• Title/Summary/Keyword: Short current

Search Result 2,906, Processing Time 0.043 seconds

Development of HTS-FCL Location Selection Program in Power System (초전도한류기의 최적 적용위치 선정 프로그램 개발)

  • 최흥관;윤재영;김종율;이승렬;이병준
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.205-208
    • /
    • 2003
  • Maximum short circuit current of modern power system is becoming so large that the current should transmission capability. Although there are various kinds of method to solve this, approached from super conductivity Fault Current Limiter application viewpoint among them. High Temperature Superconductor-Fault Current Limiter (HTS-FCL) development is progressing according to HTS technology development, and system application is tried. For actual system application of such super conductivity FCL, an efficient method to find FCL locations suitable for reduction of short circuit currents of more than one fault location is developed.

  • PDF

The study of short-circuit breaking characteristics of high-voltage alternating current switch-fuse combinations (교류 스위치-퓨우즈 조합기기의 차단특성에 관한 고찰)

  • Roh Chang-il;La Dae-Ryeol;Kim Sun-Koo;Jung Heung-Soo;Kim Won-Man;Lee Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.836-838
    • /
    • 2004
  • Alternating current switch-fuse combinations shall be designed so as to protect for load circuit of distribution line. this switch system shall be test on making and breaking at short-circuit current. the test dutys were performed to prove correct coordination between the switch and fuses in applied test conditions This paper describes characteristics and test method for prove to performance of alternating current switch-fuse combinations.

  • PDF

Development of HTS-FCL Location Selection Program in Power System (초전도한류기의 계통적용점 선정 프로그램 개발)

  • Choi, Heung-Kwan;Yoon, Jae-Young;Kim, Jong-Yeul;Lee, Seung-Ryul;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.321-323
    • /
    • 2003
  • Maximum short circuit current of modern power system is becoming so large that the current should transmission capability. Although there are various kinds of method to solve this, approached from super conductivity Fault Current Limiter application viewpoint among them. High Temperature Superconductor-Fault Current Limiter(HTS-FCL) development is progressing according to HTS technology development, and system application is tried. For actual system application of such super conductivity FCL, an efficient method to find FCL locations suitable for reduction of short circuit currents of more than one fault location is developed.

  • PDF

Single Current Sensor Technique considering a Snubber Current and a Modified SVPWM Inverter for AC Motor Drives (스누버 전류를 고려한 개선된 SVPWM 인버터를 이용한 상전류센서없는 전동기 구동)

  • 주형길;신휘범;안희욱;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.399-402
    • /
    • 1999
  • The single sensor technique reconstructing phase currents from the dc-link current without phase current sensors in proposed. When the duration of active vector is too short for the snubber current to reduce, the dc-link current including the snubber current gives large detection error. The solution is presented by analyzing the snubber current and modifying the switching sequences. This scheme is simple, requires only one sampling a period and has good results for detecting the phase currents.

  • PDF

Analysis on Current Limiting Characteristics of Flux-Lock Type SFCL Using a Transformer Winding (변압기 권선을 이용한 자속구속형 초전도 전류제한기의 전류제한 특성 분석)

  • Han, Tae-Hee;Lim, Sung-Hun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.2
    • /
    • pp.136-140
    • /
    • 2011
  • The fault current limiting characteristics of the flux-lock type superconducting fault current limiter (SFCL) using a transformer winding were investigated. The suggested flux-lock type SFCL consists of two parallel connected coils on an iron core and the transformer winding connected in series with one of two coils. In this SFCL, the high-TC superconducting (HTSC) element was connected with the secondary side of the transformer. The short-circuit experimental devices to analyze the fault current limiting characteristics of the flux-lock type SFCL using the transformer winding were constructed. Through the short-circuit tests, the flux-lock type SFCL using transformer winding was shown to perform more effective fault current limiting operation compared to the previous flux-lock type SFCL without the transformer winding from the viewpoint of the quench occurrence and the recovery time of the HTSC element.

Electroluminescent Characteristics of Fluorescent OLED with Alternating Current Negative Voltage (교류 음 전압에 따른 형광 OLED의 전계 발광 특성)

  • Seo, Jung-Hyun;Yang, Jae-Woong;Paek, Kyeong-Kap;Ju, Sung-Hoo
    • Journal of Surface Science and Engineering
    • /
    • v.52 no.2
    • /
    • pp.72-77
    • /
    • 2019
  • To study the characteristics of AC driven OLED, we fabricated the fluorescent OLEDs and analyzed the electroluminescence characteristics of OLEDs with AC negative voltage. The luminance and the current density of the OLED decreased, and the number and size of the dark spots increased in proportion to the duration time and level of the applied AC negative voltage. The current efficiency of the OLED was improved when high AC negative voltage was applied within a short time. When the AC negative voltage of 10 V was applied for 1 minute, the efficiency was improved by 12.4%. Also, the degradation of luminance and current efficiency due to the duration of light emission was improved in the case of OLED applied for 1 minute with 10 V AC negative voltage. These are expected as a result of the improvement of the leakage current characteristics by eliminating the short-circuit region formed by the defect of the OLED at the AC negative high voltage. As a result, the continuous application of AC negative voltage reduced the luminance and the current density of OLED, but the temporary application of AC negative voltage with the proper time and voltage could improve the efficiency and lifetime of OLED.

An Evaluation Method for Short-Term Ratings of Double-Circuit Overhead Transmission Lines (2회선 가공송전선의 단시간정격에 관한 평가방법)

  • Kim, Sung-Duck;Sohn, Hong-Kwan;Jang, Tae-In
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.7
    • /
    • pp.20-28
    • /
    • 2007
  • This paper describes an analytical method to determine the short-term ratings to reliably operate the overhead transmission lines with double-circuit lines when faulting one circuit of the two. As linearizing the thermal equilibrium equation that represents the temperature characteristic of conductors, we show that the linear equation can be easily represented the over-current and it's temperature property during overloading the one line. Generally, it is well hewn that the short-term line ratings should be determined by considering both conductor life and dip. However, most power companies have their own different guides for the short-term ratings. Using the suggested method in this paper, it can be re-accessed the short-term ratings given in Kepco's overhead transmission lines constructed during the past three different periods. As a result, it is verified that the short-term ratings could be increased mil efficiently. Furthermore, it would be directly applied the given method to determine the short-term dynamic line ratings when occurring faults in one of the double-circuit lines, without doing my other actions for the current lines.

Fatigue performance of deepwater SCR under short-term VIV considering various S-N curves

  • Kim, D.K.;Choi, H.S.;Shin, C.S.;Liew, M.S.;Yu, S.Y.;Park, K.S.
    • Structural Engineering and Mechanics
    • /
    • v.53 no.5
    • /
    • pp.881-896
    • /
    • 2015
  • In this study, a method for fatigue performance estimation of deepwater steel catenary riser (SCR) under short-term vortex-induced vibration was investigated for selected S-N curves. General tendency between S-N curve capacity and fatigue performance was analysed. SCRs are generally used to transport produced oil and gas or to export separated oil and gas, and are exposed to various environmental loads in terms of current, wave, wind and others. Current is closely related with VIV and it affects fatigue life of riser structures significantly. In this regards, the process of appropriate S-N curve selection was performed in the initial design stage based on the scale of fabrication-related initial imperfections such as welding, hot spot, crack, stress concentration factor, and others. To draw the general tendency, the effects of stress concentration factor (SCF), S-N curve type, current profile, and three different sizes of SCRs were considered, and the relationship between S-N curve capacity and short-term VIV fatigue performance of SCR was derived. In case of S-N curve selection, DNV (2012) guideline was adopted and four different current profiles of the Gulf of Mexico (normal condition and Hurricane condition) and Brazil (Amazon basin and Campos basin) were considered. The obtained results will be useful to select the S-N curve for deepwater SCRs and also to understand the relationship between S-N curve capacity and short-term VIV fatigue performance of deepwater SCRs.

The Changes of Short Circuit Current Density according to the Post-annealing Temperature of Organic Materials in the Hybrid Photovoltaics (하이브리드 태양전지 제작에 있어서 유기물의 후열처리 온도에 따른 단락전류밀도의 변화)

  • Gwon, Dong-Oh;Shin, Min Jeong;Ahn, Hyung Soo;Yi, Sam Nyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.81-85
    • /
    • 2015
  • The organic/inorganic hybrid photovoltaic devices have been studied using Poly(3-hexylthiophene-2,5-diyl) (P3HT) : [6, 6]-Phenyl C61 butyric acid methyl ester (PCBM) and GaN. We traced the effect of short circuit current density with different annealing method under the various concentration and ratio of P3HT:PCBM. During the pre-annealing course, the heat treatments were performed each time at low temperature after the organic layer coated and the samples were heated at high temperature through one or two steps under the post-annealing process. It revealed that the samples with post-annealing process had higher values of short circuit current density than the other samples upon pre-annealing. And the interesting high short circuit current density features were observed at 1:1 mixing ratio and 1wt% of P3HT:PCBM.

Liquidity Determinants of Private Hospitals in Korea (민간병원의 유동성 관련요인 분석)

  • Choi, Man-Kyu;Lee, Yun-Seok;Lee, Yoon-Hyeon
    • Health Policy and Management
    • /
    • v.12 no.4
    • /
    • pp.1-17
    • /
    • 2002
  • This study was attempted to identify the liquidity trends and determinants of private hospitals in Korea different. Data used in this study were collected from 98 hospitals with complete general data of present conditions as well as financial statements(balance sheets, income statements). They were chosen from hospitals that passed the standardization audit undertaken by the Korean Hospital Association from 1996 to 2000 for the purpose of accrediting training hospitals. The dependent variables in this study were used current ration and quick ratio as a proxy indicator for liquidity. The independent variables were ownership type, hospital type, location, bed size, period of establishment, short-term liabilities to total assets, long-term liabilities to total assets, borrowings to total assets, fixed asset ration, net profit to total assets, operating margin to gross revenue, growth rate of net worth to total assets, total asset turnover, and business risk(volatility of profit). The major findings of this study were as follows. Trends of liquidity(current ratio, quick ratio) had been continuously decreased. Especially, There were very distinct decreasing trends of personal hospitals and less than 300beds, which weakened liquidity. The factors had significant effect on current ratio were short-term debt to total assets(-), fixed asset ratio(-), business risk(+). High short-term debt to total assets, high fixed asset ratio and high business risk significantly decreased in liquidity. The factors that significantly affected on quick ratio were short-term debt to total assets(-), borrowings to total assets(+), fixed asset ratio(-), business risk(+).