• 제목/요약/키워드: Shear strength of masonry

검색결과 62건 처리시간 0.019초

New metal connectors developed to improve the shear strength of stone masonry walls

  • Karabork, Turan;Kocak, Yilmaz
    • Structural Engineering and Mechanics
    • /
    • 제50권1호
    • /
    • pp.121-135
    • /
    • 2014
  • Stone masonry structures are widely used around the world, but they deteriorate easily, due to low shear strength capacity. Many techniques have been developed to increase the shear strength of stone masonry constructions. The aim of this experimental study was to investigate the performance of stone masonry walls strengthened by metal connectors as an alternative shear reinforcement technique. For this purpose, three new metal connector (clamp) types were developed. The shear strength of the walls was improved by applying these clamps to stone masonry walls. Ten stone masonry walls were structurally tested in diagonal compression. Various parameters regarding the in-plane behavior of strengthening stone masonry walls, including shear strength, failure modes, maximum drift, ductility, and shear modulus, were investigated. Experimentally obtained shear strengths were confirmed by empirical equations. The results of the study suggest that the new clamps developed for the study effectively increased the levels of shear strength and ductility of masonry constructions.

조적채움벽의 전단강도에 따른 채움벽골조의 내진성능 (Relation between Shear Strength of Masonry infills and Seismic Performance of Masonry-infilled Frames)

  • 유은종;김민재;이상현;김충만
    • 한국지진공학회논문집
    • /
    • 제19권4호
    • /
    • pp.173-181
    • /
    • 2015
  • In this study, material tests were performed on the masonry specimens constructed with bricks and mortar used in Korea. The specimens included two types of thickness(0.5B and 1.0B) and physical conditions (good and poor). It was shown that 1.0B specimens have 3.2~1.8 times larger shear strength than 0.5B specimens and shear strength of specimens in poor condition was 66%~38% of those in good condition. Average shear stress of masonry-infills was calculated from previous experimental studies, and relationships with failure mode, material strength of masonry, aspect ratio, and frame-to-infill strength ratio were investigated. In addition, the effects of masonry strength on the seismic performance of a masonry-infilled frame was studied using a simple example building. It can be seen that the obtained average shear stress were considerably higher than the default masonry shear strength recommended by the ASCE 41, and low values the strength of masonry does not guarantee conservative evaluation results due to the early shear failure of frame members.

Shear performance of AAC masonry triplets strengthened by reinforcing steel wire mesh in the bed and bed-head joint

  • Richard Badonbok Lyngkhoi;Teiborlang Warjri;Comingstarful Marthong
    • Earthquakes and Structures
    • /
    • 제25권3호
    • /
    • pp.149-160
    • /
    • 2023
  • Over the course of the last 4-5 years, India's northeastern region have widely used Autoclaved Aerated Concrete (AAC) blocks to construct load-bearing masonry structures. The aim of this investigation is to examine the shear characteristics of AAC masonry triplet assemblage strengthened by using two techniques, i.e., the bead joint (BJ) and the bed-head joint (BHJ) technique. Three unique variations of wire mesh were involved in the strengthening method. Furthermore, three strengthening configurations were used to strengthen each of the three wire mesh variations and the two-strengthening method, i.e. (-), L and (Z) configuration. The unreinforced and reinforced triplet masonry wallets were tested under direct shear test. From the results obtained, the 'BJ'triplet masonry wallets observed an enhanced in shear strength of about 2.23% to 23.33 % whereas the 'BHJ' triplet masonry wallets observed an enhanced in shear strength of about 22.92% to 50.69%. The "BHJ" strengthening method effectively enhance the shear strength of the triplet masonry wallets compared to the "BJ" and the "UR" wallets with an increase in capacity as the wire mesh strength increases. Furthermore, in terms of the strengthening configuration, the (Z) configuration performs better, followed by the (L) and (-) configuration demonstrating the strengthening configuration effectiveness.

Investigation of rate dependent shear bond properties of concrete masonry mortar joints under high-rate loading

  • John E. Hatfield;Genevieve L. Pezzola;John M. Hoemann;James S. Davidson
    • Computers and Concrete
    • /
    • 제33권5호
    • /
    • pp.519-533
    • /
    • 2024
  • Many materials including cementitious concrete-type materials undergo material property changes during high-rate loading. There is a wealth of research regarding this phenomenon for concrete in compression and tension. However, there is minimal knowledge about how mortar material used in concrete masonry unit (CMU) construction behaves in high-rate shear loading. A series of experiments was conducted to examine the bond strength of mortar bonded to CMU units under high-rate shear loading. A novel experimental setup using a shock tube and dynamic ram were used to load specially constructed shear triplets in a double lap shear configuration with no pre-compression. The Finite Element Method was leveraged in conjunction with data from the experimental investigation to establish if the shear bond between concrete masonry units and mortar exhibits any rate dependency. An increase in shear bond strength was observed when loaded at a high strain rate. This data indicates that the CMU-mortar bond exhibits a rate dependent strength change and illustrates the need for further study of the CMU-mortar interface characteristics at high strain rates.

Shear behaviour of AAC masonry reinforced by incorporating steel wire mesh within the masonry bed and bed-head joint

  • Richard B. Lyngkhoi;Teiborlang Warjri;Comingstarful Marthong
    • Earthquakes and Structures
    • /
    • 제26권5호
    • /
    • pp.363-382
    • /
    • 2024
  • In India's north-eastern region, low-strength autoclaved aerated concrete (AAC) blocks are widely used for constructing masonry structures, making them susceptible to lateral forces due to their low tensile and shear strengths and brittleness nature. The absence of earthquake-resistant attributes further compromises their resilience during seismic events. An economically viable solution to enhance the structural integrity of these masonry structures involves integrating steel wire mesh within the masonry mortar joints. This study investigates the in-plane shear behaviour of AAC masonry by employing two approaches: incorporating steel wire mesh within the masonry bed joint "BJ" and the masonry bed and head joint "BHJ". These approaches aim to augment strength and ductility, potentially serving as earthquake-resistant attributes in masonry structures. Three distinct variations of steel wire mesh and three reinforcing arrangements, i.e. (-), (L) and (Z) arrangement were employed to reinforce the two approaches. The test result reveals a significant enhancement in structural performance upon inclusion of steel wire mesh in both reinforcing approaches, with the "BHJ" approach outperforming the "BJ" approach and the unreinforced masonry, along with increase in capacity as the wire mesh size increases. Furthermore, the effectiveness of the reinforcing arrangement is ranked with the (Z) arrangement showing the largest performance, followed by the (L) and (-) arrangement.

Experimental investigation of the shear strength of hollow brick unreinforced masonry walls retrofitted with TRM system

  • Thomoglou, Athanasia K.;Karabinis, Athanasios I.
    • Earthquakes and Structures
    • /
    • 제22권4호
    • /
    • pp.355-372
    • /
    • 2022
  • The study is part of an experimental program on full-scale Un-Reinforced Masonry (URM) wall panels strengthened with Textile reinforced mortars (TRM). Eight brick walls (two with and five without central opening), were tested under the diagonal tension (shear) test method in order to investigate the strengthening system effectiveness on the in-plane behaviour of the walls. All the URM panels consist of the innovative components, named "Orthoblock K300 bricks" with vertical holes and a thin layer mortar. Both of them have great capacity and easy application and can be constructed much more rapidly than the traditional bricks and mortars, increasing productivity, as well as the compressive strength of the masonry walls. Several parameters pertaining to the in-plane shear behaviour of the retrofitted panels were investigated, including shear capacity, failure modes, the number of layers of the external TRM jacket, and the existence of the central opening of the wall. For both the control and retrofitted panels, the experimental shear capacity and failure mode were compared with the predictions of existing prediction models (ACI 2013, TA 2000, Triantafillou 1998, Triantafillou 2016, CNR 2018, CNR 2013, Eurocode 6, Eurocode 8, Thomoglou et al. 2020). The experimental work allowed an evaluation of the shear performance in the case of the bidirectional textile (TRM) system applied on the URM walls. The results have shown that some analytical models present a better accuracy in predicting the shear resistance of all the strengthened masonry walls with TRM systems which can be used in design guidelines for reliable predictions.

내진보강된 치장조적벽의 파괴특성과 전단강도 (Shear Strength and Failure Mode of Architectural Masonry Walls)

  • 진희종;한상환;박영미
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.89-92
    • /
    • 2008
  • 본 연구는 조적조로 구성된 치장벽체의 전단거동에 관한 연구이다. 치장조적벽체의 내진보강상 세를 소개하였으며, 본 연구에서 개발한 내진상세를 적용하여 전단거동을 평가하였다. 실험체는 비보 강조적벽(URM) 1개 보강조적벽(RM) 3개로 구성하였으며, 준정적 실험을 수행하였다. 비보강 조적벽은 형상비와 축방향 압축력에 따라 다양한 거동 및 파괴가 일어난다. 그러나 본 연구는 조적구조와는 다른 치장조적조를 대상으로 하였으므로, 전단강도의 주요변수로 작용하는 축방향 압축력은 변수에서 제외 되었다. 실험변수로는 벽체의 보강유무와 형상비로 정하였다. 실험결과 실험체의 거동은 강체회전(Rocking)모드가 지배적으로 나타났으나, 최종파괴는 여러 파괴모드가 복합적으로 나타났다. FEMA273 에서는 면내조적벽의 전단강도식을 제시한다. 강도식은 조적벽의 거동모드에 따라 4가지로 분류되며, 그 거동모드는 강체회전(Rocking), 단부압괴(Toe-Crushing), 수평줄눈미끄러짐(Bed-Joint-Sliding), 사인장(Diagonal-Tension)파괴로 나타내고 있다. FEMA 273에 의해 전단강도를 평가한 결과 치장조적벽의 거동모드는 어느정도 예측 할 수 있었지만, 전단강도는 매우 다르게 나타났다.

  • PDF

Enhanced macro element for nonlinear analysis of masonry infilled RC frame structures

  • Mebarek Khelfi;Fouad Kehila
    • Earthquakes and Structures
    • /
    • 제25권3호
    • /
    • pp.177-186
    • /
    • 2023
  • Reinforced concrete frames with a masonry infill panel is a structural typology frequently used worldwide. In seismic cases, the interaction between the masonry infill and the RC frames constitutes one of the most complex subjects in earthquake engineering. In this work, an enhancement of an existing numerical model is proposed to improve the estimation of lateral strength and stiffness of masonry-infilled frame structures and predict their probable failure modes. The proposed improvement is based on attributing corrective coefficients to the shear strength of each diagonal shear spring of the macro element, which simulates the masonry infill. The improved numerical model is validated by comparing the results with those of the original numerical model and with experimental results available in the literature. The enhanced macro element model can be used as a powerful, accessible tool for assessing the capacity and stiffness of masonry-infilled frame structures and predicting their probable failure modes.

조적벽의 전단강도를 고려한 철근콘크리트골조의 비탄성 거동 (Inelastic Behavior of Reinforced Concrete Frame Structure with Shear Strength of Masonry Wall)

  • 윤태호;강경수
    • 한국산학기술학회논문지
    • /
    • 제12권9호
    • /
    • pp.4216-4222
    • /
    • 2011
  • 본 연구는 조적 끼움벽을 고려하지 않은 기존 학교건물의 비탄성 거동과 조적 끼움벽을 고려한 기존 학교 건물의 거동특성을 비교 검토하였다. 해석 결과와 실험 결과를 비교했을 때 하중-변위 곡선과 소성힌지 분포상태에서 유사함을 확인할 수 있었다. 따라서 조적 끼움벽을 고려한 비선형 정적해석의 유효성을 검증하였다. 골조내부가 전부 조적벽으로 채워진 경우 조적벽체의 영향에 의하여 초기 강성과 강도가 증가하고 항복 전까지는 근사한 거동을 보여주며 항복이후에는 변형이 커질수록 오차가 증가하며, 골조높이의 2/3 높이가 조적벽으로 채워진 경우 초기 강성과 항복강도가 단순골조에 비하여 약간 크게 나타나고 있으며, 조적벽체의 균열이 발생한 이후에는 급격히 강도가 저하되고 있다. 골조높이의 1/3 높이가 조적벽으로 채워진 경우 초기 강성과 항복강도가 단순골조와 비슷하며 항복점은 오히려 단순 골조의 항복점보다 저하되나, 최대강도는 단순 골조와 유사하다. Pushover 해석에 의한 하중-변위 관계곡선과 실제 실험에 의한 하중-변위 관계곡선을 비교해 보면 항복 전까지는 근사한 거동을 보여주며 항복이후에는 변형이 커질수록 오차가 증가하나 실제 구조물에서는 변형의 한계가 존재하므로 해석모델로서 유용하게 사용할 수 있다.

줄눈 보강을 통한 면내 방향의 조적조 사인장 전단강도 평가 (Shear Strength Evaluation in Masonry Assemblages by Reinforcing Materials in Joint)

  • 우종훈;신경재;이준섭;한승윤
    • 대한건축학회논문집:구조계
    • /
    • 제35권9호
    • /
    • pp.191-198
    • /
    • 2019
  • All over the Republic of Korea, there are many masonry buildings which have been built since 1970s. When the earthquake at Po-Hang occurred, this is the main cause of huge damage because the masonry buildings have not seismic capacity. When masonry buildings are failed, two type of the failure modes can be shown, which are in-plane mode and out-plane mode. In-plane mode can have seismic capacity in masonry so diagonal shear test is performed in this study. The purpose of this study was to find the best way to reinforce the materials through the diagonal shear test. Through the test, shear stress and shear modulus of elasticity will be calculated, referred to the ASTM E 519-02. The variables in this test are ${\phi}3$ wire, three types of wire meshes, polypropylene strap and different types of brick. Each variable is applied to the same condition of the $1.2m{\times}1.2m$ masonry walls which are made by ASTM E 519-02. Compared to each variable with shear stress and shear modulus of elasticity, the best way of reinforcing method to have seismic capacity will be proved in this study.