• Title/Summary/Keyword: Shield Effectiveness

Search Result 75, Processing Time 0.04 seconds

Analysis of Shielding Effectiveness and Estimation of Shielding Factor in Conductive and Magnetic Shields (도전성 및 자성 차폐체의 차폐효과 해석과 차폐인수 산정)

  • Kang, Dae-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.10
    • /
    • pp.30-40
    • /
    • 2013
  • In this study the method based on flux linkage in cell was introduced in calculation of eddy currents by cell method. According to this method eddy current distribution and the loss can be evaluated and since the shielding effectiveness by flux cancelation of eddy current can be analyzed, this method is applicable to design of conductive shield. And also the formula of shielding factor were so deduced as to be applicable to finite-width infinite-length shielding sheets and infinite-length underground cable shield. These formula are adaptable to magnetic materials as well as conductive materials. As the results of calculation in model shields are follows. In case of finite-width infinite-length shielding sheet, shielding effectiveness increases with increasing of conductivity. In case of infinite-length underground cable shield, the effectiveness become higher with increasing of permeability. Especially the effectiveness is very high in materials with both high conductivity and permeability in underground cable shield.

A Study on Improvement of Method for Measuring the Shield Performance of Shielding Enclosures (전자파 차폐실의 차폐효과 측정방법 개선에 관한 연구)

  • Yeon, Jae-Sung;Kim, Hie-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.350-353
    • /
    • 2009
  • The shielding enclosure is very essential device to test the electromagnetic wave power generated by various RF equipments. Some standards for the shielding enclosures were established to test them in right method. Generally, There are IEEE-STD-299 and MIL-STD-285 and NSA-65-6 of the method for measuring the effectiveness of shielding enclosures, the IEEE-STD-299 combined MIL-STD-285 and NSA-65-6 about the method for measuring shielding effectiveness(SE) about 1969 years, but, the measurement point of 299 proposal is many points(including shielding wall, seam, coner beat, shielding door, etc) and demand long time of measurement. To improve SE test method for shielding enclosures was studied and suggested to develop a proper test procedure. First, we measure reference level as frequency range and H/V polarization, secondly, measure leakage point, and finally, measure shield effect and calculate SE. Our method has a merit of the less measurement point than IEEE-STD-299, and shorten time than 299, and define representation SE of shielding enclosure effectively.

  • PDF

Settlement behaviours and control measures of twin-tube curved buildings-crossing shield tunnel

  • Jianwei, Jia;Ruiqi, Gao;Defeng, Wang;Jianjun, Li;Ziwen, Song;Jinghui, Tan
    • Structural Engineering and Mechanics
    • /
    • v.84 no.5
    • /
    • pp.699-706
    • /
    • 2022
  • Settlement control techniques are critical for the safety of shield tunnel constructions, especially for facing complex situations. In this study, the shield tunnel structure from Huaita east road station to Heping Road station in Xuzhou metro No.3 line (China) is taken as engineering background, which has various complex problems of the upper-soft and lower-hard composite stratum conditions, twin curve shield tunnels, and underpass the foundation of the piled raft. The deformation characteristics of shield tunnelling passing through buildings are explored. Subsequently, comprehensive research methods of numerical simulation and field measurement are adopted to analyzing the effectiveness of settlement control by using the top grouting technique. The results show that the settlement of the buildings has obvious spatial characteristics, and the hysteresis effect can be obviously observed in soil deformation caused by shield construction. Meanwhile, the two shield constructions can cause repeated disturbances, reducing the soil deformation's hysteresis effect. Moreover, the shield tunnel's differential settlement is too large when a single line passes through, and the shield construction of the outer curve can cause more significant disturbance in the tunnel than the inside curve. Notably, the proposed process control parameters and secondary topgrouting method can effectively control the deformation of the shield tunnel, especially for the long-term deformation.

Evaluation of base shield plates effectiveness in reducing the drag of a rough circular cylinder in a cross flow

  • EL-Khairy, Nabil A.H.
    • Wind and Structures
    • /
    • v.11 no.5
    • /
    • pp.377-389
    • /
    • 2008
  • An experimental investigation has been conducted to determine the effectiveness of base shield plates in reducing the drag of a rough circular cylinder in a cross flow at Reynolds numbers in the range $3{\times}10^4{\leq}Re{\leq}10.5{\times}10^4$. Three model configurations were investigated and compared: a plane cylinder (PC), a cylinder with a splitter plate (MC1) and a cylinder fitted with base shield plates (MC2). Each configuration was studied in the sub and supercritical flow regimes. The chord of the plates, L, ranged from 0.22 to 1.50D and the cavity width, G, between the plates was in the range from 0 to 0.93D. It is recognized that base shield plates can be employed more effectively than splitter plates to reduce the aerodynamic drag of circular cylinders in both the sub- and supercritical flow regimes. For subcritical flow regime, one can get 53% and 24% drag reductions for the MC2 and MC1 models with L/D=1.0, respectively, compared with the PC model. For supercritical flow regime however, the corresponding drag reductions are 38% and 7%.

Calculation of induced currents and analysis of shielding effectiveness in shield (유한폭 무한장 차폐판의 차폐효과 해석)

  • Kang, Dael-Ha;Park, Sang-Ho;Park, Yun-Dong;Shim, Jae-Gu;Rho, Il-Soo;Kim, Ku-Song;Kim, Huy-Chil
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.549-550
    • /
    • 2011
  • In this study simple formula of magnetic field in case of shield with finite-width infinite-length were deduced. By using these formula calculation is very fast and programing is easy. The formula are applicable to analysis of shielding effectiveness and the design for shield of distribution lines.

  • PDF

Seismic response characteristics of base-isolated AP1000 nuclear shield building subjected to beyond-design basis earthquake shaking

  • Wang, Dayang;Zhuang, Chuli;Zhang, Yongshan
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.170-181
    • /
    • 2018
  • Because of the design and construction requirements, the nuclear structures need to maintain the structural integrity under both design state and extreme earthquake shaking. The base-isolation technology can significantly reduce the damages of structures under extreme earthquake events, and effectively protect the safeties of structures and internal equipment. This study proposes a base-isolation design for the AP1000 nuclear shield building on considering the performance requirements of the seismic isolation systems and devices of shield building. The seismic responses of isolated and nonisolated shield buildings subjected to design basis earthquake (DBE) shaking and beyond-design basis earthquake (BDBE) shaking are analyzed, and three different strategies for controlling the displacements subjected to BDBE shaking are performed. By comparing with nonisolated shield buildings, the floor acceleration spectra of isolated shield buildings, relative displacement, and base shear force are significantly reduced in high-frequency region. The results demonstrate that the base-isolation technology is an effective approach to maintain the structural integrity which subjected to both DBE and BDBE shaking. A displacement control design for isolation layers subjected to BDBE shaking, which adopts fluid dampers for controlling the horizontal displacement of isolation layer is developed. The effectiveness of this simple method is verified through numerical analysis.

Improvement for Shielding Effectiveness of EMI Shield Layers using Conformal Spray Coating Scheme (콘포멀 스프레이 코팅으로 형성한 EMI 차단막의 차폐효과 개선)

  • Hur, Jung;Lee, Won-Hui
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.107-112
    • /
    • 2018
  • Shielding effectiveness (SE) improvement with EMI shield layers fabricated by conformal spray coating system was studied. Silver or Nickel powder filled acrylic resin were sprayed on the samples. We compared the performance with the viscosity of 400 cPs and 100 cPs cases. The thickness range of the coating layer was 20 to 50 um for the silver, 60 to 120 um for the nickel. The shielding effectiveness was measured by ASTM D4935 using coaxial type TEM-cell. The silver-filled resin showed much better performance than that of the nickel-filled resin. The shielding effectiveness increased almost proportional to the thickness of the coating layers until being saturated around 63 dB for the silver-layer or around 34 dB for the nickel-layer. The best performance measured in this study was the shielding effectiveness of 63 dB with $35{\mu}m-thick$ of silver-layer.

The Electromagnetic Shield Properties of 600V class Low Voltage Cable Using Carbon Fiber (탄소섬유를 이용한 600V 이하 저압 케이블의 전자파 차폐특성)

  • Kim, Young-Seok;Kim, Taek-Hee;Kim, Chong-Min;Shong, Kil-Mok;Kim, Ji-Yeon;Kim, Won-Seok;Kwag, Dong-Soon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.1
    • /
    • pp.243-248
    • /
    • 2017
  • This study used general carbon fibers(CF), which can be utilized for a low voltage cable screen, as well as metal-coated carbon fibers(MCF) to make cables and analyzed the properties of electromagnetic effectiveness. Both braid CF and MCF cables with 3,000 strands, 16 spindles, and braid density of 90% or over were adopted. The tape-type MCF specimens were spread into a tape(width: 15mm) using a hot melt to make a cable. The shield effectiveness was measured up to the 1GHz range in accordance with IEC 62153-4-6; braid shielded cables featured a superior shielding effect at 63dB than tape-type shielded cables. That was because the tape-type shielded cable has relatively more gaps and holes between carbon fibers than the braid type, resulting in a more inflow or emission of electromagnetic waves. In the case of braid cables, the characteristics of their electromagnetic waves were enhanced, with higher spindles and higher conductivity of carbon fibers. The shield effectiveness of the MCF shielded cable, however, was lower than that of tin-coated one.

Optimum Design of a Shield Plate to minimize Extremely-Law-Frequency Magnetic Fields produced by Bus Bars (분전반 모선에 의해 발생되는 극저주파 자기장 저감을 위한 차폐판 최적 설계)

  • Jeung, Gi-Woo;Choi, Nak-Sun;Kim, Dong-Hun;Jang, Nak-Won;Lee, Dong-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.57-62
    • /
    • 2009
  • This paper deals with the optimal design of a shield plate in order to minimize Extremely-Low-Frequency(ELF) magnetic fields generated from three-phase bus bars. Combining an evolutionary strategy with a 3D finite element analysis tool, the main dimensions of the shield plate are sought out. The optimization procedure consists of two separated design stages to take into account all foreseen structures of the plate. In the first stage, the basic dimensions of the plate are optimized including the distance between the plate and the bus bars. Then the usefulness of the additional structures such as a slit and fillet is investigated in the second stage. Finally the optimum design of the shield plate is suggested from the viewpoint of the shielding effectiveness and manufacturing cost.

Thermal Protection Shield Concept for Diamond Impregnated Tools

  • Tillmann, W.;Gathen, M.;Kronholz, C.
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.875-876
    • /
    • 2006
  • For dry machining of mineral materials the Institute of Materials Engineering pursues a novel thermal protection shield concept for diamond tools, in which thermal insulating materials in diamond composite structures act as heat shield, which protects diamonds in deeper layers against high temperature and graphitisation. Before the effectiveness of this concept could be investigated suitable composites have to be manufactured. In this paper the powder metallurgical production processes of diamond-alumina-cobalt-composites with varying alumina and cobalt particle sizes, their microstructures and porosities are described. It could be observed that the distribution of small-sized alumina particles ($<70{\mu}m$) in the cobalt matrix is uniform and the porosity of the composite decrease.

  • PDF