• Title/Summary/Keyword: Shape File

Search Result 156, Processing Time 0.028 seconds

THE EFFECT OF SOME CANAL PREPARATION TECHNIQUES ON THE SHAPE OF ROOT CANALS (수종의 근관형성 방법이 근관 형태에 미치는 영향)

  • Lee, Ji-Hyeon;Cho, Yong-Bum
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.2
    • /
    • pp.337-345
    • /
    • 1999
  • The purpose of this study was to compare the shape of root canal after instrumentation with some engine driven NiTi files. Thirty narrow and curved canals(15-35 degree) of mesial canals of extracted human mandibular first molars were divided into three groups. Group 1: After radicular access with Gates Glidden drill, apical shaping using step back method with Flexo file Group 2: After radicular access with Gates Glidden drill, apical shaping with Profile .04 Group 3: Canal shaping with GT file and Profile .04. Using modified Bramante technique, the root was sectioned at 2 mm from apical foramen, height of curvature, 2 mm from canal orifice. Canal centering ratio, amount of transport, amount of dentin removed, shape of canal were measured and statistical analysis is done using SPSS Program V 7.5. The results were as follows: 1. Canal centering ratio of group 3 was the lowest at coronal part, but there was no statistical difference. Centering ratio of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Centering ratio of group 2 was the lowest at apical part, but there was no statistic difference. 2. Amount of transport of group 3 was the lowest at coronal part, but there was no statistical difference. Amount of transport of group 2 was the lowest at curve part, and there was statistical difference between group 1(P<0.05). Amount of transport of group 3 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 3. Amount of dentin removed of group 3 was the lowest at coronal part, bur there was no statistical difference. Amount of dentin removed of group 2 was the lowest at curve part, but there was no statistical difference. Amount of dentin removed or group 2 was the lowest at apical part, and there was statistical difference between group 1 and group 2, group 1 and group 3(P<0.05). 4. The shape of the canals after instrumentation varied among the groups. The majority of canals at coronal and curve part for group 1 were round in shape(7 in 10), those at apical part were oval(8 in 10). The majority of canals at coronal part for group 2 were round in shape(7 in 10) and there was no difference in the number of shape at other part. There was no difference in the number of shape at every part for group 3. As above results, NiTi rotary instrumentation showed a trend to remain more centered in the canal than SS file instrumentation. At using NiTi file, coronal shaping with Gates Glidden drill was not statistically different from shaping with GT file. But shaping with GT file showed tapered canals, so it may be said that shaping with GT file is a safe and valuable instrumentation method.

  • PDF

SHAPING ABILITY OF ROOT CANAL INSTRUMENTS ON CURVED ROOT CANALS (수종 근관확대 기구의 만곡된 치근관 성형능력)

  • Kim, Myeong-Su;Son, Ho-Hyun
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.141-152
    • /
    • 1992
  • Four endodontic instruments from different manufacturers(K - file, Hedstrom - file, K - flex - file, Cavi - Endo) were used to shape 80 mesial canals of extracted posterior teeth. The instrument's ability to enlarge and shape the canals as the original canal shape was assessed by superimposing radiographs of canals obtained before and after canal shaping. The results were as follows 1. Hedstrom - file enlarged canals greater than K - file, K - flex - file, and Cavi - Endo(P<0.05). There are no differences in canal enlargement among K - flex, K - flex - file, and Cavi - Endo(P<0.05). 2. All the instruments showed no difference in canal enlargement between convex side and concave side of B point in proximal and clinical radiographic views, but at the concave side of C point canals were enlarged greater than at the convex side(proximal view of K - file: P<0.05, the others: P<0.01). 3. There was no difference m canal enlargement between convex side and concave side in proximal view of A and D points of K - file and K - flex - file(P<0.05). But in clinical view, canal enlargement at convex side of A point and concave side of D point was greater than that at concave side of A point and convex side of D point respectively. 4. Hedstrom - files showed greater canal enlargement at convex side of A points and concave side of D points (P<0.05 or P<0.01). Cavi - Endo showed no difference in canal enlargement between convex side and concave side at A and D points in proximal view(P<0.05). Bur canal enlargement was greater at concave side than at convex side of D point in clinical view. 5. K - file and Cavi - Endo showed no differences in canal enlargement between convex and concave side in proximal and clinical view (P<0.05). K - flex - file showed greater canal enlargement at concave side in proximal and clinical view(P<0.0:5). Hedstrom file showed no difference in canal enlargement between convex side and concave side in proximal view, but showed greater canal enlargement at concave side in clinical view(P<0.05).

  • PDF

AN EXPERIMENTAL STUDY ON THE SHAPE OF THE APICAL REGIONS OF ROOT CANALS AFTER INSTRUMENTATION BY VARIOUS ENLARGING INSTRUMENTS (각종(各種) 근관확대기구(根管擴大器具)에 의(依)한 근관형성(根管形成) 후(後) 근단부(根端部) 근관면(根管面)의 형태(形態)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.7 no.1
    • /
    • pp.17-24
    • /
    • 1981
  • The purpose of this study is to compare the shape of the apical regions of root canals after instrumentation by various enlarging instruments. 120 extracted, single-rooted human teeth were seperated into 4 experimental groups. Each group provided 30 teeth for experimental use. Group 1 root canals instrumented by the hand-operated Reamer. Group 2 root canals instrumented by the hand-operated H-file. Group 3 root canals instrumented by the hand-operated K-file. Group 4 root canals instrumented by the automated Giromatic file. The results were as follows: 1. The degree of the roundness of the apical regions of root canal walls: 1) Hand-operated instruments were superior to the automated Giromatic file. 2) The Reamer was the most effective instrument among hand-operated instruments 3) There was little difference between the H-file and the K-file. 2. The degree of the smoothness of the apical regions of root canal walls: 1) Root canal walls instrumented by the hand-operated Reamer, H-file and, K-file were generally smooth, and there was little difference among them. 2) Root canal walls instrumented by the automated Giromatic file showed many irregular canal walls. 3. The existance of organic debris in the apical regions of root canals: All organic debris is not removed from root canals, and there was little difference between hand-operated instruments and the automated Giromatic instrument in removing organic debris.

  • PDF

A Study on the Improvement of Form Accuracy Using the Length Strain of Rapid Prototype (쾌속조형장치의 길이오차를 이용한 형상정밀도 개선에 관한 연구)

  • Kim Tae Ho;Park Jae Duk;Kim Min Ju;Lee Seung-Soo;Lee Jun Hee;Jeon Eon-Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.154-159
    • /
    • 2004
  • This study is aimed to diminish the errors which created during transforming from 3D shape created with CAD program to STL file formation. The length strain which created on X-Y axises at STL file transforming is diminished by using the relation between common shape error and shrinkage rate. As the result of study, we have confirmed the length strain in accordance with facetres value. Also, the shape error is compensated with shrinkage rate by error of length strain. so, we could diminish to shape error by several tens micrometer.

Comparative study of two CAD software programs on consistency between custom abutment design and the output (두 가지 CAD software의 맞춤형 지대주 디자인과 출력물 일치도 비교)

  • Lim, Hyun-Mi;Lee, Kyu-Bok;Lee, Wan-Sun;Son, KeunBaDa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.3
    • /
    • pp.157-166
    • /
    • 2018
  • Purpose: This study was aimed to compare the consistency between the custom abutment design and the output in two CAD software programs. Materials and Methods: Customized abutments were designed by using 3Shape Dental System CAD software and Delta9 CAD software on a plaster model with implants (CRM STL file). After milling of the designed abutments, the abutments were scanned with a contact method scanner (Test STL file). We overlaid the Test STL file with each CRM STL file by using inspection software, and then compared the milling reproducibility by measuring the output error of the specimens from each CAD software program. Results: The Delta9 showed better milling reproducibility than 3Shape when comparing the milling errors obtained with a full scan of all specimens (P < .05) and also when comparing the axial wall region specifically according to the axial angle. With 0.9 mm marginal radius, the Delta9 showed better consistency between the design and the output than 3Shape (P < .05). While, anti-rotation form had no significant difference in error between the two systems. When cumulative errors were compared, the Delta9 showed better milling reproducibility in almost cases (P < .05). Conclusion: Delta9 showed a significantly smaller error for most of the abutment design options. This means that it is possible to facilitate generation of printouts with reliable reproducibility and high precision with respect to the planned design.

A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE (ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구)

  • Lee, Bo-Kum;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.4
    • /
    • pp.294-302
    • /
    • 2005
  • The purpose of this study was to evaluate the canal configuration after shaping by ProFile. ProTaper and K-Flexofile in simulated resin canals with different angles of curvature. Three types of instruments were used: ProFile. ProTaper. K-Flexofile. Simulated root canals. which were made of epoxy resin. were prepared by ProFile. ProTaper with rotary instrument using a crown-down pressureless technique. and hand instrumentation was performed by K-Flexofile using a step-back technique. All simulated. canals were prepared up to size 25 file at end-point of preparation. Pre and post instrumentation images were recorded with Scanner. Assessment of canal shape was completed with Image Analysis program. Measurements were made at 1. 2. 3. 4. 5. 6. 7. 8. 9 and 10mm from the apex. At each level. outer canal width. inner canal width. total canal width. and amount of transportation from original axis were recorded. Instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA analysis of variance and the Sheffe's test. The result was that ProFile and ProTaper maintain original canal shape regardless of the increase of angle of curvature than K-Flexofile. ProFile show significantly less canal transportation and maintained original canal shape better than ProTaper.

A Study on the Forming of Fine Gear Housing using Rapid Prototyping (RP를 이용한 미세기어 하우징 성형에 관한 연구)

  • Lee, Seung-Soo;Kim, Min-Ju;Park, Jeung-Bo;Jeon, Eon-Chan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.10
    • /
    • pp.1748-1753
    • /
    • 2003
  • This paper describes the forming of fine gear housing using RP system. In order to apply 3D model formed through CAD software to RP system, it is necessary of transforming 3D model into STL file format. Besides, when the same shape is formed repetitively, we must solve the program that the shape accuracy of prototype is irregular. Therefore, we will make an experiment on influence of 3D model, file transformation and prototype on facetres, AutoCAD system value. On the basis of experimental result, we will develop an automatic file transformation program for RP. In the final process, we will manufacture on a better prototype according to the experiment result of fine gear housing.

A study on conversion of cross-sectional information form STL file for Stereolithography (Stereolithography를 위한 STL파일로부터 단면정보 변환에 관한 연구)

  • 최홍태;김준안;이석희;백인환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.445-450
    • /
    • 1995
  • This paper deals with conversion from STL file to Slice cross-sectional information for Stereolithography. The STL file consist of three vertices of triangle and normal vectors in order to represent three dimension shape, but It is very difficult to convert STL file intoSlice file directly, because of file size from one Mbyte to tens of Mbytes. So, The system is accomplished data flow such as neutral.dat, .SL1, .SL2, .SL3, and .SLC file. The data processing is as follows: 1. Create a neutral file including common information. 2. Modify STL file within effective scope of SLA. 3. Calculate a point of intersection between plane equation and line equation. 4. Sort z values by increasing order. 5. Search closed loop by method of singlylinked linear list. The system is developed by using Borland C++ 3.1 compiler in the environment of Pentium PC. We get a satisfactory prototype as a result of application about a lot of household electrical appliances.

  • PDF

A Study on the Method of Extracting Shape and Attribute Information for Port IFC Viewing (항만 IFC Viewing을 위한 형상 및 속성 정보 추출 방법에 관한 연구)

  • Kim, Keun-Ho;Park, Nam-Kyu;Joo, Cheol-Beom;Kim, Sung-Hoon
    • Journal of KIBIM
    • /
    • v.11 no.3
    • /
    • pp.67-74
    • /
    • 2021
  • An IFC file is dependent on the IFC schema. Because of this relationship, most IFC-using software reads and interprets the IFC File by employing an early binding method, which uses a standard IFC schema. In the case of most open sources, early binding methods using standard IFC schema have a problem that they cannot express extra information of IFC File out of extended IFC schema. Also, in the case of previous studies, they suggested schema extension, such as adding attribute information to the schema, rather than the interpretation of IFC File. This study research on method of extracting shape and attribute information was conducted by analyzing the IFC File produced through the Port schema, which is an extended IFC schema. Three objects were created using the reference relationship between the Port schema definition and the IFC entity, and, at the end, the three objects were combined into one object. It has been confirmed that the shape and property data were express properly while delivering the combined object to the viewer. The process is possible because of the method of matching IFC schema and IFC File, which is dependent on IFC schema but not early binding method. However, this method has some drawbacks, such that contemporaneously generated many objects consume many memory spaces. Future research to investigate that issue further is needed.

A STUDY OF HISTOMORPHOLOGICAL CHANGE OF CURVED ROOT CANAL PREPARATION USING GT ROTARY FILE, PROFILE AND STAINLESS STEEL K-FILE (수종의 Engine driven NiTi file과 stainless steel K-file을 이용한 근관형성 후 근관의 조직형태학적 변화에 관한 연구)

  • Ko, Hyung-Jung;Baek, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.6
    • /
    • pp.612-621
    • /
    • 2002
  • The purpose of this study was to compare the histomorphological change of curved root canal preparation using GT rotary File, Profile .04 taper and stainless steel K-file. 45 mesial canals(over 20 degree) of extracted human mandibular first molars were mounted in resin using a modified Bramante muffle system and divided into three groups. The roots were cross-sectioned at 2.5mm 5mm and 8mm levels from apical foramen. Tracings of the canals were made from preinstrumentation pictures of the cross section. The canals were prepared using a step-back technique with stainless steel K file(group 1), Profile .04 taper rotary file(group 2) and GT rotary file(group 3). Tracings of the prepared canals were made from postinstrumentation picture. Canal centring ratio. amount of transportation, area of dentin removed and shape of canal were measured and statistically were evaluated with Student-Newman-Keuls test using Sigma Stat(Jandel Scientific Software, USA). The results were as followings : 1 Amount of transportation of group 2 was the lowest at apical part, but there was no statistical difference. The direction of transportation was the outside of curvature at apical part. 2. Centering ratio at the apical part of group 1 was the highest, and there was statistical differences between apical and middle part, apical and coronal part(p<0.05). Centering ratio at the middle part of group 3 was the lowest, and there was statistical difference between apical and middle part(p<0.05). Centering ratio of group 2 was the lowest at apical part, but there was no statistical difference. 3. Amount of dentin removed of group 1 was the highest at coronal, middle and apical part among three groups, and there was statistical difference(p<0.05). 4. The majority of the cross-sectioned canal shape after instrumentation were irregular at coronal, middle and apical part. But there are more number of round shaped canals at group 3 than other group.