Adhesion of clay to metal surface; Normal and tangential measurement

  • Basmenj, Amir Khabbazi;Ghafoori, Mohammad;Cheshomi, Akbar;Azandariani, Younes Karami
    • Geomechanics and Engineering
    • /
    • 제10권2호
    • /
    • pp.125-135
    • /
    • 2016
  • Adhesion in geotechnical engineering is the interaction between cohesive soil and a solid surface which can cause clogging in mechanized tunnelling through clayey formations. Normal piston pull out and modified direct shear tests were performed on clayey soil samples to determine which type of adhesion stress, normal or tangential, could be most effectively measured. Measured values for normal adhesion ranged from 0.9 to 18 kPa. The range of tangential adhesion was 2.4 to 10 kPa. The results indicate normal adhesion results were more accurate than those for the modified direct shear test that measure tangential adhesion. Direct shear test on identical samples did not show any correlation between measured cohesion and normal adhesion values. Normal adhesion values have shown significantly meaningful variation with consistency index and so are compatible with the base of field clogging assessment criteria. But tangential adhesion and cohesion were not compatible with these assessment criteria.

타일 시멘트 전단접착강도와 인장부착강도 비교 및 인발부착강도 타일커팅 영향에 관한 실험적 평가 (Comparison between Shear and Tensile Adhesion Strength of Cement for Ceramic Tiles and an Experimental Evaluation on the Cutting Effect of Tile for Tensile Adhesion Strength)

  • 이상현;기전도;조홈범;김영선;문형재;전현수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.181-182
    • /
    • 2021
  • Selecting a proper tile cement for ceramic tile is important to secure tile construction quality. But there is some ambiguity in standards about evaluating adhesion test such as using KS L 1593 in Lab test but using KS L 1592 in site. So, this study aims to how to select proper tile cement for securing adhesion strength in site considering both tensile and shear adhesion strength of cement for ceramic tile. Also, when doing tensile adhesion test in site, there may be adhesion drop because of cutting tile with grinder. As a result, drop of adhesion strength is about 9% ans quality manager consider these factor and should select proper tile cement.

  • PDF

고밀도 폴리에틸렌으로 접착한 합판의 접착성질과 해부학적 관찰 (Adhesion Characteristics and Anatomic Scanning of Plywood Bonded by High Density Polyethylene)

  • 한기선;이화형
    • Journal of the Korean Wood Science and Technology
    • /
    • 제25권3호
    • /
    • pp.16-23
    • /
    • 1997
  • This study was carried out to discuss feasibility of high density polyethylene(HDPE) as a new substitute for the conventional adhesives in plywood manufacture. Plywood was composed of radiata pine(Pinus radiata) and Malas(Homallium feotidium) veneers and bonded by HDPE. Adhesion characteristics and anatomical scanning has been examined through tensile-shear strength test and scanning electron microscopy(SEM). The results are as follows; 1. Optimum loading quantity was 15g/$(30.3{\times}30.3)cm^2$, and tensile-shear strength increased with the increase of loading quantity. 2. Even at the hot pressing time of 1 minute, tensile-shear strength met the value of KS(over the 7.5kgf/$cm^2$), and tensile-shear strength increased with the increase of hot pressing time. 3. Plywood composed of veneer at moisture content of 19.6% showed similar tensile-shear strength to that at air conditioned moisture content of 11.4%. 4. Under the same condition of hot pressing time, tensile-shear strength of plywood bonded by HDPE met the KS value of boil and wet test and proved the same group as phenol formaldehyde adhesive. 5. HDPE films showed mechanical adhesion through penetration into the lathe check and ray of veneer.

  • PDF

촉각센싱기반 거칠고 젖은 표면 파지가 가능한 생체모사 로봇용 그리핑 기술 개발 (Development of Bioinspired Robotic Gripping Technology for Gripping Rough & Wet Surfaces based on Tactile Sensing)

  • 김다완
    • 로봇학회논문지
    • /
    • 제17권3호
    • /
    • pp.282-287
    • /
    • 2022
  • High shear adhesion on wet and rough surfaces and tactile feedback of gripping forces are highly important for realizing robotic gripper systems. Here, we propose a bioinspired robotic gripper with highly shear adhesion and sensitive pressure sensor for tactile feedback systems. To achieve them, we fabricated multi-walled carbon nanotube sensing layer on a thin polymeric adhesive layer of polydimethylsiloxane. With densely hexagonal-packed microstructures, the pressure sensor achieved 9 times the sensing property of a sensor without microstructures. We then assembled hexagonal microstructures inspired by the toe pads of a tree frog, giving strong shear adhesion under both dry and wet surfaces such as silicon (42 kPa for dry and ~30 kPa for underwater conditions) without chemical-residues after detachment. Our robotic gripper can prevent damage to weak or smooth surfaces that can be damaged at low pressure through pressure signal feedback suggesting a variety of robotic applications.

단일겹치기이음시험을 이용한 합금화용융아연코팅강판의 코팅층 접합강도 평가 (Estimations of the Adhesion Strength of Galvannealed Coatings on Coated Sheet Using Single Lap-Shear Test)

  • 이정민;이찬주;고대철;이선봉;김병민
    • 대한기계학회논문집A
    • /
    • 제33권6호
    • /
    • pp.560-567
    • /
    • 2009
  • This paper was designed to estimate the adhesion strength of galvannealed coatings on steel sheets. The adhesion strength were evaluated using single lap - shear tests where the lap joint was bonded by structural adhesive. Tests were performed for overlap length of 5mm, 10mm and 15 mm and three directions (0, 45, 90) of steel sheets used as the adherend of the overlap joint. After the tests, FE simulations of the single lap-shear test were also carried out to observe the stress distribution in the interface between the adhesive and the coated sheet. The results showed that the joint failure loads obtained from the tensile tests of bonded single lap-joints were the same, regardless of overlap lengths and directions of steel sheets. Also, the failure of galvannealed coatings greatly depended on shear stress distribution in the interface and the value was about 30MPa.

멜라민 첨가 순서에 따른 UMF 접착제의 경화거동과 접착력의 영향 (Curing Behavior and Adhesion Performance of Urea-Melamine-Formaldehyde (UMF) Resin by Staged Addition of Melamine)

  • ;엄영근;이영규;임동혁;이병호;김현중
    • 접착 및 계면
    • /
    • 제10권2호
    • /
    • pp.84-89
    • /
    • 2009
  • The objective of this research was to investigate the curing behavior and adhesion performance of urea-melamine-formaldehyde (UMF) resin for the four types of UMF-1, UMF-2, UMF-3, and UMF-4 which synthesized by the staged addition of melamine. Also, various network structures of these resin types were discussed based on their different curing behavior and adhesion performance. The curing behavior was evaluated by DMTA and thermal stability was checked by TGA. Adhesion performance was evaluated by dry and wet shear strengths and the pH value of each cured resin was checked to see its effect on the adhesion performance. The results indicated that the UMF-1 resin type by the addition of melamine initially with the urea and formaldehyde at the same F/(U+M) rate showed the lowest thermal stability, rigidity (${\Delta}E^{\prime}$), temperature of tan ${\delta}$ maximum ($T_{tan}\;_{\delta}$), and wet shear strength, and pH value of cured resin. In wet shear strength, however, the UMF-4 resin type appears to be slightly higher than UMF-1 resin type.

  • PDF

The Flexible Characteristic of Reversible and Robust Nanohair Fastener

  • Park, Seung-Ho;Yoon, Young-Seok;Lee, Dong-Woo;Lee, Dong-Ik;You, Kyoung-Hwan;Pang, Chang-Hyun;Suh, Kahp-Yang
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제40회 동계학술대회 초록집
    • /
    • pp.432-432
    • /
    • 2011
  • Dry adhesion caused by Nanoscale contact comes up to important scientific issue. Herein, we introduce bendable nanohairy locking fastener system with high shear strength and mechanically flexible backing. The polymeric patches like velcro are composed of an array of straight nanohairs with 100 nm diameter and $1{\mu}m$ height. To fabricate high aspect vertical nanohairs, we used UV molding method with appropriately flexible and rigid polyurethane acrylate material on PET substrate. Two identical nanohairy patches are easily merged and locked each other induced by van der Waals force. Because nanohairs can be arrayed with high density ${\sim}4{\times}10^8/cm^2$, we can obtain high shear adhesion force on flat surface (~22 N/$cm^2$). Furthermore, we can obtian nanohairy locking system with maximum shear adhesion ~48 N/$cm^2$ of curved surface due to flexibility of PET substrate. We confirm the tendency that shear adhesion force increases, as radius of curvature increases.

  • PDF

Estimation of Interfacial Adhesion through the Micromechanical Analysis of Failure Mechanisms in DLC Film

  • Jeong, Jeung-Hyun;Park, Hae-Seok;Ahn, Jeong-Hoon;Dongil Kwon
    • The Korean Journal of Ceramics
    • /
    • 제3권2호
    • /
    • pp.73-81
    • /
    • 1997
  • In this paper, it is intended to present more reproducible and quantitative method for adhesion assemssement. In scratch test, micromechanical analysis on the stress state beneath the indenter was carried out considering the additional blister field. The interface adhesion was quantified as work of adhesion through Griffith energy approach on the basis of the analyzed stress state. The work of adhesion for DLC film/WC-Co substrate calculated through the proposed analysis shows the identical value regardless of distinctly different critical loads measured with the change of film thickness and scratching speed. On the other hand, uniaxial loading was imposed on DCL film/Al substrate, developing the transverse film cracks perpendicular to loading direction. Since this film cracking behavior depends on the relative magnitude of adhesion strength to film fracture strength, the quantification of adhesion strength was given a trial through the micromechanical analysis of adhesion-dependence of film cracking patterns. The interface shear strength can be quantified from the measurement of strain $\varepsilon$s and crack spacing $\lambda$ at the cessation of film cracking.

  • PDF

로진을 이용한 천연접착제의 접착물성 (Adhesion Performances of Natural Adhesives Made by Rosin)

  • 최재훈;황현득;문제익;김현중;여환명
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권4호
    • /
    • pp.38-44
    • /
    • 2007
  • 환경문제의 대두에 따라 포름알데히드를 방산하는 접착제를 대신할 수 있도록 로진을 이용한 천연접착제를 개발하고자 한다. 경화속도와 접착물성을 향상시키기 위해 건조제의 배합에 따라 천연접착제를 제조하였다. 건조제의 배합에 따른 경화속도와 접착물성을 Texture Analyzer를 이용하여 얻어진 tack값과 single lap shear test를 통해 얻어진 접착력을 기반으로 평가하였으며, 외국에서 사용되고 있는 AURO, BioFa, Livos의 식물계 천연접착제와의 성능을 비교 분석하였다. 최적의 배합비는 Co 0.7 part, Zr 1.0 part, Ca 0.5 part, Activ8 0.1 part를 첨가하였을 때이며, 이 때의 접착력은 $93.2{\pm}19.1N/cm^2$의 수준에 도달하였다.

The Effect of Fluid Shear Stress on Endothelial Cell Adhesiveness to Modified Polyurethane Surfaces

  • Gilson Khang;Lee, Sang-Jin;Lee, Young-Moo;Lee, Jin-Ho;Lee, Hai-Bang q
    • Macromolecular Research
    • /
    • 제8권4호
    • /
    • pp.179-185
    • /
    • 2000
  • Generally vascular grafts with a relatively large inner diameter (> 5 mm) have been successfully employed for replacement in the human body. However, the use of small diameter grafts is limited, because these grafts rapidly occlude due to the thrombosis. The ideal blood-contacting surface of a prosthesis would be an endothelial cell (EC) lining, because the confluent monolayer of healthy ECs that culture natural blood vessels represents the ideal nonthrombogenic surface. For vascular graft application, the stable EC adhesion on surface under How conditions is very important. In this study, the adhesive strength of ECs attached on polymer surfaces coated with collagen type IV (Col IV), fibronectin (Fn), laminin (Ln), and treated with corona was investigated onto polyurethane (PU) films. The EC-attached PU surfaces were mounted on parallel-plate flow chambers in a How system prepared for cell adhesiveness test. Three different shear stresses (100, 150, and 200 dyne/㎠) were applied to the How chambers and each shear stress was maintained for 120 min to investigate the effect of shear stress and surface treatment condition on the EC adhesion strength. It was observed that the EC adhesion strength on the surface-modified PU films was in the order of Ln≡Fn > Col IV > corona 》 control. More than 70% of the adhered cells were remained on surface-modified PU surface after applying the shear stress,200 dyne/㎠ for 2 hrs, whereas the cells were completely detached on the control PU surface within 10 min after applying the same shear stress. It seems that the type of adsorbed proteins and hydrophilicitv onto the PU surfaces play very important roles for cell adhesion strength.