• 제목/요약/키워드: Short implant

검색결과 188건 처리시간 0.025초

Improvement of Boron Penetration and Reverse Short Channel Effect in 130nm W/WNx/Poly-Si Dual Gate PMOSEET for High Performance Embedded DRAM

  • Cho, In-Wook;Lee, Jae-Sun;Kwack, Kae-Dal
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(2)
    • /
    • pp.193-196
    • /
    • 2002
  • This paper presents the improvement of the boron penetration and the reverse short channel effect (RSCE) in the 130nm W/WNx/Poly-Si dual gate PMOSFET for a high performance embedded DRAM. In order to suppress the boron penetration, we studied a range in the process heat budget. It has shown that the process heat budget reduction results in suppression of the boron penetration. To suppress the RSCE, we experimented with the halo (large tilt implantation of the same type of impurities as those in the device well) implant condition near the source/drain. It has shown that the low angle of the halo implant results in the suppression of the RSCE. The experiment was supported from two-dimensional(2-D) simulation, TSUPREM4 and MEDICI.

  • PDF

임상가를 위한 특집 3 - 심하게 흡수된 치조제를 가진 환자에서 CAD/CAM을 이용한 임플란트 고정성 보철치료 (Implant fixed prosthetic treatment using CAD/CAM system in a patient with severe alveolar resorption)

  • 최유성
    • 대한치과의사협회지
    • /
    • 제50권3호
    • /
    • pp.126-139
    • /
    • 2012
  • Loss of dentition can lead to not only compromised esthetics and functions of the patient, but also alveolar bone resorption. Bone grafting with prosthetic reconstruction of the gingiva can be selected for the treatment, and it provides many benefits as prosthetic gingival reconstruction does not require a complicated surgical process and is available within a short period of time, with stable clinical results. However, conventional porcelain fused to metal prosthesis has certain limits due to its size, and deformation after several firing procedures. In this clinical report, the author would like to introduce a patient with severe alveolar resorption who was treated with gingiva-shaped zirconia/titanium CAD/CAM implant fixed prosthesis for esthetic and functional rehabilitation. Clinical reports Clinical report 1, 2 : A case of loss of anterior dentition with atrophied alveolar bone. Implant retained zirconia bridge applied with Procera implant bridge system to simulate the gingiva. Upper structure was fabricated with zirconia all ceramic crown. Clinical report 3, 4 : A case of atrophied maxillary alveolus was reconstructed with fixed implant prosthesis, a CAD/CAM designed titanium structure covered wi th resin on its surface. Anterior dentition was reconstructed with zirconia crown. Conclusion and clinical uses. All patients were satisfied with the outcome, and maintained good oral hygiene. Zirconia/titanium implant fixed prosthesis fabricated by CAD/CAM system was highly accurate and showed adequate histological response. No critical failure was seen on the implant fixture and abutment overall. Sites of severe alveolar bone loss can be rehabilitated by implant fixed prosthesis with CAD/CAM system. This type of prosthesis can offer artificial gingival structure and can give more satisfying esthetics and functions, and as a result the patients were able to accept the outcome more fondly, which makes us less than hard to think that it can be a more convenient treatment for the practitioners.

A novel classification of anterior alveolar arch forms and alveolar bone thickness: A cone-beam computed tomography study

  • Bulyalert, Atcharee;Pimkhaokham, Atiphan
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.191-199
    • /
    • 2018
  • Purpose: This study classified alveolar arch forms and evaluated differences in alveolar bone thickness among arch forms in the anterior esthetic region using cone-beam computed tomography (CBCT) images. Materials and Methods: Axial views of 113 CBCT images were assessed at the level of 3 mm below the cementoenamel junction (CEJ) of the right and left canines. The root center points of teeth in the anterior esthetic region were used as reference points. Arch forms were classified according to their transverse dimensions and the intercanine width-to-depth ratio. The buccolingual alveolar bone thickness of each tooth was measured at 3 mm below the CEJ and at the mid-root level. Differences in the mean thicknesses among arch forms were analyzed. Results: Anterior maxillary arches could be classified as long narrow, short medium, long medium, and long wide arches. Significant differences in buccolingual alveolar bone thickness among the arch groups were found at both levels. The long wide arches presented the greatest bone thickness, followed by the long medium arches, while the long narrow and short medium arches were the thinnest. Conclusion: Arch forms were classified as long narrow, short medium, long medium, and long wide. The buccolingual alveolar bone thickness exhibited significant differences among the arch forms.

Implant Removal after Percutaneous Short Segment Fixation for Thoracolumbar Burst Fracture : Does It Preserve Motion?

  • Kim, Hyeun Sung;Kim, Seok Won;Ju, Chang Il;Wang, Hui Sun;Lee, Sung Myung;Kim, Dong Min
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권2호
    • /
    • pp.73-77
    • /
    • 2014
  • Objective : The purpose of this study was to evaluate the efficacy of implant removal of percutaneous short segment fixation after vertebral fracture consolidation in terms of motion preservation. Methods : Between May 2007 and January 2011, 44 patients underwent percutaneous short segment screw fixation due to a thoracolumbar burst fracture. Sixteen of these patients, who underwent implant removal 12 months after screw fixation, were enrolled in this study. Motor power was intact in all patients, despite significant vertebral height loss and canal compromise. The patients were divided into two groups by degree of osteoporosis : Group A (n=8), the non-osteoporotic group, and Group B (n=8), the osteoporotic group. Imaging and clinical findings including vertebral height loss, kyphotic angle, range of motion (ROM), and complications were analyzed. Results : Significant pain relief was achieved in both groups at final follow-up versus preoperative values. In terms of vertebral height loss, both groups showed significant improvement at 12 months after screw fixation and restored vertebral height was maintained to final follow-up in spite of some correction loss. ROM (measured using Cobb's method) in flexion and extension in Group A was $10.5^{\circ}$ ($19.5/9.0^{\circ}$) at last follow-up, and in Group B was $10.2^{\circ}$ ($18.8/8.6^{\circ}$) at last follow-up. Both groups showed marked improvement in ROM as compared with the screw fixation state, which was considered motionless. Conclusion : Removal of percutaneous implants after vertebral fracture consolidation can be an effective treatment to preserve motion regardless of osteoporosis for thoracolumbar burst fractures.

Factors Associated with the Stability of Two-part Mini-implants for Intermaxillary Fixation

  • Kim, Seong-Hun;Seo, Woon-Kyung;Lee, Won;Kim, In-Soo;Chung, Kyu-Rhim;Kook, Yoon-Ah
    • Journal of Korean Dental Science
    • /
    • 제2권2호
    • /
    • pp.24-30
    • /
    • 2009
  • Two component orthodontic C-implants have been introduced as intermaxillary fixation (IMF) screws in cases of periodontal problems with bone loss, severely damaged teeth, or short roots. This retrospective research sought to investigate the complications and risk factors associated with the failure of two-part C-implants for IMF cases and to show the possible indications compared to one-component mini-implants. The study sample consisted of 46 randomly selected patients who had a total of 203 implants. Pearson chi-square tests of independence were used to test for associations among categorical variables. At least 19 of the total 203 implants failed (9.3%). There was no significant difference in implant failure due to gender, oral hygiene, and placement, although a significant difference due to soft tissue characteristics and root contact was observed. The two-component design of the mini-implant is reliable for difficult IMF cases. Note, however, that the factors influencing implant failure were found to be age, root damage, and condition of soft tissues.

  • PDF

슬관절 전치환술용 3차원 시술변수 추출 시스템 (A Simulation System of Total Knee Replacement Surgery for Extracting 3D Surgical Parameters)

  • 전용태
    • 한국CDE학회논문집
    • /
    • 제16권5호
    • /
    • pp.315-322
    • /
    • 2011
  • The goal of total knee replacement (TKR) surgery is to replace patient's knee joint with artificial implants in order to restore normal knee joint functions. Since mismatched knee implants often cause a critical balancing problem and short durability, designing a well-fitted implant to a patient's knee joint is essential to improve surgical outcomes. We developed a software system that three-dimensionally (3D) simulates TKR surgery based upon 3D knee models reconstructed from computed tomography (CT) imaging. The main task of the system was to extract precise 3D anatomical parameters of a patient's knee that were directly used to determine a custom fit implant and to virtually perform TKR surgery. The virtual surgery was simulated by amputating a 3D knee model and positioning the determined implant components on the amputated knee. The test result shows that it is applicable to derive surgical parameters, determine individualized implant components, rehearse the whole surgical procedure, and train medical staff or students for actual TKR surgery. The feasibility and verification of the proposed system is described with examples.

Effects of abutment diameter, luting agent type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments

  • Safari, Sina;Ghavam, Fereshteh Hosseini;Amini, Parviz;Yaghmaei, Kaveh
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권1호
    • /
    • pp.1-7
    • /
    • 2018
  • PURPOSE. The aim of this study was to evaluate the effects of abutment diameter, cement type, and re-cementation on the retention of implant-supported CAD/CAM metal copings over short abutments. MATERIALS AND METHODS. Sixty abutments with two different diameters, the height of which was reduced to 3 mm, were vertically mounted in acrylic resin blocks with matching implant analogues. The specimens were divided into 2 diameter groups: 4.5 mm and 5.5 mm (n=30). For each abutment a CAD/CAM metal coping was manufactured, with an occlusal loop. Each group was sub-divided into 3 sub-groups (n=10). In each subgroup, a different cement type was used: resin-modified glass-ionomer, resin cement and zinc-oxide-eugenol. After incubation and thermocycling, the removal force was measured using a universal testing machine at a cross-head speed of 0.5 mm/min. In zinc-oxide-eugenol group, after removal of the coping, the cement remnants were completely cleaned and the copings were re-cemented with resin cement and re-tested. Two-way ANOVA, post hoc Tukey tests, and paired t-test were used to analyze data (${\alpha}=.05$). RESULTS. The highest pulling force was registered in the resin cement group (414.8 N), followed by the re-cementation group (380.5 N). Increasing the diameter improved the retention significantly (P=.006). The difference in retention between the cemented and recemented copings was not statistically significant (P=.40). CONCLUSION. Resin cement provided retention almost twice as strong as that of the RMGI. Increasing the abutment diameter improved retention significantly. Re-cementation with resin cement did not exhibit any difference from the initial cementation with resin cement.

중공을 가지는 치과용 임플란트의 3차원 응력해석 (Three Dimensional Stress Analysis of a Dental Implant with Central Cavity)

  • 김진곤;이재곤
    • 한국산학기술학회논문지
    • /
    • 제12권5호
    • /
    • pp.2197-2202
    • /
    • 2011
  • 본 논문에서는 중공을 가지는 짧은 치과용 임플란트의 생체역학적인 특성을 3차원 유한요소해석을 통하여 분석하였다. 고려된 치과용 짧은 임플란트는 골유착성을 향상시키기 위해 트리패닝 드링 등에 의해 남겨진 치골과 결합될 수 있는 중공부를 가진다. 연구를 위해 Bicon사의 길이가 짧은 임플란트를 기본 모델로 삼아 중공부가 임플란트 주변 치골의 응력분포에 주는 영향을 분석하였다. 중공부 길이, 직경 및 나사산 등의 형상변수에 따른 반복적인 유한 요소해석을 효과적으로 수행하기 위하여 ANSYS APDL을 이용하여 매개변수화된 유한요소모델을 구성하였다. 해석결과 중공부를 가지는 경우 특히 경사하중 하에서 해면골에서 발생하는 최대응력값이 크게 감소하였으며, 중공부의 형태가 해면골에서의 응력분포에 큰 영향을 주는 것으로 나타났다.

Implant placement with inferior alveolar nerve repositioning in the posterior mandible

  • Doogyum Kim;Taeil Lim;Hyun-Woo Lee;Baek-Soo Lee;Byung-Joon Choi;Joo Young Ohe;Junho Jung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권6호
    • /
    • pp.347-353
    • /
    • 2023
  • This case report presents inferior alveolar nerve (IAN) repositioning as a viable approach for implant placement in the mandibular molar region, where challenges of severe alveolar bone width and height deficiencies can exist. Two patients requiring implant placement in the right mandibular molar region underwent nerve transposition and lateralization. In both cases, inadequate alveolar bone height above the IAN precluded the use of short implants. The first patient exhibited an overall low alveolar ridge from the anterior to posterior regions, with a complex relationship with adjacent implant bone level and the mental nerve, complicating vertical augmentation. In the second case, although vertical bone resorption was not severe, the high positioning of the IAN within the alveolar bone due to orthognathic surgery raised concerns regarding adequate height of the implant prosthesis. Therefore, instead of onlay bone grafting, nerve transposition and lateralization were employed for implant placement. In both cases, the follow-up results demonstrated successful osseointegration of all implants and complete recovery of postoperative numbness in the lower lip and mentum area. IAN repositioning is a valuable surgical technique that allows implant placement in severely compromised posterior mandibular regions, promoting patient comfort and successful implant placement without permanent IAN damage.

How Can We Improve Crown-Implant Ratio in Reconstructed Mandible with Fibular Free Flap?: A New Surgical Technique Using 3D RP Model and Reconstruction Titanium Plates

  • Kim, Dong-Young;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • 제4권1호
    • /
    • pp.13-16
    • /
    • 2017
  • Fibular free flap reconstruction is the flap of the choice in long-span mandibular bone reconstruction. The most common disadvantage of the fibular flap is short bone height to install dental implant. Double barrel fibular flap has been tried, however, bulky flap in the oral cavity hinder its use. Titanium reconstruction plate has been used simultaneously with the free fibular flap to stabilize occlusion and to fix the fibular flap. In this study, titanium reconstruction plate was fixed in the lower border of the mandible and the fibular free flap was fixed in the superior border of the titanium plate to improve implant-crown ratio. This new technique improved the longevity of the dental prosthodontics with dental implants.