• 제목/요약/키워드: Side flushing devices

검색결과 4건 처리시간 0.015초

방전가공시 측면 플러싱 장치를 활용한 가공성 향상 (Improvements of Electro Discharge Machining Process using Side Flushing Devices)

  • 맹희영;박근;신승환
    • 한국공작기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.23-31
    • /
    • 2006
  • The present works concerns a side flushing device for the improvement of the conventional Electric-Discharge Machining(EDM) process. In the EDM process, chips are usually generated as the workpiece is removed, and deposited between the electrode and the workpiece. This sediment degrades the surface finish of the machined product as well as the processing efficiency. In the present study, a flushing device with additional side injection equipments is proposed in order to remove the deposited chips effectively. Through numerical simulations, the validity of the proposed device is verified, and the influence of process parameters is investigated. Experiments have been also carried out in the die sinking EDM process. It was observed that the process efficiency and the surface finish are improved by virtue of the proposed flushing device.

방전가공시 측면 플래싱 장치를 활용한 가공성 향상 (Improvements of Electro Discharge Machining Process using Side flushing Devices)

  • 신승환;박근;맹희영
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 추계학술대회
    • /
    • pp.334-343
    • /
    • 2003
  • The discharge gap clearly is to order and to promote the improvement of processing feature of die-sinking electro discharge machining(EDM). If creation carbon, which generated by Pyrolysis of EDM oil and processing pace power which is generated in between an electrode and a workpiece, are overproduced, they will lower the processing speed and roughness of the surface. Therefore, it is gone through an experiment and the flow analysis of EDM oil in order to improve the treatment of processing chips, which is an important problem by contriving a new flushing method. The condition of an electric discharge is not considered to be a progressing of processing. It is assumed that the flow of processing fluid is equal to the flow of processing chip, which is remaining in the discharge gap, and thus, analyzing then comparing with the data of the experiment and investigate its correlation.

  • PDF

측면 플래싱 장치를 이용한 형조 방전특성의 향상 (Improvements of Electro Discharge Machining characteristics using Side Flushing Devices)

  • 맹희영;박근;김성동
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.272-277
    • /
    • 2005
  • The discharge gap clearly is to order and to promote the improvement of processing feature of die-sinking electro discharge machining(EDM). If creation carbon, which generated by pyrolysis of EDM oil and processing pace power which is generated in between an electrode and a workpiece, are overproduced, they will lower the processing speed and roughness of the surface. Therefore, it is gone through the .flow analysis of EDM oil in order to improve the treatment of processing chips, which is an important problem by contriving a new flushing method. The condition of an electric discharge is not considered to be a progressing of processing. It is assumed that the flow of processing fluid is equal to the flow of processing chip, which is remaining in the discharge gap, and analyzing its correlation.

  • PDF

정맥으로 투여하는 발포성 항암제의 합병증 (Survey on the Side Effects of the Vesicant Chemotherapy)

  • 최은숙;김금순;주명순;김복자
    • 기본간호학회지
    • /
    • 제7권3호
    • /
    • pp.415-428
    • /
    • 2000
  • The purpose of this study was to identify side effects of the vesicant chemotherapy. The study was designed to be a descriptive survey. The subjects of this study were 88 patients with various types of cancer, primary lung cancer(25.0%), advanced gastric cancer(25.0%), breast cancer(20.5%), etc. The mean age was 44.8 years old(range: 16-68). The questionnaire was completed by nurses of the outpatient unit and chemotherapy ward, and intravenous nurse specialist. The results of the study were as follows: 1) Chemotherapy was administered with a 23G scalp needle and 24G insyte. Injection site was dorsum of hands(64.7%), cephalic vein(19.3%). Successful rate for the first attempt was 88.6%. The first & second cycle chemotherapy was 29.5% each.. Mainly used drugs were Navelbine(34.1%), Adriamycin(20.5%). 2) Venous Problems after chemotherapy were pain(13.6%) incurred by venous, mainly due to the administration of Navelbine; redness at the inravenous site(12.5%) and itching sense 2.3% Non-venous problems were nausea (18.2%), dullness(14.8%), vomiting(8.0%), facial flushing(6.8%), anxiety(5.7%). Subjective discomforts after chemotherapy were generalized arm pain at the injection side(14.8%), dizziness(6.8%), weakness(5.7%) and general bodyache(5.7%). Systemic anaphylactic reaction and extravasation did not occur. 3) Non-venous problem after chemotherapy were nausea, vomiting & anorexia. Frequency of chemotherapy related to side effects were itching, facial flushing, and nausea(p< .05). Day of chemotherapy related to side effects were nausea & vomiting(p< .05). Site of chemotherapy related to side effects were redness(p< .05). Frequency of venipuncture related to side effects were redness(p< .05). Conclusively, cancer chemotherapy patients have had some venous problem. They need appropriate venous access devices for chemotherapy. And other non-venous problem will be managed appropriately. Further research was required to identify the rate of venous complication or side effects of vesicant chemotherapy.

  • PDF