Effect of rare earth dopants on the radiation shielding properties of barium tellurite glasses

  • Vani, P.;Vinitha, G.;Sayyed, M.I.;AlShammari, Maha M.;Manikandan, N.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4106-4113
    • /
    • 2021
  • Rare earth doped barium tellurite glasses were synthesised and explored for their radiation shielding applications. All the samples showed good thermal stability with values varying between 101 ℃ and 135 ℃ based on dopants. Structural properties showed the dominance of matrix elements compared to rare earth dopants in forming the bridging and non-bridging atoms in the network. Bandgap values varied between 3.30 and 4.05 eV which was found to be monotonic with respective rare earth dopants indicating their modification effect in the network. Various radiation shielding parameters like linear attenuation coefficient, mean free path and half value layer were calculated and each showed the effect of doping. For all samples, LAC values decreased with increase in energy and is attributed to photoelectric mechanism. Thulium doped glasses showed the highest value of 1.18 cm-1 at 0.245 MeV for 2 mol.% doping, which decreased in the order of erbium, holmium and the base barium tellurite glass, while half value layer and mean free paths showed an opposite trend with least value for 2 mol.% thulium indicating that thulium doped samples are better attenuators compared to undoped and other rare earth doped samples. Studies indicate an increased level of thulium doping in barium tellurite glasses can lead to efficient shielding materials for high energy radiation.

A study of model for nitrogen permeation in TIG welding of super duplex stainless steel (슈퍼듀플렉스 스테인리스강의 TIG 용접에서 질소 침투 모델에 관한 연구)

  • Lee, Jae-Hyoung;Jung, Byong-Ho;Cho, Sang-Myung;Jun, Jae-Ho
    • Journal of Welding and Joining
    • /
    • v.33 no.3
    • /
    • pp.68-74
    • /
    • 2015
  • Superduplex stainless steels are important materials to the oil and gas industry, especially for off-shore production. TIG welding of super duplex stainless steels to obtain the optimal phase balance between austenite and ferrite is mainly achieved by controlling the cooling rate and the weld chemistry. The latter depends on the filler wire chosen and the shielding gas used. If TIG welding of superduplex stainless steels is performed with argon shielding gas only, then nitrogen gets lost from the weld pool, which can result in a ferrite-rich weld metal, with an inferior corrosion resistance than parent metal. In the present study, nitrogen permeation model from the shield gas which gets into the weld metal in DCEN-TIG welding has suggested. This plasma stream model shows characteristics of permeation of nitrogen ions into the molten metal due to the strong physical effect of plasma stream which formed by the arc pressure rather than the permeation of nitrogen ions caused by electric effect.

The Usefulness Evaluation of Radiation Shielding Devices in PET Scan Procedures (PET 검사 프러시저별 방사선 차폐기구의 유용성 평가)

  • Kim, Yeong-Seon;Seo, Myeong-Deok;Lee, Wan-Kyu;Jeong, Yo-Cheon;Kim, Sang-Wook;Seo, Il-Teak;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.65-76
    • /
    • 2010
  • Purpose: he use of PET scanners and the number of patient in Korea have been increased for recent several years dramatically. For this reason, technologists have more possibilities to be exposed to the radiation. The hospitals using PET scanners should make an effort to reduce the radiation exposure dose. The purpose of this study was to evaluate the radiation exposure does when using radiation shielding devices. The evaluation was performed through questionnaire survey and experiment. Materials and Methods: First, the technologists who had experience working in PET center in 2008-2009 were surveyed with questionnaire and TLD Figures, personal opinion of utilization of radiation shielding devices are analyzed. Second, we measured the shielding rate of shielding devices which have been using in PET study procedures. We divided the procedures into four steps; distribution, moving, injection of $^{18}F$-FDG and patient setup. Results: First, the results of this survey, using of L-block+Syringe shield, L-block, Syringe shield, No shield during the injection, were each 58.5%, 20%, 9%, 12.3%. The TLD values according to utilization of radiation shield, using both L-block+Syringe Shield and L-block showed the lower TLD values, and Syringe shield only or No shield showed the higher TLD values. Second, the results of experiments according to PET study procedures measured the shielding rates as follows. The shielding rates during the distribution using L-block, L-block+Apron shield were measured 97.4%, 97.7%. The shielding rates during the $^{18}F$-FDG delivery to the injection room using mobile Syringe shield, Syringe holder, Syringe shield carrier were each 81.7%, 98.9%, 99.7%. The shielding rates during the injection using Syringe shield, L-block, L-block+Syringe shield were measured each 51.9%, 98.3%, 98.7%. The shielding rates of Apron were measured in each 30, 60, 90, 120, 150 cm distance. The measurement were each 16.9%, 14.2%, 16.6%, 17.1%, 18.1%, 18.6%. Conclusion: The most effective method for radiation shielding is to using L-block during the $^{18}F$-FDG distribution and Syringe shield carrier during in moving $^{18}F$-FDG. For the $^{18}F$-FDG injection, L-block+Syringe shield have to be used. The shielding effect of Apron has shown average 16.4%. According to the survey of questionnaire, the operators recognized well risk of the radiation exposure but, tended ignore in working. The radiation dose according to recognition of radiation exposure risk was not relevant. but radiation dose according to utilization of radiation shield lower the more use it. The main reason of no use of shielding devices is cumbersome, 55% of the respondents answered. I'm sure, by use of radiation shield in all PET procedure, radiation exposure will be reduced considerably.

  • PDF

The Study of Dose Change by Field Effect on Atomic Number of Shielding Materals in 6 MeV Electron Beam (6 MeV 전자선의 차폐물질 원자번호와 조사야 크기에 따른 선량변화 연구)

  • Lee, Seung Hoon;Kwak, Keun Tak;Park, Ju Kyeong;Gim, Yang Soo;Cha, Seok Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.145-151
    • /
    • 2013
  • Purpose: In this study, we analyzed how the dose change by field size effects on atomic number of shielding materials while using 6 MeV election beam. Materials and Methods: The parallel plate chamber is mounted in $25{\times}25cm^2$ the phantom such that the entrance window of the detector is flush with the phantom surface. phantom was covered laterally with aluminum, copper and lead which thickness have 5% of allowable transmission and then the doses were measured in field size $6{\times}6$, $10{\times}10$ and $20{\times}20cm^2$ respectively. 100 cGy was irradiated using 6 MeV electron beam and SSD (Source Surface Distance) was 100 cm with $10{\times}10cm^2$ field size. To calculate the photon flux, electron flux and Energy deposition produced after pass materals respectively, MCNPX code was used. Results: The results according to the various shielding materials which have 5% of allowable transmission are as in the following. Thickness change rate with field size of $6{\times}6cm^2$ and $20{\times}20cm^2$ that compared to the field size of $10{\times}10cm^2$ found to be +0.06% and -0.06% with aluminum, +0.13% and -0.1% with copper, -1.53% and +1.92% with lead respectively. Compare to the field size $10{\times}10cm^2$, energy deposition for $6{\times}6cm^2$ and $20{\times}20cm^2$ had -4.3% and +4.85% respectively without shielding material. With aluminum it had -0.87% and +6.93% respectively and with lead it had -4.16% and +5.57% respectively. When it comes to photon flux with $6{\times}6cm^2$ and $20{\times}20cm^2$ of field sizes the chance -8.95% and +15.92% without shielding material respectively, with aluminum the number -15.56% and +16.06% respectively and with copper the chance -12.27% and +15.53% respectively, with lead the number +12.36% and -19.81% respectively. In case of electron flux in the same condition, the number -3.92% and +4.55% respectively without shielding material respectively, with aluminum the number +0.59% and +6.87% respectively, with copper the number -1.59% and +3.86% respectively, with lead the chance -5.15% and +4.00% respectively. Conclusion: In this study, we found that the required thickness of the shielding materials got thinner with low atomic number substance as the irradiation field is increasing. On the other hand, with high atomic number substance the required thickness had increased. In addition, bremsstrahlung radiation have an influence on low atomic number materials and high atomic number materials are effected by scattered electrons.

  • PDF

Development of Lead Free Shielding Material for Diagnostic Radiation Beams (의료영상용 방사선방호를 위한 무납차폐체 개발)

  • Choi, Tae-Jin;Oh, Young-Kee;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.232-237
    • /
    • 2010
  • The shielding materials designed for replacement of lead equivalent materials for lighter apron than that of lead in diagnostic photon beams. The absorption characteristics of elements were applied to investigate the lead free material for design the shielding materials through the 50 kVp to 110 kVp x-ray energy in interval of 20 kVp respectively. The idea focused to the effect of K-edge absorption of variable elements excluding the lead material for weight reduction. The designed shielding materials composited of Tin 34.1%, Antimon 33.8% and Iodine 26.8% and Polyisoprene 5.3% gram weight account for 84 percent of weight of lead equivalent of 0.5 mm thickness. The size of lead-free shielder was $200{\times}200{\times}1.5\;mm^3$ and $3.2\;g/cm^3$ of density which is equivalent to 0.42 mm of Pb. The lead equivalent of 0.5 mm thickness generally used for shielding apron of diagnostic X rays which is transmitted 0.1% for 50 kVp, 0.9% for 70 kVp and 3.2% for 90 kVp and 4.8% for 110 kVp in experimental measurements. The experiment of transmittance for lead-free shielder has showed 0.3% for 50 kVp, 0.6% for 70 kVp, 2.0% for 90 kVp and 4.2% for 110 kVp within ${\pm}0.1%$. respectively. Using the attenuation coefficient of experiments for 0.5 mm Pb equivalent of lead-free materials showed 0.1%. 0.3%, 1.0% and 2.4%, respectively. Furthermore, the transmittance of lead-free shielder for scatter rays has showed the 2.4% in operation energy of 50 kVp and 5.9% in energy of 110 kVp against 2.4% and 5.1% for standard lead thickness within ${\pm}0.2%$ discrepancy, respectively. In this experiment shows the designed lead-free shielder is very effective for reduction the apron weight in diagnostic radiation fields.

Experimental Study on the Development of EMP Shielded Concrete Using Industrial By-products (산업부산물을 사용한 EMP차폐 콘크리트 개발에 관한 실험적 연구)

  • Min, Tae-Beom;Kim, Hyeong-Cheol;Choi, Hyun-Kuk;Roh, Jeong-Heon;Kim, Kuk-Joo;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.477-484
    • /
    • 2019
  • The purpose of this study is to present basic data for developing concrete with EMP shielding as the structure materials when constructing an EMP shielded building structure. In order to use metal-based recycled aggregates with excellent conductivity and easy procurement for EMP shielding concrete, an evaluation of the stability evaluation and EMP shielding performance was performed. Through the stability evaluation, it was found that the coarse aggregate stability criterion was satisfied, but the oxidized slag did not satisfy the fine aggregate stability criterion, the oxidized slag is not satisfied. In addition, as a result of fresh concrete, the workability is increased and the air volume is decreased. The compressive strength is increased due to the high density and coarse granularity of the recycled aggregates, which increased the cement paste and adhesion, thereby increasing the compressive strength. The results of an EMP shielding test show that aggregates with high shielding performance are electronic arc furnace(EAF) Oxidizing Slag and Cooper Slag. The shielding performance is expected to increase if the average particle size of aggregate is small or uniformly distributed.

A Study on Barium Mixed Radiation Shield using 3D Printer (3D 프린터를 이용한 바륨혼합형 차폐체에 대한 연구)

  • Gang, Heon-Hyo;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.627-634
    • /
    • 2020
  • Instead of lead, we intend to develop shielding materials for morphological implementation by mixing barium sulfate, an eco-friendly substance, and PLA filament, a 3D printer material. The environmental substance, barium sulfate powder and PLA filament, a 3D printer material, were used, and the shielding was made with a 3D printer after being fused into an extruder to mix the powder powder of barium sulfate with PLA. To check the mixing ratio of barium sulfate powder and PLA filament, the mixing input was analyzed, and the absorption dose by thickness according to barium sulfate content was obtained to check the shielding function of the mixed shielding. In the evaluation of the mixture of sulfate barium powder particles and PLA filaments, it was mixed in the most appropriate proportion when the content was 30% in the apparent and electron microscopic observation photographs. In the absorption dose results by thickness according to barium sulfate content, the difference between the content of 0% and the content of each % was greatest at 0.5 cm in thickness and the lowest dose value at 3 cm in thickness when the barium content was 30%. In addition, as the barium content began to increase at 30%, the absorbed dose value increased again. Instead of conventional lead, barium sulfate, an eco-friendly substance, could be mixed with PLA, a filament material, to create morphological shielding. Based on this study, it is expected that the mixing ratio of barium to the mixture is the most appropriate 30%, and will be used as the basis for the implementation of morphological shielding using 3D printers in the diagnosis and treatment section.

Evaluation of Shielding Performance of 3D Printer Materials for High-energy Electron Radiation Therapy (고 에너지 전자선 치료를 위한 3D 프린터 물질의 차폐 성능평가)

  • Chang-Woo, Oh;Sang-Il, Bae;Young-Min, Moon;Hyun-Kyoung, Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.687-695
    • /
    • 2022
  • To find a 3D printer material that can replace lead used as a shield for high-energy electron beam treatment, the shielding composites were simulated by using MCNP6 programs. The Percent Depth Dose (PDD), Flatness, and Symmetry of linear accelerators emitting high-energy electron beams were measured, and the linear accelerator was compared with MCNP6 after simulation, confirming that the source term between the actual measurement and simulation was consistent. By simulating the lead shield, the appropriate thickness of the lead shield capable of shielding 95% or more of the absorbed dose was selected. Based on the absorption dose data for lead shield with a thickness of 3 mm, the shielding performance was analyzed by simulating 1, 5, 10, and 15 mm thicknesses of ABS+W (10%), ABS+Bi (10%), and PLA+Fe (10%). Each prototype was manufactured with a 3D printer, measured and analyzed under the same conditions as in the simulation, and found that when ABS+W (10%) material was formed to have a thickness of at least 10mm, it had a shielding performance that could replace lead with a thickness of 3mm. The surface morphology and atomic composition of the ABS+W (10%) material were evaluated using a scanning electron microscope (SEM) and an energy dispersive X-ray spectrometer (EDS). From these results, it was confirmed that replacing the commercialized lead shield with ABS+W (10%) material not only produces a shielding effect such as lead, but also can be customized to patients using a 3D printer, which can be very useful for high-energy electron beam treatment.