• 제목/요약/키워드: Shunt resistors

검색결과 26건 처리시간 0.027초

동적제어에 의한 전력계통의 과도제어 특성 해석 (Transient Control Analysis of Power System by Dynamic Braking)

  • 김준현;설용태
    • 대한전기학회논문지
    • /
    • 제31권11호
    • /
    • pp.125-132
    • /
    • 1982
  • This paper analyzes the transient control characteristics of power system by dynamic braking. This method, one type of network switching, employs the injection of controllable shunt resistors at or near the generator bus after the disturbances. First, the power system is simulated mathematically for applying the dynamic braking. And the electrical transient control characteristics are considered by controlling the brake size and insertion time. Second, the mechanical torque of turbine-generator is calculted for the mechanical characteristics. This analysis results show that the electrical characteristics are improved but the turbine-generator shaft is impacted by brake switching. However, these problems can be solved by controlling the brake dynamically.

  • PDF

2개의 레그-션트 저항을 이용한 3상 인버터의 상 전류 측정 방법 및 측정 영역 분석 (Phase Current Measurement Method for 3-Phase Inverter with Two Leg-Shunt Sensing Resistors)

  • 유정목;정재엽
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.210-211
    • /
    • 2016
  • 션트 저항을 이용하여 3상 인버터의 전류를 측정하는 방법은 가격 경쟁력이 우수하여 다양한 산업 분야에서 응용되고 있다. 본 논문에서는 시스템의 원가를 절감하기 위해 2개의 레그-션트 저항을 이용하여 3상 인버터의 상 전류를 측정하는 방법을 제안하고 측정이 가능한 영역에 대하여 분석한다. 2개의 레그-션트 저항을 이용할 경우 기존 3개의 레그-션트 저항을 이용했을 때보다 시스템의 가격이 감소할 뿐만 아니라 레그-션트 저항에서 발생하는 손실이 감소하여 전체 인버터의 효율이 증가한다는 장점이 있다.

  • PDF

집적화된 Nb DC SQUID 소자의 제작 및 특성 (Fabrication and Characteristics of Integrated Nb DC SQUID)

  • 이용호;권혁찬;김진목;박종철
    • 한국자기학회지
    • /
    • 제2권3호
    • /
    • pp.277-281
    • /
    • 1992
  • 입력코일과 변조코일이 박막 형태로 집적화된 planar DC SQUID를 제작하고 그 특성을 조사하였다. SQUID loop은 균일한 외부자장의 영향을 받지 않도록 두개의 ring이 '8'자형으로 직렬로 연결된 구조를 하고 있으며, 조셉슨 접합으로는 Pd shunt 저항을 가지는 Nb/Al-oxide/Nb 턴넬 접합을 이용하였다. 소자는 포토리소그라피 기술과 RF 마그네트론 스퍼터링 및 양극산화 방법으로 제작하였으며, 제작된 SQUID는 4.2 K에서 기본적인 특성을 측정한 결과 standard readout 시스템에 적합한 매끄러운 특성을 보였으며 전압 잡음은 측정할 수 없을 정도로 작아 white noise는 최대 $10^{-4}\;{\phi}_o/\;\sqrt{H_z}$ 이하로 나타났다. 현재 matching 코일을 사용하여 잡음 특성을 측정중에 있으며 앞으로 SQUID parameter를 최적화할 경우 매우 고감도의 자기센서로 활용될 수 있을것으로 기대된다.

  • PDF

2상 유도전동기의 벡터제어를 위한 저가형 전류측정 방법 (Low-Cost Current Measurement Method for Vector Control of 2-Phase Induction Motor)

  • 오광호;윤덕용
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.634-638
    • /
    • 2015
  • 2상 유도전동기의 벡터제어를 위해서는 전동기로 입력되는 상전류를 실시간으로 측정해야 한다. 일반적으로 전동기의 상전류는 인버터의 출력단에 2개의 홀전류센서를 삽입하여 측정한다. 그러나, 홀전류센서는 가격이 비싸고, 2상 유도전동기용 벡터제어 인버터는 주로 시스템의 가격이 낮은 저전력 응용분야를 대상으로 연구가 진행되고 있으므로 홀전류센서를 사용하는 것은 경제성 측면에서 부적합하다. 따라서, 본 논문에서는 인버터의 출력단에 고가의 홀전류센서 대신 션트저항을 삽입하고, 이것의 양단 전압을 차동 증폭기로 증폭하여 모든 운전영역에서 정밀하게 상전류를 측정하는 방법을 제안한다. 이를 220[V]/360[W]급의 2상 유도전동기 벡터제어 인버터에 적용하였으며, 제안된 방법의 유효성은 컴퓨터 시뮬레이션과 실험을 통하여 검증하였다.

Current and voltage loading tests off resistive SFCL

  • 최효상;현옥배;김혜림;황시돌;박권배
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.241-246
    • /
    • 2002
  • We have performed the current and voltage loading tests of resistive superconducting fault current limiters (SFCLS) based on $YBa_2$$Cu_3$$O_{7}$(YBCO) films with the diameter of 2 inch. The SFCL consists of meander-type YBCO stripes covered with 200 nm Au layer grown in situ for current shunt and heat dispersion at hot spots. The minimum quench current of an SFCL unit was about 25 Apeak. Seven SFCL units were connected in parallel fur the current load ing tests at power source of 100 $V_{rms}$ $/2,000A_{rms}$. This SFCL units had maximum limiting current of 170 Apeak during the fault instant and then successfully controlled the fault current below 100 Apeak within 1~2 msec after short circuit. Increased short current also reduced the quench completion time with little change of current limiting characterization. We connected six SFCL units in series fur the voltage loading tests at power source of $1,200 V_{rms}$/170 $A_{rms}$ at this time. The shunt resistors were inserted into each SFCL unit to eliminate power imbalance originated from serial connection of SFCL units. Each SFCL unit was quenched simultaneously during the fault condition. The current increased up to 40 $A_{peak}$ and decreased to 14 $A_{peak}$ after 3 cycles. Quench was completed within 1 msec after the fault. We confirmed operating characteristics of 140 kVA($120 A_{rms}$ $\times$ 1,200 $V_{rms}$) SFCL and presented the manufacturing possibility of 3.3 kV SFCL using 4 inch YBCO films.BCO films.lms.

  • PDF

병렬우선 직렬연결된 YBCO박막형 초전도 한류기의 용량증대 (Enhancement of Power Rating for the Resistive Fault Current Limiter)

  • 박권배;이방욱;강종성;오일성;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.806-808
    • /
    • 2004
  • The series and parallel connection is essential for increasing power ratings of resistive type for fault current limiters. To increase voltage class, components are connected in series and to increase current level to the nominal value, they are connected in parallel. There are two ways to connect components in series and parallel. First, connected in series and then the module connects to the parallel. Second, connected in parallel and the module connects to the series. We have studied for the two ways. In this paper, we particularly investigated way to connect components in parallel first This way has the advantage of inducing effective simultaneous quench without any other devices, for example, the thing which is inducing magnetic field to the limiting and shunt resistors. And also we studied for the endurance of component which is patterned to the bi-spiral for prospective fault current. It is very important to understand this, because SFCL will use as the only device to decrease burden of circuit breaker. As experimental results, limiting component patterned to bi-spiral endures fault current up to 30kA and it works well, in parallel to series connection,

  • PDF