• Title/Summary/Keyword: Shear Strength Evaluation

Search Result 745, Processing Time 0.028 seconds

Evaluation of horizontal shear strength of the shear connectors between precast decks and PSC girders (프리캐스트 바닥판과 PSC 거더 전단연결재의 수평전단강도 평가)

  • Hyun, Byung-Hak;Chung, Chul-Hun;Shim, Chang-Su;Kim, Yung-Jin;Lee, Han-Joo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.240-243
    • /
    • 2004
  • A new shear connection for the application of precast decks to PSC girders was proposed and push-off tests were conducted to evaluate the horizontal shear strength of the shear connection. Major parameters of the tests were connector type, shank area, vertical load, surface condition and bedding height. Judging from the test results, shear strength of the suggested shear connection was proportional to the shank area and yield strength of the connectors and was in inverse proportion to the bedding height. Shear connection with shear key at the surface showed better performance. An empirical equation for the evaluation of the shear strength of the shear connection without considering bond strength was proposed and it showed good correlation with the test results.

  • PDF

An Experimental study on the bonding shear performance evaluation of UHPC accordance with adhesion surface treatment (콜드조인트 계면 처리방법에 따른 초고성능 콘크리트의 전단접착성능에 관한 실험적 연구)

  • Kim, Min-Seong;Lee, Seung-Yup;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.86-87
    • /
    • 2015
  • An active study on UHPC, which has been recently used in high-rise building and bridges, is in progress. However, research on bonding shear strength of UHPC is required to be studied due to the lack of information. In this study, experimental research progress for bonding shear strength (shear strength of adhesive surface) evaluation of UHPC (Ultra High Performance Concrete) is proceeded. First, specimens that surface treatment methods of concrete bonded section and retardation time of placement are considered are produced. Second, Direct Shear test is applied on concrete bonded section of UHPC. As a result of this study, the highest bonding shear strength specimen in which compared to the non-retardation time specimen is compaction turbulence treatment. From later study, it is judged that strength of UHPC in accordance with direction of steel fiber when steel fiber of UHPC is mixed.

  • PDF

Shear Strength and Deformability of HSC Shear Walls (고강도 콘크리트 전단벽의 강도와 변형능력)

  • 윤현도;최창식;오영훈;이훈희
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.925-930
    • /
    • 2003
  • Provisions for ACI 318-02 and NZS 3101 pertaining to shear design of shear walls evaluated the applicability of high-strength, concrete shear walls subjected to lateral loads. Results of 73 tests of reinforced concrete shear walls were reviewed. Evaluation of test results conducted in Korea, England, America, Japan, and Australia for low-aspect ratio walls indicates that the nominal unit shear strength($\phi$=1.0) calculated using the provisions of ACI and NZS does not represent the observed shear strength well. Based on the limited database considered in this study, a reasonable lower bound to the shear strength of high-strength concrete shear walls is found to be $\sqrt[0.4]{f_{cu}}$ MPa. Similar to that of normal strength concrete walls, the rate of increase of the measured shear strength with $$\rho$_n/ㆍf_y$ is less than 1.0. Therefore, the rate of increase of shear strength attributable to the web reinforcement in shear walls appears to be overestimated by the modified truss analogy.

  • PDF

Structural Safety Evaluation for Static Strength of Thin Plate RC Member with High Strength Concrete (고강도 콘크리트를 적용한 얇은 RC 판부재의 정적 강도 안전성 평가)

  • Hwang, Hoon-Hee;Park, Sung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.69-75
    • /
    • 2017
  • Structural safety evaluation for static strength of thin plate RC member with high strength concrete is conducted in this study. Static strengths were predicted and compared with the experimental values. Predicted values were calculated by the evaluation formula based on the punching shear behavior and the yield line theory which can appear in the plate members. Static load tests were carried out for the specimens with high strength concrete and the test results were compared with the required performance in design. The comparison results show that the specimens with high strength concrete have sufficient structural safety for flexural and punching shear performance required in design. High strength concrete specimens exhibited excellent strength despite their small thickness. The range of concrete strengths applied in this study was about 60 MPa to 100 MPa.

Shear Capacity Determination of Steel Fiber Reinforced RC Columns (강섬유 보강 RC 기둥의 전단능력 산정)

  • 이현호;장극관
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.891-896
    • /
    • 2001
  • As composite materials, the addition of steel fiber in concrete significantly improves the engineering properties of structural members, notably shear strength and ductility, In this study, shear capacity evaluation method according to steel fiber contents was proposed from the literature surveys and member tests. For this, previously proposed five shear strength equation were examined and evaluated by maximum shear strength and shear capacity ratio. From the parametric study and regression analysis, following conclusion can be made; the maximum shear strength of steel fiber reinforced column will be estimated by relative shear capacity ratio.

  • PDF

Strength Evaluation of Adhesive Bonded Joint for Light Weight Structure by Single-Lab Joint Test (단면 겹치기 이음 시험에 의한 경량구조물용 접착 이음강도의 평가)

  • 이강용;김준범;최홍섭;우형표
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.2
    • /
    • pp.87-93
    • /
    • 1997
  • The bonding strength evaluation of light weight materials for electrical vehicle applications has been performed through single lap joint tests in which the design parameters such as fillet, joint style, adherend, bonding overlap length,bonding thickness, and environmental condition(soaking time in $25^{\circ}C$ water) are considered. It is experimentally oberved that lap shear strength of joint increases for higher fillet height, longer overlap length, and thinner bonding layer thickness. Al-Al adherend combination shows much higher lap shear strength than AL-FRP and FRP-FRP adherend combinations. Riveting at adhesive bonded joint of AL-AL adherend combination makes lap shear strength decrease. Effect of soaking time on lap shear strength is negligible.

  • PDF

Performance based evaluation of RC coupled shear wall system with steel coupling beam

  • Bengar, Habib Akbarzadeh;Aski, Roja Mohammadalipour
    • Steel and Composite Structures
    • /
    • v.20 no.2
    • /
    • pp.337-355
    • /
    • 2016
  • Steel coupling beam in reinforced concrete (RC) coupled shear wall system is a proper substitute for deep concrete coupling beam. Previous studies have shown that RC coupled walls with steel or concrete coupling beam designed with strength-based design approach, may not guarantee a ductile behavior of a coupled shear wall system. Therefore, seismic performance evaluation of RC coupled shear wall with steel or concrete coupling beam designed based on a strength-based design approach is essential. In this paper first, buildings with 7, 14 and 21 stories containing RC coupled shear wall system with concrete and steel coupling beams were designed with strength-based design approach, then performance level of these buildings were evaluated under two spectrum; Design Basis Earthquake (DBE) and Maximum Considered Earthquake (MCE). The performance level of LS and CP of all buildings were satisfied under DBE and MCE respectively. In spite of the steel coupling beam, concrete coupling beam in RC coupled shear wall acts like a fuse under strong ground motion.

Relationship Between Stiffness And Shear Strength of Normally Consolidated Clays (정규압밀점토의 강성도와 전단강도의 상관관계)

  • Park, Chi-Won;Park, Dong-Sun;Mok, Young-Jin
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.402-413
    • /
    • 2006
  • Strength evaluation of soft soils is a formidable task because of difficulties in sampling, specimen preparation and setting in triaxial cells. In undrained triaxial testing, sampling disturbance, verticality of specimen and bedding effect give a great influence on shear strength measurements. In the other hand, shear wave measurements of specimens are less influenced by these factors. In this research, the bender elements were attached top cap and base pedestal of triaxial cell and shear wave velocities were measured. To initiate a methodology to evaluate shear strength indirectly by measuring shear wave velocity, a relationship between shear strength and shear wave velocity was developed with kaolinite specimens consolidated in the laboratory. Undrained shear strength turns out to increase linearly with shear wave velocity. Stress-strain curves can also be predicted with a hyperbolic model and shear wave measurements.

  • PDF

An Experimental Study on the Evaluation of Shear Performance of PVA Fiber Reinforced RC Deep Beam with High Strength Headed Rebar

  • Kim, Seunghun;Lee, Kyuseon;Lee, Yongtaeg
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.109-115
    • /
    • 2017
  • This study is done to evaluate how existence of shear-span ratio and shear reinforcing bar effects on shear performance from through shear experiment using PVA fiber reinforced ferroconcrete building. Ratio of shear-span was set 1, 1.7, and arrangement of shear reinforcing bar was set with KCI2012 regulation. In result, subject with less shear-span ratio, and shear reinforcing bar with arrangement of bar shows high stiffness. Subjects with high shear-span ratio show large difference depending on existence of shear reinforcing bar. Therefore, theoretical shear strength followed by CEB code underestimates experimental shear strength by 43.9%. Shear strength of the deep beam with headed bars is more affected by the bearing strength of head than the bond strength of bar.

Shear Strength of R/C Shear Walls with Openings (개구부를 갖는 전단벽의 전단강도)

  • 윤현도;최창식;황선경;한병찬;박완신
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.223-228
    • /
    • 2003
  • Results of 61 framed reinforced concrete shear walls with openings were reviewed to evaluate the current design provisions for nominal shear strength. Provisions for ACI 318-02 and AIJ Code pertaining to shear design of shear walls evaluated the applicability of shear walls with openings subjected to lateral and vertical loads. Evaluation of test results indicates that the nominal unit shear strength($\Psi$=1.0) calculated using the provisions of ACI and AIJ does not represent the observed shear strength well. Based on the limited database considered in this study, A reasonable lower bound to the shear strength of high-strength concrete shear walls is found to be $1.09\sqrt{f_{cu}}$ kgf/$\textrm{cm}^2$.

  • PDF