• 제목/요약/키워드: Side Friction

검색결과 296건 처리시간 0.02초

남해읍성의 공간구성과 축조기법에 관한 연구 (A Study on Techniques of the construction and Space Structure of Nam-hea city walls)

  • 권순강;이호열
    • 건축역사연구
    • /
    • 제18권5호
    • /
    • pp.59-80
    • /
    • 2009
  • The purpose of this study is to investigate the history, space structures, blueprint, and techniques of the construction of Nam-hea city walls. Nam-hea city walls were relocated in 1439 from Whagumhun-Sansung(火金峴山城) to the present site, nearby Nam-hea Um.(南海邑) The city walls were rebuilt after they were demolished during Japanese invasion on Korea in 1592 and their reconstruction was also done in 1757. At present, the city walls only partially remained due to the urbanization of the areas around them. A plane form of the City wall is a square, and the circumference os approximately 1.3km. According to the literature, the circumference of the castle walls is 2,876尺, the height is 13尺, and the width is 13尺 4寸. Hang-Kyo(鄕校). SaGikDan(社稷壇), YoeDan(厲壇), SunSo(船所) which is a harbor, as well as government and public offices such as Kaek-Sa(客舍) and Dong-Hun(東軒) existed inside the castle walls. Inside the castle walls were one well, five springs, one ditch, and one pond, and in the castle walls, four castle gates, three curved castle walls, and 590 battlements existed. The main government offices inside castle walls were composed of Kaek-Sa, Dong-Hun, and Han-Chung(鄕廳) their arrangements were as follows. Kaek-Sa was situated toward North. Dong-Hun was situated in the center of the west castle walls. The main roads were constructed to connect the North and South castle gate, and subsidiary roads were constructed to connect the East and West castle gate. The measurement used in the blueprint for castle wall was Pobaek-scale(布帛尺:1尺=46.66cm), and one side of it was 700尺. South and North gate were constructed in the center of South and North castle wall, and curved castle walls was situated there. One bastion was in the west of curved castle walls and two bastions were in the east of curved castle walls. The east gate was located in the five eighths of in the east castle wall. Two bastions were situated in the north, on bastion in the south, one bastion in the south, and four bastions in the west castle wall. The castle walls were constructed in the following order: construction of castle field, construction of castle foundation, construction of castle wall, and cover the castle foundation. The techniques used in the construction of the castle walls include timber pile(friction pile), replacement method by excavation.

  • PDF

GEOTECHNICAL DESIGNS OF THE SHIP IMPACT PROTECTION SYSTEM FOR INCHEON BRIDGE

  • Choi, Sung-Min;Oh, Seung-Tak;Park, Sang-Il;Kim, Sung-Hwan
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회 3차
    • /
    • pp.72-77
    • /
    • 2010
  • The Incheon Bridge, which was opened to the traffic in October 2009, is an 18.4 km long sea-crossing bridge connecting the Incheon International Airport with the expressway networks around the Seoul metropolitan area by way of Songdo District of Incheon City. This bridge is an integration of several special featured bridges and the major part of the bridge consists of cable-stayed spans. This marine cable-stayed bridge has a main span of 800 m wide to cross the vessel navigation channel in and out of the Incheon Port. In waterways where ship collision is anticipated, bridges shall be designed to resist ship impact forces, and/or, adequately protected by ship impact protection (SIP) systems. For the Incheon Bridge, large diameter circular dolphins as SIP were made at 44 locations of the both side of the main span around the piers of the cable-stayed bridge span. This world's largest dolphin-type SIP system protects the bridge against the collision with 100,000 DWT tanker navigating the channel with speed of 10 knots. Diameter of the dolphin is up to 25 m. Vessel collision risk was assessed by probability based analysis with AASHTO Method-II. The annual frequency of bridge collapse through the risk analysis for 71,370 cases of the impact scenario was less than $0.5{\times}10^{-4}$ and satisfies design requirements. The dolphin is the circular sheet pile structure filled with crushed rock and closed at the top with a robust concrete cap. The structural design was performed with numerical analyses of which constitutional model was verified by the physical model experiment using the geo-centrifugal testing equipment. 3D non-linear finite element models were used to analyze the structural response and energy-dissipating capability of dolphins which were deeply embedded in the seabed. The dolphin structure secures external stability and internal stability for ordinary loads such as wave and current pressure. Considering failure mechanism, stability assessment was performed for the strength limit state and service limit state of the dolphins. The friction angle of the crushed stone as a filling material was reduced to $38^{\circ}$ considering the possibility of contracting behavior as the impact.

  • PDF

조력발전용 수문 형상에 따른 통수성능에 관한 실험적 연구 - I. 수리모형실험 (Experimental Investigation of Water Discharge Capability According to Shape of Sluice for Tidal Power Generation - I. Physical Experiment)

  • 이달수;오상호;이진학;박우선;조휴상;김덕구
    • 한국해안·해양공학회논문집
    • /
    • 제20권1호
    • /
    • pp.73-80
    • /
    • 2008
  • 이 연구에서는 조력발전소 건설의 경제성에 큰 영향을 미치는 수문(sluice)형상의 설계기술을 향상시키기 위해서 개수로 시스템에서 수리모형실험을 수행하였다. 수문 형상을 결정짓는 주요한 설계 파라미터의 변화가 수문의 통수성능에 미치는 영향이 예측 가능하게 되기 위해서는 기존의 조력발전소 타당성조사 및 설계사업 등에서의 수리모형실험 방법과 차별화 되는 정밀한 실험을 수행해야 할 필요성이 있었다. 이를 위해서 유량공급시설 및 정류수조 내에 다양한 정류장치를 그 형상 및 배치 방법을 다르게 설치하여 관측수로 내 흐름이 최대한 안정화되도록 실험시설을 구성하였다. 그리고 유량 및 수위 계측 과정에서 개입되는 계측 오차를 최소화하기 위한 실험이 이루어질 수 있도록 계측장비의 종류 및 수위 계측위치를 결정하였다. 또한, 개수로 내 흐름에서 불가피하게 발생하는 바닥 및 양측면 마찰에 의한 수두 손실효과를 고려하는 수두차 평가 방법도 제시하였다.

동상시험장비의 실험적 검증 및 시료크기의 영향에 관한 연구 (Experimental Assessment and Specimen Height Effect in Frost Heave Testing Apparatus)

  • 진현우;유병현;이장근
    • 한국지반환경공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.67-74
    • /
    • 2019
  • 동상은 동토지역에서 발생하는 대표적인 공학적 특성이다. 계절동토(seasonal frost area)에 해당하는 우리나라는 동결융해에 의한 구조적 피해가 발생하고 동상에 관한 연구의 필요성이 증대되고 있는 실정이다. 본 논문에서는 새롭게 개발한 투명 온도제어형 셀을 활용하여 동상에 관한 연구를 수행하였다. 동상에 민감한 흙을 인공적으로 조성하여 동상민감성 판정에 있어 중요한 인자 중 하나인 물 주입속도(water intake rate)에 관한 분석을 실시하였다. 간극수 동결에 의한 부피팽창(heave by pore water)이 수렴하는 시점 이후에 동상속도(frost heave rate)와 물 주입속도는 거의 유사하게 나타났다. 그러나 물 주입속도를 측정하기 위해 상부 페더스탈에 설치한 O-ring은 몰드 내벽과의 마찰을 발생시켜 동상발생을 저하시켰다. 따라서 물 주입속도를 활용한 동상민감성 판정 기준은 신뢰하기 힘들다고 판단되었으며, 유사한 거동을 보이는 동상속도를 활용하는 것이 적절하다는 결론을 내렸다. 또한, 동상민감성 흙을 활용해 시료크기가 동상에 미치는 영향을 파악하고자 하였다. 시료크기가 다른 2가지 경우에 대해 동상시험을 수행하였으며 상재하중, 온도구배, 그리고 건조단위중량을 동일하게 설정하였다. 실험결과를 토대로 시료크기는 동상에 영향을 미치지 않는다는 것을 발견하였다.

타입강관말뚝의 토질별 하중전이곡선 도출에 관한 연구 (A Study on the Development of Load Transfer Curves of the Driven Steel Pipe Piles by Soil)

  • 임종석;최용규;심종선;박종희
    • 한국지반공학회논문집
    • /
    • 제25권9호
    • /
    • pp.29-43
    • /
    • 2009
  • 전산기술의 발달과 더불어 좀 더 복잡하고 반복적인 계산을 쉽게 수행할 수 있게 됨으로써 하중전이곡선을 이용한 하중전이해석법이 널리 이루어지고 있다. 현재 국내에서도 하중전이해석법을 많이 사용하고 있다. 그러나 이러한 하중전이해석법에서 사용되는 곡선들은 대부분 외국에서 개발된 곡선들로서 국내지반에서의 적용성 여부는 확실치 않다. 본 연구에서는 타입강관말뚝의 하중전이곡선을 도출하기 위하여 국내 9곳의 현장재하시험 데이터를 수집하였다. 이들을 분석하여 사질토와 점성토에 대하여 각각 $f/f_{max}$-w/D 곡선의 평균선을 구하였으며 각 곡선을 쌍곡선함수로 나타내었다. 그리고 이 곡선의 적용성을 알아보기 위하여 이 곡선을 이용한 결과와 말뚝해석 프로그램인 TZPILE 2.0을 이용한 결과를 국내 3현장의 재하시험결과와 비교분석하였다. 그 결과 일반적으로 본 연구의 결과를 적용하여 얻은 하중-침하량 관계가 기존의 TZPILE 2.0으로 얻은 관계보다 비교적 실측값에 가까운 경향을 보였으며 보수적으로 나타났다.

정신응급상황에서 119구급대원 대응사례와 법적쟁점 (Cases and Legal Issues For 119paramedics in Mental Emergency Situations)

  • 홍영표
    • 의료법학
    • /
    • 제25권1호
    • /
    • pp.87-115
    • /
    • 2024
  • 우리나라는 급격한 발전과 더불어 많은 성장을 이루는 과정에서 스트레스에 노출이 정신적 고통을 수반하게 되었고 다양한 사회문제로 나타나며, 응급입원의 빈도가 높아지고 있다. 정신질환자의 경우 '비자의 입원'이 문제가 되며, 경찰, 119구급대원이 정신질환자의 신체억제를 시도하며, 많은 문제점이 노출되고 있다. 이는 정신건강복지법 상 응급입원의 조항의 구성요건이 현실을 반영하지 못해 하나의 정신질환자를 두고 각 기관이 다른 입장을 내며, 응급입원이 원활하게 진행되지 않거나, 관계기관의 마찰로 이어지며 정신질환자의 안전이나, 타인의 안전이 확보되지 못하는 경우가 발생하고 있다. 응급입원은 주체가 '정신질환자로 추정되는 사람으로 자신의 건강 또는 안전이나 다른 사람에게 해를 끼칠 위험이 큰 사람을 발견한 사람'으로 정하고 있으며, 그 상황이 매우 급박하여 스스로 입원을 결정하는 입원절차를 거칠 시간적 여유가 없는 경우 의사와 경찰관의 동의를 얻어 응급입원을 의뢰할 수 있다고 규정하고, 이 경우 119구급대원이 정신의료기관까지의 호송하도록 하고 있다. 이러한 응급입원의 조항은 정신의료기관까지 이송하는 과정에 많은 문제를 내포하고 있다. 실무를 담당하는 경찰관이나 119구급대원이 응급입원과정 중 '물리력'을 사용하게 되면, 필연적으로 부작용이 발생하게 되는데, 업무상과실이 문제가 될 수 있으며, 구체적으로는 물리력을 행사할 때 법령에 근거하고 비례원칙에 따른 필요최소한도의 신체억제가 필요하게 되는데, 법령상 119구급대원이나 경찰관의 주의의무의 부재가 결국 다른 법령을 적용하여 해결하게 된다는 것이다. 이에 정신건강복지법 상 응급입원 조항의 주체를 경찰, 소방기관의 장점을 살려 주체를 변경하고, 정신보건법의 시행규칙으로 신체보호대 사용을 정의하고, 규정함으로써 119구급대원과 경찰관의 주의의무를 설정하고 정신질환자가 안전하게 치료받을 수 있도록 이송에 대한 환경을 조성함으로써 자기 또는 타인의 위험을 내포하고 있는 정신질환자 또한 안전한 환경에서 정신의료기관으로 이송될 수 있는 계기가 될 것이다.