• Title/Summary/Keyword: Shielding simulation

Search Result 238, Processing Time 0.02 seconds

Evaluation of RF shielding materials to improve MR image of hybrid PET/MRI

  • Hyun Keong Lim;Yong Choi;Jin Ho Jung;Jiwoong Jung;Changheun Oh;Hyun-wook Park;Jong Guk Kim
    • Journal of the Korean Physical Society
    • /
    • v.80
    • /
    • pp.640-646
    • /
    • 2022
  • Hybrid PET/MRI is a useful imaging system that can improve diagnostic accuracy by providing both functional and anatomical information. However, the combination of PET and MRI can lead to mutual interference, which can degrade the performances of both imaging systems. One of the methods that is capable of preserving the performance of both modalities is to apply RF shielding to PET detectors and electronics. The purpose of this study was to propose a new RF shielding method using Au-plated conductive fabric (PCF) tape that could not only minimize RF interference and eddy current, but that could also be applied to complex PET gantry and detector module structures more easily than thin Cu foils, which have been widely used as a shielding material for hybrid PET/MRI systems. To evaluate the performance of the proposed new RF shielding method, the effects of the two RF shield materials (Cu and Au) on the B1 + field generated by the RF head coil were estimated using a computer simulation method. The effects of the Au PCF tape and Cu foil on the homogeneity and SNR of the MR image were also experimentally evaluated using a commercial 3-T MRI. The uniformity of the B1 + field map was slightly decreased by the use of Cu and Au RF shields. The deterioration in the MR image quality caused by the Au PCF tape was less than that caused by Cu foil. The simulation and experimental results indicate that Au PCF tape can serve as an alternative shielding material that reduces RF interference and eddy current for hybrid PET/MRI systems.

Comparison of nano/micro lead, bismuth and tungsten on the gamma shielding properties of the flexible composites against photon in wide energy range (40 keV-662 keV)

  • Asgari, Mansour;Afarideh, Hossein;Ghafoorifard, Hassan;Amirabadi, Eskandar Asadi
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4142-4149
    • /
    • 2021
  • In the radiation protection application, the metal-polymer composites have been developed for their radiation shielding properties. In this research, the elastomer composites doped by 10 ㎛ and 100nm size of lead, bismuth and tungsten particles as filler with 30 and 60 wt percentages were prepared. To survey the shielding properties of the polymer composites using gamma-ray emitted from 152Eu and 137Cs sources, the gamma flux was measured by using NaI(Tl) detector, then the linear attenuation coefficient was calculated. Also, the Monte Carlo simulation (MCs) method was used. The results showed a direct relationship between the linear attenuation coefficients of the absorbent and filler ratio. Also, the decrease in the particle size of the shielding material in each weight percentage improved the radiation shielding features. When the dimension of the particles was in the order of nano-size, more attenuation was achieved. At low energies used for medical diagnostic X-ray applications due to the predominance of the photoelectric effect, bismuth and lead were suitable selection as filler.

Gamma ray exposure buildup factor and shielding features for some binary alloys using MCNP-5 simulation code

  • Rammah, Y.S.;Mahmoud, K.A.;Mohammed, Faras Q.;Sayyed, M.I.;Tashlykov, O.L.;El-Mallawany, R.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2661-2668
    • /
    • 2021
  • Gamma radiation shielding features for three series of binary alloys identified as (Pb-Sn), (Pb-Zn), and (Zn-Sn) have been investigated. The mass attenuation coefficients (µ/ρ) for the selected alloys were simulated using the MCNP-5 code in the energy range between 0.01 and 15 MeV. Moreover, the (µ/ρ) values were computed using WinXCOM database in the same energy range to validate the simulation results. Results reveal a good agreement between the simulated and computed values. The half value layer (HVL), mean free path (MFP), effective atomic number (Zeff) and exposure buildup factor (EBF) were evaluated for the selected binary alloys. Results showed that the PS1, PZ1, and ZS2 alloys have the best shielding parameters and better than the commercially standard and available radiation shielding materials. Therefore, the investigated alloys can be used as effective radiation shielding materials against gamma ray with energies between 0.01 and 15 MeV.

Characteristics simulation of wireless power transfer system considering shielding distance

  • Lee, Yu-Kyeong;Choi, Hyo-Sang;Jung, Byung Ik;Jeong, In-Sung
    • Progress in Superconductivity and Cryogenics
    • /
    • v.17 no.1
    • /
    • pp.40-43
    • /
    • 2015
  • Wireless power transfer technology is using the magnetic resonance recently drawing increased attention. It uses the resonance between transmitter and receiver coils to transfer power. Thus, it can improve the transfer distance and efficiency compared with the existing magnetic induction technique. The authors found from the previous study that the application of the superconductor coil to the magnetic resonance wireless power transfer system improved its efficiency. Its application to real life, however, requires the additional study on the effects of adjacent materials. In this study, the two resonance coils made by superconductor coils were used to aluminum and plastic shielding materials was placed between the coils. S-parameters were analyzed according to the position of the shielding material between the transmitter and receiver coils. As a result, the plastic of shielding material had no effect, but the aluminum of shielding material affected the wireless power transfer due to the shielding effectiveness.

Comparison of Striking Distance Formulae and Their Effect on Lightning Shielding Analysis (뇌 차폐 해석에서 뇌격흡인 거리 수식과 영향 비교)

  • Kim, Sung-Sam
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.694-699
    • /
    • 2011
  • This paper compares the performance of lightning shielding analysis methods using the seven striking distance formulae in substation. For comparison, we evaluate the number of expected strikes and exposed area using WinIGS Software. Seven striking distance formulae are compared using the electrogeometric model analysis and the rolling sphere method. Based on the electrogeometric model analysis, the risk of shielding failure in either the whole substation or parts of it is determined. According to the simulation results, one can justify whether the substation satisfies the criterion of shielding design. In particular, according to the rolling sphere method, the exposed areas in substation determine the location of the additional shielding poles or shield wires. Therefore, the installation of the additional shielding poles and shield wires in substation was accepted by shield design at the phase conductors exposed in the larger area.

Performance Evaluation of Gamma ray Shielding of Antimony Shielding Sheet (안티몬 차폐시트의 감마선 차폐 성능평가)

  • Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.135-140
    • /
    • 2018
  • In this study, the dose of antimony shielding sheet was measured and the shielding rates according to the distance between the radioisotopes and the detector was analyzed according to the type of $^{99m}Tc$, $^{18}F$, $^{201}Tl$, $^{131}I$, $^{123}I$ using the antimony shielding sheet. The detector was used with an inspector. Six sheets of 0.25 mmPb were prepared with 20 cm width and length. Measurement results using $^{99m}Tc$, $^{201}Tl$, and $^{123}I$ showed that as the thickness of the sheet became thicker, the farther the distance from the source to the sheet was, the smaller the transmitted dose amount was measured. It was analyzed that a thickness of 1.50 mm or more was required to obtain a shielding rates of 90% or more. In the experiments of $^{18}F$ and $^{131}I$, the dose value was highest when 0.25 mm sheet was used, and the shielding rates was negative, unlike the results of other radioisotopes. Since $^{201}Tl$ are used when using antimony sheet and $^{18}F$ and $^{131}I$ have no shielding effect, it is thought that it is effective to reduce dose by repeating training and simulation training so that work can be done in a short time.

Study on the shielding performance of bismuth oxide as a spent fuel dry storage container based on Monte Carlo simulation

  • Guo-Qiang Zeng;Shuang Qi;Peng Cheng;Sheng Lv;Fei Li;Xiao-Bo Wang;Bing-Hai Li;Qing-Ao Qin
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.3307-3314
    • /
    • 2024
  • For traditional spent fuel shielding materials, due to physical and chemical defects and cost constraints, they have been unable to meet the needs. Therefore, this paper carries out the first discussion on the application and performance of bismuth in neutron shielding by establishing Monte Carlo simulation on the neutron flux model of shielded spent fuel. Firstly, functional fillers such as bismuth oxide, lead oxide, boron oxide, gadolinium oxide and tungsten oxide are added to the matrices to compare the shielding rates of aluminum alloy matrix and silicone rubber matrix. The shielding rate of silicone rubber mixture is higher than aluminum alloy mixture, reaching more than 56%. The optimal addition proportion of bismuth oxide and lead oxide is 30%, and the neutron radiation protection efficiency reaches 60%. Then, the mass attenuation coefficients of bismuth oxide, lead oxide, boron oxide, gadolinium oxide and tungsten oxide in silicone rubber matrix are simulated with the change of functional fillers proportion and neutron energy. This simulation result shows that the mixture with functional fillers has good shielding performance for low energy neutrons, but poor shielding effect for high energy neutrons. Finally, in order to further evaluate the possibility of replacing lead oxide with bismuth oxide as shielding material, the half-value layers and various properties of bismuth oxide and lead oxide are compared. The results show that the shielding properties of bismuth oxide and lead oxide are basically the same, and the mechanical properties, heat resistance, radiation resistance and environmental protection of bismuth oxide are better than that of lead oxide. Therefore, in the case of neutron source strengths in the range of 0.01-6 MeV and secondary gamma rays produced below 2.5 MeV, bismuth can replace lead in neutron shielding applications.

Analysis of Shielding Effectiveness of Low Conductivity Shield Layers within Near-field Region (근거리장에 놓인 저전도율 차폐막의 차폐 효과 분석)

  • Lee, Won-Seon;Lee, Won-Hui;Hur, Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.59-65
    • /
    • 2019
  • The EMI shielding effectiveness of shielding layers thickness was analyzed when the low conductivity shielding layers was placed in the near field of the noise source. A spiral antenna with broadband characteristics was used as the noise source, and graphite was selected as the low conductivity shielding material. Two spiral antennas were constructed to analyze the transmission coefficient between two antennas, and the distances between the transmitting and receiving antennas were 5 cm and 10 cm. The thickness of the shielding layers was changed from 1 um to 200 um. The frequency was changed from 100 MHz to 6 GHz to obtain a maximum SE(Shielding Effectiveness) of 70 dB. In this simulation, electronic shielding was used due to the nature of graphite, which is a shielding film material. Based on these results, we will study how to improve the shielding performance by implementing magnetic shielding in the future.

MIGSHIELD: A new model-based interactive point kernel gamma ray shielding package for virtual environment

  • Li, Mengkun;Xu, Zhihui;Li, Wei;Yang, Jun;Yang, Ming;Lu, Hongxin;Dai, Xinyu
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1557-1564
    • /
    • 2020
  • In this paper, 3D model-based interactive gamma ray shielding package (MIGSHIELD) is developed in virtual reality platform for windows operating system. In MIGSHIELD, the computational methodology is based on point kernel algorithm (PK), several key parameters of PK are obtained using new technique and new methods. MIGSHIELD has interactive capability with virtual world. The main features made in the MIGSHIELD are (i) handling of physical information from virtual world, (ii) handling of arbitrary shapes radioactive source, (iii) calculating the mean free path of gamma ray, (iv) providing interactive function between PK and virtual world, (v) making better use of PK for virtual simulation, (vi) plug and play. The developed package will be of immense use for calculations involving radiation dose assessment in nuclear safety and contributing to fast radiation simulation for virtual nuclear facilities.

Low Resistance SC-SJ(Shielding Connected-Super Junction) 4H-SiC UMOSFET with 3.3kV Breakdown Voltage (3.3kV 항복 전압을 갖는 저저항 SC-SJ(Shielding Connected-Super Junction) 4H-SiC UMOSFET)

  • Kim, Jung-hun;Kim, Kwang-Soo
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.756-761
    • /
    • 2019
  • In this paper, we propose SC-SJ(Shielding Connected-Super Junction) UMOSFET structure in which p-pillars of conventional 4H-SiC Super Junction UMOSFET structures are placed under the shielding region of UMOSFET. In the case of the proposed SC-SJ UMOSFET, the p-pillar and the shielding region are coexisted so that no breakdown by the electric field occurs in the oxide film, which enables the doping concentration of the pillar to be increased. As a result, the on-resistance is lowered to improve the static characteristics of the device. Through the Sentaurus TCAD simulation, the static characteristics of proposed structure and conventional structure were compared and analyzed. The SC-SJ UMOSFET achieves a 50% reduction in on-resistance compared to the conventional structure without any change in the breakdown voltage.