• Title/Summary/Keyword: Shape of External Corrosion

Search Result 5, Processing Time 0.015 seconds

Effect of Shape of External Corrosion in Pipeline on Failure Prediction (외부부식의 형상이 파이프라인의 파손예측에 미치는 영향)

  • Lee, Eok-Seop;Kim, Ho-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.11 s.170
    • /
    • pp.2096-2101
    • /
    • 1999
  • This paper presents the effect of shape of external corrosion in pipeline on failure prediction by using numerical simulation. The numerical study for the pipeline failure analysis is based on the FEM(Finite Element Method) with an elastic-plastic and large-deformation analysis. The predicted failure stress assessed for the simulated corrosion defects having different corroded shapes along the pipeline axis are compared with those by methods specified in ANSl/ASME B31G code and a modified B31G code.

Effect of External Corrosion in Pipeline on Failure Prediction

  • Lee, Ouk-Sub;Kim, Ho-Jung
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.2
    • /
    • pp.48-54
    • /
    • 2000
  • This paper presents the effect of shape of external corrosion in pipeline on failure prediction by using a numerical simulation. The numerical study for the pipeline failure analysis is based on the FEM(Finite Element Method)with an elastic-plstic and large-deformation analysis. Corrosion pits and narrow corrosion grooves in pressurized pipeline were analysed. A failure criterion, based on the local stress state at the corrosion and a plastic collapse failure mechanism, is proposed. The predicted failure stress assessed for the simulated corrosion defects having different corroded shapes along the pipeline axis compared with those by methods specified in ANSI/ASME B31G code and a modified B31G code. It is concluded the corrosion geometry significantly affects the failure behavior of corroded pipeline and categorisation of pipeline corrosion should be considered in the development of new guidance for integrity assessment.

  • PDF

Corrosion Characteristics of Excavated Bronze Artifacts According to Corrosion Environment (부식 환경에 따른 출토 청동 유물의 부식 특성)

  • Jang, Junhyuk;Bae, Gowoon;Chung, Kwangyong
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.1
    • /
    • pp.24-33
    • /
    • 2020
  • In excavated bronze artifacts, corrosion products of various shapes and colors are observed due to multiple corrosion factors coexisting in the burial environment, and these corrosion products can constitute important data not only in terms of long-term corrosion-related information, but also in connection with preservation of artifacts. As such, scientific analysis is being carried out on the corrosion layer and corrosion products of bronze artifacts, and the corrosion mechanism and the characteristics of corrosion products elucidated, which is essential for interpreting the exposed burial environment and its association with corrosion factors inside the burial environment. In this study, after classifying excavated bronze artifacts according to alloy ratio and fabrication technique, comprehensive analysis of the surface of corrosion artifacts, corrosion layer, and corrosion products was carried out to investigate the corrosion mechanism, formation process of the corrosion layer, and characteristics of corrosion products. The study designated two groups according to alloy ratio and fabrication technique. In Group 1, which involved a Cu-Sn-Pb alloy and had no heat treatment, the surface was rough and external corrosion layers were formed on a part, or both sides, of the inside and the outside, and the surface was observed as being green or blue. α+δ phase selection corrosion was found in the metal and some were found to be concentrated in an empty space with a purity of 95 percent or more after α+δ phase corrosion. The Cu-Sn alloy and heat-treated Group 2 formed a smooth surface with no external corrosion layer, and a dark yellow surface was observed. In addition, no external corrosion layer was observed, unlike Group 1, and α corrosion was found inside the metal. In conclusion, it can be seen that the bronze artifacts excavated from the same site differ in various aspects, including the formation of the corrosion layer, the shape and color of the corrosion products, and the metal ion migration path, depending on the alloy ratio and fabrication technique. They also exhibited different corrosion characteristics in the same material, which means that different forms of corrosion can occur depending on the exposure environment in the burial setting. Therefore, even bronze artifacts excavated from the same site will have different corrosion characteristics depending on alloy ratio, fabrication technique, and exposure environment. The study shows one aspect of corrosion characteristics in specific areas and objects; further study of corrosion mechanisms in accordance with burial conditions will be required through analysis of the corrosive layer and corrosive product characteristics of bronze artifacts from various regions.

A Study on the Creep Characteristics according to Groove Shape of T-Welded Joint (T-Joint 용접부의 Groove형상별 크리프 특성에 관한 연구)

  • Bang, Han-Seo;Kim, Jong-Myeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.13 no.3 s.33
    • /
    • pp.68-76
    • /
    • 1999
  • The welding residual stresses produced by the welding frequently caused a crack and promote stress corrosion etc. in HAZ(heat affected zone) contained with external load and weakness of material. Therefore, PWHT(post welding heat treatment) is widely used to reduce wekdubg residuss, to relax hardening of heat affected zone and to get rid of impurity. In this study, in order to define the effect on shappes of T-welded joint, during the post welding heat treatment, we have carried out numerical analyses on the several test pieces by using computer program which was based on thermal-elasto-plato-plasto-creep theories for the study. The main results obtained form this study is as follows: 1) The mechanical difference for change the thickness of plate and groove angle did not appear. 2) The distribution modes of welding residual stresses are same on the all test specimens during the post welding heat treatment. 3) In a mecharical point of view, minimum groove groove angle($40^{circ}$) is more suitable than maximum groove angle($60^{circ}$). 4) Therefore, it is appropriate to minimize the size of groove shape in strength and safety.

  • PDF

Application of Amplitude Demodulation to Acquire High-sampling Data of Total Flux Leakage for Tendon Nondestructive Estimation (덴던 비파괴평가를 위한 Total Flux Leakage에서 높은 측정빈도의 데이터를 획득하기 위한 진폭복조의 응용)

  • Joo-Hyung Lee;Imjong Kwahk;Changbin Joh;Ji-Young Choi;Kwang-Yeun Park
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.2
    • /
    • pp.17-24
    • /
    • 2023
  • A post-processing technique for the measurement signal of a solenoid-type sensor is introduced. The solenoid-type sensor nondestructively evaluates an external tendon of prestressed concrete using the total flux leakage (TFL) method. The TFL solenoid sensor consists of primary and secondary coils. AC electricity, with the shape of a sinusoidal function, is input in the primary coil. The signal proportional to the differential of the input is induced in the secondary coil. Because the amplitude of the induced signal is proportional to the cross-sectional area of the tendon, sectional loss of the tendon caused by ruptures or corrosion can be identified by the induced signal. Therefore, it is important to extract amplitude information from the measurement signal of the TFL sensor. Previously, the amplitude was extracted using local maxima, which is the simplest way to obtain amplitude information. However, because the sampling rate is dramatically decreased by amplitude extraction using the local maxima, the previous method places many restrictions on the direction of TFL sensor development, such as applying additional signal processing and/or artificial intelligence. Meanwhile, the proposed method uses amplitude demodulation to obtain the signal amplitude from the TFL sensor, and the sampling rate of the amplitude information is same to the raw TFL sensor data. The proposed method using amplitude demodulation provides ample freedom for development by eliminating restrictions on the first coil input frequency of the TFL sensor and the speed of applying the sensor to external tension. It also maintains a high measurement sampling rate, providing advantages for utilizing additional signal processing or artificial intelligence. The proposed method was validated through experiments, and the advantages were verified through comparison with the previous method. For example, in this study the amplitudes extracted by amplitude demodulation provided a sampling rate 100 times greater than those of the previous method. There may be differences depending on the given situation and specific equipment settings; however, in most cases, extracting amplitude information using amplitude demodulation yields more satisfactory results than previous methods.