• Title/Summary/Keyword: Shedding frequency

Search Result 271, Processing Time 0.023 seconds

Numerical Simulation of the Vortical flow around an Oscillating Circular Cylinder (진동하는 원형주상체 주위의 와류 수치 모사)

  • 김광수;이승재;서정천
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.40 no.2
    • /
    • pp.21-27
    • /
    • 2003
  • The phenomena of vortex shedding around a cylinder oscillating harmonically in a fluid at rest are investigated by a two-dimensional numerical simulation of the Navier-Stokes equations. The simulation is based on a vorticity-velocity integro-differential formulation dealing with vorticity, velocity and pressure variables. Three combinations of Reynolds number(Re) and Keulegan-Carpenter number(KC) were taken to investigate the associated vortex development around the cylinder in the different flow regimes. Drag and lift forces are computed to describe their dominant frequency modulation which is related to the vortex shedding and to the harmonic motion of the cylinder.

Study of rate of change of frequency by Reclosing and Load shedding (부하차단과 재폐로 동작에 따른 주파수변화율 크기 분석)

  • Lee Jae Wook;Park Chul Woo;Jang Byung Tae;Song In Jun;Jang Moon Seop;Kwak No Hong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.397-399
    • /
    • 2004
  • A small-sized isolated 154kV transmission system could be brought out by a separation from whole network due to faults at transmission lines. For such system, where a fault occurs following a reclosing action, we Provided the basis for study to provide an effective load shedding scheme needed to the case of failure of reclosing action as well as the characteristic of reclosing action whether it succeeds or fails.

  • PDF

Q1D modeling of hydrodynamic instabilities in solid rocket motors

  • M., Grossi;D., Bianchi;B., Favini
    • Advances in aircraft and spacecraft science
    • /
    • v.9 no.5
    • /
    • pp.479-491
    • /
    • 2022
  • This work concerns the investigation of a Q1D methodology employed to study pressure oscillations in solid rocket motors driven by hydrodynamic instabilities. A laboratory-scale solid motor designed to develop vortex-shedding phenomena is analyzed for the whole firing time. The comparison between numerical results and experimental data shows good agreement regarding pressure oscillations signature, especially in the flute-mode behavior, the typical oscillations frequency trend present in any motor liable to hydrodynamic instabilities. Such result ensures the model capability to cope with this particular kind of pressure oscillations source, allowing the investigation of the phenomenon with a lighter and cost savings methodology than CFD simulations.

Investigation on the effect of vibration frequency on vortex-induced vibrations by section model tests

  • Hua, X.G.;Chen, Z.Q.;Chen, W.;Niu, H.W.;Huang, Z.W.
    • Wind and Structures
    • /
    • v.20 no.2
    • /
    • pp.349-361
    • /
    • 2015
  • Higher-mode vertical vortex-induced vibrations (VIV) have been observed on several steel box-girder suspension bridges where different vertical modes are selectively excited in turn with wind velocity in accordance with the Strouhal law. Understanding the relationship of VIV amplitudes for different modes of vibration is very important for wind-resistant design of long-span box-girder suspension bridges. In this study, the basic rectangular cross-section with side ratio of B/D=6 is used to investigate the effect of different modes on VIV amplitudes by section model tests. The section model is flexibly mounted in wind tunnel with a variety of spring constants for simulating different modes of vibration and the non-dimensional vertical amplitudes are determined as a function of reduced velocity U/fD. Two 'lock-in' ranges are observed at the same onset reduced velocities of approximately 4.8 and 9.4 for all cases. The second 'lock-in' range, which is induced by the conventional vortex shedding, consistently gives larger responses than the first one and the Sc-normalized maximum non-dimensional responses are almost the same for different spring constants. The first 'lock-in' range where the vibration frequency is approximately two times the vortex shedding frequency is probably a result of super-harmonic resonance or the "frequency demultiplication". The main conclusion drawn from the section model study, central to the higher-mode VIV of suspension bridges, is that the VIV amplitude for different modes is the same provided that the Sc number for these modes is identical.

Wind Tunnel Test Study on the Characteristics of Wind-Induced Responses of Tall Buildings with Openings (중공부(中空部)를 가진 고층건축물(高層建築物)의 풍응답(風應答) 특성(特性)에 관한 풍동실험(風洞實驗) 연구(硏究))

  • Kim, Dong Woo;Kil, Yong Sik;Ha, Young Cheol
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.499-509
    • /
    • 2005
  • The excessive wind-induced motion of tall buildings most frequently result from vortex-shedding-induced across-wind oscillations. This form of excitation is most pronounced for relatively flexible, lightweight, and lightly damped high-rise buildings with constant cross-sections. This paper discusses the aerodynamic means ofmitigating the across-wind vortex shedding induced in such situations. Openings are added in both the drag and lift directions in the buildings to provide pressure equalization. Theytend to reduce the effectiveness of across-wind forces by reducing their magnitudes and disrupting their spatial correlation. The effects of buildings with several geometries of openings on aerodynamic excitations and displacement responses have been studied for high-rise buildings with square cross-sections and an aspect ratio of 8:1 in a wind tunnel. High-frequency force balance testshave been carried out at the Kumoh National University of Technology using rigid models with 24 kinds of opening shapes. The measured model's aerodynamic excitations and displacement were compared withthose of a square cylinder with no openings to estimate the effectiveness of openings for wind-induced oscillations. From these results, theopening shape, size, and location of buildings to reduce wind-induced vortex shedding and responses were pointed out.

A study of Instability on Oscillating Laminar Premixed Flames (진동하는 층류예혼합화염의 불안정성에 관한 연구)

  • Lee, Won-Nam
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.4
    • /
    • pp.8-15
    • /
    • 2008
  • When a circular cylinder is placed at the center of a slot burner nozzle, once stable Woflhard-Parker type laminar lean premixed flame is changed to an oscillating flame with self-induced noise. The wrinkled flame surface showed the same pattern and frequency of the Karman vortex street at the downstream of a circular cylinder. The interaction of flame with Karman vortex street is observed to be responsible for flame oscillation. The measured flame oscillation frequency is very similar to the estimated Karman vortex shedding frequency based on the St-Re relationship of the flow past circular cylinder, which could be considered as a strong evidence for the interaction between laminar pre-mixed flame and a Karman vortex street. As Reynolds number increases oscillation frequency decreases and the self-induced noise level increases as well as the flame front is more severly wrinkled. This result suggests that the flame/vortex interaction becomes more active at higher Re.

  • PDF

A Case Study on The Reduction and Examination for Noise and Vibration of Backpass Heat Surface in the Power Plant Boiler (발전용 보일러의 후부 전열면 소음진동 저감에 관한 사례 연구)

  • Lee, Gyoung-Soon;Lee, Tae-Hoon;Moon, Seung-Jae;Lee, Jae-Heon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.642-647
    • /
    • 2008
  • The boiler structure is determined by combustion characteristics and construction costs in the combustion chamber of a large commercial boiler. The heat transfer in boiler is composed of the radiation and the convection. The convective heat transfer has happened to back-pass heating surface. The combustion gas sequentially passes through the reheater tube, 1st economizer tube, and 2nd economizer tube. In case of being lowered in boiler height, we have to install additional tube bundle in back-pass heating surface for increasing the heat transfer of boiler, which causes the noise and vibration from combustion gas. When the combustion gas passes through the back-pass tube bundle in specified load of commercial boiler, this paper analyzes the acoustic characteristics between vortex-shedding frequency and natural frequency in tube bundle cavity. The case study reduce the resonance by changing natural frequency characteristics of tube-bundle cavity using a way to install ant-noise baffle in the direction of combustion gas flow.

  • PDF

Flow Visualization by Light Emission in the Post-chamber of Hybrid Rocket (광도측정에 의한 하이브리드 로켓 후연소실의 유동 가시화)

  • Park, Kyung-su;Choi, Go Eun;Lee, Changjin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.8
    • /
    • pp.677-683
    • /
    • 2015
  • Hybrid rocket combustion displays low frequency instability(LFI, 10~30Hz) at a certain condition. Vortex shedding in the post-chamber is suspected to cause the occurrence of LFI. This study focused on the visualization of flow image using light emissions from high temperature combustion gas. Results shows that combustion pressure oscillates at a frequency of about 18 Hz, which is in phase with oscillations of light emission. Since LFI is not a property of thermo-acoustic instability, this result suggested there exists a physical coupling of pressure fluctuations with light emissions proportional to chemical reaction. Also POD analysis shows that dominant symmetric spatial modes in the stable combustion shift suddenly into asymmetric spatial pattern with the appearance of LFI. Especially, the appearance of mode 3 is a typical change of flow dynamics in unstable combustion representing a rotational fluid motions associated with vortex shedding.

Visualization of Vortex Lock-on to Oscillatory Incident Flow in the Cylinder Wake Using Time-Resolved PIV (고속 PIV계측에 의한 실린더 근접후류 공진 유동 가시화)

  • 송치성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1353-1361
    • /
    • 2001
  • Vortex lock-on or resonance behind a circular cylinder is visualized using a time-resolved PW when a single frequency oscillation is superimposed on the mean incident velocity. For vector processing, a cross-correlation algorithm in conjunction with a recursive correlation and interrogation window shifting techniques is used. Measurements are made of the Karmas and streamwise vertices in the wake-transition regime at Reynolds lumber 360. When lock-on occurs, the vortex shedding frequency is found to be half the oscillation frequency as expected from previous experiments. At the lock-on state, the Karman vortices are observed to be more disordered by the increased strength and spanwise wavelength of the streamwiee vortices, which lead? to a strong three-dimensional motion.

  • PDF

PPF/Adaptive PPF Control of Vortex-induced Vibration of Composite Beam with Rigid Cylinder (PPF/Adaptive PPF 제어기를 이용한 실린더를 부착한 복합재 보의 와류 유발 진동 제어)

  • Chang, Young-Hwan;Kim, Do-Hyung;Yang, Seung-Man;Park, Ki-Yeon;Rew, Keun-Ho;Lee, In
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.147-150
    • /
    • 2002
  • For lightweight and flexible structures, it is important to suppress the vibrations induced by interactions between fluid and structures. This paper presents the PPF/Adaptive control of the vortex-induced vibration of composite beam with rigid cylinder in which the fluid force is considered as an external excitation on the structure. For the problems considered here, the excitation frequency (vortex-shedding frequency) is assumed to be equal to the natural frequency of the structure. A pair of piezoceramic devices attached bottom of the composite structure was used as actuators. Simulation and experiment were carried out with the designed controller and effectiveness of the PPF/Adaptive PPF control was verified by both experimental and simulation results.

  • PDF