• 제목/요약/키워드: Short Tube Orifices

검색결과 11건 처리시간 0.022초

R32/125/134a를 사용한 오리피스 팽창장치의 성능실험 및 모델링 (Experimentation and Modeling of R32/125/134a Flow Through Short Tube Orifices)

  • 김용찬
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.45-54
    • /
    • 1996
  • An experimental investigation on the two-phase flow through tube orifices was performed with the refrigerant mixture of R32/125/134a(30/10/60). A series of tests were conducted to generate wide range of data at varying operation conditions with four short tubes. The tests include both single and two-phase flow conditions at the inlet of the short tube with different oil concentrations. Experimental data were presented as a function of major operating parameters and short tube diameter. Based on test results and data analysis, a semi-empirical flow model was developed to predict the mass flow rate through short tube orifices with a given set of conditions. The flow model was formed to cover both single and two-phase flow at the inlet of short tube with considering the effects of oil concentration.

  • PDF

일반화된 오리피스의 유량예측 상관식 및 유량선도 (A Generalized Flow Model and Flow Charts for Predicting Mass Flow Rate through Short Tube Orifices)

  • 최종민;김용찬;곽재수;권병철
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.895-900
    • /
    • 2004
  • With the phaseout of CFC and HCFC refrigerants, refrigeration and heat pump systems must be redesigned to match and improve system performance with alternative refrigerants. A generalized flow model for predicting mass flow rate through short tube orifices is derived from a power law form of dimensionless parameters generated by Pi-theorem. The database for developing the correlation includes extensive experimental data for R12, R22, R134a, R407C, R410A, and R502 from the open literature. The correlation yields an average deviation of $0.3\%$ and a standard deviation of $6.1\%$ based on the present database. In addition, rating charts for predicting refrigerant flow rate through short tube orifices are generated for R12, R22, R134a, R407C, R410A, and R502.

R-410A 임계영역 운전조건에서 오리피스의 성능특성에 관한 연구 (Performance of Short Tube Orifices Using R-410A Near the Critical Region)

  • 최종민;김용찬
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1106-1112
    • /
    • 2005
  • An experimental investigation was performed to develop an empirical correlation of R-410A flowing through short tube orifices working near the critical region. Tests were executed by varying upstream pressure from 2,619 kPa to 4,551 kPa, and upstream subcooling from 2.8 and $11.1^{\circ}C$. The experimental data were represented as a function of major operating parameters and short tube diameter. As compared to mass flow trends at normal upstream pressures, flow dependency on upstream subcooling became more significant at high upstream pressures due to a higher density change. Based on the database obtained from this study and literature, an empirical correlation was developed from a power law form of dimensionless parameters generated by the Buckingham Pi theorem. The correlation yielded good agreement with the data. Approximately $92\%$ of the data were correlated within a relative deviation of $5\%$.

항공기의 도어 댐퍼용 교축 오리피스의 설계 (Design of Throttle Orifices for an Aircraft Door Damper)

  • 권용철;김종혁;홍예선;김상범
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권3호
    • /
    • pp.23-28
    • /
    • 2012
  • In this study the flow rate-to-pressure difference characteristics of short-tube type damping orifices for an aircraft door damper were investigated by CFD analyses and experiments. As the design parameters of the damping orifice its diameter, inlet and outlet angle, tube length and the viscosity of the working fluid were taken into consideration. The results showed that the discharge coefficient of the orifices are dependant on the inlet and outlet angle and the oil viscosity, while their length plays an little significant role. Although the short-tube type damping orifice was employed to induce a turbulent flow, their discharge coefficient decreases rapidly as the oil viscosity gets higher than 50mm2/s. Therefore, in order to determine the orifice size, satisfying the working temperature range of the door damper, the oil viscosity as well as the friction force on the damper piston should be kept within proper values. For the verification of the CFD analysis results the actual performance of a door damper was measured and compared with them.

Characteristics of Refrigerant Flow through Capillary Tubes and Short Tube Orifices

  • Kim, Yong-Chan;Choi, Jong-Min
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.11-21
    • /
    • 1999
  • The capillary tube and short tube orifice have been widely used as an expansion device in the refrigeration and air-conditioning system. To improve the system performance, expansion devices need to be optimized with the components of a refrigeration system. In the present study, a numerical model for a capillary, which could predict the flow rate and properties along a tube, was developed by assuming homogeneous two-phase flow. A semi-empirical flow model for evaluation of the flow rate through a short tube orifice was also developed by using the experimental data. Finally, the results of the numerical model for a capillary was compared with those of the semi-empirical model for a short tube orifice to identify the dominant flow factors for the expansion devices.

  • PDF

모세관과 오리피스 팽창장치의 냉매유량 조절특성의 비교 (Comparison of refrigerant flow through capillary with short tube orifice)

  • 김용찬;최종민
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.118-128
    • /
    • 1998
  • Capillary and short tube orifice have been widely used as an expansion device in refrigeration and air-conditioning system. To improve the system performance, expansion devices need to be optimized with the components of a refrigeration system. In the present study, a numerical model for a capillary, which can predict properties along a tube and flow rate through a tube, was developed by assuming homogeneous two-phase flow, A semi-empirical flow model that can be used to evaluate the flow rate through a short tube orifice was also developed by summarizing the experimental data. Finally, the results of the numerical model for capillaries were compared with those of the semi-empirical model for short tube orifices to verify dominant flow factors for the expansion devices.

  • PDF

Experimental Study on Characteristics of Two-Phase Flow through a Bypass Orifice Expansion Device

  • Choi, Jong-Min;Kim, Yong-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권1호
    • /
    • pp.11-19
    • /
    • 2001
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which was a short tube haying a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them. and it would enhance the seasonal energy efficiency ratio of an inverter heat pump system, Based on experimental data, a semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model`s prediction was within $\pm$5%.

  • PDF

바이패스 오리피스 팽창장치의 유동 특성에 관한 실험적 연구 (Experimental study on characteristics of two-phase flow through a bypass-orifice expansion device)

  • 최종민;김용찬
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.109-116
    • /
    • 1999
  • To establish optimum cycle of the inverter-driven heat pump with a variation of frequency, the bypass orifice, which is a short tube having a bypass hole in the middle, was designed and tested. Flow characteristics of the bypass orifice were measured as a function of orifice geometry and operating conditions. Flow trends with respect to frequency were compared with those of short tube orifices and capillary tubes. Generally, the bypass orifice showed the best flow trends among them, that will enhance the seasonal energy efficiency ratio of an inverter heat pump system. Based on experimental data, the semi-empirical flow model was developed to predict mass flow rate through bypass orifices. The maximum difference between measured data and model's prediction was within ${\pm}5%$.

  • PDF

냉매 충전량과 팽창장치 변화에 따른 열펌프 시스템의 성능특성에 관한 연구 (The Performance of a Heat Pump with a Variation of Expansion Valve at Various Charging Conditions)

  • 최종민;김용찬
    • 설비공학논문집
    • /
    • 제15권8호
    • /
    • pp.661-666
    • /
    • 2003
  • Constant area expansion devices such as capillary tubes, short tube orifices are being gradually replaced with electronic expansion valves (EEVs) because of increasing focus on comfort and energy conservation. In this study, the performance of a water-to-water heat pump as a function of refrigerant charge is investigated in steady state, cooling mode operation with expansion devices of a capillary tube and an EEV. The performance of the capillary tube system varies drastically according to the change of refrigerant charge amount and inlet temperature of the secondary fluid in the condenser. Cooling capacity and COP of the EEV system show little dependence on the refrigerant charge, while those are strongly dependent on the secondary fluid temperature at the condenser inlet. In general, for a wide range of operating conditions the EEV system shows much higher performance as compared with the capillary tube system. The performance of the EEV system can be optimized by adjusting EEV opening to maintain a constant superheat at all test conditions.

An Empirical Correlation for Subcooled Two-Phase Critical Flow Rates in Short Tubes, Nozzles, and Orifices

  • Park, Choon-Kyung;Seok Cho;Won, Soon-Yeun;Min, Kyung-Ho;Chung, Moon-Ki
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.273-278
    • /
    • 1997
  • Critical two-phase flow rates of subcooled water through very short tube (L=20 mm) with small diameters (D=1.0 mm) has been measured for wide ranges of subcooling(0~186$^{\circ}C$) and pressure (0.5~2.0 MPa). Experimental results show that subcooled critical two-phase flow rates can be expressed in terms of two scaling parameters for geometries and initial conditions. They are discharge coefficient of cold water, ( $C_{d}$ )$_{ref}$, and dimensionless subcooling, $\Delta$ $T^{*}$$_{sub}$, respectively. A new empirical correlation expressed in terms of ( $C_{d}$ )$_{ref}$ and $\Delta$ $T^{*}$$_{sub}$ is obtained for subcooled two-phase flow rates through very short length tube. Comparisons between the mass fluxes calculated by Present correlation and a number of experimental data show that the agreement is very good.ood.ood.ood.

  • PDF