• Title/Summary/Keyword: Side walls

Search Result 302, Processing Time 0.025 seconds

Effect of Variation of Heated Bottom Wall Area on Natural Convection in Square Enclosure with Inner Circular Cylinder (원형 실린더가 존재하는 사각 밀폐계 바닥면의 고온 영역 변화가 자연대류 현상에 미치는 영향)

  • Jo, Hyun Woo;Yoon, Hyun Sik;Lee, Hyo Jeong;Kim, Minsung;Ha, Man Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.11
    • /
    • pp.991-998
    • /
    • 2013
  • A numerical study is carried out for natural convection in an enclosure with an inner hot cylinder at the center. The top wall is cold, the bottom and both side walls of the enclosure are adiabatic, and the cylinder is heated. The bottom wall is heated locally at the middle. The ratio (w) is defined by as the width of the bottom wall to that of the heated local area. The immersed boundary method (IBM) is used to model an inner circular cylinder based on the finite volume method (FVM). This study investigates the effect of w on natural convection in an enclosure with an inner heated cylinder for Rayleigh numbers of $10^6$. At $6Ra=10^6$, thermal and flow fields show time-dependent characteristics after their full development.

Palaeomagnetism of Tertiary Basins in Southern Korea: 2. Basaltic Rocks in the Central Part of Pohang Basin (남한 제3기 분지지역에 대한 고자기 연구 : 2. 포항분지 중부의 현무암질암)

  • Son, Moon;Kim, In-Soo
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.369-380
    • /
    • 1996
  • In order to determine the emplacement time and stratigraphic position of basaltic rocks in the central part of Pohang basin, palaeomagnetic investigations were conducted on 111 samples collected from 6 sites. Formation mean built from site-mean ChRM directions is $d=340.7^{\circ}$, $i=52.2^{\circ}$ (${\alpha}_{95}=6.0^{\circ}$, k=91) in the geographic coordinates. If "tilt" correction is applied regarding the plane perpendicular to the side walls of columnar joint as palaeohorizon, the formation mean becomes $d=328.7^{\circ}$, $i=43.8^{\circ}$ (${\alpha}_{95}=17.1^{\circ}$, k=13). It is to be noticed that the formation mean is deflected significantly (about $20{\sim}30^{\circ}$) counterclockwise from the Tertiary reference geomagnetic field of Eurasia, independent of "tilt" correction. This situation is very different from that of clockwise rotation of ChRM directions which has been ubiquitously observed in other Tertiary basins of south Korea, and indicates sinistral regional simple-shearing during the emplacement times of the basaltic rocks. Considering previous palaeomagnetic and AMS (anisotropy of magnetic susceptibility) data from other Tertiary regions of south Korea, the time of this sinistral shearing should be 15 Ma or directly thereafter, and this time point represents inversion from extensional to compressional tectonic regime. Magnetic foliation data obtained in this study indicate WNW-ESN compression during or directly after emplacement of the basaltic rocks, while it has known from regional tectonic study that the time of the WNW-ESN compression is about 15 Ma, when SW Honshu was rotated and the Korean strait was narrowed.

  • PDF

A Study on the Distribution of the Peak Wind Pressure for Rooftop Signboards (건물 옥상에 설치되는 옥상 간판의 피크풍압 분포에 대한 연구)

  • Nam, Byung-Hee;You, Jang-Youl;Lee, Nam-Hun;You, Ki-Pyo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.2
    • /
    • pp.79-86
    • /
    • 2018
  • Unlike other types of outdoor advertisements, rooftop signboards are installed on the roofs of buildings, rather than on their outer walls. This means that the area of a rooftop signboard is commonly larger than that of a general outdoor signboard. Moreover, as such signboards are greatly influenced by the wind, they can suffer a lot of damage from typhoons and strong winds every year. However, there is no wind load specification for rooftop signboards. In this study, wind pressure experiments were conducted to investigate the peak wind pressure on each side of rooftop signboards installed on the roofs of 5-15 story buildings in a city center. The minimum peak wind pressure coefficient was -3.0 at the bottom edges of the front and back of the rooftop signboards and -2.0 along the entire length of the sides. As the height of the rooftop signboard increased with the increasing height of the buildings, the peak value was found to be larger than the absolute peak value for the minimum peak wind pressure coefficient. The maximum and minimum peak wind pressure distributions of the rooftop outdoor signboards were influenced by the position of the signboard and the wind angle.

Studies on Eriophyes kuko KISHIDA and its Galls. IV. Studies on the Growing Mite Gall under Light and Electron Microscopes (구기자혹응애 (Eriophyes kuko KISHIDA) 및 그 혹(Gall)에 관한 연구. IV. 혹의 성장에 따르는 광현적(光顯的) 및 전현적(電顯的) 관찰)

  • Kim, Chang-Hyo;Sigenobu, Kawamatu;So, In-Yung
    • Applied Microscopy
    • /
    • v.2 no.1
    • /
    • pp.17-31
    • /
    • 1972
  • Light and electron microscopic studies were made to investigate the morphological changes in growing galls on the leaf of Lycium chinense MILL caused by Eriophyes kuko Kishda. The results are summarized as follows: 1. Light microscopy At the early stage of the invasion of E. kuko on the back side of the young leaf of L. chinense, the.epidermal cells become hypertrophic and develope a gall. As the gall grows, the cells of both palisade and spongy-layers become hypertrophic and these tissues are hard to be distinguished because of their irregular outgrowth. As the gall grows, the nuclei of the gall also become hypertrophic and larger than these of normal cells. 2. Electron microscopy Under electron microscopy the mitochondria, the golgi apparatus and the plastids of the advanced galls are degenerated and disintergrated and the cell walls become thicker than normal ones. The characteristic star bodies and the ring-form structures are found in the mature gall cells.

  • PDF

Effective stiffness in regular R/C frames subjected to seismic loads

  • Micelli, Francesco;Candido, Leandro;Leone, Marianovella;Aiello, Maria Antonietta
    • Earthquakes and Structures
    • /
    • v.9 no.3
    • /
    • pp.481-501
    • /
    • 2015
  • Current design codes and technical recommendations often provide rough indications on how to assess effective stiffness of Reinforced Concrete (R/C) frames subjected to seismic loads, which is a key factor when a linear analysis is performed. The Italian design code (NTC-2008), Eurocode 8 and ACI 318 do not take into account all the structural parameters affecting the effective stiffness and this may not be on the safe side when second-order $P-{\Delta}$ effects may occur. This paper presents a study on the factors influencing the effective stiffness of R/C beams, columns and walls under seismic forces. Five different approaches are adopted and analyzed in order to evaluate the effective stiffness of R/C members, in accordance with the scientific literature and the international design codes. Furthermore, the paper discusses the outcomes of a parametric analysis performed on an actual R/C building and analyses the main variables, namely reinforcement ratio, axial load ratio, concrete compressive strength, and type of shallow beams. The second-order effects are investigated and the resulting displacements related to the Damage Limit State (DLS) under seismic loads are discussed. Although the effective stiffness increases with steel ratio, the analytical results show that the limit of 50% of the initial stiffness turns out to be the upper bound for small values of axial-load ratio, rather than a lower bound as indicated by both Italian NTC-2008 and EC8. As a result, in some cases the current Italian and European provisions tend to underestimate second-order $P-{\Delta}$ effects, when the DLS is investigated under seismic loading.

Development of a retrofit anchor system for remodeling of building exteriors

  • Yeun, Kyu Won;Hong, Ki Nam;Kim, Jong
    • Structural Engineering and Mechanics
    • /
    • v.44 no.6
    • /
    • pp.839-856
    • /
    • 2012
  • To enable remodeling of the exterior of buildings more convenient, such finishing materials as curtain walls, metal panels, concrete panels or dry stones need to be easily detached. In this respect, this study proposed a new design of the slab for the purposes. In the new design, the sides of the slab were properly modified, and the capabilities of anchors fixed in the modified slab were experimentally tested. In details, a number of concrete specimens with different sizes and compressive strengths were prepared, and the effect of anchors with different diameters and embedment depths applied in the concrete specimens were tested. The test results of the maximum capacities of the anchors were compared with the number of current design codes and the stress distribution was identified. This study found that the embedment depth specified in the current design code (ACI318-08) should be revised to be more than 1.5 times the edge distance. However, with the steel sheet reinforcement, the experiment acquired higher tensile strength than the design code proposed. In addition, for two types of specimens in the tensile strength experiment, the current design code (ACI 318-08) is overestimated for the anchor depth of 75 mm. This study demonstrated that the ideal breakout failure was attainable for the side slot details of a slab with more than 180 mm of a slab thickness and less than 75 mm of an anchor embedment depth. It is expected that these details of the modified slab can be specified in the upgraded construction design codes.

Design and Evaluations of Underwater Hydrophone with Self Noise Suppressing Structures -Part Ⅰ. Noise Transfer Characteristics & Effects of Structure Modifications - (저 잡음 수중 청음기의 설계 방안 연구 -Ⅰ. 잡음 전달 특성 및 구조 변경 영향 -)

  • Im, Jong-In;Roh, Young-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.10-15
    • /
    • 1997
  • The hydrophones is mounted in many applications on a vibrating surface and functions as an underwater acoustic signal receiver without sensing the vibrations from the mounting surface. However, their performance is usually degraded by the interference of exterior noises such as acoustic cavitation in water stream, host structural vibration in the hull, and propeller motions. This paper describes the design and evaluation of a self noise suppressing hydrophones which shows very poor sensitivity to the external noises, first, effects of the external noise on the its receiver performance is simulated with finite element method(FEM). Second, the geometrical variations are implemented on the original structure that include additional air pockets and acoustic walls which work as acoustic shied or scatter of the noises. The results show that the effect of the external noise is the most significant when it is applied near to the bottom of the side wall of the hydrophones. The transverse noise induced by the outside water flow is isolated most effectively when a thin compliant (damping) layer combined with two air pockets is inserted to the circumference of the nose. Noise level is reduced about fifty nine percent of that of the original structure.

  • PDF

Plan Composition Expressed in the Architecture of Art Gallery Designed by Louis I. Kahn - Focus on the Yale University Art Gallery Extension - (Louis I. Kahn의 미술관 건축에 나타난 평면구성에 관한 연구 - Yale University Art Gallery Extension을 중심으로 -)

  • Kim, Hong-Bae
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.3
    • /
    • pp.128-135
    • /
    • 2012
  • The purpose of this study is to investigate and analyze the compositional elements of plan of art museums by selecting architectural works, which have strong symbolic meaning when evaluating value, from architectural works by Louis Kahn. First, the centrality of artworks, which are being displayed at the Yale Art Gallery, is complex. It includes three patterns of Void (spatial) Centrality+Symbolic Centrality+Functional Centrality among the five patterns suggested in this study. Second, the ratio system of interior space, which is expressed in the extension of the Yale Art Gallery, can be classified into the floor and walls. The floor used the square 1:1 ratio system. The ceiling used the grid patterns of equilateral triangles (regular tetrahedrons). It was applying a geometric ratio system when creating forms by using one side as a beam and the other sides as decorations of the ceiling. Third, the contours of interior space, which were expressed in Kahn's works, used the method of forming separate space according to the contouring rule (structural unit) defined by columns, and they were used in constructing the entire space through the integration of separate spaces. Fourth, according to the characteristics that were expressed by artworks displayed within the Yale Art Gallery Extension, the concept of accessibility was not as clear as that of residential buildings, because an approach of respecting existing architecture and context was used, rather than the starting point of interior space, or differentiated circulation, which has the function of a determined position.

  • PDF

ADPI Characteristics of Line Diffuser in a Room with Perimetric Heating Load (측벽 부하가 존재하는 공간에 설치된 라인 디퓨져의 ADPI 특성에 관한 연구)

  • Cho Young-Jin;Kang Seok-Youn;Moon Jong -Sun;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1204-1211
    • /
    • 2004
  • It is difficult to apply a conventional selection guide for diffusers when the diffuser is installed in a perimeter zone, because the air diffusion performance index (ADPI) vs. throw/length (T/L) ratio curve listed in conventional guide does not consider the perimetric heating load through the walls. The objective of this study is to evaluate the effect of the perimetric heating load on the ADPI and propose a selection guide for a proper line diffuser when perimetric heating load exists. The velocity and temperature distributions and the ADPI values are obtained numerically with various heat load ratios and air flow rates. The velocity and temperature distributions and the ADPI values are analyzed by CFD in case of various heat load ratios and air flow rates. Also, ADPI was calculated by those results. The ADPI values by numerical results are compared with an existing experimental data to verify the method for the evaluation of ADPI proposed in a present study. In case of a line diffuser installed at the high side wall, the ADPI decreases according to the increases of the flow rate on every heat load ratio of the present study except 0.75. The ADPI vs. T/L ratio curves have been proposed for the heat load ratios of 0.25, 0.5, 0.75 to guarantee the comport thermal environment when diffusers are installed in perimeter zone.

Investigation of the behavior of a tunnel subjected to strike-slip fault rupture with experimental approach

  • Zhen Cui;Tianqiang Wang;Qian Sheng;Guangxin Zhou
    • Geomechanics and Engineering
    • /
    • v.33 no.5
    • /
    • pp.477-486
    • /
    • 2023
  • In the studies on fault dislocation of tunnel, existing literatures are mainly focused on the problems caused by normal and reverse faults, but few on strike-slip faults. The paper aims to research the deformation and failure mechanism of a tunnel under strike-slip faulting based on a model test and test-calibrated numerical simulation. A potential faulting hazard condition is considered for a real water tunnel in central Yunnan, China. Based on the faulting hazard to tunnel, laboratory model tests were conducted with a test apparatus that specially designed for strike-slip faults. Then, to verify the results obtained from the model test, a finite element model was built. By comparison, the numerical results agree with tested ones well. The results indicated that most of the shear deformation and damage would appear within fault fracture zone. The tunnel exhibited a horizontal S-shaped deformation profile under strike-slip faulting. The side walls of the tunnel mainly experience tension and compression strain state, while the roof and floor of the tunnel would be in a shear state. Circular cracks on tunnel near fault fracture zone were more significant owing to shear effects of strike-slip faulting, while the longitudinal cracks occurred at the hanging wall.