• Title/Summary/Keyword: Shielded Room

Search Result 66, Processing Time 0.021 seconds

Optimum Combination of Pickup Coil Type and Magnetically Shielded Room for Maximum SNR to Measure Biomagnetism (생체신호 측정을 위한 최대의 신호 대 잡음비를 가지는 검출코일의 형태 와 자기차폐실의 최적 조합)

  • Yu, K.K.;Lee, Y.H.;Kang, C.S.;Kim, J.M.;Park, Y.K.
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.45-49
    • /
    • 2007
  • We have investigated the optimum combination of the environmental noise condition and type of SQUID pickup coil in order to obtain maximum signal-to-noise ratio (SNR). The measurement probe consists of 1st order gradiometer with pickup coils of 100 mm, 70 mm, and 50 mm baseline length, a 2nd order gradiometer with 50 mm baseline, and a magnetometer. The pickup coils are fabricated by winding Nb wire on a bobbin with 200 mm diameter. Noise and heart signal of a healthy male were measured by various SQUID sensors with different types of pickup coils in various magnetically shielded rooms (MSR), and compared to each other. The shielding factors were found to be 43 dB, 35 dB and 25 dB at 0.1 Hz for MSR-AS, MSR-BS, MSR-CS, respectively. White noises were $3.5\;fT/Hz^{1/2}$, $4.5\;fT/Hz^{1/2}$ and $3\;fT/Hz^{1/2}$ for the 1st order gradiometers, the 2nd order gradiometers, and magnetometer for all MSRs. SNR of the magnetometer was up to 56 dB in MSR-AS, while the 1st order axial gradiometer with 70 mm baseline length was up to 54 dB in MSR-BS. The 2nd order axial gradiometer with 50 mm baseline length of pickup coil was found to be up to 40 dB in MSR-CS.

  • PDF

Integrated 3-Channel Flux-Locked-Loop Electronics for the Readout of High-$T_c$ SQUID (고온초전도 SQUID 신호 검출을 위한 3채널용 FLL 회로)

  • 김진목;김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.55-60
    • /
    • 2003
  • We designed and constructed integrated 3-channel flux-locked-loop (FLL) electronic system for the control and readout of high-T$_{c}$ SQUIDs. This system consists of low noise preamplifiers, integrators, interface circuits, and software. FLL operation was carried out with biased signals of 19 KHz modulated current and 150 KHz modulated flux, which are reconstructed as detected signals by preamplifier and demodulator. Computer controlled interface circuits regulate FLL circuit and adjust SQUID parameters to the optimum operating condition. The software regulates interface circuits to make an auto-tuning for the control of SQUIDs, and displays readout data from FLL circuit. 3-channel SQUID electronic system was assembled with 3 FLL-interface circuit boards and a power supply board in the aluminum case of 56 mm ${\times}$ 53 mm${\times}$ 150 mm. Overall noise of the system was around 150 fT/(equation omitted)Hz when measured in the shielded room, 200 fT/(equation omitted)Hz in a weakly shielded room, respectively.y.

  • PDF

Construction and Performance of Magnetically Shielded Room for Biomagnetic Applications (생체자기계측을 위한 자기차폐실의 설치 및 특성)

  • 이용호;권혁찬;김진목;임청무;이상길;박용기;박종철
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.4
    • /
    • pp.264-271
    • /
    • 1996
  • A magnetically shielded room has been constructed for biomagnetic applications. The room has internal dimensions of $2\;m(length){\times}2\;m(width){\times}2.5\;m(height)$ and it consists of high permeability Mumetal and high conductivity alummum, utilizing ferromagnetic shielding and eddy current shielding. The de shielding factor around the center of the room is above 60 dB, and the ac shielding factors at 1 and 10 Hz are larger than 60 and 80 dB, respectively. The internal magnetic field noise at 1 Hz is $500\;fT/{\sqrt}Hz$ and at 10 Hz is $100\;fT/{\sqrt}Hz$, and the field gradient noise at 1 Hz is below $7\;fT/cm{\sqrt}Hz$. Successful measurements of cardiomagnetic fields usmg SQUID magnetometer and neuromagnetic fields using SQUID gradiometer have been done.

  • PDF

An Electrochemical Evaluation of the Corrosion Property on the Welded Zone of Sea Water Pipe by each Welding Materials (용접 재료 별 해수 배관 용접부위의 부식 특성에 관한 전기화학적 평가)

  • Kim, Jin-Gyeong;Won, Chang-Uk;Moon, Kyung-Man
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.185-188
    • /
    • 2006
  • The sea water pipe of engine room in all kinds of ships is being surrounded with severe corrosive environment. Therefore it's leakage part due to corrosion is inevitably prevented by various welding method. In this case corrosion property of welded zone may be considerably different by each welding materials. In this study corrosion resistance of the welded zone of sea water pipe with some welding materials such as shielded metal arc welding materials, inert gas arc welding materials was investigated with electrochemical method.

  • PDF

A Study on Scattered Dose in Operation Room by C-arm Unit (수술중 C-arm 장치의 사용에 따른 공간선량 분포에 관한 연구)

  • An, Sung-Min;Oh, Jung-Hwan;Kim, Sung-Chul
    • Journal of radiological science and technology
    • /
    • v.23 no.2
    • /
    • pp.69-73
    • /
    • 2000
  • This paper studied a C-arm's exposure condition and measured scatter rays by thickness and distance. This study reached the following conclusion. 1. Approrimately exposure dose for a patient using fluoroscopy is as follows : 2. Mostly, an operating room was not shielding by lead and operator put on only apron without thyroid and facial part protection. 3. 0.5 mmPb equivalent's apron shielded about 99% of scattered rays at 60 cm from x-ray tube. 4. Scattered rays are depended on distance and thickness so operators are should be careful when using fluoroscopy by C-arm and if possible use high frequency equipment that has a large output.

  • PDF

Magnetocardiography System in Open-door Magnetically-shielded Room (열린 자기차폐실의 심자도 시스템)

  • Kim, J.M.;Lee, Y.H.;Kwon, H.;Yu, K.K.;Kim, K.;Park, Y.K.;Sasada, Ichiro
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.50-55
    • /
    • 2007
  • We have installed a 61-channel magnetocardiography (MCG) system inside a magnetically shielded room (MSR) with a size of $2.4\;m\;{\times}2.4\;m\;{\times}2.4\;m$. The MCG system consists of 1st-order axial gradiometers containing double relaxation oscillation SQUIDs (DROSs) with pick-up coils of a base line of 70 mm. The MSR holds a shielding factor of 50 at 0.1 Hz and 10000 at 100 Hz, when its door in the middle on a front wall is closed. On opening the MSR door, we have obtained the characteristics of the MCG system with a 2.9 Hz noise generated from an air conditioning unit at 13 m distance off the MSR. In an open-door MSR ($140^{\circ}$ opening), a noise at the center channel increases up to $700\;fT/Hz^{l/2}$ at 2.9 Hz and $1.7\;pT/Hz^{1/2}$ at 60 Hz. MCG signals for a healthy human do not show distortion until the door opens to $45^{\circ}$, but show the effect of noise when the door opens further at $90^{\circ}$ and $140^{\circ}$. With the door opens to $45^{\circ}$, MCG measurement can be performed with ease of door operation and without creating claustrophobia for the patient.

  • PDF

Measurement of fMCG Signals using an Axial Type First-Order SQUID Gradiometer System (권선형 1차 미분계를 이용한 태아심자도 신호 측정)

  • Yu, K.K.;Kim, K.;Kang, C.S.;Kim, J.M.;Lee, Y.H.
    • Progress in Superconductivity
    • /
    • v.10 no.2
    • /
    • pp.139-143
    • /
    • 2009
  • We have fabricated a low-noise 61-channel axial-type first-order gradiometer system for measuring fetal magnetocardiography(MCG) signals. Superconducting quantum interference device(SQUID) sensor was based on double relaxation oscillation SQUID(DROS) for detecting biomagnetic signal, such as MCG, magnetoencphalogram(MEG) and fetal-MCG. The SQUID sensor detected axial component of fetal MCG signal. The pickup coil of SQUID sensor was wound with 120 ${\mu}m$ NbTi wire on bobbin(20 mm diameter) and was a first-order gradiometer to reject the environment noise. The sensors have low white noise of 3 $fT/Hz^{1/2}$ at 100 Hz on average. The fetal MCG was measured from $24{\sim}36$ weeks fetus in a magnetically shielded room(MSR) with shielding factor of 35 dB at 0.1 Hz and 80 dB at 100 Hz(comparatively mild shielding). The MCG signal contained maternal and fetal MCG. Fetal MCG could be distinguished relatively easily from maternal MCG by using independent component analysis(ICA) filter. In addition, we could observe T peak as well as QRS wave, respectively. It will be useful in detecting fetal cardiac diseases.

  • PDF

Improvement of Magnetic SE Measurement of Shielded Rooms Using Rectangular Loop Antennas (직사각형 루프 안테나를 이용한 차폐실의 자기장 차폐효과 측정 방법 개선)

  • Park, Hyun Ho;Hyoung, Chang Hee;Kwon, Jong Hwa
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.320-323
    • /
    • 2019
  • This paper examines a disadvantage of low-frequency magnetic shielding measurement based on MIL-STD-188-125-1. A rectangular loop antenna is proposed as an improvement over conventional circular loop antennas for measuring magnetic shielding. Simulation and experiment are used to demonstrate that the proposed rectangular loop outperforms the circular loop for a more reliable shielding measurement at low frequency range.