• Title/Summary/Keyword: Shielding Calculation

Search Result 134, Processing Time 0.023 seconds

SHIELDING PERFORMANCE OF A NEWLY DESIGNED TRANSPORT CASK IN THE ADVANCED CONDITIONING SPENT FUEL PYROPROCESS FACILITIY

  • Park, Chang-Je;Jeong, Chang-Joon;Min, Deok-Ki;Kang, Hee-Young;Choi, Woo-Seok;Lee, Joo-Chan;Bang, Gyeoung-Sik;Seo, Ki-Seog
    • Nuclear Engineering and Technology
    • /
    • v.40 no.4
    • /
    • pp.319-326
    • /
    • 2008
  • To transport process wastes efficiently from the Advanced Spent Fuel Conditioning Pyro-process Facility (ACPF) at the Korea Atomic Energy Research Institute (KAERI), a new hot cell cask has been designed based on an existing hot cell padirac transport cask, with not only a neutron absorber for improved shielding capability, but also a docking facility for an easy docking system. In the new hot cell cask, two kinds of materials have been considered as shielding materials, polyethylene and resin. To verify the transport compatibility of the waste and spent fuel for the ACPF, neutron and photon shielding calculations were performed using the MCNPX code. The source term was evaluated by the ORIGEN-ARP code system based on spent PWR fuel. From the calculation, it was found that the maximum surface dose rates of the hot cell cask with the two candidates were estimated within the limit (2 mSv/hr).

Verification of the Radiation Shielding Analysis of Shipping Cask Using Deterministic and Probabilistic Methods (결정론적인 방법과 확률론적인 방법을 이용한 수송용기 방사선차폐해석의 비교 및 검증)

  • Yoon, Jeong-Hyoung;Lee, In-Koo;Bang, Kyoung-Sik;Choi, Byoung-Il;Kim, Chong-Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.1
    • /
    • pp.17-25
    • /
    • 1996
  • In this study, to set-up the calculation method of radiation shielding of the KSC-4 shipping cask which is being used for spent fuel transportation, the pre-existing two calculation methods, deterministic and probabilistic methods were tested. For the first, the DOT4.2 computer code adopting the deterministic theory was applied for the calculation of effective neutron shielding under assumption of continuous wall thickness of the cask. To verify the first results, the probabilistic theory was used as an alternate calculation. In this case MCNP4A computer code adopting the probabilitic theory was used. And same approximation was obtained from the two different shielding calculations. From the results, it could be confirmed that the design and calculation method used for the radiation shielding of the KSC-4 was adequate and sufficiently safe to meet the design and QA requirements of 10CFR71 Appendix H.

  • PDF

BENCHMARK CALCULATION OF CANDU END SHIELDING SYSTEM

  • Gyuhong Roh;Park, Hangbok
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.618-623
    • /
    • 1998
  • A shielding analysis was performed for the end shield of CANDU 6 reactor. The one-dimensional discrete ordinate code ANISN with a 38-group neutron-gamma library, extracted from DLC-37D library, was used to estimate the dose rate for the natural uranium CANDU reactor. For comparison MCNP-4B calculation was performed for the same system using continuous, discrete and multi-group libraries. The comparison has shown that the total dose rate of the ANISN calculation agrees well with that of the MCNP calculation. However, the individual dose rate (neutron and gamma) has shown opposite trends between AMISN and MCNP estimates, which may require a consistent library generation for both codes.

  • PDF

The Calculation Model of Electron Output for the Cut-out Fields, in Consideration of Shielding Area. (차폐면적의 변화에 따르는 전자선 출력인자의 변화)

  • 이병용;김정만;김정화;권경태;이두현;이강현;최은경;장혜숙
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.61-68
    • /
    • 1990
  • We have designed the calculation model(AMC method) of electron output for the cut-out fieldsand studied the influence of shielding block size. The output of electron was measured in the water phantom at dmax, for 20 $\times$ 20cm$^2$ cone size electron beams from CL/1800 linear accelerator(Varian, USA), Which generates the energy of 6, 9, 12, 15 and 18MeV electron beams. The shielding blocks were rectangular or squre shaped, low melting point alloy. We can predict the output from the arbitrarily rectangular shaped block within 1% error. by using the AMC method, which considers the contribution of the collimator(block) scatter and the phantom scatter.

  • PDF

A Modified Calculation of Electromagnetic Shielding Effectiveness Considering Some electrical Parameters (발산가응계통에서의 뉴톤-랍슨 전력게통합)

  • Sang-Jin Lee;Myung-Hwan Oh
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.31 no.12
    • /
    • pp.173-179
    • /
    • 1982
  • This paper presents a modified quasi-static approximate solution derived from the Maxwell's equations of integral form for the calculation of magnetic shielding effectiveness in a non-uniform enclosure such as metal-clad high-voltage test laboratory. It also describes the simplified relationship between the electrical parameters applicable to the engineering calculations of electromagnetic absorption loss which comprise the resultant effects due to the welding seams and short-circuited slots as well as the shielding material properties. A numerical example shows the fairly good agreements with experimental results measured on the absorption loss vs. incident wave frequency without any unreasonable rapid increase.

  • PDF

Simple Calculation Method as a Supplementary Radiation Safety Assessment for Facility with Radiation Generator

  • Kim, Sang-Tae
    • International Journal of Contents
    • /
    • v.14 no.4
    • /
    • pp.65-69
    • /
    • 2018
  • The objective of this study was to conduct a radiation shielding analysis for the facility equipped with radiation generator. The analysis was carried out in two aspects. First, from the aspect of the effect caused by primary and leakage radiation. Second, effect of scattered radiation was evaluated by applying a simple calculation method based on a scattering rate concept since effect of scattered radiation is significantly important at maze entrance of the radiation facility. The calculated results obtained using the simple method were compared to the results calculated using Geant4 code and the measured values. The results calculated by the suggested method indicate that slight error exists in a radiation shielding analysis done at the maze entrance comparing to other two results, while the results evaluated at the outside of the maze entrance door are relatively consistent with other values.

A study on lighting performance of 345[KV] model line (345[KV] 송전선로의 뇌방호 실패의 예측과 그 대책에 관한 연구)

  • 이봉용
    • 전기의세계
    • /
    • v.29 no.1
    • /
    • pp.65-72
    • /
    • 1980
  • Arstrong-Whitehead theory on effective shielding and shielding failure is extended so that it is applicable to vertical line configuration the existing approaches on back-flash rate calculation are summerized and compared in particular on Model Line, and the usefulness of the whitehead approach is suggested.

  • PDF

Discontinuous finite-element quadrature sets based on icosahedron for the discrete ordinates method

  • Dai, Ni;Zhang, Bin;Chen, Yixue
    • Nuclear Engineering and Technology
    • /
    • v.52 no.6
    • /
    • pp.1137-1147
    • /
    • 2020
  • The discrete ordinates method (SN) is one of the major shielding calculation method, which is suitable for solving deep-penetration transport problems. Our objective is to explore the available quadrature sets and to improve the accuracy in shielding problems involving strong anisotropy. The linear discontinuous finite-element (LDFE) quadrature sets based on the icosahedron (in short, ICLDFE quadrature sets) are developed by defining projected points on the surfaces of the icosahedron. Weights are then introduced in the integration of the discontinuous finite-element basis functions in the relevant angular regions. The multivariate secant method is used to optimize the discrete directions and their corresponding weights. The numerical integration of polynomials in the direction cosines and the Kobayashi benchmark are used to analyze and verify the properties of these new quadrature sets. Results show that the ICLDFE quadrature sets can exactly integrate the zero-order and first-order of the spherical harmonic functions over one-twentieth of the spherical surface. As for the Kobayashi benchmark problem, the maximum relative error between the fifth-order ICLDFE quadrature sets and references is only -0.55%. The ICLDFE quadrature sets provide better integration precision of the spherical harmonic functions in local discrete angle domains and higher accuracy for simple shielding problems.

A Metamodeling Approach for Leader Progression Model-based Shielding Failure Rate Calculation of Transmission Lines Using Artificial Neural Networks

  • Tavakoli, Mohammad Reza Bank;Vahidi, Behrooz
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.760-768
    • /
    • 2011
  • The performance of transmission lines and its shielding design during a lightning phenomenon are quite essential in the maintenance of a reliable power supply to consumers. The leader progression model, as an advanced approach, has been recently developed to calculate the shielding failure rate (SFR) of transmission lines using geometrical data and physical behavior of upward and downward lightning leaders. However, such method is quite time consuming. In the present paper, an effective method that utilizes artificial neural networks (ANNs) to create a metamodel for calculating the SFR of a transmission line based on shielding angle and height is introduced. The results of investigations on a real case study reveal that, through proper selection of an ANN structure and good training, the ANN prediction is very close to the result of the detailed simulation, whereas the Processing time is by far lower than that of the detailed model.

Analysis for shielding effectiveness of a satellite electronic equipment enclosure with a dielectric-backed aperture (유전체로 막힌 개구를 갖는 위성 전자 장비 함체의 차폐 효과 해석)

  • Kim, Su-Han;Lee, Jae-Hyun
    • Journal of Satellite, Information and Communications
    • /
    • v.3 no.1
    • /
    • pp.35-40
    • /
    • 2008
  • In this paper, a new analytical formulation is presented for calculating shielding effectiveness (SE) of shielding enclosure including satellite electronic components and equipments. The shielding enclosure has a dielectric-backed aperture. The SE may be a function of frequency, dielectric constant, and position within the enclosure. And, the formulation has been extended for calculation of the SE of the structure where the one side of dielectric is partially backed by conductor. Our simulation results give that the dielectric material lowers the Q factor, and the further the observation point is from the aperture, the more SE increases.

  • PDF