  • Effects of gas formers of MgCO$_3$, CaCO$_3$ and Li$_2$CO$_3$ on the spattering phenomena were investigated for non-shielded flux cored arc welding. Spattering phenomena were pictured using high speed camera as a speed of 3000 frames per sec. As experimental results, spattering modes were classified into 4 types. The modes were spattering by arc force, gas explosion, short circuit and pore escape. The amount of spatters by arc force was 30%, gas blowing force was 40%, short circuit 10%, pore escape was 10% and others were 10%. When Li$_2$CO$_3$ was added, the amount of spatters was largest, and it decreased in the order of CaCO$_3$ and MgCO$_3$.

  • PDF

부스바(Busbar)형 전기접점의 단락통전성능 해석기법 개발 (Development of the Analysis Technology for Short Circuit Current Capability of Busbar-Type Electrical Contacts)

  • 오연호;송기동;김진기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권1호
    • /
    • pp.27-32
    • /
    • 2005
  • This study presents an analysis technique that can consider all variables which are needed in the design of short circuit current capability of electrical contacts. Required variables in the design are material of contact, contacting area, applied force, asperity of surface, current and so on. Short circuit current capability test was carried out for the interrelation of design variables and the verification of analysis technique. Temperature rise equation of the contacts was obtained from the test results, and also, a standard that is criterion of the occurrence availability of melting or spot of contact surface from test results was established.

차단기와 모선과의 연결시 가터스프링에 의한 접촉력의 측정 및 설계 고찰 (Measurement and Design Review of Contact Force by Garter Spring in Connection between Circuit Breaker and Bus Bar)

  • 조상순;안길영;박우진;오일성
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.942-945
    • /
    • 2002
  • A garter spring, which is a long. special, close-coiled extension spring with its ends joined to form a ring, is used in connection between vacuum circuit breaker and bus bar in switchgear. To carry short-time current and resist welding at the contact surface in the connection, the garter spring must transmits an uniform contact force to the contact surface through the contact chips arranged in the circumference of bus bar. In this paper, the system for measurement of the contact force by the garter spring is developed. Using the developed measurement system, the design of the connection structure including the garter spring is reviewed to obtain the uniform contact forces in all of contact chips.

  • PDF

케이블 삼상단락 실증시험을 통한 전자력 대책방안 검토 (The Study on Countermeasures of Electromagnetic Force by Three Phase Short-Circuit Test of Cable)

  • 홍동석;김해준;박성민;장우석;박흥석;장태인;강지원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.363_364
    • /
    • 2009
  • Even though underground transmission cable is an essential transmission method to supply stable power for downtown and population center, interaction of electromagnetic force from fault current is very large comparing to overhead transmission line due to restricted installation space such as tunnel, etc. and close consideration is required for it. This paper presents countermeasures to reduce and release the effect of electromagnetic force with rope binding and installation of spacer and describes its efficacy through three phase short-circuit test, which will be utilized as basic materials for improvement and development of cleat, hanger, etc. to reduce and release effect of electromagnetic force in the future.

  • PDF

전하증폭기를 사용하지 않은 고분자 압전센서 신호를 이용한 복합재 평판의 저속충격 탐지 (Low-Velocity Impact Detection of Composite Plate Using Piezopolymer Sensor Signals without Charge Amplifier)

  • 김인걸;정석모
    • Composites Research
    • /
    • 제13권6호
    • /
    • pp.47-54
    • /
    • 2000
  • 복합재 구조물의 저속충격탐지 방법 중의 하나는 고분자 압전센서를 이용하는 것이다. 본 논문에서는 저속충격을 받는 복합재 평판에 대한 충격력과 부착된 스트레인 게이지, 고분자 압전센서 신호와의 관계를 유도하였다. 압전센서의 등가회로도를 통해서 고분자 압전센서의 개회로 신호와 폐회로 신호와의 관계를 유도하여 전하증폭기를 사용하지 않은 고분자 압전센서 신호를 이용하여 복합재 평판의 충격력 복원 가능성에 대한 연구로 확장하였다. 진동실험을 통하여 얻은 복합재 평판의 고유진동수와 감쇠비를 이용하여 해석적인 모델을 수정하여 정방향 문제와 역방향 문제에 있어서 오차를 줄일 수 있었다. 복원된 충격력과 해석적인 센서 신호는 실제 저속 충격 실험을 통하여 측정한 충격력, 스트레인 게이지 신호, 그리고 고분자 압전센서 신호와 잘 일치하였다.

  • PDF

이종초전도 코일을 이용한 하이브리드형 한류기의 제작 및 단락실험 (Fabrication and Small scale Short Circuit Tests of Hybrid Fault Current Limiter Employing Asymmetric Non-Inductive Coil and Fast Switch)

  • 장재영;김영재;나진배;최석진;이우승;이창영;박동근;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.41-45
    • /
    • 2011
  • Hybrid fault current limiters (FCL) have been researched at Yonsei University. The hybrid FCL has advantages such as having a rapid response to a sudden fault situation and a fast recovery time from a quench. It consists of an asymmetric HTS coil, a switching module, and a bypass reactor. The asymmetric HTS coil is wound with two different types of HTS wires in an opposite direction so that it has nearly zero inductance at the superconducting state. When the quench occurs at the fault state, a strong magnetic field is generated from the asymmetric coil because of different quench characteristics of two HTS wires, and then a repulsive force is induced in the switching module. The force opens the switch and the fault current is pushed into the bypass reactor. In this research, we analyzed the cause of the repulsive force and confirmed, experimentally and computationally, that the magnitude of a repulsive force is varied by changing the gap distance between the asymmetric coil and the switching module. By using the FEM simulation, we calculated the repulsive force with respect to the gap distance and verified that the effect of the gap distance. Then, short circuit test was carried out to confirm the correct operation of the fast switch.

Zig-Zag 귄선에 의한 내철형 주상변압기 개발에 관한 연구 (A study on the Development of the Shell-type Pole Transformer Using the Zig-Zag Winding)

  • 민윤홍;신대철
    • 조명전기설비학회논문지
    • /
    • 제21권8호
    • /
    • pp.121-128
    • /
    • 2007
  • 본 논문에서는 세계최초로 내철형 주상변압기 코일의 권선을 일반적인 권선방법에서 Zig-Zag(가칭) 권선방법으로 설계 제작하는 방법을 제안하였으며, 또한 바니시 함침공정을 생략하고 단락강도 및 절연내력을 향상시킬 수 있는 내철형 변압기용 권선의 신프레임 구조개발 내용을 제안하였다. 기존의 주상변압기 권선방법에 비하여 전기절연 측면에서 층간 절연지의 사용매수 및 두께를 획기적으로 절감할 수 있는 장점이 있다. 또한 원가절감과 손실저감 및 단락기계력 대처능력이 우수함을 검증하였으며 국내전력회사 배전계통 주상변압기에 유용하게 활용할 수 있다.

이중전압원 분리를 이용한 PMSM의 센서리스 제어 (A Sensorless PMSM Control Using the Separation of Two Voltage Source)

  • Jin-Woo Ahn;Sung-Jun Park;Dong-Hee Lee
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권1호
    • /
    • pp.1-7
    • /
    • 2004
  • This paper presents a sensorless control strategy of a PMSM(Permanent Magnet Sycchoronous Motor). This method is very simple to compute the position angle of a rotor. A principle and a practical solution are described. A sensorless control algorithm is proposed to remove a mechanical position sensor. The theory is based on the superposition principle. The state equation of a motor is divided into two conditions: one is the state equation of exciting voltage and phase current in a constraint, the other is the state equation of back EMF(Electromotive Force) and phase current in a short circuit. Based on the analysis, short circuit current by back EMF is computed and then the information of position angle is calculated. The proposed method is verified by experimental results.

유한요소법에 의한 초전도 동기발전기의 단락특성 해석 (Finite to Element Analysis of Short Circuit Characteristics of 20 KVA Superconducting Synchronous Generator)

  • 이병석;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.17-20
    • /
    • 1988
  • The most important thing in design procedure of SCG is the exact estimation of the electromagnetic force acting on the field and amature winding. Until now, equivalent circuit method was used for the analysis or electric and magnetic performance. This paper sheds the leo dimensional analysis of electric and magnetic characteristics of SCG by Finite Element Method(FEM). Analysis by FEM provides more areolate results than that of equivalent circuit method because harmonics field generated by field current can he considered. Circuit and field equations are combined together in a equation and solved simultaneously.

  • PDF

7.2kV급 로타리아크식 $SF_6$가스 전자접촉기 소호부 개발연구 (Development of Model Interrupter of 7.2kV $SF_6$ Gas Electromagnetic Contactor Using Rotary Arc Principle)

  • 장기찬;신영준;박경엽;정진교;김진기;김귀식;이승학
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.30-32
    • /
    • 1995
  • The model interrupters of $SF_6$ gas electromagnetic contactor whose ratings are the voltage of 7.2kV and the short circuit current of 4.0kA have been designed and manufactured on the basis of theoretical and computational analysis for its development. The eddy current analysis, the magnetic field analysis and the calculation of the rotational force on arcs have been conducted using FLUX2D package. The short circuit current interrupting tests have been conducted to the model interrupters using the simplified capacitive synthetic test circuit in KERI. The results show that the model interrupters have a sufficient interrupting capability and the new design concept is proper for a good interrupting performance.