• Title/Summary/Keyword: Shift rotating system

Search Result 23, Processing Time 0.015 seconds

Positioning-error Analysis of Vibration Sensors for Prognostics and Health Management in Rotating System (갠트리 크레인 호이스트의 건전성 평가를 위한 진동 모사시스템 구축과 데이터 통계 분석)

  • Jang, Jaewon;Han, Zhiqiang;Zhang, Haiyang;Oh, Daekyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.346-353
    • /
    • 2022
  • Recently, studies on the integrity of rotating machines, such as gantry cranes, which are used in the shipbuilding industry, have been actively conducted. Gantry cranes are driven at relatively low revolutions per minute (RPM), are frequently operated and stopped, and are impacted by external environmental factors, such as shock and noise in the measurement data. The purpose of this study was to construct a replica of a gantry crane hoist used in indoor shipbuilding and analyze the acquired data for errors caused by the shift in operating conditions (RPM) and the change in the position of the data acquisition sensor. Consequently, we observed that the error caused by differences in sensor positions did not occur significantly under low operating conditions but occurred significantly under relatively high operating conditions. Thus, we determined that both the operating condition and position of the acquisition sensor affected the data acquired by the rotary machine.

Roundabout Design and Intervehicle Distance Measure for V2X-based Autonomous Driving (V2X 기반 자율운전을 위한 회전교차로 설계 및 차간 거리 측정)

  • Hwang, Jae-Jeong;Oh, Seok-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.6
    • /
    • pp.83-89
    • /
    • 2021
  • To improve the performance of self-driving cars, the introduction of V2X, a communication technology that connects vehicles, infrastructure, and vehicles, is essential. Even if traffic information of the other vehicle is known, the structure of the intersection and a distance calculation algorithm are required for accurate calculations at roundabouts. This paper proposes a design algorithm for a rotating intersection and implemented in Matlab that complies with the national design rules and enables accurate calculations. Assuming the roundabout and the entrance/exit path to be a circle, a method for measuring the distance between vehicles at an arbitrary point was proposed using the horizontal shift of the entrance circle to the main circle. The algorithm could be used in fully autonomous vehicles by designing a roundabout suitable for the terrain by arbitrarily varying the angle between branches and the radius of curvature of the entrance and exit roads, and transmitting a warning signal when a collision between two driving vehicles is expected.

A of Radiation Field with a Developed EPID

  • Y.H. Ji;Lee, D.H.;Lee, D.H.;Y.K. Oh;Kim, Y.J.;C.K. Cho;Kim, M.S.;H.J. Yoo;K.M. Yang
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.67-67
    • /
    • 2003
  • It is crucial to minimize setup errors of a cancer treatment machine using a high energy and to perform precise radiation therapy. Usually, port film has been used for verifying errors. The Korea Cancer Center Hospital (KCCH) has manufactured digital electronic portal imaging device (EPID) system to verify treatment machine errors as a Quality Assurance (Q.A) tool. This EPID was consisted of a metal/fluorescent screen, 45$^{\circ}$ mirror, a camera and an image grabber and could display the portal image with near real time KIRAMS has also made the acrylic phantom that has lead line of 1mm width for ligh/radiation field congruence verification and reference points phantom for using as an isocenter on portal image. We acquired portal images of 10$\times$10cm field size with this phantom by EPID and portal film rotating treatment head by 0.3$^{\circ}$, 0.6$^{\circ}$ and 0.9$^{\circ}$. To check field size, we acquired portal images with 18$\times$18cm, 19$\times$19cm and 20$\times$20cm field size with collimator angle 0$^{\circ}$ and 0.5$^{\circ}$ individually. We have performed Flatness comparison by displaying the line intensity from EPID and film images. The 0.6$^{\circ}$ shift of collimator angle was easily observed by edge detection of irradiated field size on EPID image. To the extent of one pixel (0.76mm) difference could be detected. We also have measured field size by finding optimal threshold value, finding isocenter, finding field edge and gauging distance between isocenter and edge. This EPID system could be used as a Q.A tool for checking field size, light/radiation congruence and flatness with a developed video based EPID.

  • PDF