• 제목/요약/키워드: Shape operator

검색결과 171건 처리시간 0.025초

Titanium Implant의 Removal Torque에 관한 연구 (A STUDY ON THE REMOVAL TORQUE OF TITANIUM IMPLANTS)

  • 이준석;김영수;김창회
    • 대한치과보철학회지
    • /
    • 제32권1호
    • /
    • pp.148-169
    • /
    • 1994
  • The concept of biologic attachment of load-bearing implants has developed over the past decades as an alternative to the difficulties associated with long term implantation using mechanical fixation and bone cement. The choice of implant material is also as critical an element as site preparation or insertion procedure. The properties of implants that affect host tissue responses are not limited to chemical composition alone, but also include shape, surface characteristics, site of implantation, and mechanical interaction with host tissues. Initial mechanical interlocking prevents micromotion and may be a prerequisite for direct bone apposition. A hard tightening of screws does not necessarily mean a stronger fixation and final tightening of the fixtures is dependent on the experience of the operator. Removal torque is lower than insertion torque. The purpose of this study was to investigate differences in the removal torques at the bone-implant interface of polished and sandblasted Titanium. This experiment will give insight into important factors that must be considered when interpreting in vivo screwing forces on implants during the connection of the transmucosal abutments. We evaluated the significance of different surface textures by comparison of the withdrawal forces necessary for removal of otherwise identical rough and polished implants of Titanium and also evaluated interfacial response on the light microscopic level to implant surface. And the priority of the area of insertion on osseointegration were evaluated. 9 Titanium implants - among them, 3 were for the developmental - of either a smooth or rough surface finish were inserted in the dog mandible in the right side. 3 months later Kanon Torque Gauge was used to unscrew the implants. The results were as follows : 1. No significant difference was seen in the removal torque due to variation in surface treatment, 23 Ncm for the sandblasted and 23.33 Ncm for the polished surface (p>0.05). 2. Implants in the anterior (25 Ncm) mandible showed better resistance to unscrewing in comparison to ones in the posterior (18 Ncm) region (p<0.05). 3. Developmental fixtures (22 Ncm) had similar pullout strength to the control group (p>0.05).

  • PDF

AUTOMATIC CABBAGE FEEDING, PILING, AND UNLOADING SYSTEM FOR TRACTOR IMPLEMENTED CHINESE CABBAGE HARVESTER

  • Song, K.S.;Hwang, H.;Hong, J.T.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.II
    • /
    • pp.489-497
    • /
    • 2000
  • Since Chinese cabbages weigh 3 to 5kgf and are big in size at the time of harvest, handling operations such as harvesting, loading and unloading including transportation require the highest labor demand among all other cultivation processes. Recently, though several cabbage harvesters were developed in Japan and Europe, those harvesters were not suitable for Chinese cabbages cultivated in Korea because of the size and shape. The cabbage harvester is almost meaningless without any proper cabbage piling and pallet unloading mechanism. Most harvesters developed so far adopted a sort of slide and free falling way in collecting cabbages into the pallet. Three or four labors are usually required for cleaning incoming cabbages and loading those in the pallet. Because of the required time for piling cabbages without severe damage and the required space capacity to carry empty and loaded pallets, harvesting speed should be adjusted in accordance with time required for consecutive operations. Up to now, any automatic or semi-automatic collecting device has not been developed in the world to pile cabbages on the layer one by one into the pallet in the ordered way with little damage and to unload pallet from the harvester continuously during the harvest process. To compromise system expenses and function, Semi-automatic cabbage piling and pallet unloading mechanism was devised and it required one labor. The foldable mesh pallet with a size of 1050mm x 1050mm x 1000mm and holding capacity of around 70 cabbages was utilized. The prototype for piling and unloading mechanism was composed of three parts such as feeding device, automatic piling device with retractable bellows, and pallet unloading device. Prior to developing the prototype, the geometric properties and the amount of the damage of the cabbage caused during the piling operation were investigated. Considering the height of the pallet, a series of cabbage carrying plates were mounted to the bracket chain to lift and to carry cabbages to the loading device. Indoor laboratory experiments showed that the cabbage carrying chain conveyor worked successfully. Considering the conveying speed 0.46m/sec of the pull up belt from the cabbages on the ground, the speed of cabbage carrying chain conveyor worked property in the range of 0.26m/sec to 0.36m/sec. The system allowed the operator to modify the position of cabbage slightly. Overall system worked successfully resulting into almost same capacity without severe damage to the cabbage as human did.

  • PDF

항공 LiDAR 데이터를 이용한 건물추출과 상부구조물 특성분석 및 모델링 (Utilizing Airborne LiDAR Data for Building Extraction and Superstructure Analysis for Modeling)

  • 정형섭;임새봄;이동천
    • 한국측량학회지
    • /
    • 제26권3호
    • /
    • pp.227-239
    • /
    • 2008
  • 항공 레이저 스캐닝(ALS) 시스템으로부터 획득한 LiDAR 데이터를 미용하여 3차원 객체 모델링과 지형도 제작을 위해서는 데이터의 기하학적 및 의미적인 분할과 같은 체계적인 데이터 처리가 선행되어야 한다. ALS로 부터 활용 가능한 LiDAR 데이터를 획득하기 위해서는 GPS, INS 및 레이저 스캐너 데이터의 통합이 필수적이다. 본 연구에서는 건물추출과 지붕 구조물 분할을 위해서 LiDAR 데이터를 영상화하여 디지털 영상처리 기법을 적용하였다. 영상화된 데이터를 사용하는 주요 장점 중 하나는 기존의 다양한 영상처리 알고리즘을 사용할 수 있다는 점이다. 격자화 및 정량화를 거치는 영상화 과정에서 원시 LiDAR 데이터가 한정된 밝기값으로 변환되므로 평활화 및 상세 정보의 손실이 발생될 수 있지만. 평활화된 데이터는 표면분할과 모델링에 오히려 적합하다. 건물의 경계선은 윤곽선 추출 연산자를 이용하여 정확하게 추출하였으며, 건물 모양에 적합하도록 규격화하였다. 건물 지붕의 구조물의 분할은 영역확산을 기반으로 수행하였다. 이 결과 다양한 디지털 영상처리 기법을 복합적으로 적용하여 건물추출과 지붕 구조물의 면분할이 가능함을 보여주었다. 또한 지붕의 형태를 재현하기 위한 특성정보 추출에 관한 개념적 방법을 제안하였다. 지붕 데이터를 분할하고 모델링을 위해 통계적 및 기하적 특성을 이용하였으며. 제안한 방법에 의한 시뮬레이션 결과는 지붕면을 분할하고 모델링하는데 가능함을 보여주고 있다.

신形 칩折斷具에 관한 實驗的 硏究 (제1보) (An Experimental Study on New Type Chip Brakeer(Part 1))

  • 손명환;이호철
    • 대한기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1121-1140
    • /
    • 1992
  • 본 연구에서는 부착형 칩절단구의 경사면 대신에 원고면으로 형성한 형태 칩 절단구를 고찰하고, 재래형과 비교하여 더 효과적인 칩절단구를 개발 실용화하고자 한 다. 가공법으로서는 연속칩의 처리가 가장 곤란한 선삭을, 공작물로서는 연속칩이 가장 잘 생성되는 SM 20 C의 연강을, 공구재료로서는 P계열의 초경합금을 써서 저속에 서 고속절삭속도까지 시험하였다.

Hand & rotary root canal instrument의 근관내 삭제 형태에 관한 전자현미경적 비교 (SEM EVALUATION OF THE PREPARED ROOT CANALS BY HAND AND Ni-Ti ROTARY ROOT CANAL INSTRUMENTS)

  • 오태석;박정원
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.477-486
    • /
    • 1998
  • Recently the development of rotary instrument makes it possible that in root canal treatment operator saves much more time, maintans original curved canal shape and easily prepares continuous tapered root canal. The purpose of this experiment was to examine the smoothness of the internal surface of prepared root canal and the effectiveness of debridement in prepared root canal by SEM for the comparison of hand and Ni-Ti rotary instrument. 25 extracted human teeth were access opened and # 10 K-type file was introduced into canal until it was appeared at the apical foramen. The working length was established by subtracting 0.5mm from this measurement. Group 1. The root canal preparation was done to # 30 with working length and then step-back until # 45 with K-Flexofile (Maillefer, Swiss). Group 2. Root canal preparation was done by Naviflex Ni-Ti file (Brasseler, USA) as the same technique with group 1. Group 3. Canal was prepared by Profile .04 (Maillefer, Swiss) taper until #30. Group 4. With use of Quantec (Tycom, USA) root canal was prepared from file number 1 to 8. In group 1 and 2, the root canal irrigant was NaOCl and the other groups, NaOCl and RC-prep (Premine Dental Products, USA) was used. The prepared teeth were notched with high-speed bur as bucco-lingual direction and fractured with chisel and mallet, then examined with SEM. Group 1 showed smooth internal surface. There were scratches mainly to the axial direction. Group 2 showed similar characteristics to those in group 1. Group 3 showed more smoother and linear cutting surface with bised scratches. Group 4 has the almost same characteristics group 3 and there was no difference in the file design. Ni-Ti rotary root canal instrument prepare the dentinal wall more smoother than hand instrument. The effectiveness of debridement was not fully affected by file design. The isthmus area and accessory canals of the root canal system were not prepared in any group. According to the result, hand and rotary type instrumentation techniques were effective in removal of major amount of tissue from root canal but it was not complete. In the direction of cutting movement there was difference between them.

  • PDF

디지털 복제로 만든 맞춤형 인공치로 제작한 임시의치와 임플란트 수술용 템플릿을 통한 임플란트 지지형 고정성 보철 수복 증례 (Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report)

  • 정대길;오경철;심준성;박지만
    • 대한치과보철학회지
    • /
    • 제57권4호
    • /
    • pp.397-404
    • /
    • 2019
  • 성공적인 임플란트 치료를 위해서는 식립부위의 골조직 및 연조직 상태(condition)도 중요하지만 식립 위치 또한 매우 중요하다. 잘못된 위치에 식립된 임플란트는 생물학적, 심미적, 기계적 문제점을 야기하게 된다. 올바른 위치에 임플란트를 식립하기 위해서는 최종 보철물을 고려해야 하며 이를 위해서는 진단 왁스업 과정이 필요하다. 발치 후 사용 할 임시 의치의 인공치를 진단 왁스업 형태대로 제작하면 구강내에서 진단 왁스업 형태를 평가해 볼 수 있으며, 잘 적응된 임시 의치를 복제해 제작한 임플란트 수술용 템플릿으로 계획된 위치에 임플란트를 식립하는 것이 가능하다. 본 증례에서는 진단 왁스업을 디지털 복제하여 의치용 인공치를 맞춤형으로 제작하였고, 이를 이용해 임시 의치를 제작하였다. 충분한 적응 기간을 거친 후 임시 의치를 복제하여 임플란트 수술용 템플릿을 제작한 다음, 이를 활용하여 계획된 위치에 임플란트를 식립하였다. 골유착을 위한 충분한 치유기간을 가진 다음 진단 왁스업 형태가 반영된 임플란트 지지형 고정성 보철물을 제작하였다. 최종 보철물 장착 후 6개월간의 경과 관찰 기간 동안 심미적, 기능적으로 만족할 만한 치료 결과를 보였기에 이를 보고하고자 한다.

Functionally generated path technique을 이용한 편악 피개의치 수복 증례 (Maxillary overdenture restoration using functionally generated path technique: a case report)

  • 조유경;이영후;홍성진;노관태;배아란;김형섭;권긍록;백장현
    • 대한치과보철학회지
    • /
    • 제60권1호
    • /
    • pp.55-62
    • /
    • 2022
  • 1933년 Meyer에 의해 처음 기술된 Functionally generated path (FGP) technique은 하악의 한계운동 내에서 대합치 교두에 의해 형성된 운동 경로를 구강 내에서 인기하는 방법이다. 이 방법을 이용하여 환자에게 적절한 교합 형태를 부여할 수 있는데 이 증례에서는 자연치열과 대합되는 상악 피개의치를 제작하여 균형 교합을 부여하였다. 또한 FGP technique으로 구치부 교합면을 정밀하게 형성하고 의치 치아의 마모를 감소시키기 위해 통상적으로 사용하는 기성 레진 인공치가 아닌 지르코니아 의치 치아를 개별 제작하였다. 이러한 재료와 방법으로 치료 후 술자와 환자 모두 만족스러운 결과를 얻었기에 본 증례를 보고하는 바이다.

영광 3호기 초기 시운전 동안 CPC / COLSS 관련시험 결과 분석 및 평가 (Analysis and Evaluation of CPC / COLSS Related Test Result During YGN 3 Initial Startup)

  • 지성구;유성식;인왕기;어근선;두진용;김대겸
    • Nuclear Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.877-887
    • /
    • 1995
  • 영광 3호기는 국내에서 노심보호계통으로_ 노심보호연산기 (CPC)를, 노심감시계통으로 노심운전제한 감시계통 (COLSS)을 사용하는 최초의 원자력발전소이다. CPC는 핵비등 이탈율 및 국부 설출력밀도를 실시간으로 계산하여 노심 조건이 설계 제한치를 초과하면 원자로를 정지시키도록 설계되었다. COLSS는 운전원에게 핵비등 이탈율/선형열출력 여유도, 사분출력 경사비, 및 축방향 출력편차에 대한 기술지침서의 운전제한치을 적용하는데 도움을 제공하고 운전제한치를 초과하는 경우, 경보를 제공하도록 설계되었다. 영광3호기 초기 시운전시험 동안, 다양한 노심 조건에서 CPC/COLSS의 성능을 검증하고 최적의 교정 상수를 얻기 위하여 광범위한 CPC /COLSS 관련시험이 수행되었다. 대부분의 시험결과는 시험허용 범위를 만족하였고, 시험허용 범위를 불만족한 경우에는 시험결과를 분석, 평가하여 문제점을 해결하였다. 각 시험결과를 분석, 평가한 결과 영광 3호기에서 CPC/COLSS가 설계된 데로 성공적으로 설치, 운전되는 것을 확인할 수 있었다.

  • PDF

진료자세가 고정성 국소의치의 지대치 삭제에 미치는 영향 (An influence of operator's posture on the shape of prepared tooth surfaces for fixed partial denture)

  • 원인재;권긍록;배아란;최대균
    • 대한치과보철학회지
    • /
    • 제49권1호
    • /
    • pp.38-48
    • /
    • 2011
  • 연구 목적: 본 연구는 고정성 국소의치 제작을 위한 상악 좌측 제2소구치 및 제2대구치의 지대치 삭제에 대하여 인체공학적으로 안정된 진료 자세를 확립하고, 치과의사의 일반적 작업 자세와 비교, 분석하고 인체공학적으로 안정된 자세의 임상적용 가능성을 알아보고 이를 이용하여 향후 치과의사 교육의 기초 자료로 활용하기 위함이다. 연구 재료 및 방법: 상악 좌측 고정성 국소의치를 위한 인체공학적으로 안정된 자세를 고안하고 임상 경력 3-6년의 보철과 전공의 과정에 있는 치과의사 8명을 선정하여 임의의 자세로 상악 좌측 고정성 부분의치 지대치 삭제를 시행하고 연구 대상자들에게 인체공학적으로 안정된 자세를 교육하고 연구 대상들에게 인체공학적으로 안정된 자세로 상악 좌측 고정성 국소의치 지대치 삭제를 시행하였다. 임의의 자세로 삭제 시행한 치아와 인체공학적으로 안정된 자세로 삭제 시행한 치아를 KHDP 3-dimensional measuring device를 사용하여 계측해 교합면 삭제량, 변연의 폭경, 변연의 깊이 축면 경사도. 그리고 삭제시간을 측정 비교하였다. 모든 계측된 결과를 윈도우즈용 SPSS 통계 프로그램 (ver. 18.0, SPSS, Chicago, IL, USA)을 이용하여 교합면 삭제량, 변연의 폭 및 깊이, 축면 경사도, 치아 삭제 시간을 평균값 및 표준편차 분석하고 T-test를 Random Position 와 Home Position에 따른 차이 검정하였다. 결과: 와(fossa) 부위에서의 교합면 삭제량은 상악 좌측 제2소구치 및 제2대구치 모두에서 지시삭제량에 비해 적었으며, 교두정에서의 삭제량은 지시삭제량 1.7 mm에비해 많았으나, Random position과 Home position간에 유의차는 없었다 (P > .05). 변연 폭의 삭제량은 상악 좌측 제2소구치 및 제2대구치 모두에서 지시삭제량에 비해 많았으며, Random position과 Home position간에 유의차는 없었다 (P > .05). 변연 깊이의 삭제량은 상악 좌측 제2소구치 및 제2대구치 모두에서 Random position이 Home position에 비하여 지시삭제량보다 깊었다 (P < .05). 축면경사각은 상악 좌측 제2소구치 및 제2대구치 모두에서 Home position의 축면 경사각이 Random position의 축면경사각보다 작았으나 유의차는 없었다 (P > .05). 피어슨 상관분석 결과, Random position에서 교합면 삭제량, 변연 깊이, 축면경사각은 서로에게 영향을 주고 있었으나, Home position에서는 측정결과 들이 거의 독립적으로 서로에게 영향을 주지 않았다 (P < .05). Home position 삭제 횟수가 많아질수록 삭제소요 시간은 줄어들었고, 이는 실험에 참여한 8명 모두에서 Random position 삭제시간과 비슷해지거나 더 짧았다. 결론: 고정성 국소의치를 위한 상악 좌측 제2소구치 및 제2대구치 삭제의 경우, 교합면 삭제량, 변연의 폭, 변연의 깊이, 축면 경사각에 있어서 Home position과 Random position 간에는 큰 차이가 없었다. 삭제시간, 인접치 인접면 손상 정도는 Home position이 Random position보다 적었다. 또한 자세분석을 한 결과 Home position이 Random position에 비하여 곧은 자세로 인체에 무리를 주지 않았다. 따라서 인체공학적으로 안정된 자세인 Home position의 임상적용 가능성이 높다고 생각된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF