• Title/Summary/Keyword: Shielding efficiency

Search Result 183, Processing Time 0.022 seconds

A Comparative Study of the Shielding Performance of Uniforms using Electromagnetic Wave Shielding Materials Currently on the Market for Workers at Korea Railroad Corporation (전자파 고노출 직업군의 근무환경 조사 및 시판 전자기파 차폐소재를 이용한 철도 근무복의 차폐성능 연구)

  • Jung, Hee-Jung;Choi, Hei-Sun;Kim, Eun-Kyong
    • Journal of the Korean Society of Costume
    • /
    • v.60 no.6
    • /
    • pp.23-36
    • /
    • 2010
  • This study set out to develop clothes made of electromagnetic wave shielding materials. Among the various worker groups exposed to electromagnetic waves for long hours, railroad workers were chosen for the study. After selecting the locations they worked, the investigator measured electromagnetic wave on the field. To examine the effects of electromagnetic wave shielding materials, I applied a lining made of electromagnetic wave shielding materials to the existing work clothes. The first experimental clothes had the silver fabric for the lining in the current working clothes, the second experimental clothes had the copper- and nickel-plate polyester placed between the outer and the lining to prevent the corrosive material from contacting the skin, and the third experimental clothes had the silver fabric for the lining and the copper- and nickel-plate polyester between the outer and the lining. The results indicate that even if a fabric is evaluated to shield electromagnetic waves after tests, it cannot completely shield electromagnetic waves emitting from everyday appliances of 60Hz. Therefore, there should be ongoing development and research efforts on fabrics that can shield electromagnetic waves to a certain degree in order to develop working clothes to alleviate fatigue for those who are constantly exposed to electromagnetic waves, relieve their anxiety, offer them psychological stability and thus help them increase job efficiency.

Electromagnetic Wave Shielding Effect of Nano-powder Dispersed Epoxy Resin Composite (나노분말이 분산된 에폭시 섬유수지의 전자파차폐 효과)

  • Han, Jun-Young;Lee, Chul-Hee;Choi, Min-Gyu;Hong, Soon-Jik;Park, Joong-Hark;Lee, Dong-Jin
    • Journal of Powder Materials
    • /
    • v.22 no.4
    • /
    • pp.234-239
    • /
    • 2015
  • Electronic products are a major part of evolving industry and human life style; however most of them are known to emit electromagnetic waves that have severe health hazards. Therefore, different materials and fabrication techniques are understudy to control or limit transfer of such waves to human body. In this study, nanocomposite powder is dispersed into epoxy resin and shielding effects such as absorption, reflection, penetration and multiple reflections are investigated. In addition, nano size powder (Ni, $Fe_2O_3$, Fe-85Ni, C-Ni) is fabricated by pulsed wire evaporation method and dispersed manually into epoxy. Characterization techniques such as X-ray diffraction, Scanning electron microscopy and Transmission electron microscopy are used to investigate the phase analysis, size and shape as well as dispersion trend of a nano powder on epoxy matrix. Shielding effect is measured by standard test method to investigate the electromagnetic shielding effectiveness of planar materials, ASTM D4935. At lower frequency, sample consisting nano-powder of Fe-85%Wt Ni shows better electromagnetic shielding effect compared to only epoxy, only Ni, $Fe_2O_3$ and C-Ni samples.

Electromagnetic Interference Shielding Characteristics of Electroless Nickel Plated Carbon Nanotubes (무전해 니켈 도금된 탄소나노튜브의 전자파 차폐 특성)

  • Kim, Do Young;Yun, Kug Jin;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.25 no.3
    • /
    • pp.268-273
    • /
    • 2014
  • In this study, multi-walled carbon nanotubes (MWCNT) were treated with nickel by electroless plating method for improving electromagnetic interference (EMI) shielding performance of MWCNT. The physical properties of electroless plated MWCNT were analyzed by using ultra-high resolution scanning electron microscope (UHR-SEM), thermogravimetry (TGA), sheet resistance analyzer and EMI shielding analyzer. EMI shielding efficiencies of nickel electroless plated MWCNT were measured to be 16 dB from 800 MHz band, which was 1.6 times increased compared to that of the activated MWCNT. Also, the average sheet resistance of nickel electroless plated MWCNT was measured to be $70{\Omega}/sq$, which was 56% decreased compared to that of the activated MWCNT. This result could be attributed to the plating morphology on the surface of MWCNT. This result could be attributed to uniformity of plating morphology on the surface, which has more effect on EMI shielding efficiency than the amount of nickel plating.

Polybenzimidazole (PBI) Coated CFRP Composite as a Front Bumper Shield for Hypervelocity Impact Resistance in Low Earth Orbit (LEO) Environment

  • Kumar, Sarath Kumar Sathish;Ankem, Venkat Akhil;Kim, YunHo;Choi, Chunghyeon;Kim, Chun-Gon
    • Composites Research
    • /
    • v.31 no.3
    • /
    • pp.83-87
    • /
    • 2018
  • An object in the Low Earth Orbit (LEO) is affected by many environmental conditions unlike earth's surface such as, Atomic oxygen (AO), Ultraviolet Radiation (UV), thermal cycling, High Vacuum and Micrometeoroids and Orbital Debris (MMOD) impacts. The effect of all these parameters have to be carefully considered when designing a space structure, as it could be very critical for a space mission. Polybenzimidazole (PBI) is a high performance thermoplastic polymer that could be a suitable material for space missions because of its excellent resistance to these environmental factors. A thin coating of PBI polymer on the carbon epoxy composite laminate (referred as CFRP) was found to improve the energy absorption capability of the laminate in event of a hypervelocity impact. However, the overall efficiency of the shield also depends on other factors like placement and orientation of the laminates, standoff distances and the number of shielding layers. This paper studies the effectiveness of using a PBI coating on the front bumper in a multi-shock shield design for enhanced hypervelocity impact resistance. A thin PBI coating of 43 micron was observed to improve the shielding efficiency of the CFRP laminate by 22.06% when exposed to LEO environment conditions in a simulation chamber. To study the effectiveness of PBI coating in a hypervelocity impact situation, experiments were conducted on the CFRP and the PBI coated CFRP laminates with projectile velocities between 2.2 to 3.2 km/s. It was observed that the mass loss of the CFRP laminates decreased 7% when coated by a thin layer of PBI. However, the study of mass loss and damage area on a witness plate showed CFRP case to have better shielding efficiency than PBI coated CFRP laminate case. Therefore, it is recommended that PBI coating on the front bumper is not so effective in improving the overall hypervelocity impact resistance of the space structure.

Development and utility evaluation of new Multi-Leaf Collimator for Diagnostic X-ray Equipment

  • Ji, Hoon;Han, Su Chul;Baek, Jong Hyeun;Lee, Dong Hoon;Park, Seungwoo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.936-942
    • /
    • 2018
  • The diagnostic multi-leaf collimator preventing unnecessary dose from entering into patients during the diagnostic examination was made in this study. The movement of the entire 50 leaves was embodied with the group of 25 ones thereof configured in a pair facing each other on the left and right of the median line. Dimensions of the length, width, and height of each shielding leaf were $5{\times}0.5{\times}0.5cm^3$ resulting in the maximum boost field of $10{\times}10cm^2$. The material of multi-leaf collimator had the excellence on the machinability with the use of the SKD-11 alloy tool steel having the high wear resistance against frequent movement, and it was devised to control both-side's shielding leaves by moving 2 motors unlike existing remedial multi-leaf collimator that use as many motors as the number of 50 shielding leaves. Thereafter, the transmission dose of leaves, cross-leaf leakage dose, and inter-leaf leakage dose were measured by the developed multi-leaf collimator attached to X-ray equipment. An ionization chamber was used to detect doses there from, and the comparative analysis was carried out by means of the radiographic film that was easy to detect the dose leakage in between each leaf. Results obtained from the test conducted in comparative analysis yielded approximately 98%, 96%, and 94% of shielding efficiency realized at each level of energy of 80kV, 100kV, and 120kV it was confirmed there was no dose leakage resulted from the varied level of irradiation energy. Thus the multi-leaf collimator to be developed based on this study is thought that it could fully reduce the unnecessary dose to patients in the diagnostic test and the shielding efficiency thereof is expected to be increasing if it is made in a miniaturized form with a way of increasing the thickness of each leaf later for an extended application to general diagnostic purposes.

Research on Radiation Shielding Film for Replacement of Lead(Pb) through Roll-to-Roll Sputtering Deposition (롤투롤 스퍼터링 증착을 통한 납(Pb) 대체용 방사선 차폐필름 개발)

  • Sung-Hun Kim;Jung-Sup Byun;Young-Bin Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.441-447
    • /
    • 2023
  • Lead(Pb), which is currently mainly used for shielding purposes in the medical radiation, has excellent radiation shielding functions, but is continuously exposed to radiation directly or indirectly due to the harmfulness of lead itself to the human body and the inconvenience caused by its heavy weight. Research on shielding materials that are human-friendly, lightweight, and convenient to use that can block risks and replace lead is continuously being conducted. In this study, based on the commonly used polyethylene terephthalate (PET) film and the fabric material used in actual radiation protective clothing, a multi-layer thin film was realized through sputtering and vacuum deposition of bismuth, tungsten, and tin, which are metal materials that can shield radiation. Thus, a shielding film was produced and its applicability as a radiation shielding material was evaluated. The radiation shielding film was manufactured by establishing the optimized conditions for each shielding material while controlling the applied voltage, roll driving speed, and gas supply amount to manufacture the shielding film. The adhesion between the parent material and the shielding metal thin film was confirmed by Cross-cut 100/100, and the stability of the thin film was confirmed through a hot water test for 1 hour to measure the change of the thin film over time. The shielding performance of the finally realized shielding film was measured by the Korea association for radiation application (KARA), and the test conditions (inverse wide beam, tube voltage 50 kV, half layer 1.828 mmAl) were set to obtain an attenuation ratio of 16.4 (initial value 0.300 mGy/s, measured value 0.018 mGy/s) and damping ratio 4.31 (initial value 0.300 mGy/s, measured value 0.069 mGy/s) were obtained. by securing process efficiency for future commercialization, light and shielding films and fabrics were used to lay the foundation for the application of films to radiation protective clothing or construction materials with shielding functions.

Changes according to the geometry of the shield using MCNP code system (MCNP코드 시스템을 이용한 차폐물 geometry에 따른 결과 변화에 대한 연구)

  • Kang, Ki-byung;Lee, Nam-ho;Hwang, Young-kwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1031-1033
    • /
    • 2013
  • Radiation protection, as well as finding the location of the radiation source, such as the Fukushima radiation leak accident, it is important for the early and safe disposal of nuclear accident. The three-dimensional position of the radiation source detection distance of the radiation source can provide additional information to the existing radiation detectors radiation of a two-dimensional position detection function and then it can play a decisive role in the radiation contaminant removal and decontamination work. In this research, three-dimensional semiconductor sensor based on dual radiation detectors radiation source device visible part of the research and development of efficient radiation sensor unit on the design of the shielding structure.The lightweight, high-efficiency radiation source locator implementation was attempted for the structure and thickness of the shielding and collimator to perform the simulation of the radiation shielding for the various parameters of the shape model through design the optimal structure of the MCNP-based heavy-duty tungsten shielding, lead shielding The results of this study, is a compact, lightweight three-dimensional radiation source detection and future of silicon - based sensors will be used in the study.

  • PDF

Analysis of Shielding Effect of Lead and Tungsten by use of Medical Radiation (의료 방사선사용에 따른 납과 텅스텐의 차폐효과 분석)

  • Jang, Donggun;Kim, Gyoo Hyung;Park, Cheolwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.173-178
    • /
    • 2018
  • Lead is a very useful material in shielding radiation in hospitals. But lead is toxic. Therefore, there are many studies on substitutable materials, Typically, there are many studies using tungsten. In this study, we investigated the physical properties of lead and tungsten and the Half value layer. As a result, lead having higher atomic number showed higher cross - sectional area than tungsten. But, at the same size, the electron density of tungsten with a high density is about 1.7 times higher than that of lead. In MCNPX simulation, the shielding effect of tungsten is about 1.4 times higher than that of lead, It was confirmed that tungsten had better shielding efficiency than lead. However, considering the economic aspect, tungsten is a rare metal, which is about 25 times more expensive than lead, which is considered to be inappropriate as an alternative to lead.

Study on Exposure Dose and Image Quality of Operator Using Shielding Material in Neuro Interventional Radiology (뇌혈관 중재적 시술에서 차폐체를 이용한 시술자의 피폭선량과 화질에 관한 연구)

  • Kim, Dae-ho;Kim, Sang-hyun;Lee, Young-jin;Lim, Jong-chun;Han, Dong-kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.579-587
    • /
    • 2017
  • Although interventional procedures use very low tube currents, there is a high risk of exposure to radiation as well as the operator due to long-term radiation exposure. The purpose of this study is to investigate the effects of radiation dose on the quality of the operator by measuring the dose received by the operator in the interventional procedure of the cerebral vascular system and finding the shielding material and shielding method which can effectively shield the exposure from the medical radiation. And to find a way to minimize it to the extent that it does not. As a result, when the newly designed shielding system with Nano Tungsten material was used, it was confirmed that the mean dose was reduced by 7.95% on average by the operator. Also, the PSNR results were measured to be 38.44 dB when using the designed shielding material, and it was confirmed that Nano Tungsten does not affect the image quality. In conclusion, the Nano Tungsten shielding material proved to be capable of significantly reducing the operator radiation dose, without affecting the image quality. The use of the above materials is expected to solve the problems related to the harmfulness and economical efficiency of the human body and the environment, which have recently become an issue of shielding materials.

Effect of Replacing Fine Aggregate by Cathode-Ray Tube(CRT) Waste Glass on Gamma-ray Shielding Properties of Cement Mortar Specimen (폐 브라운관(CRT) 유리의 잔골재 대체가 모르타르 시험체의 감마선 차폐에 미치는 영향)

  • Choi, Yoon-Suk;Lee, Seon-Min;Kim, Tae-Sang;Kim, Il-Sun;Yang, Eun-Ik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.172-180
    • /
    • 2019
  • In this study, the microstructure and gamma-ray shielding efficiency of CRT glass mortar specimen were evaluated with replacement ratio and material properties. The results show that as the replacement ratio of CRT waste glass increases, the volume of pores with diameters below 50 nm and above 400 nm is increased. Also, the half-value layer of CRT glass mortar decreased with the increasing of linear attenuation coefficient. In addition, compressive and flexural strength were reduced when CRT waste glass was replaced as the fine aggregate, but the mechanical performance of CRT mortar specimen could be obtained by substitution of the mineral admixture.