• 제목/요약/키워드: Shock wave.

검색결과 982건 처리시간 0.034초

가변형 음속 이젝터 유동에 관한 수치해석적 연구 (A Computational Study of a Variable Sonic Ejector Flow)

  • 이준희;최보규;김희동
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.526-531
    • /
    • 2003
  • A cone cylinder is used to obtain variable operation conditions of a sonic ejector-diffuser system. The cone cylinder is movable to change the ejector area ratio, thus obtaining variable mass flow rates. The present study investigates the effects of ejector throat area ratio and operating pressure ratio on the entrainment of secondary stream. The numerical simulations are based on a fully implicit finite volume scheme of the compressible, Reynolds-Averaged, Navier-Stokes equations. The ejector throat area is varied between 3.94 and 8.05, and the operating pressure ratio is changed from 3.0 to 9.0. The results show that the entrainment ratio and mass flux ratio become more dependent on the ejector throat area ratio, when the pressure operating ratio is low. The total pressure losses produced in the present ejector system increase with the operating pressure ratio and the ejector area ratio, but for a given operating pressure ratio, the losses are not significantly dependent on the ejector area ratio when it is larger than about 5.0.

  • PDF

신차단방식 SF$_{6}$ 가스 차단기의 소전류 차단성능 연구 (Investigation of Small Current Interruption Performance for New Type of Interrupting Chamber in SF$_{6}$ Gas Circuit Breaker)

  • 송원표;권기영;이재성;송기동;김맹헌;고희석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권11호
    • /
    • pp.519-526
    • /
    • 2005
  • This paper presents computer simulation results for developing new type of SF$_{6}$ Circuit Breaker in terms of cold gas flow after small current interruption. This cold gas flows down a nozzle into the chamber of a circuit breaker. There are many difficult problems in analyzing the gas flow due to complex geometry, moving boundary, shock wave and so on. When predicting the dielectric capability of a gas circuit breaker after interruption, the gas pressure and density distributions due to the cold gas must be considered in addition to the electrical field imposed across the gas. A self-coded computational fluid dynamics (CFD) program is used for the simulation of cold gas flow in order to evaluate the electrical field characteristic across open contacts and transient characteristics of insulations after small current interruption.

지능형 포탄의 저 감속 회수장치를 이용한 포탄의 감속방법 (Deceleration Method of Munition to used Soft Recovery System for Smart Munition)

  • 김명구;조종두;이승수;유일용;장쾌현
    • 한국소음진동공학회논문집
    • /
    • 제17권9호
    • /
    • pp.777-784
    • /
    • 2007
  • With the development of micro electronic circuits and optical equipment, the demand for developing smart munitions with the ability to autonomously search for and attack targets has increased. Since the electronic components within smart munitions are affected by high temperatures, pressure, and impulsive forces upon the combustion of gunpowder, stability and reliability need to be secured for them. Securing those stability and reliability requires soft recovery system which can decelerate smart munitions. A theoretical analysis of flow is performed for the secure recovery of bullets on the basis of Euler equation for compressible fluids. The inner pressure on a pressure tube, the speeds of bullets, and the deceleration of munitions are calculated theoretically. Theoretical results are compared with the data from the experiment with soft recovery system set up at the laboratory.

Numerical Simulation for the Rudder in order to Control the Cavitation Phenomena

  • Boo, Kyung-Tae;Song, In-Hang;Soochul Shin
    • Journal of Ship and Ocean Technology
    • /
    • 제8권1호
    • /
    • pp.42-50
    • /
    • 2004
  • In these ten years, the cavitation and erosion phenomena in the rudder have been increased for high-speed container ships. The cavitation in the rudder blades which is injurious to rudder efficiency is mainly caused by the main flow with a large angle of attack induced by propellers, and the erosion which occurs as a result of repeated blows by shock wave that cavitation collapse may produce was observed in the gap legion of the rudder. However, gap cavitation is not prone to occur in model experiments because of low Reynolds number. So, the viscous effect should be considered for solving the flow of the narrow gap. In order to predict the cavitation phenomena and to improve the performance of the rudder, the analysis of the viscous flow in the rudder gap is positively necessary. In this study, numerical calculation for the solution of the RANS equation is applied to the two-dimensional flow around the rudder gap including horn part and pintle part. The velocity and pressure field are numerically acquired according to Reynolds number and the case that the round bar is installed in the gap is analyzed. For reduced the acceleration that pressure drop can be highly restrained numerically and in model experiment, the cavitation bubbles can be reduced.

초음속 노즐에서 발생하는 비대칭 유동의 제어에 관한 연구 (Control of the Asymmetric Flow in a Supersonic Nozzle)

  • ;;;;;김희동
    • 한국가시화정보학회지
    • /
    • 제9권2호
    • /
    • pp.61-65
    • /
    • 2011
  • Several previous works on rocket nozzle flows have revealed the existence of the transition from FSS to RSS and the occurrence of asymmetric flow associated with the boundary layer separation, which can cause excessive side-loads of the propulsion system. Thus, it is of practical importance to investigate the asymmetric flow behaviors of the propulsion nozzle and to develop its control method. In the present study, the asymmetric flow control method using a cavity system was applied to supersonic nozzle flow. Time-dependent asymmetric flow was experimentally investigated with the rate of change of the nozzle pressure ratio. The results obtained showed that the cavity system installed on nozzle wall would be helpful in fixing the unsteady motions of the boundary layer separation, consequently reducing the possibility of the occurrence of the asymmetric flow.

점성 및 충격파 효과를 고려한 천음속 터빈 케스케이드의 유체유발 진동해석 (Flow-Induced Vibration of Transonic Turbine Cascades Considering Viscosity and Shock Wave Effects)

  • 오세원;김동현;박웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.793-802
    • /
    • 2006
  • In this study, a fluid/structure coupled analysis system for simulating complex flow-induced vibration (FIV) phenomenon of cascades has been developed. The flow is modeled using Euler and Wavier-Stokes equations with different turbulent models. The fluid domains are modeled using the unstructured grid system with dynamic deformations due to the motion of structural boundary. The Spalart-Allmaras (S-A) and the SST ${\kappa}-{\omega}$ turbulent models are used to predict the transonic turbulent flows. A fully implicit time marching scheme based on the Newmark direct integration method is used in order to solve the coupled governing equations for viscous flow-induced vibration phenomena. For the purpose of validation for the developed FIV analysis system, comparison results for computational analyses of steady and unsteady aerodynamics and flutter analyses are presented in the transonic flow region. In addition, flow-induced vibration analyses for the isolated cascade and multi-blades cascade models have been conducted to show the physical fluid-structure interaction effects in the time domain.

  • PDF

Virtual Flutter Plight Test of a Full Configuration Aircraft with Pylon/External Stores

  • Kim, Dong-Hyun;Kwon, Hyuk-Jun;Lee, In;Paek, Seung-Kil
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제4권1호
    • /
    • pp.34-44
    • /
    • 2003
  • An advanced aeroelastic analysis using a computational structural dynamics (CSD), finite element method (FEM) and computational fluid dynamics (CFD) is presented in this Paper. A general aeroelastic analysis system is originally developed and applied to realistic design problems in the transonic flow region, where strong shock wave interactions exist. The present computational approach is based on the modal-based coupled nonlinear analysis with the matched-point concept and adopts the high-speed parallel processing technique on the low-cost network based PC-clustered machines. It can give very accurate and useful engineering data on the structural dynamic design of advanced flight vehicles. For the nonlinear unsteady aerodynamics in high transonic flow region, Euler equations using the unstructured grid system have been applied to easily consider complex configurations. It is typically shown that the advanced numerical approach can give very realistic and practical results for design engineers and safe flight tests. One can find that the present study conducts a virtual flutter flight test which are usually very dangerous in reality.

초고압 $SF_6$ 가스차단기의 소전류 차단성능 해석기술 I (Evaluation Method I of the Small Current Breaking Performance for SF(sub)6-Blown High-Voltage Gas Circuit Breakers)

  • 송기동;이병운;박경엽;박정후
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권7호
    • /
    • pp.331-337
    • /
    • 2001
  • With the increasing reliability of analysis schemes and the dramatically increased calculating speed, the computer simulation has become and indispensable process to predict the interruption capacity of circuit breakers. Generally, circuit breakers have to possess both the small current and large current interruption abilities and the circuit breaker designers need to evaluate its capacities to save the time and the expense. The analysis of small current and the large current interruption performances have been considered separately because the phenomena occurring in a interrupter are quite different. To analyze the dielectric recovery after large current interruption many physical phenomena such as heat transfer, convection and arc radiation, the nozzle ablation, the ionization of high temperature SF(sub)6 gas, the electric and themagnetic forces and so forth mush be considered. However, in the analysis of small current interruption performance only the cold gas flow analysis needs to be carried out because the capacitive current is to small that the influence from the current can be neglected. In this paper, an empirical equation which is obtained from a series of tests to estimate the dielectric recovery strength has been applied to a real circuit breaker. The results of analysis have been compared with the test results and the reliability has been investigated.

  • PDF

펄스파워 기술을 이용한 방전파쇄과정의 전압파형 검출 (Voltage waveform detection of discharge breaking process used pulsed-power technique)

  • 정영환;윤성호;이유수;이동훈;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2195-2197
    • /
    • 1999
  • Electric breakdown in the liquid produces a spark channel. The energy input into the channel causes expansion of a vapor gas cavity. If the power of the discharge is high enough, this expansion is fast enough to produce a shock wave which propagates through the liquid to the subject of destruction. We focused our attention on the correlation between electric parameters and the characteristics of the flash caused by point to-point electrode discharge in the water. By varying firing voltage and gap length, we obtained the features of the flash : amplitude, pulse width, and so on. In this paper, We have known that there is a concrete interrelation between underwater firing voltage and photodiode output.

  • PDF

2차원 직선 정지 익렬에서의 비점성 천이음속유동에 관한 수치적 해석 (Numerical Analysis of 2D, Steady, Inviscid Transonic Flow Through Stationary Compressor Cascade)

  • 최인환;이진호;조강래
    • 대한기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.1244-1253
    • /
    • 1990
  • 본 연구에서는 Denton이 제시한 개선된 시간진행법을 이용하여 2차원 직선 정 지 익렬의 유동해석 프로그램의 개발을 목적으로 하고 있으며 기존 프로그램의 안정성 과 수렴의 개선에 역점을 두고 진행하였다. 수치계산 결과는 타당성을 입증하기 위 하여 실험결과 및 Braembussche의 특이점법 수치계산 결과와 비교 검토 하였으며 충격 파가 존재하는 천이음속의 유동에 대하여 수치계산을 실시하였다.