and medium temperature distribution are studied. The system is an infinite square duct enclosing an absorbing and emitting medium. The walls are opaque, and black or gray. The walls emit diffusely but reflect diffusely or speculary. Heat is transferred by the combined effect of conduction and radiation. The radiative heat transfer is analyzed using direct discrete-ordinates method. The parameters under study are conduction, to radiation parameter, optical depth, wall emissivity, and reflection characteristics. The specular reflection and diffuse reflection show sizeable differences when the conduction to radiation parameter is less than around 0.01. The differences appear only either on the side wall heat flux or on the medium temperature profiles for the range of this study. The differences on the side wall heat flux are observed for optical thickness less than around 0.1 However the differences on the medium temperate profiles are found for optical thickness greater than around 1. The difference increase with increasing reflectance. The specular reflection increases the well heat flux gradient along the side wall.

The Application of 1-Dimensional Diffusers in Classroom Acoustics (1차 단순 확산체를 적용한 교실음향설계)

  • Choi, Young-Ji
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.18 no.5
    • /
    • pp.3-11
    • /
    • 2011
  • In this study, the effect of treating 1-dimensional diffusers on the classroom acoustics was investigated to determine if the diffuser are beneficial for performing the preferred acoustical conditions for speech. A 1/10 scale model of a classroom was used to measure the acoustical parameters, T30, $C_{50}$, STI and SNR in that room. The room acoustical conditions were varied by treating diffusers either on the front or side walls of the classroom. When the diffusers were treated on the side walls around the student's areas, a shorter reverberation time at low frequencies was obtained and resulted in performing uniform reverberation times across the frequency bands. The $C_{50}$ values at mid- and high-frequencies were increased by treating the diffusers either on front or side wall surfaces. The highest STI and SNR values were obtained when the diffuser was treated on the front wall around the teacher's areas. It is found that diffusers are beneficial to increase the intelligibility of speech for the rear seats of the rooms.

  • PDF

Experimental study on the ground movement due to consecutive construction of retaining wall and underground space in cohesionless soil (사질토 지반에서 흙막이벽체-지하공간 연속 굴착에 따른 지반거동에 대한 실험적 연구)

  • Park, Jong-Deok;Yu, Jeong-Seon;Kim, Do-Youp;Lee, Seok-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.267-281
    • /
    • 2015
  • The ground movement and changes in earth pressure due to the consecutive construction of retaining wall and underground space were studied experimentally. A soil tank having 160 cm in length and 120 cm in height, was manufactured to simulate the vertical excavation like retaining wall by using 10 separated right side walls and underground space excavation like tunnel by using 5 separated bottom walls. The variation of earth pressure and surface settlement were measured according to the excavation stages. The results showed that the decrease of earth pressure due to the wall movement can cause the increase of earth pressure of the neighboring walls proving the arching effect. Experiments simulating continuous construction sequence also identified arching effect, however only 50% of earth pressure was restored on the 10th right side wall due to the movement of 1st bottom side wall unusually.

Effects of Cutting Speed and Feed Rate on Axial Shape in Side Walls Generated by Flat End-milling Process (평엔드밀링 공정에서 절삭속도 및 이송속도가 측벽의 축방향 형상에 미치는 영향)

  • Kim, Kang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.5
    • /
    • pp.391-399
    • /
    • 2017
  • This paper presents the effects of the cutting speed and feed rate on the axial shape of flat end-milled down cut side walls. Experiments were performed using the cutting speed, tool diameter, and feed per tooth as variables, and the thrust force and axial shape were measured as the experimental results. The results of this study confirmed that a smaller feed per tooth, which is proportional to the value obtained by dividing the feed rate by the cutting speed, results in a higher axial shape accuracy. In addition, the axial shape can be simplified to a form in which two straight lines having different slopes meet at a singular point. Therefore, it was concluded that the shape accuracy could easily be estimated during the operation and improved by adjusting the feed per tooth.

Effect of Wall Thickness on Thermal Behaviors of RC Walls Under Fire Conditions

  • Kang, Jiyeon;Yoon, Hyunah;Kim, Woosuk;Kodur, Venkatesh;Shin, Yeongsoo;Kim, Heesun
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.sup3
    • /
    • pp.19-31
    • /
    • 2016
  • The objective of this paper is to investigate the effect of thickness and moisture on temperature distributions of reinforced concrete walls under fire conditions. Toward this goal, the first three wall specimens having different thicknesses are heated for 2 h according to ISO standard heating curve and the temperature distribution through the wall thickness is measured. Since the thermal behavior of the tested walls is influenced by thickness, as well as moisture content, three additional walls are prepared and preheated to reduce moisture content and then tested under fire exposure. The experimental results clearly show the temperatures measured close to the fire exposed surface of the thickest wall with 250 mm thickness is the highest in the temperatures measured at the same location of the thinner wall with 150 mm thickness because of the moisture clog that is formed inside the wall with 250 mm of thickness. This prevents heat being transferred to the opposite side of the heated surface. This is also confirmed by the thermal behavior of the preheated walls, showing that the temperature is well distributed in the preheated walls as compared to that in non-preheated walls. Finite element models including moisture clog zone are generated to simulate fire tests with consideration of moisture clog effect. The temperature distributions of the models predicted from the transient heat analyses are compared with experimental results and show good agreements. In addition, parametric studies are performed with various moisture contents in order to investigate effect of moisture contents on the thermal behaviors of the concrete walls.

Distribution of Wind Force Coefficients on the Two-span Arched House (아치형 2연동하우스의 풍력계수 분포에 관한 연구)

  • 이석건;이현우
    • Journal of Bio-Environment Control
    • /
    • v.1 no.2
    • /
    • pp.142-147
    • /
    • 1992
  • The wind pressure distributions were analyzed to provide fundamental criteria for the structural design on the two-span arched house according to the wind directions through the wind tunnel experiment. In order to investigate the wind force distributions, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated using the experimental data. The results obtained are as follows : 1. The variation of the wind force with wind directions on the side walls was the greatest at the upwind edge of the walls. 2. The maximum negative wind force along the length of the roof appeared at the upwind edge at the wind direction of 60$^{\circ}$. 3. The maximum negative wind force along the width of the roof appeared at the width ratio and wind direction of 0$^{\circ}$ and 0.4 in the first house and 0.6 and 30$^{\circ}$ in the second house, respectively. 4. The mean negative wind force on the side walls of the first house at the wind direction of 0$^{\circ}$ was far greater than that of the second house, and the maximum negative wind force on the roof occurred at the wind direction of 30$^{\circ}$. 5. The maximum lift force appeared on the second house at the wind direction of 30$^{\circ}$, but the lift force on the first house was far greater than that on the second house at the wind direction of 0$^{\circ}$. 6. The parts to be considered for the local wind forces were the edges of the walls, and the edges of the x-direction and the width ratio, 0.4 of the y-direction in the roofs.

  • PDF

Distribution of Wind Force Coefficients on the Three-span Arched House (아치형 3연동하우스의 풍력계수 분포에 관한 연구)

  • 이현우;이석건
    • Journal of Bio-Environment Control
    • /
    • v.2 no.1
    • /
    • pp.46-52
    • /
    • 1993
  • The wind pressure distributions were analyzed through the wind tunnel experiment to provide fundamental criteria for the structural design on the three-span arched house according to the wind directions. In order to investigate the wind force distribution, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated from the experimental data. The results obtained are as follows : 1. The variation of the wind force with the wind directions on the side walls was the greatest at the upwind edge of the walls. The change of pressure from the positive to the negative on the side walls occurred at the wind direction of 30$^{\circ}$ in the first house and 60$^{\circ}$ in the third house. 2. The maximum negative wind force along the length of the roof appeared at the length ratio of 0-0.2, when the wind directions were 90$^{\circ}$ in the first house, 60$^{\circ}$ in the second house and 30$^{\circ}$ in the third house. 3. The maximum negative wind force along the width of the roof appeared at the width ratio and the wind direction of 0.4 and 0$^{\circ}$ in the first house, 0.4-0.6 and 30$^{\circ}$ in the second house and 0.6 and 30$^{\circ}$ in the third house, respectively. 4. The maximum mean positive and negative wind forces occurred at the wind direction of 60$^{\circ}$ and 30$^{\circ}$, respectively, on the side walls of the first house, and the maximum mean negative wind force on the roof occurred at the wind direction of 30$^{\circ}$ in third house. 5. The maximum drag and lift forces occurred at the wind direction of 30$^{\circ}$, and the maximum lift force appeared in the third house. 6. The parts to be considered for the local wind forces were the edges of the walls, the edges of the x-direction of the roofs, and the locations of the width ratio of 0.4 of the first and third house and the center of the width of the second house for the y-direction of the roofs.

  • PDF

An Experimental Study on Cement Film Thickness Between Casting Restorations and Preparation Walls. (주조물(鑄造物) 접착후(接着後) Cement층(層) 후경측정(厚徑測定)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Park, Ui-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.8 no.1
    • /
    • pp.25-29
    • /
    • 1968
  • The purposes of this study were to measure the film thickness of zinc phosphate cement between the casting restorations and preparation walls. In addition, the differences between finger press and non press techniques after the castings were seated completely on the preparation by an automatic mallet until the cement set were studied. The results were as follows : 1) In full cast crown, the cement film thickness on the side wall was thinner than that on the other walls. 2) In 3/4 crown and inlay, the cement thickness was thinner than that in cast crowns. 3) The cement of great W/P ratio showed thinner thickness than that of little W/P ratio. 4) The continuous finger press after the castings were seated completely on the preparations had few influence on the cement film thickness.

  • PDF

A Numerical Study of Natural Convection within a Trapezoidal Enclosure (부채형 공간내의 자연대류에 관한 수치해석적 연구)

  • Bae, T.Y.;Bai, D.S.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.1
    • /
    • pp.11-19
    • /
    • 1992
  • The natural convection heat transfer within a trapezoidal enclosure with parallel cylindrical top and bottom walls at different temperatures and two adiabatic side walls are studied. A finite-difference method has been used to solve the governing equations numerically. The range of parameters studied herein are Prandtl number 0.7, aspect ratio from 0.5 to 4.0, Rayleigh number from $10^3$ to $3{\times}10^4$, enclosure tilt angle from 22.5 to 157.5 degrees. Mean and local Nusselt numbers are presented for discussing heat transfer characteristics within the enclosure. The heat balances for the hot and cold walls are differed by less than 1% for converged solutions, so these results appear to be reasonable.

  • PDF