• Title/Summary/Keyword: Shoulder strength

Search Result 310, Processing Time 0.022 seconds

Evaluation of Muscle Strength in Korean Adults -center of shoulder muscle group - (한국 성인의 근력 평가에 대한 연굴 - 견부 주위근 중심으로 -)

  • Lee In-Hak;Lee Hyun-Kyung
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.99-104
    • /
    • 1998
  • The purpose of this study was evaluate a isometric shoulder mused strength of normal college student in two groups. 40 college student between the age of $20,47\pm1.96$, weight of $58,50\pm6.78Kg,\;height\;of\;161.87\pm4.91Cm$ were studied. Isometric shoulder strenght was measured by Nicholas hand-held dynamometer far Boxers, extensors, abductors, adductors, external rotators. and internal rotators of shoulders. Testing was Performed with the subject supine according to the modified Bohannon's method and Jae-Wok Kim's method.

  • PDF

Comparison of Muscle Strength between Dominant and Non-dominant Sides of College Students in Their 20s according to Contraction Type (수축 형태에 따른 20대 대학생의 우세 측과 비우세 측의 근력비교)

  • Jong-Hyup Lee;Seung-Kyu Lee;Young-Sun Na;Jeong-Woo Jeon;Jae-Ho Yu;Ji-Heon Hong;Jin-Seop Kim;Dong-Yeop Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.47-53
    • /
    • 2024
  • Purpose : This study investigated the effects of concentric and eccentric contractions on muscle strength using an isokinetic dynamometer (ID) in college students in their 20s. It aimed to understand the impact of differences between the dominant and non-dominant sides on strength asymmetry and to elucidate the clinical implications of these differences to establish an appropriate posture and environment for patients. Methods : The experiment was conducted with 30 healthy adult participants. Prior to the experiment, participants underwent a warm-up targeting the shoulders, and efforts were made to eliminate factors that could potentially influence the measurement results. Subsequently, the maximum safe range of motion of shoulder joint abduction, extension, and flexion was measured using an isokinetic muscle function testing device. Muscle strength was assessed using concentric and eccentric contractions alternating between the dominant and non-dominant sides, and paired sample t-tests were used for the analysis. Results : There was no significant difference between bilateral peak torques for eccentric contraction in shoulder joint abduction, extension, and flexion (p>0.05). There was also no significant difference between bilateral peak torques for concentric contraction in shoulder joint abduction, extension and flexion (p>0.05). Conclusion : This study found no statistically significant difference in muscle strength between the dominant and non-dominant sides during concentric and eccentric contractions. However, previous studies have shown significant differences between the dominant and non-dominant sides during eccentric and concentric contractions during internal shoulder rotation in the general population, as well as significant differences in the upper trapezius muscle. Therefore, further research is needed to support the application of different intensities for bilateral muscle strengthening exercises in clinical practice.

Effect of Chuna (Shoulder Traction) Treatment on Frozen Shoulder During Korean Medical Treatment

  • Jo, Na Young;Yeo, In Ho;Jung, Se Ho;Sung, Hee Jin;Lee, Cham Geol;Lee, Eun Yong;Roh, Jeong Du
    • Journal of Acupuncture Research
    • /
    • v.31 no.2
    • /
    • pp.111-118
    • /
    • 2014
  • Objectives : Through an analysis of the previous studies, It is estimated that Chuna(shoulder traction) is effective in reducing the pain and increasing motion range of shoulder joint of the patient. So this study is to investigate the effects of Chuna(shoulder traction) on frozen shoulder. Methods : After treated with acupuncture and electro stimulating therapy, the subjects were measured list of measurement. And then treated with Chuna(shoulder traction) therapy, the subjects were measured list of measurement again. All treatment was performed by the same doctor who is a highly qualified about Chuna(shoulder traction). Chuna(shoulder traction) treatment takes 15 minutes. Three kind of Chuna(shoulder traction) therapy were performed for 5 minutes each. Depending on the degree of the subject's pain, treatment strength was adjusted. Results : - Chuna simultaneous treatment group, shoulder joint range of flexion, extension, abduction, adduction, external rotation and internal rotation movement improved statistically significant. - Chuna simultaneous and acupuncture treatment group, visual analogue scale(VAS) scores of two groups decreased statistically significant. Conclusions : The result suggests that Chuna(shoulder traction) can be effective to recover range of motion and reduce pain on patients with frozen shoulder.

Isokinetic Performance and Shoulder Mobility in Pro League Woman Volleyball Players (프로리그 여자 배구 선수들의 어깨 관절 회전 기능에 대한 연구)

  • Lee, Byoung-Kwon;Han, Dong-Wook;Kang, Kyung-Hee
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.4
    • /
    • pp.45-55
    • /
    • 2007
  • We investigated the biomechanics and characteristics of shoulder rotator muscles for professional woman volleyball players. The purpose of this study was to analyze the isokinetic peak torque and range of motion for shoulder joint rotation. We measured the strength and ROM of the internal rotation(IR) and external rotation(ER) of shoulders joint for nine professional woman Volleyball players and nine University students with Biodex and Simi-motion. 1. We measured peak torques for the shoulder joint rotator at angular velocities of 60/s and 180/s. It was found that the peak torques were significantly different between the two groups and also between the hands used. 2. At angular velocity of 60/s, IR/ER ratio of the shoulder joint was significantly different depending on the groups and the hands in use. There was a significant difference for 'Dominant side' at angular velocity of 180/s, but no significant difference for 'Non-dominant side' and the controls group. 3. Regarding the ROM of rotation of the shoulder joint group, IR was significantly different between the groups and the hands in use. 4. IR/ER ratio of the shoulder joint for Dominant side was quite different between the groups.

Effect on Improvement of Muscle Strength for Loading Pattern using Electric Exercise Instrument (전동식 운동기기의 부하방식에 따른 근력증진 효과)

  • Kang, Seung-Rok;Kim, Kyung;Jeong, Gu-Young;Seo, Young-Bum;Jeong, Jang-Sik;Kim, Jung-Ja;Kwon, Tae-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.2
    • /
    • pp.229-238
    • /
    • 2012
  • This study is to compare muscle strength between isotonic exercise and isotonic & isokinetic exercise. Participants are 12-man and 10-woman whom they are healthy without medical history in shoulder, elbow and lumbar joint. We performed experiment total 4-weeks that exercise 3-days a week each exercise pattern. We measured shoulder, elbow and lumbar joint torque with BIODEX and circumference of muscle in upper arms once a week. The result showed that isotonic & isokinetic exercise pattern significantly more improved joint torque in shoulder, elbow, lumbar than isotonic exercise pattern. Because that isotonic & isokinetic exercise pattern supplied muscle strengthen and caused muscle contraction. This exercise pattern can be used new exercise training method for major athlete and normal people. Also this pattern can be used rehabilitation treatment.

A Study on the Finite Element Analysis in Friction Stir Welding of Al Alloy (알루미늄 합금재의 마찰교반용접 유한요소해석에 관한 연구)

  • Lee, Dai Yeal;Park, Kyong Do;Kang, Dae Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.5
    • /
    • pp.81-87
    • /
    • 2015
  • In this paper, the finite element method was used for the flow and strength analysis of aluminum alloy under friction stir welding. The simulations were carried out using Sysweld s/w, and the modeling of the sheet was executed using Unigraphics NX6 s/w. The welding variables for the analysis were the shoulder diameter, rotating speed, and welding speed of the tool. Additionally, a three-way factorial design method was applied to confirm the effect of the welding variables on the flow and strength analysis with variance analysis. From these results, the rotating speed had the greatest influence on the maximum temperature, and the maximum temperature was $578.84{\pm}12.72$ at a confidence interval of 99%. The greater the rotating speed and shoulder diameter, the greater the difference between maximum and minimum temperature. Furthermore, the shoulder diameter had the largest influence on von Mises stress, and the von Mises stress was $184.54{\pm}12.62$ at a confidence interval of 99%. In addition to the increased shoulder diameter, welding speed, and rotating speed of the tool increased the von Mises stress.

Correlation between Subscapularis Tears and the Outcomes of Physical Tests and Isokinetic Muscle Strength Tests

  • Jang, Ho-Su;Kong, Doo-Hwan;Jang, Suk-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.2
    • /
    • pp.90-95
    • /
    • 2016
  • Background: The aim of this study was to investigate the correlation between the type of subscapularis tendon tears diagnosed during arthroscopy and the outcomes of physical tests and of isokinetic muscle strength tests. Methods: We preoperatively evaluated physical outcomes and isokinetic muscle strength of 60 consecutive patients who underwent an arthroscopic rotator cuff repair and/or subacromial decompression. We divided the patients into five groups according to the type of subscapularis tear, which we classified using Lafosse classification system during diagnostic arthroscopic surgery. Results: When we performed a trend analysis between the outcomes of the physical tests and the severity of subscapularis tendon tear, we found that both the incidence of positive sign of the collective physical tests and that of individual physical tests increased significantly as the severity of the subscapularis tear increased (p<0.001). Similarly, the deficit in isokinetic muscle strength showed a tendency to increase as the severity of subscapularis tear increased, but this positive correlation was statistically significant in only the deficit between those with Lafosse type II tears and those with Lafosse type III tears. Conclusions: Although no single diagnostic test surpasses above others in predicting the severity of a subscapularis tear, our study implies that, as a collective unit of tests, the total incidence of the positive rate of the physical tests and the extent of isokinetic strength deficit may correlate with severity of subscapularis tears.

Rotator cuff repair with or without proximal end detachment for long head of the biceps tendon tenodesis

  • Mardani-Kivi, Mohsen;Asadi, Kamran;Izadi, Amin;Leili, Ehsan Kazemnejad
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.2
    • /
    • pp.101-105
    • /
    • 2022
  • Background: Rotator cuff tears cause pathologies of the long head of the biceps tendon (LHBT). One of the surgical treatments for such a tear is LHBT tenodesis to the humerus. This study aims to compare simultaneous rotator cuff repair and LHBT tenodesis with or without detachment of the proximal end of the LHBT (PELHBT) from its site of adhesion to the glenoid. Methods: This retrospective study involved patients affected by LHBT pathology with rotator cuff tear. The patients were divided into two groups, with or without PELHBT detachment from the glenoid. Therapeutic outcomes were investigated by evaluation of patient satisfaction, pain based on visual analog scale, shoulder function based on Constant score and simple shoulder test, and biceps muscle strength based on the manual muscle testing grading system before surgery, at 6 months, and at the final visit after surgery. Results: Groups 1 and 2 comprised 23 and 26 patients, respectively, who showed no significant differences in demographic characteristics (p>0.05). Shoulder function, biceps muscle strength, pain, and satisfaction rate improved over time (p<0.05) but were not significantly different between the two groups (p>0.05). No post-surgical complication was found in either group. Conclusions: There was no difference in final outcomes of tenodesis with or without detachment of the PELHBT from the supraglenoid tubercle. Such tendon detachment is not necessary.

Tensile Strength of Provisional Cement on Natural Abutment and Metal Abutment (자연 지대치와 금속 지대치 상에서 임시 접착제의 인장력에 관한 연구)

  • Lee, Il-Kwon;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.20 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • STATEMENT OF PROBLEM: Tensile strength of metal crown cemented with provisional cement have shown clinically difference between metal abutment of implant and natural abutment. PURPOSE: This study was tested to compare the tensile strength of provisional cement on the natural abutment and metal abutment. MATERIAL AND METHODS: Out of the 20 premolars that were selected for this experiment, each 10 were prepared of abutments by chamfer and rounded shoulder margin and then duplicated to produce 20 metal abutments that were same to natural teeth. Then, crowns were fabricated to fit the total 40 natural & metal abutments to be cemented by cavitec, to be added of regular, repetitive vertical load, and to be measured of tensile strength by using Universal Test Machine. RESULTS: There was statistically significant difference in the tensile strength between the crowns cemented to the natural & metal abutments, but no statistically significant difference was observed between the chamfer and the shoulder gingival margin of the each abutments. CONCLUSIONS: Tensile strength of metal teeth is greater about 2 more times than that of natural teeth when it is cemented with Cavitec.

Effects of Isometric Upper Limb Contraction on Trunk and Leg Muscles During Sit-to-stand Activity in Healthy Elderly Females

  • Jang, Eun-Mi;Oh, Jae-Seop;Kim, Mi-Hyun
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.12 no.1
    • /
    • pp.61-66
    • /
    • 2017
  • PURPOSE: The purpose of this study was to investigate the effects of isometric upper limb contraction on the trunk and lower extremity muscles during the sit-to-stand activity in elderly females. METHODS: Eighteen healthy elderly females performed three directional isometric upper extremity contractions (flexion, extension, and horizontal abduction movements) using an elastic band during sit-to-stand activity. Electromyography signals were collected from the internal oblique, erector spinae, rectus femoris, and biceps femoris muscles. RESULTS: Internal oblique activity was greater in bilateral shoulder flexion and bilateral shoulder horizontal abduction than in neutral position (p<.05). Erector spinae and rectus femoris muscle activities in bilateral shoulder flexion was greater than in neutral position and bilateral shoulder extension (p<.05). Biceps femoris activity was significantly greater in bilateral shoulder flexion than in bilateral shoulder extension and horizontal abduction, and in neutral position compared to bilateral shoulder extension (p<.05). CONCLUSION: These results suggest that incorporating isometric upper limb contraction may be beneficial for enhancing the contribution of trunk and lower extremity muscle activities to trunk stabilization during sit-to-stand activity. Therefore, isometric upper limb contraction during sit-to-stand tasks, especially in flexion, may be used to elicit contraction of the lumbopelvic region muscles within a tolerable range, for developing endurance and strength in the elderly.