• Title/Summary/Keyword: Shock pulse

Search Result 107, Processing Time 0.026 seconds

Sonoluminescence Characteristics from Submicron Size bubbles (마이크로 이하 기포로부터의 소노루미네센스 특성)

  • Byun, Ki-Taek;Karng, Sarng-Woo;Kim, Ki-Young;kwak, Ho-Young
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1201-1206
    • /
    • 2004
  • Sonoluminescence (SL) characteristics such as pulse shape, radiance and spectrum radiance from submicron bubbles were investigated. In this study, a set of analytical solutions of the Navier-Stokes equations for the gas inside bubble and equations obtained from mass, momentum and energy equations for the liquid layer adjacent the bubble wall were used to estimate the gas temperature and pressure at the collapse point, which are crucial parameters to determine the SL characteristics. Heat transfer inside the gas bubble as well as at the liquid boundary layer, which was not considered in the most of previous studies on the sonoluminescence was taken it into account in the calculation of the temperature distribution inside the bubble. It was found that bremsstrahlung is a very possible mechanism of the light emission from either micron or submicron bubbles. It was also found that the peak temperature exceeding $10^{6}$ K in the submicron bubble driven at 1 MHz and 4 atm may be due to the rapid change of the bubble wall acceleration near the collapse point rather than shock formation.

  • PDF

The Current Evaluation State of Post-Anesthetic Recovery after General Anesthesia (전신마취 후 회복 평가도구 활용 실태)

  • Lee, Hwa In
    • Korean Journal of Adult Nursing
    • /
    • v.18 no.5
    • /
    • pp.691-698
    • /
    • 2006
  • Purpose: This research was conducted to evaluate, analyze, and determine the limitation of the anesthesia that is used in there covery room in order to provide the foundation for developing the effectiveness of it. Method: There covery records of this study were collected from 41 hospitals in Seoul, Kyung Kii-Do, and Inchon province. The post anesthetic recovery records consisted of the evaluation of type, evaluative items, frequency, time, score and $SaO_2$. These records were collected from September to December of 2005. Results: The most commonly used post anesthetic evaluation tool was Alderete Score, which was used in 73% of hospitals. The second was Aldrete Score with $SaO_2$(17%). Also, 5% of the hospitals used the modified AS form. There were 2.5% of the hospitals applying the adult and child in the evaluation separately. Also, the last 2.5% of the hospitals did not use AS but measured BP, pulse, respiration, temperature, and $SaO_2$ with observing nausea, vomiting, urinary retention, backache, laryngitis, shock, and neurologic assessment. Conclusion: It is necessary to develop a post-anesthetic recovery evaluation tool including the application of $SaO_2$, so that the early-diagnosis of hypoxia can be possible. In addition, it is necessary to develop a post- anesthetic recovery evaluating method that can distinguish a difference between adults and children.

  • PDF

Effect of imipramine or ECS on central $\beta_1$and $\beta_2$receptor Sensitivity in the Cardiovascular Response of Rat

  • Sohn, Uy-Dong;Kim, Choong-Young;Huh, In-Hoi
    • Archives of Pharmacal Research
    • /
    • v.12 no.4
    • /
    • pp.282-288
    • /
    • 1989
  • This study was investigated the effects of imipramine (IMI) and electroconvulsive shock (ECS), which are used as antidepressant therapy, on the central $\beta_1$or $\beta_2$ adrenergic receptor in anesthetized rats. The resting blood pressure and heart rate decreased in reserpinized group (5 mg/kg i. p., 24 hr before), but not in order 4 groups i. e. acute IMI (20 mg/kg i. p.. 3-5 hr before), chronic IMI (Same dose, twice a day for 14 days), siggle ECS (sinusoidal 20 Hz, 120 V for 2 sec) and repeated ECS (same condition, daily for 12 days). The increase of heart rate and hypotension evoked by 1 or 3 $\mu$g intracerebroventricular (i. c. v.) administration of (+) dobutamine, $\beta_2$-agonist, 1 or 3 $\mu$g i. c. v. was significantly attenuated in repeated ECS or reserpine treatment. And, the diminuation of pulse pressure of salbutamol also reduced by repeated ECS. These results suggest that IMI or ECS result in attenuation on tachycardia by (+) dobutamine or on hypotension by salbutamol, presumably by which the central $\beta_1$ or $\beta_2$receptor sensitivity may be suppressed, repectively.

  • PDF

The Efficiency of a Spring Mass Dampers System for the Control of Vibrations and Structure-borne Noise (진동 및 고체음 제어를 위한 스프링 매스댐퍼계의 효과)

  • ;;;;Heiland, D.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.04a
    • /
    • pp.147-147
    • /
    • 1993
  • All types of dynamic excitation, periodical, pulse or transient in vertical, horizontal or all three directions can be effectively reduced by vibration isolation systems. Typical elements for vibration isolation control are spring units consisting of a group of helical compression springs. In all cases of shock, transient or random excitation energy absorbing dampers have to be added to the spring units in order to reduce system response in the frequency range near the natural frequency of the isolation system. The same isolation system of spring units and viscos-dampers has been used since 1979 for passive protection of buildings and structures has been proved to by very advantageous for vibration and structure borne noise control. Not only because of high vertical flexibility of the spring units, compared for example with typical rubber or neoprene mounts out also because of the horizontal of flexibility, which can be adapted by modifying the spring dimensions to nearly every requirement. It is just normal to use the same basic elements for passive isolation as for active isolation.

  • PDF

Preparation of LaGaO3 Based Oxide Thin Film on Porous Ni-Fe Metal Substrate and its SOFC Application

  • Ju, Young-Wan;Matsumoto, Hiroshige;Ishihara, Tatsumi;Inagaki, Toru;Eto, Hiroyuki
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.12
    • /
    • pp.796-801
    • /
    • 2008
  • $LaGaO_3$ thin film was prepared on Ni-Fe metal porous substrate by Pulsed Laser Deposition method. By the thermal reduction, the dense $NiO-{Fe_3}{O_4}$ substrate is changed to a porous Ni-Fe metal substrate. The volumetric shrinkage and porosity of the substrate are controlled by the reduction temperature. It was found that a thermal expansion property of the Ni-Fe porous metal substrate is almost the same with that of $LaGaO_3$ based oxide. $LaGaO_3$ based electrolyte films are prepared by the pulsed laser deposition (PLD) method. The film composition is sensitively affected by the deposition temperature. The obtained film is amorphous state after deposition. After post annealing at 1073K in air, the single phase of $LaGaO_3$ perovskite was obtained. Since the thermal expansion coefficient of the film is almost the same with that of LSGM film, the obtained metal support LSGM film cell shows the high tolerance against a thermal shock and after 6 min startup from room temperature, the cell shows the almost theoretical open circuit potential.

Voltage waveform detection of discharge breaking process used pulsed-power technique (펄스파워 기술을 이용한 방전파쇄과정의 전압파형 검출)

  • Chung, Y.H.;Yoon, S.H.;Lee, Y.S.;Lee, D.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2195-2197
    • /
    • 1999
  • Electric breakdown in the liquid produces a spark channel. The energy input into the channel causes expansion of a vapor gas cavity. If the power of the discharge is high enough, this expansion is fast enough to produce a shock wave which propagates through the liquid to the subject of destruction. We focused our attention on the correlation between electric parameters and the characteristics of the flash caused by point to-point electrode discharge in the water. By varying firing voltage and gap length, we obtained the features of the flash : amplitude, pulse width, and so on. In this paper, We have known that there is a concrete interrelation between underwater firing voltage and photodiode output.

  • PDF

Tearing of metallic sandwich panels subjected to air shock loading

  • Zhu, Feng;Lu, Guoxing;Ruan, Dong;Shu, Dong-Wei
    • Structural Engineering and Mechanics
    • /
    • v.32 no.2
    • /
    • pp.351-370
    • /
    • 2009
  • This paper presents a computational study for the structural response of blast loaded metallic sandwich panels, with the emphasis placed on their failure behaviours. The fully-clamped panels are square, and the honeycomb core and skins are made of the same aluminium alloy. A material model considering strain and strain rate hardening effects is used and the blast load is idealised as either a uniform or localised pressure over a short duration. The deformation/failure procedure and modes of the sandwich panels are identified and analysed. In the uniform loading condition, the effect of core density and face-sheets thicknesses is analysed. Likewise, the influence of pulse shape on the failure modes is investigated by deriving a pressure-impulse (P-I) diagram. For localised loading, a comparative study is carried out to assess the blast resistant behaviours of three types of structures: sandwich panel with honeycomb core, two face-sheets with air core and monolithic plate, in terms of their permanent deflections and damage degrees. The finding of this research provides a valuable insight into the engineering design of sandwich constructions against air blast loads.

Factors Influencing on Prehospital Emergency Nurses' Activities and Procedures in the Field (병원 전 응급간호사의 응급 처치 수행 능력과 영향 요인)

  • Kim, Bog-Ja;Kang, Kyung-Hee;Lim, Yong-Su
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.15 no.1
    • /
    • pp.64-71
    • /
    • 2009
  • Purpose: This study shows the prehospital emergency nursing practices, and analyzes them associated with their individual characteristics and job conditions. Method: Based on a survey of the National Emergency Medical Center in Korea(2008), principal components were extracted from 7 prehospital emergency nursing practices by factor analysis, and some regression analyses of principal components(CPR-AED and V/S-I.V.) were executed on individual characteristics and job conditions. Results: The PENs gave themselves higher order ratings for vital sign check, airway management for loss of consciousness patients, CPR for suspicious cardiac arrest, keeping vein open for shock patients, AED for abnormal pulse rate, AED for suspicious cardiac arrest, and AED for loss of consciousness. Age and duty periods were statistically significant influential factors on the CPR-AED component. Conclusion: The results indicate that the PENs were competent in overall prehospital emergency activities and procedures even some weak self-evaluations, and that the standard curriculum and practice standard for prehospital nursing should be developed in order to increase nursing leadership in prehospital emergency settings.

  • PDF

A Prototype Development of Personal Low-frequency Stimulator with Characteristic Analysis (개인용 저주파 자극기의 특성분석 및 Prototype개발)

  • Lee, Gi-Song;Lee, Dong-Ha;Yu, Jae-Taek
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.349-352
    • /
    • 2003
  • A personal low-frequency stimulator is a portable device to relax muscle pains of a person. The stimulator generates combined low-frequency pulses to be applied to pads attached to painful muscles. This paper reports a development of such device with its characteristic analyses. The major components of our stimulator are MCU, high-voltage generating circuit part, high-voltage switching circuit part, input switch part and display unit. High-voltage generating circuit is designed by using a boost converter circuit and allows user control of the output voltage. High-voltage switching circuit, controlled by MCU, generates output voltage to be applied to pads. Input switch part is composed of power supply, intensity selection, mode selection and memory. Display unit adopts a text LCD module to display modes, Intensity, output frequency and user set-up time. Our designed safety circuit, to protect human body from possible electric shock, slowly increases the output voltage to the selected output intensity. It continuously checks the output pulse shape and disable the output when dangerous pulses are detected. This paper also shows some experimental results.

  • PDF

New Drug Delivery System Based on a Laser-Induced Shockwave (레이저 유도 충격파를 이용한 첨단 약물전달시스템 개발)

  • Han, Tae-Hee;Lee, Hyun-Hee;Gojani, Ardian B.;Yoh, Jai-Ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • Impingement of a high power laser pulse (above 1 GW/$cm^2$) on a metal foil causes its ablation, which is characterized by a rapid expulsion of matter and the initiation of a strong shock wave inside the solid metal. The shock propagates through the foil and reverberates on the rear side, causing its deformation and microparticle ejection, which were deposited on the foil prior to ablation. Based on this principle, we are developing a new drug delivery system - Biolistic gun. Current study is focused on the controllability, stability, efficiency of the system, and characterization of the penetration shapes in various conditions. We have tested the system by applying direct and confined ablation. Several different media combinations were used for confinement-BK7 glass, water, BK7 glass with water, and succulent jelly(ultrasono jelly, RHAPAPHRM). Biological tissue was replicated by a 3% gelatin solution. Present data shows that the confinement results in enhancement of penetration shape reached by 5 um cobalt microparticles. Based on the analysis of the experimental results we observe that the penetration shape of microparticles can be controlled by adjusting the thickness of confinement media.