Discharge header design inside a reactor pool for flow stability in a research reactor

  • Yoon, Hyungi;Choi, Yongseok;Seo, Kyoungwoo;Kim, Seonghoon
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2204-2220
    • /
    • 2020
  • An open-pool type research reactor is designed and operated considering the accessibility around the pool top area to enhance the reactor utilization. The reactor structure assembly is placed at the bottom of the pool and filled with water as a primary coolant for the core cooling and radiation shielding. Most radioactive materials are generated from the fuel assemblies in the reactor core and circulated with the primary coolant. If the primary coolant goes up to the pool surface, the radiation level increases around the working area near the top of the pool. Hence, the hot water layer is designed and formed at the upper part of the pool to suppress the rising of the primary coolant to the pool surface. The temperature gradient is established from the hot water layer to the primary coolant. As this temperature gradient suppresses the circulation of the primary coolant at the upper region of the pool, the radioactive primary coolant rising up directly to the pool surface is minimized. Water mixing between these layers is reduced because the hot water layer is formed above the primary coolant with a higher temperature. The radiation level above the pool surface area is maintained as low as reasonably achievable since the radioactive materials in the primary coolant are trapped under the hot water layer. The key to maintaining the stable hot water layer and keeping the radiation level low on the pool surface is to have a stable flow of the primary coolant. In the research reactor with a downward core flow, the primary coolant is dumped into the reactor pool and goes to the reactor core through the flow guide structure. Flow fields of the primary coolant at the lower region of the reactor pool are largely affected by the dumped primary coolant. Simple, circular, and duct type discharge headers are designed to control the flow fields and make the primary coolant flow stable in the reactor pool. In this research, flow fields of the primary coolant and hot water layer are numerically simulated in the reactor pool. The heat transfer rate, temperature, and velocity fields are taken into consideration to determine the formation of the stable hot water layer and primary coolant flow. The bulk Richardson number is used to evaluate the stability of the flow field. A duct type discharge header is finally chosen to dump the primary coolant into the reactor pool. The bulk Richardson number should be higher than 2.7 and the temperature of the hot water layer should be 1 ℃ higher than the temperature of the primary coolant to maintain the stability of the stratified thermal layer.

미세 배선 적용을 위한 Ta/Cu 적층 구조에 따른 계면접착에너지 평가 및 분석 (Effect of Ta/Cu Film Stack Structures on the Interfacial Adhesion Energy for Advanced Interconnects)

  • 손기락;김성태;김철;김가희;주영창;박영배
    • 마이크로전자및패키징학회지
    • /
    • 제28권1호
    • /
    • pp.39-46
    • /
    • 2021
  • Cu 배선(interconnect) 적용을 위한 다층박막의 적층 구조에 따른 최적 계면접착에너지(interfacial adhesion energy, Gc) 평가방법을 도출하기 위해, Ta, Cu 및 tetraethyl orthosilicate(TEOS-SiO2) 박막 계면의 정량적 계면접착에너지를 double cantilever beam(DCB) 및 4-점 굽힘(4-point bending, 4-PB) 시험법을 통해 비교 평가하였다. 평가결과, Ta확산방지층이 적용된 시편(Cu/Ta, Cu/Ta/TEOS-SiO2)에서는 두 가지 평가방법 모두 반도체 전/후 공정에서 박리가 발생하지 않는 산업체 통용 기준인 5 J/㎡ 보다 높게 측정되었다. Ta/Cu 시편의 경우 DCB 시험에서만 5 J/㎡ 보다 낮게 측정되었다. 또한, DCB시험 보다 4-PB시험으로 측정된 Gc가 더 높았다. 이는 계면파괴역학 이론에 따라 이종재료의 계면균열 선단에서 위상각의 증가로 인한 계면 거칠기 및 소성변형에 의한 에너지 손실이 증가 하는것에 기인한다. 4-PB시험결과, Ta/Cu 및 Cu/Ta계면은 5 J/㎡ 이상의 높은 계면접착에너지를 보이므로, 계면접착에너지 관점에서는 Ta는 Cu배선의 확산방지층(diffusion barrier layer) 및 피복층(capping layer)으로 적용 가능할 것으로 생각된다. 또한, 배선 집적공정 및 소자의 사용환경에서 열팽창 계수 차이에 의한 열응력 및 화학적-기계적 연마 (chemical mechanical polishing)에 의한 박리는 전단응력이 포함된 혼합모드의 영향이 크므로 4-PB 시험으로 측정된 Gc와 연관성이 더 클 것으로 판단된다.

인공 유방 확대술을 받은 환자의 유방암 치료 시 크기에 따른 반대 측 유방의 피폭 선량 및 차폐 효율 평가 (The evaluation of contralateral breast's dose and shielding efficiency by breast size about breast implant patient for radiation therapy)

  • 김종욱;우헌;정현학;김경아;김찬용;유숙현
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.329-336
    • /
    • 2014
  • 목 적 : 인공 유방 확대술을 받은 환자가 유방암 방사선치료를 받을 경우 유방의 크기별로 치료 조사야와의 거리에 따른 치료반대 측 유방조직에 피폭되는 선량 및 차폐의 효율성을 평가해 보고자 한다. 대상 및 방법 : 인체팬텀(Rando-phantom)을 이용하여 유방 모형의 크기별 (200 cc ~ 500 cc) CT영상을 획득한 후 크기 별로 일 선량 180 cGy의 왼쪽 유방암 방사선 치료계획을 세웠다. 유방 모형이 커질수록 치료 반대 측 유방모형의 표면과 X선의 진행지점 사이에 발생하는 거리가 가까워지게 설정하였고, 체표에 입사하는 선속중심축을 기준으로 3 cm, 6 cm 떨어진 점에서 반대측 유방 표면에 수직으로 내린 거리를 각 A point, B point로 설정하였다. 그리고 유두지점에서 외측으로 2 cm 되는 점을 C point, 체표중앙에서 외측으로 6 cm 되는 점을 D point로 설정하였다. 유방 모형의 크기별로 각 측정지점에 MOSFET을 부착하여 6 MV, 10 MV, 15 MV의 X선 에너지로 조사하여 측정하였다. 이와 동일한 조건으로 납 2 mm의 두께로 차폐한 후의 선량 값과 납 2 mm 아래에 bolus 3 mm를 부착하여 차폐한 후의 선량 값을 얻었다. 결 과 : 유방 모형이 200 cc에서 500 cc로 커짐에 따라 유방 모형의 표면과 X선의 진행지점과의 거리가 A point에서는 2.14 cm에서 최대 1.23 cm으로 근접하였고 B point에서는 2.55 cm에서 1.31 cm으로 근접하였다. 유방 모형의 크기에 따라 180 cGy 기준으로 200 cc 대비 500 cc의 산란선 측정값이 A point에서 3.22 ~ 4.17%, B point에서 4.06 ~ 6.22%, C point는 0.4~0.5% 증가하였고, D point에서는 크기별로 측정값의 차이가 0.4% 미만이었다. X선 에너지가 커짐에 따라 6 MV 대비 15 MV X선에서 180cGy 기준으로 산란선이 A point에서는 4.06~5%, B point에서는 2.85~4.94%, C point에서는 0.74~1.65% 증가하였고, D point에서는 측정값 차이가 0.4% 미만이었다. 차폐체로 납 2 mm를 사용하였을 경우 A와 B point에서 평균 9.74%, C point에서 2.8%, D point에서 1% 미만의 산란선 감소효과가 있었고, 납과 bolus를 함께 차폐하였을 경우 A와 B point에서 평균 9.76%, C point에서 2.2%, D point에서 1% 미만의 산란선 감소효과가 있었다. 결 론 : 일반적으로 인공 유방 확대술을 받은 환자의 경우 유방의 크기에 따라 치료 반대편 유방 표면과 치료조사야의 거리가 가까울수록 유방 표면이 받는 산란선이 증가하였다. 동일한 크기의 유방 모형에서는 사용 X선 에너지가 커질수록 산란선에 의한 피폭이 증가하는 경향을 보였고, 이는 사용 X선의 에너지 선택에 있어 유방암의 방사선 치료계획에서 허용되는 한도에서는 낮은 X선 에너지의 사용이 반대측 유방의 선량 감소에 유리할 것으로 여겨진다.

PET/CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구 (A Study to Decrease Exposure Dose for the Radiotechnologist in PET/CT)

  • 조석원;박훈희;김정열;반영각;임한상;오기백;김재삼;이창호
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.159-165
    • /
    • 2010
  • 방사선 분야는 건강검진의 증가와 방사선 장치의 발달로 진단에서 치료까지 그 업무의 범위가 확대 및 급격히 증가하고 있으며 방사선 종사자의 방사선 피폭 관리가 중요하게 대두되고 있다. PET 검사에 이용되는 양전자 방출핵종은 511 keV의 감마선을 방출하기 때문에 종사자의 방사선 피폭의 증가로 피폭선량 저감을 위한 노력이 요구된다. 본 연구는 환자에게로부터 일정거리 외부선량률을 측정하고 거리에 따른 선량률 변화를 확인하고 차폐를 이용하여 외부선량률의 변화를 알아보았다. 2009년 12월부터 2010년 1월까지 PET/CT 검사를 위해 내원한 10명의 환자를 대상으로 하였다. Digital surveymeter를 이용하여 선량률을 측정하였다. 산란선에 대한 영향을 평가하기 위해서 이동식 방사선 차폐체를 설치하고 왼쪽, 중앙, 오른쪽 부분의 100 cm, 150 cm, 200 cm에서 총 12회 선량률을 측정하였다. 환자 선량률 측정은 $^{18}F$-FDG 5.18 MBq/kg을 주사하고 1시간이 지난 후에 선량이 안정되었을 때 즉시 1회를 측정하였다. 이동식 방사선 차폐체를 설치하기 전에 머리, 가슴, 복부, 무릎, 발끝 쪽의 위치에서 10 cm, 50 cm, 100 cm, 150 cm, 200 cm 위치로 총 80포인트에서 측정하였고 이동형 방사선 차폐체를 설치한 후 머리와 가슴, 복부 부분에서 100 cm, 150 cm, 200 cm 거리의 선량률을 측정하여 외부선량률을 확인하였다. 산란선 측정에 대해서는 위치별로 거리에 따라 분산분석을 시행하였다. 납 차폐를 하지 않았을 때와 차폐를 했을 때의 등선량곡선을 그렸으며 100 cm, 150 cm, 200 cm에 대하여 두 집단간에 상관분석을 시행하였다(SPSS ver. 12). 점 선원을 이용한 산란선 측정에서 100 cm, 150 cm, 200 cm에서는 p>0.05로 유의한 차이가 없었다. 거리가 멀어질수록 선량률이 낮아졌으며 머리 부분이 가장 높은 선량률이 나타났고 발 부분으로 갈수록 선량률이 떨어졌다. 또한 차폐를 하였을 경우 차폐를 하지 않았을 때보다 선량률이 낮아졌으며 100 cm에서 유의한 차이가 있었고(p<0.05) 150 cm, 200 cm에서는 유의한 차이가 없었다(p>0.05). 피폭을 줄이기 위해서는 방사선원에서 거리를 멀리하거나 적당한 차폐체를 이용하는 것이 피폭저감에 도움을 준다. 근무자의 동선을 파악하여 적당한 차폐체를 이용한다면 방사선 종사자의 방사선 피폭을 줄일 수 있을 것이다.

  • PDF

전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가 (Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy)

  • 양명식;차석용;박주경;이승훈;김양수;이선영
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.265-272
    • /
    • 2014
  • 목 적 : 전뇌 방사선 치료 시 산란선으로 인하여 영향을 받는 갑상선의 피폭선량을 감소시키기 위해 차폐체를 사용하여 갑상선의 차폐 효과를 평가하고자 한다. 대상 및 방법 : 갑상선의 피폭선량을 측정하기 위해 선형가속기(Clinac iX. VARIAN, USA)를 이용하여 6 MV X선, 300 cGy를 인체모형팬텀에 대향 2문 조사하였다. 갑상선의 입사표면선량을 측정하기 위해 인체모형팬텀의 10번째 슬라이스 표면에 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 또한, 같은 위치에서 갑상선 심부선량을 측정하기 위해서 인체모형팬텀의 10번째 슬라이스 2.5 cm 깊이에서 유리선량계 다섯 개를 1.5 cm 간격으로 위치시킨 후 차폐체 미사용, bismuth 차폐체 사용, 0.5 mmPb 차폐체 사용, 자체 제작한 1.0 mmPb 차폐체를 사용하여 각각 5회씩 측정하여 평균값을 산출하였다. 결 과 : 갑상선의 입사표면선량은 차폐체 미사용 시 44.89 mGy로 측정되었고, bismuth 차폐체는 36.03 mGy, 0.5 mmPb 차폐체는 31.03 mGy, 자체 제작한 1.0 mmPb 차폐체는 23.21 mGy로 측정되었다. 또한, 갑상선의 심부선량은 차폐체 미사용 시 36.10 mGy로 측정되었고, bismuth 차폐체는 34.52 mGy, 0.5 mmPb 차폐체는 32.28 mGy, 자체 제작한 1.0 mmPb 차폐체는 25.50 mGy로 측정되었다. 결 론 : 전뇌 방사선 치료 시 방사선 조사면 밖의 영역에서 발생하는 이차 산란 및 누출 선량에 의해 영향을 받는 갑상선에 대하여 차폐체를 사용했을 때 갑상선 심부는 약 11~30%, 갑상선 표면은 약 20~48% 정도의 피폭선량 감소 효과가 나타났다. 따라서 전뇌 방사선 치료 시 갑상선 차폐체를 사용함으로써 갑상선을 효과적으로 보호하며 치료를 시행할 수 있을 것으로 사료된다.

MC50 싸이클로트론에서 생성되는 중성자선의 생물학적 특성의 평가 (Evaluation of Biological Characteristics of Neutron Beam Generated from MC50 Cyclotron)

  • 엄근용;박혜진;허순녕;예성준;이동한;박석원;우홍균
    • Radiation Oncology Journal
    • /
    • 제24권4호
    • /
    • pp.280-284
    • /
    • 2006
  • 목 적: 원자력의학원에 설치되어 있는 MC50 사이클로트론에서 생성되는 중성자선의 의학적 이용을 위하여 생물학적 특성을 평가하고자 하였다. 대상 및 방법: 35 MeV 양성자를 15 mm 베릴륨 표적에 부딪혀서 생성된 중성자선에 대하여 물리적 방사선선량을 측정한 후 체외실험(in-vitro)을 하였다. EMT-6 세포주(cell line)를 이용하여 $0{\sim}5\;Gy$의 중성자선을 조사 후 생존분획(surviving fraction)을 구하였다. 또한 감마선의 효과를 피하기 위하여 납차폐를 한 후에 동일 조건에서 생존분획을 구하였다. 엑스선 실험에서는 0, 2, 5, 10, 15 Gy를 조사 후 생존분획을 측정하였다. 결 과: MC50의 중성자선은 조사야 $26{\times}26\;cm^2$, 전류 $10{\mu}A$, 깊이 2 cm에서 84%의 중성자와 16%의 감마선으로 구성되어 있었고, 총선량률은 9.25 cGy/min이었다. 엑스선을 이용하여 측정한 생존분획곡선은 선형이차함수모델 (linear quadratic model)을 적용하였을 때 ${\alpha}/{\beta}$비는 0.611 (${\alpha}=0.0204,\;{\beta}=0.0334,\;R^2=0.999$)이었다. 중성자선에 있어서 생존분획곡선은 저선량 영역에서 어깨영역(shoulder area)을 가지고 있었고, 모든 실험에서 선형이차함수모델에 잘 맞았다. ${\alpha}$의 평균값은 -0.315 (범위, $-0.254{\sim}-0.360$)였고, ${\beta}$값은 0.247 (범위, $0.220{\sim}0.262$)이었다. 납차폐를 하였을 때에도 생존분획곡선에서 어깨영역은 없어지지 않았다. 중성자선의 RBE (relative biological effectiveness) 값은 생존분획이 0.1일 때 $2.07{\sim}2.19$ 범위였고, 0.01일 때 $2.21{\sim}2.35$였다. 결 론: MC50에서 생성된 중성자선은 상당량의 감마선을 내포하고 있으며 이것이 생존분획곡선에서 어깨영역이 나타나는 데에 기여하였을 것이다. MC50의 중성자선의 RBE 값은 약 2.2였다.

PREPARATION OF AMORPHOUS CARBON NITRIDE FILMS AND DLC FILMS BY SHIELDED ARC ION PLATING AND THEIR TRIBOLOGICAL PROPERTIES

  • Takai, Osamu
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2000년도 추계학술발표회 초록집
    • /
    • pp.3-4
    • /
    • 2000
  • Many researchers are interested in the synthesis and characterization of carbon nitride and diamond-like carbon (DLq because they show excellent mechanical properties such as low friction and high wear resistance and excellent electrical properties such as controllable electical resistivity and good field electron emission. We have deposited amorphous carbon nitride (a-C:N) thin films and DLC thin films by shielded arc ion plating (SAIP) and evaluated the structural and tribological properties. The application of appropriate negative bias on substrates is effective to increase the film hardness and wear resistance. This paper reports on the deposition and tribological OLC films in relation to the substrate bias voltage (Vs). films are compared with those of the OLC films. A high purity sintered graphite target was mounted on a cathode as a carbon source. Nitrogen or argon was introduced into a deposition chamber through each mass flow controller. After the initiation of an arc plasma at 60 A and 1 Pa, the target surface was heated and evaporated by the plasma. Carbon atoms and clusters evaporated from the target were ionized partially and reacted with activated nitrogen species, and a carbon nitride film was deposited onto a Si (100) substrate when we used nitrogen as a reactant gas. The surface of the growing film also reacted with activated nitrogen species. Carbon macropartic1es (0.1 -100 maicro-m) evaporated from the target at the same time were not ionized and did not react fully with nitrogen species. These macroparticles interfered with the formation of the carbon nitride film. Therefore we set a shielding plate made of stainless steel between the target and the substrate to trap the macropartic1es. This shielding method is very effective to prepare smooth a-CN films. We, therefore, call this method "shielded arc ion plating (SAIP)". For the deposition of DLC films we used argon instead of nitrogen. Films of about 150 nm in thickness were deposited onto Si substrates. Their structures, chemical compositions and chemical bonding states were analyzed by using X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy and infrared spectroscopy. Hardness of the films was measured with a nanointender interfaced with an atomic force microscope (AFM). A Berkovich-type diamond tip whose radius was less than 100 nm was used for the measurement. A force-displacement curve of each film was measured at a peak load force of 250 maicro-N. Load, hold and unload times for each indentation were 2.5, 0 and 2.5 s, respectively. Hardness of each film was determined from five force-displacement curves. Wear resistance of the films was analyzed as follows. First, each film surface was scanned with the diamond tip at a constant load force of 20 maicro-N. The tip scanning was repeated 30 times in a 1 urn-square region with 512 lines at a scanning rate of 2 um/ s. After this tip-scanning, the film surface was observed in the AFM mode at a constant force of 5 maicro-N with the same Berkovich-type tip. The hardness of a-CN films was less dependent on Vs. The hardness of the film deposited at Vs=O V in a nitrogen plasma was about 10 GPa and almost similar to that of Si. It slightly increased to 12 - 15 GPa when a bias voltage of -100 - -500 V was applied to the substrate with showing its maximum at Vs=-300 V. The film deposited at Vs=O V was least wear resistant which was consistent with its lowest hardness. The biased films became more wear resistant. Particularly the film deposited at Vs=-300 V showed remarkable wear resistance. Its wear depth was too shallow to be measured with AFM. On the other hand, the DLC film, deposited at Vs=-l00 V in an argon plasma, whose hardness was 35 GPa was obviously worn under the same wear test conditions. The a-C:N films show higher wear resistance than DLC films and are useful for wear resistant coatings on various mechanical and electronic parts.nic parts.

  • PDF

투시 검사 시 장비에 따른 환자와 시술자의 입사표면선량 연구 (Fluoroscopic the equipment study in accordance with the entrance surface dose study of patients and practitioners)

  • 양해두;홍선숙;성민숙;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.13-18
    • /
    • 2013
  • Purpose : Fluoroscopy equipment, depending on the type of changes that occur in the patient's position ESD and study the patient's scatter ray of ESD Practitioners considered a comparative analysis was to evaluate the correct dose. Materials and Methods : HITACHI four overtube type TU-8000 Flat Detector and Under tube C-Arm Philips' Multi Diagnost Eleva with Flat Detector type were measured by. Each devices is a measure of the patient's esd randophantom position in tabel unfors Xi multi funtion then fixed to the abdomen fluoroscopy and 10 seconds, spot was measured three times, practitioners of the incident surface dose by considering the patient's scatter ray of the table for each device in the average human stomach 21cm thickness acrylic phantom ($25cm{\times}25cm$) Place the practitioner position after position randophantom unfors Xi multi funtion in the thyroid and stomach 1 minute by a fixed one-time fluoroscopy and measured. Results : 10 seconds and the patient perspective of the c-arm ESD 1.2 times smaller on the AP and oblique measurements were measured in the 6-13 times smaller. spot positions to changes in the measured three times on the AP of the abdomen, ESD is 18 times smaller c-arm measurements and the oblique measurement was 19-30 times smaller. And 1 minute at practitioners fluoroscopy esd in the thyroid 2.12 times the c-arm, chest 1.75 times less the dose was measured. On the AP, depending on the device, but the lack of dose difference oblique positions of the two devices depending on changes in the area due to changes in both the AP than on the dose increased, the difference in dose between the two devices, the maximum difference was approximately 27 times. Conclusion : Fluoroscopic equipment at the time of inspection in accordance with changes in dose according to the patient and the patient's positions changes, because the area of the scatter ray considering the change of dose measurements be made, and study of the equipment according to the characteristics of the efficiency and the exposure of the patient and practitioner is considered smooth study equipment manufacturers that can be done is to build the system and think that is also important. Various fluoroscopy when you check future changes in many factors of change in dose for the equipment in the laboratory system by considering the scatter ray radiation shielding for the management to take advantage of reckless undertube have been utilized as more exposure Reduction activities can help is considered as the direction.

  • PDF

Grain Refinement를 통한 Mg-Ca-Zn합금의 기계적 특성 및 부식 특성 향상 (Improvement of Mechanical and Corrosion Properties of Mg-Ca-Zn Alloy by Grain Refinement)

  • 김대한;최종민;임현규
    • 한국산학기술학회논문지
    • /
    • 제18권9호
    • /
    • pp.418-424
    • /
    • 2017
  • 마그네슘은 다른 금속들에 비해 비강도가 높으며, 우수한 진동 흡수능, 전자파 차폐성 등으로 산업 전반에 많이 활용되고 있다. 예를 들면, 자동차 시트 프레임, 실린더 헤드 등 자동차 부품으로도 사용되며 노트북 케이스, 핸드폰 케이스 등의 전자제품에도 널리 사용되고 있다. 또한 신체의 뼈가 금이 가거나 부서졌을 경우, 그 손상된 뼈의 치료를 보조하기 위해 사용되는 골 접합용 임플란트 재료로 각광받고 있다. 현재 임플란트 재료로는 Ti alloy, Stainless steel, Co-Cr-Mo alloy등이 사용되어 지고, Mg 합금은 연구단계에 머물러 있다. 현재 골접합용 임플란트 재료의 문제점으로는 한번 접합 수술 후에 회복이 되면 이것을 제거하기 위한 수술을 또 해야 한다는 점이 있다. 하지만 마그네슘은 현재 재료와 비교하여 충분한 강도를 실현 할 수 있으며, 일정시간 후 자체적으로 분해되고 인체에 무해한 원소기 때문에 연구가 진행되고 있다. 그러나 순수 Mg으로는 충분한 강도와 내식성을 가질 수 없기 때문에 합금원소를 첨가하여 Mg 합금을 설계한다. 본 논문에서는 마그네슘에 인체에 무해한 Ca, Zn를 첨가하여 합금을 설계하였고, 추가적으로 강도와 내식성을 향상시키기 위해서 Grain refiner로서 Sr을 소량 첨가하여 최종 합금을 설계하였다. Sr은 방사선 원소는 인체에 유해하지만, 그 외 천연 Sr 원소는 인체에 무해하다. 이렇게 제조된 합금을 광학현미경, 주사전자현미경을 통해 미세조직분석을 수행하고, 인장시험, 동전위 분극 시험, 침지시험을 통해 기계적 특성 및 부식특성을 평가하였다. 결론적으로, Sr 첨가에 의해 조직이 미세해졌으며, 기계적 특성 및 내식성이 향성된 것을 확인 할 수 있었다.

전산화 단층검사 시 Bismuth와 CARE kV System을 이용한 선량 저감화에 대한 연구 (Research on Dose Reduction During Computed Tomography Scanning by CARE kV System and Bismuth)

  • 곽영곤;김종일;정성표
    • 한국콘텐츠학회논문지
    • /
    • 제14권8호
    • /
    • pp.233-242
    • /
    • 2014
  • 본 논문에서는 전산화 단층검사 시 방사선 투과 물질로 방사선량을 흡수하여 피폭 선량을 감소시키는 물질로 알려진 차폐용 Bismuth(비스무스)와 CARE kV(Automated Dose-Optimized Selection of X-ray Tube Voltage)을 사용하여 유용성을 평가하였다. 방사선 감수성이 높은 기관인 수정체(안와), 갑상선, 가슴(유방), 생식기의 선량 감소 효과와 각 기관의 심부선량 차폐 효과를 평가하기 위해 Rando Phantom과 유리 선량계를 이용하여 Bismuth 사용 전 후와, CARE kV의 적용에 따른 선량 감소 효과를 비교해 보았다. 그 결과, 뇌혈관 검사 시 CARE kV을 단독 설정한 검사 방법의 선량이 가장 적었으며, CARE kV 사용여부에 따라 63%의 선량 감소 효과가 있었다. 경동맥 검사 시 CARE kV+Bismuth의 설정 방법에서 선량이 13% 증가하였다. 심혈관 검사 시 CARE kV+Bismuth의 설정 방법이 31% 선량 감소 효과가 있었다. 하지 혈관 검사 시 Bismuth 전체의 설정 방법이 가장 선량이 적게 측정되었지만, 영상 평가 기준에 부적합 하였다. CARE kV을 설정한 검사 방법과는 약 9%의 선량 감소 효과가 있었다.