• 제목/요약/키워드: Side resistance

검색결과 736건 처리시간 0.032초

Nb_{3}$Sn 초전도 CICC의 sub-cable to sub-cable 접합 및 접합저항 측정 (Measurement of electrical resistance at the Nb_{3}$Sn CICC joint fabricated by sub-cable to sub-cable joining)

  • 이호진;홍계원;김기백;권선칠;김기만
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.89-92
    • /
    • 1999
  • A small scale joint sample of Nb3Sn CICC was fabricated by sub-cable to sub-cable joining. This joint was produced by parallel insertion of one end of each sub-cable into the sub-cable space of the other side of cable, which can decrease the equivalent electrical resistance at the joint is expected to have average properties, dc resistance and ac losses, in view of the shapes of ITER type joint and strand to strand joint. The 3.8nOhm of dc resistance was measured in the range of 10-200A transport current. The normalized resistivity of the joint was about 6.7 $\mu}$Ohm-$^mm{2}$. Considering the normalized resistivity, the full scale joint prepared by sub-cable to sub-cable joining may have similar joint dc resistance with other conventional full scale joints with a shorter joining length.

  • PDF

30피트급 고속 알루미늄 레저보트 선형개발과 저항성능에 관한 연구 (Study on Hull Form Development and Resistance Performance of High Speed Aluminum Leisure Boat)

  • 정우철;김도정;최홍식
    • 한국해양공학회지
    • /
    • 제26권6호
    • /
    • pp.14-18
    • /
    • 2012
  • A 30ft class aluminum leisure boat is newly developed and the resistance performances are investigated by a model test at a high-speed circulating water channel. The effect of a fin attached to the side of the hull is studied at two different displacements. Wave patterns are observed to make clear the relationship between the resistance performance and wave characteristics. It can be found that a chine position at the draft line can have a strong effect on the resistance performance around a certain velocity range.

Greenhouse Method for Assessing Spot Blotch Resistance in Barley

  • Arabi, Mohammad Imad Eddin;Jawhar, Mohammad
    • The Plant Pathology Journal
    • /
    • 제26권4호
    • /
    • pp.421-423
    • /
    • 2010
  • New sources of barley (Hordeum vulgare L.) resistant to spot blotch, caused by Cochliobolus sativus, are needed to provide effective resistance because of the rapid change pathotype patterns of C. sativus in fields. The purposes of our study were to develop a method to screen barley for resistance to spot blotch disease and then use this methodology to screen barley genotypes for resistance to the major virulent pathotype Pt4 in barley populations in Syria. A transparent tape method, in which a conidial suspension of C. sativus was dropped onto transparent tape and placed, treated-side down, on the second leaf surface of barley plants. Disease symptoms of fungus were easily detected on the leaves covered by the transparent tape after 48h of inoculation. The transparent tape method was repeatable and the disease scores obtained were correlated (r = 0.91, P = 0.001) with those obtained by the seedling assay. This method may be beneficial in various plant pathology breeding programs.

Numerical simulation of set-up around shaft of XCC pile in clay

  • Liu, Fei;Yi, Jiangtao;Cheng, Po;Yao, Kai
    • Geomechanics and Engineering
    • /
    • 제21권5호
    • /
    • pp.489-501
    • /
    • 2020
  • This paper conducts a complicated coupled effective stress analysis of X-section-in-place concrete (XCC) pile installation and consolidation processes using the dual-stage Eulerian-Lagrangian (DSEL) technique incorporating the modified Cam-clay model. The numerical model is verified by centrifuge data and field test results. The main objective of this study is to investigate the shape effect of XCC pile cross-section on radial total stress, excess pore pressure and time-dependent strength. The discrepancies of the penetration mechanism and set-up effects on pile shaft resistance between the XCC pile and circular pile are discussed. Particular attention is placed on the time-dependent strength around the XCC pile shaft. The results show that soil strength improved more significantly close to the flat side compared with the concave side. Additionally, the computed ultimate shaft resistance of XCC pile incorporating set-up effects is 1.45 times that of the circular pile. The present findings are likely helpful in facilitating the incorporation of set-up effects into XCC pile design practices.

An Empirical Study about the Segmented Cell in Anode Side of PEMFC

  • 김재호;손영준;김민진;박구곤;임성대
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.357-360
    • /
    • 2009
  • The present study focused on the segmented cell which has the similar performance to unaltered (not segmented) cell in real operating condition. Many literatures have been made the segmented cell to observe the behavior of local current density distribution in the single cell. However, it has been lack of scheme to segment the cell in that the detailed interpretation of segmenting in analytic point of view was insufficient. Hence, the basic idea of segmenting was introduced to determine the component to be segmented in anode side of unit cell. The electrical contact/bulk resistance was measured by using four wire/probe method through each part of cell components including MEA, GDL, Bipolar Plate and Current Collector. Electron transport mechanism was predicted by comparing resistance values which were obtained from the experiment. As a result, this offered a great benefit to segment the cell efficiently. With this method further experiments would be conducted in research areas which require current density distribution at the same operating condition as unaltered cell.

  • PDF

평행유동에서 공랭식 열전모듈 냉각시스템의 성능에 관한 연구 (A Study on Performance of Thermoelectric Air-Cooling System in Parallel Flow)

  • 강상우;신재훈;한훈식;김서영
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.421-429
    • /
    • 2011
  • Experimental and theoretical studies on cooling performance of two-channel thermoelectric air-cooling system in parallel flow are conducted. The effects of operating temperature to physical properties of thermoelectric module (TEM) are experimentally examined and used in the analysis of an air-cooling system considering thermal network and energy balance. The theoretical predicted temperature variation and cooling capacity are in good agreement with measured data, thereby validating analytic model. The heat absorbed rate increases with increasing the voltage input and decreasing thermal resistance of the system. The power consumption of TEM is linearly proportional to mean temperature differences due to variations of the physical properties on operation temperature of TEM. Furthermore thermal resistance of hot side has greater effects on cooling performance than that of cold side.

암반에 근입된 말뚝의 선단 거동 특성에 관한 연구 (Study on the Behavior of Toe of Drilled Shaft on the Rock Mass)

  • 박완서;전석원;한용희;최세근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 춘계 학술발표회 초청강연 및 논문집
    • /
    • pp.842-847
    • /
    • 2008
  • Despite of the increasing number of the application of the drilled shaft pile in construction site, most of the study of pile capacity has been centered side shear resistance. But it is common that the drilled shaft is socketed on the rock so as to use the bearing resistance, so prediction of the toe's movement and characteristic of the bearing capacity is important as the side shear resistance. Therefore the model tests were performed in order to study the characteristic of bearing capacity on rock mass. The material of the test blocks were the mortar which was mixed with sand, cement and water, and test block size was $240{\times}240{\times}240mm$. Load was pressed by the 45mm of diameter of miniaturized pile and plate jack and steal plate were used to the confined stress for representing the underground condition. The relation of load-displacement was measured in many different conditions of rock mass such as direction of discontinuities, spacing and strength, and q-w curves of the toe of the pile were verified in each condition.

  • PDF

공진 코일의 크기와 부하 저항이 자계 공명 무선 전력 전송 장치의 전달 효율에 주는 영향에 관한 연구 (A Study on the Effect of Resonant Coil Size and Load Resistance on the Transmission Efficiency of Magnetic Resonance Wireless Power Transfer System)

  • 박정흠
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.45-51
    • /
    • 2012
  • In this paper, the wireless power transfer system using the magnetic resonance was designed and the effect of resonant coil radius and load resistance to this system was analyzed by the circuit analysis method. As a result, the calculated transmitted-power is similar to measured one, and the coil size has a small effect to the coupling coefficients in the resonant frequency band. In addition, the fact that the calculated transmitted-power according to the source frequency is similar to measured one confirms that the circuit analysis methode in this paper is valid. The input side transmission efficiency ${\eta}_i$ including only the loss in the power transfer circuit is almost 90[%] with the large coil in the 10[cm] transfer distance, and 65[%] with the small coil in 1[cm]. The source side transmission efficiency ${\eta}_s$ is 30~40[%] at both coil when load resistance below 4.7[${\Omega}$] has been connected. Considering that the maximum ${\eta}_s$ is 50[%], this is valid in the practical applications.

고속열차 대차 측면 페어링 적용을 통한 공기저항 저감 연구 (A STUDY ON THE AERODYNAMIC DRAG REDUCTION OF HIGH-SPEED TRAIN USING BOGIE SIDE FAIRING)

  • 문지수;김석원;권혁빈
    • 한국전산유체공학회지
    • /
    • 제19권1호
    • /
    • pp.41-46
    • /
    • 2014
  • The aerodynamic drag of high-speed train has been calculated and the effect of bogie side fairing on the aerodynamic drag has been investigated. Computational Fluid Dynamics (CFD) simulation based on steady-state 3 dimensional Navier-Stokes equation has been conducted employing FLUENT 12 and the aerodynamic model of HEMU-430x, the Korean next generation high-speed train under development has been built using GAMBIT 2.4.6. Three types of bogie side fairing configuration, the proto-type without fairing, half-covered fairing to avoid the interference with the bogie frame and full-covered fairing have been adopted to the train model to compare the drag reduction effects of the bogie side fairing configurations and the numerical results yields that the bogie side fairing can reduce the aerodynamic drag of the 6-car trainset up to 7.8%. The aerodynamic drag coefficient of each vehicle as well as the flow structures around the bogie system have also been examined to analyze the reason and mechanism of the drag reduction by bogie side fairing.