• 제목/요약/키워드: Shedding frequency

검색결과 272건 처리시간 0.04초

주기적으로 회전진동하는 원주 후류의 공진특성에 관한 연구 (Lock-on Characteristics of Wake Behind a Rotationally Oscillating Circular Cylinder)

  • 이정엽;이상준
    • 대한기계학회논문집B
    • /
    • 제29권8호
    • /
    • pp.895-902
    • /
    • 2005
  • Lock-on characteristics of flow around a circular cylinder oscillating rotationally with a relatively high forcing frequency have been investigated experimentally. Dominant governing parameters are Reynolds number (Re), angular amplitude of oscillation (${\theta}_A$), and frequency ratio $F_R=f_f/f_n,\;where\;f_f$ is a forcing frequency and $f_n$ is a natural frequency of vortex shedding. Experiments were carried out under the conditions of $Re=4.14{\times}10^3,\;{\pi}/90{\leq}{\theta_A}{\leq}{\pi}/3,\;and\;F_R=1.0$. The effect of this active flow control technique on the lock-on flow characteristics of the cylinder wake was evaluated with wake velocity measurements and spectral analysis of hot-wire signals. The rotational oscillation modifies the flow structure of near wake significantly. The lock-on phenomenon always occurs at $F_R=1.0$, regardless of the angular amplitude ${\theta}_A$. In addition, when the angular amplitude is less than a certain value, the lock-on characteristics appear only at $F_R=1.0$,. The range of lock-on phenomena expands and vortex formation length is decreased, as the angular amplitude increases. The rotational oscillation create a small-scale vortex structure in the region just near the cylinder surface. At ${\theta}_A=60^{\circ}$, the drag coefficient was reduced about $43.7\%$ at maximum.

플레이트형 지지구조체로 지지된 실린더형 관 군의 고주파 유동유발진동 및 압력손실에 대한 실험적 고찰 (Experimental investigation on the high frequency flow-induced vibration and pressure drop of cylindrical tube bundle with plate type supporting structures)

  • 이강희;김형규;윤경호;엄경보;김진선;서정민
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1367-1372
    • /
    • 2008
  • A plate type supporting structure of a tube bundle in axial flow generates a certain band of a high frequency periodic excitation of a vortex shedding and/or a flow separation due to sharp edge of the plate thickness and a severe pressure drop due to a cross-sectional area of the supports. With a design consideration of the low vibration and a small flow resistance, the analysis method is uniquely confined to an experimental approach because a complex geometry of a cylindrical tube bundle and/or physical phenomena related to the fluid-structure interaction of tube bundle in a flow impede a theoretical or a numerical approach. A 5x5 cylindrical tube bundle with 5 supports which were discretely located along the bundle's axis was tested in the FIVPET hydraulic test loop for a design evaluation and an analysis perspectives. A high frequency flow-induced vibration of the supporting structures of the cylindrical tube bundle was measured at a outer surface of a supporting structure through a transparent flow housing by the laser dopper vibrometer. Pressure drop in-between three measurement distances was measured by the differential pressure transmitter. High frequency vibration and pressure drop fairly depends on the geometric design of supporting structure. So, these two parameters would be used as a qualitative design variables for design evaluation and analysis.

  • PDF

Lattice-Boltzmann Method를 이용한 이중구조팬의 공력소음 해석 및 저감 (Aeroacoustics Analysis and Noise Reduction of Dual Type Combined Fan using Lattice-Boltzmann Method)

  • 김우택;류민형;김진욱;호성환;조이상;조진수
    • 한국항공우주학회지
    • /
    • 제44권5호
    • /
    • pp.381-390
    • /
    • 2016
  • 본 연구에서는 이중구조팬의 소음특성을 알아보고 소음저감 방법으로 알려진 톱니형 뒷전(Serrated Trailing Egde)을 적용하여 이중구조팬의 소음을 저감시켰다. 해석에는 Lattice Boltzmann Method(LBM)를 이용한 비정상 전산해석을 수행하였으며 해석의 타당성을 평가하기 위하여 시험을 실시하였다. 이중구조팬은 일반적인 팬처럼 단일의 Blade Passing Frequency(BPF)를 갖는 것이 아니라 내부팬과 외부팬 각각의 BPF가 서로 다른 음역대에서 나타나는 것을 확인 하였다. 톱니형 뒷전을 내부팬에 적용하여 경계층에서의 구속와류와 뒷전에서의 와류흘림이 억제 또는 분산되고 광역소음뿐만 아니라 팬의 토크도 저감되었다.

진공청소기 원심홴의 유동과 소음원 해석 (An Alysis of Flow and Noise Source for Vacuum Cleaner Centrigugal Fan)

  • 전완호;유기완;이덕주;이승갑
    • 소음진동
    • /
    • 제7권1호
    • /
    • pp.99-106
    • /
    • 1997
  • Centrigugal fans are widely used due to their ability to achieve relatively high pressure ratios in a short axial distance compared to axial fans. Because of their widespread use, the noise generated by these machines causes one of serious problems. In general, centrigugal fan noise is often dominated by tones at BPF(blade passage frequency) and its higher harmonics. This is a consequence of the strong interaction between the periodic flow discharged radially from the impeller and the stator blades or the cutoff. But in vacuum cleaner fan the noise is dominated by not only the discrete tones of BPF but also broadband frequencies. In this study we investigate the mechanism of broadband noise and predict for the unsteady flow field and the acoustic pressure field associated with the centrifugal fan. DVM(discrete vortex method) is used to calculates the flow field and the Lowson's method is used to predict the acoustic pressures. From the results we find that the broadband noise of a circular casing centrifugal fan is due to the unsteady force fluctuation around the impeller blades related to the vortex shedding. The unsteady forces associated with the shed vortices at impeller and related to the interactions to the diffuser and the exit.

  • PDF

Features of the flow over a finite length square prism on a wall at various incidence angles

  • Sohankar, A.;Esfeh, M. Kazemi;Pourjafari, H.;Alam, Md. Mahbub;Wang, Longjun
    • Wind and Structures
    • /
    • 제26권5호
    • /
    • pp.317-329
    • /
    • 2018
  • Wake characteristics of the flow over a finite square prism at different incidence angles were experimentally investigated using an open-loop wind tunnel. A finite square prism with a width D = 15 mm and a height H = 7D was vertically mounted on a horizontal flat plate. The Reynolds number was varied from $6.5{\times}10^3$ to $28.5{\times}10^3$ and the incidence angle ${\alpha}$ was changed from $0^{\circ}$ to $45^{\circ}$. The ratio of boundary layer thickness to the prism height was about ${\delta}/H=7%$. The time-averaged velocity, turbulence intensity and the vortex shedding frequency were obtained through a single-component hotwire probe. Power spectrum of the streamwise velocity fluctuations revealed that the tip and base vortices shed at the same frequency as that ofspanwise vortices. Furthermore, the results showed that the critical incidence angle corresponding to the maximum Strouhal number and minimum wake width occurs at ${\alpha}_{cr}=15^{\circ}$ which is equal to that reported for an infinite prism. There is a reduction in the size of the wake region along the height of the prism when moving away from the ground plane towards the free end.

덤프 연소기에서의 연소불안정과 능동제어에 대한 연구 (Combustion Instability and Active Control in a Dump Combustor)

  • 안규복;;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제25회 추계학술대회논문집
    • /
    • pp.445-449
    • /
    • 2005
  • 혼합 acoustic-convective 모드 연소불안정과 스피커를 이용한 능동제어의 가능성에 대한 연구를 수행 하였다. 유입속도, 연소실 길이, 당량비를 변화시켜 가면서 동압과 화염구조를 동시 측정하였다. 유입속도와 연소실 길이는 덤프 연소기에서의 와류 생존시간에 영향을 주기 때문에, 연소길 길이가 길어질수록 그리고 유입속도가 작아질수록 연소불안정의 주파수는 작아지고, 동압에서 얻어진 최대 전력스펙트럼밀도 또한 전반적으로 작아지는 경향을 보였다. 당량비에 따라 불안정의 강도와 주파수 특성도 변했는데, 당량비의 증가에 따라 불안정 주파수와 연소불안정 강도는 증가하는 경향을 나타내었다. 폐루프 방식의 제어를 통하여 스피커를 이용한 능동제어는 이러한 혼합 acoustic-convective 모드 연소불안정으로 발생하는 와류의 발전을 감소시킬 수 있음을 확인하였다.

  • PDF

V-gutter형 보염기를 장착한 모델 연소기 내의 연소 주파수 발생 메커니즘 연구 (An Experimental Study on Mechanism of Combustion Frequencies in Model Combustor with V-gutter type Flameholder)

  • 송진관;황정재;송재천;윤영빈;이종근
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.277-280
    • /
    • 2009
  • 본 연구는 v-gutter형 보염기를 장착한 연소기 내에 발생한 연소 주파수의 발생 메커니즘에 대해 규명 하는 것이다. 연소기는 $40{\times}40\;mm$의 단면적을 가진 긴 덕트 형상을 가지고 있으며, 14mm의 폭을 가진 v-gutter 형의 보염기를 장착하였다. 연료로 등유와 메탄를 수직 분무하여 실험을 수행하였다. 연소 시 발생하는 주파수는 연소기의 형상에 기인한 1L 종방향 모드와 보염기에서 발생하는 와류 주파수가 주로 발생함을 확인하였다. 또한 연료의 특성에 기인한 주파수와 노즐의 영향에 대한 주파수가 저주파 영역에서 발생함을 확인하였다.

  • PDF

풍하중을 받는 테이퍼 고층건물의 진동변위응답 평가 (The Evaluation in Displacement Response of Tapered Tall Buildings to Wind Load)

  • 조지은;유기표;김종수;김영문
    • 한국공간구조학회논문집
    • /
    • 제5권4호
    • /
    • pp.101-108
    • /
    • 2005
  • 고층건물의 진동응답을 저감시키기 위한 다양한 방법들이 연구되고 있다. 이들 진동응답의 저감 연구는 건물의 외관을 병화 시키는 방법과 건물에 부가감쇠장치를 설치하는 방법들이 있는데 본 논문에서는 고층 건물의 형태의 변화에 다른 진동변위응답의 특성을 파악하고자 한다. 고층건물의 형태변화 중에서도 외관에 테이퍼를 수는 방법을 사용하였다. 기류의 특성은 도심 및 교외지역을 중심으로 풍동실험을 실시하였다.

  • PDF

전자석 액츄에이터를 이용한 구 주위의 유동제어 (Active control of flow over a sphere using electro-magnetic actuators)

  • 박진일;최해천;전우평
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.497-501
    • /
    • 2000
  • Flow over a sphere is controlled experimentally at $Re=10^5$ using electro-magnetic actuators. The electro-magnetic actuator developed in this study is composed of the permanent magnet electro-magnet membrane and slot. Eight actuators are placed inside the sphere at equally spaced intervals on a latitudinal plane and the position of the control slot is 76 from the stagnation point. Each actuator generates a periodic blowing and suction through the slot at variable frequencies of $10{\sim}140Hz$ and variable amplitudes by controlling electric signals applied to the electro-magnet. Drag on the sphere measured using a load cell is significantly reduced with control at the forcing frequencies larger than the natural shedding frequency $({\approx}14Hz\;at\;Re=10^5)$, whereas drag is slightly increased at the forcing frequency of 10Hz. It is shown from pressure measurement that the static pressure in the rear surface of the sphere is significantly increased with control, indicating that the separation is delayed due to control. Flow visualizations also show that the detaching shear layer is more attracted to the sphere center with control, the separation bubble size is significantly reduced, and motion inside the bubble is very weak, as compared to the case of uncontrolled flow.

  • PDF

생체모방공학을 적용한 고속철 차간 공간의 공력소음 연구 (Analysis of aerodynamic noise at inter-coach space of high speed trains based on biomimetic analogy)

  • 한재현;김태민;김정수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.711-716
    • /
    • 2011
  • Today, high-speed trains enjoy wide acceptance as fast, convenient and environment-friendly means of transportation. However, increase in the speed of the train entails a concomitant increase in the aerodynamic noise, adversely affecting the passenger comfort. At the train speed exceeding 300 km/h, the effects of turbulent flows and vortex sheddding are greatly amplified, contributing to a significant increase in the aerodynamic noise. Drawing a biomimetic analogy from low-noise flight of owl, a method to reduce aerodynamic noise at inter-coach space of high-speed trains is investigated. The proposed method attempts to achieve the noise reduction by modifying the turbulent flow and vortex shedding characteristics at the inter-coach space. To determine the aerodynamic noise at various train speeds, wind tunnel testing and numerical CFD (Computational Fluid Dynamics) simulation for the basic inter-coach spacing model are carried out, and their results compared. The simulation and experimental results reveal that there are discrete frequency components associated with turbulent air flow at constant intervals in the frequency domain

  • PDF