• Title/Summary/Keyword: Shape Alignment

Search Result 167, Processing Time 0.029 seconds

Evaluation of Seat Comfort and Pressure Distribution According to the Ergonomic Design of Automobile Seats (자동차 시트의 인간공학적 디자인에 따른 착좌 안락감 및 압력분포 평가)

  • Halim Chung;Jun Won Choi;Seung Wan Yang;Chun Kyu Park;Do Yong Kim;Chang Hyun Song;Jong Bae Kim;Han Sung Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.157-165
    • /
    • 2023
  • The purpose of this study was to evaluate the importance of developing slim seats with ergonomic design to improve seat comfort and expand the interior space. Two seats were used for the experiment: a sample seat designed based on hip shape and spinal alignment and a normal seat with a flat design without curves. Subjects sat in both the sample seat and a normal seat applied to the vehicle simulator and the experiment was conducted. The next part of the experiment was conducted in two different postures: a driving posture and a relaxed posture. The subjects filled out a comfort questionnaire immediately after sitting and after 30 minutes. The results showed that the comfort in the sample seat was found to be more comfortable than the normal seat. However, no significant difference was noted for the relaxation posture. Pressure distribution was also recorded immediately after sitting and after 30 minutes. In the case of pressure distribution, it was confirmed that the pressure in the sample seat was more evenly distributed in both the driving and relaxed postures than in the normal seat. The results showed that the ergonomically designed sample seat greatly improved seating comfort and pressure distribution compared to the normal seat, which is a general vehicle seat design.

Gamma/neutron classification with SiPM CLYC detectors using frequency-domain analysis for embedded real-time applications

  • Ivan Rene Morales;Maria Liz Crespo;Mladen Bogovac;Andres Cicuttin;Kalliopi Kanaki;Sergio Carrato
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.745-752
    • /
    • 2024
  • A method for gamma/neutron event classification based on frequency-domain analysis for mixed radiation environments is proposed. In contrast to the traditional charge comparison method for pulse-shape discrimination, which requires baseline removal and pulse alignment, our method does not need any preprocessing of the digitized data, apart from removing saturated traces in sporadic pile-up scenarios. It also features the identification of neutron events in the detector's full energy range with a single device, from thermal neutrons to fast neutrons, including low-energy pulses, and still provides a superior figure-of-merit for classification. The proposed frequency-domain analysis consists of computing the fast Fourier transform of a triggered trace and integrating it through a simplified version of the transform magnitude components that distinguish the neutron features from those of the gamma photons. Owing to this simplification, the proposed method may be easily ported to a real-time embedded deployment based on Field-Programmable Gate Arrays or Digital Signal Processors. We target an off-the-shelf detector based on a small CLYC (Cs2LiYCl6:Ce) crystal coupled to a silicon photomultiplier with an integrated bias and preamplifier, aiming at lightweight embedded mixed radiation monitors and dosimeter applications.

The Effects of Corneal Type and Corneal Astigmatism on Tear Volume between Rigid Gas Permeable Lens and the Cornea (각막형상 및 각막난시도가 RGP렌즈와 각막사이의 눈물양에 미치는 영향)

  • Kim, Jihye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.141-150
    • /
    • 2015
  • Purpose: In the present study, a difference in tear volume between the cornea and the rigid gas permeable (RGP) lens relative to corneal shape and corneal astigmatism was investigated by the alignment fitting status of spherical and aspherical RGP lenses. Methods: Spherical and aspherical RGP lenses were fitted with alignment in 77 subjects (135 eyes) who were in their 20~30s. Tear volume stained with fluorescein was qualitatively analyzed by dividing cornea into center, mid-peripheral and peripheral parts. Results: For the spherical RGP lens fitting, tear volume differences were found in each part in all corneal types. For the aspherical RGP lens fitting, tear volume differences were in each corneal part in symmetric bow tie- and asymmetric bow tie-type corneas. However, the tear was equally distributed from the center to the peripheral part in round- and oval-type corneas. In the group with corneal astigmatism lower than 1.25 D, tear volume between center and peripheral parts, and mid-peripheral and peripheral parts, was different when a spherical RGP lens was fitted. However, tear volume in each part was not different in the group with corneal astigmatism over 1.50 D. Moreover, the tear volumes of the central and mid-peripheral parts were proportionally increased with increasing corneal astigmatism in both spherical and aspherical RGP lenses. Furthermore, aspherical RGP lenses showed greater increments than spherical RGP lenses. Conclusions: The results revealed that the difference in tear volume between aspherical RGP lens and cornea was less than spherical RGP lens, and the difference in tear volume varied according to corneal shape and astigmatism. In addition, the method of measuring relative tear volume between RGP lens and cornea that was established in the present study can be used to evaluate tear volume between contact lens and cornea.

An Ultrastructral changes of the new-born rats and adult rat's cornea (신생 흰쥐와 성숙 흰쥐 각막의 미세구조 변화에 관한 연구)

  • Kim, Dae Nyoun;Kim, In Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.3 no.1
    • /
    • pp.93-101
    • /
    • 1998
  • The present study was conducted to investigate the structural changes in rat cornes. Sixty eyes from one-day-old uneyed rats, fourty eyes from 10-weeks-old adult rats were used. With the increase of age, the epithelial layer was thickened by the addition of new successive cellular layers. Then, the new-born rat's epithelial cells formed a pentagonal shape, and the quality of decidual cells showed a high electron-density, although the boundary between cells was distinctive. The newly produced cells showed a low electron-density so that there was the distinctive difference between light and darkness. In Bowman's layer, collagen fibrils demonstrate a regularly arranged structure along with the age. In stroma's layer, the density of keratocytes was decreased and thereby progressively flattened during the development. The collagenous layer of the adult rats was more distinctive than that of the new-born rats in a form of vertical and horizontal parallel alignment running vertically and horizontally. Descemet's membrane changed its structure significantly along with the age. It changed the shape from "banded-layer" to "non-banded layer" gradually. The thickness was also increased along with the age. Regardless of developmental stages, the endothelium is usually monolayer. During the developmental process, endothelial cells disappeared, so the density of endothelium was also decreased. The empty spaces were replaced by the expansion of adjacent cells.

  • PDF

Optical Approach for Increasing the Resolution of Displayed Multi-view Image from Projection Type of Auto-stereoscopic 3D Display System by Adopting a Commercial Spherical Lenticular Lens Sheet (프로젝션 기반 무안경 방식 멀티뷰 3D 디스플레이에서 구면 렌티큐라 렌즈 시트를 이용하여 재생된 입체영상의 해상도를 증가시키는 광학적 접근 방법)

  • Sohn, Young-Sub;Kim, Sung-Kyu;Sohn, Kwanghoon;Lee, Kwang-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.147-153
    • /
    • 2012
  • Multi-view 3D displays based on a limited number of pixels have the problem that the stereo-scopic image has a low resolution because of increasing view number. To solve the problem of low resolution, we propose an optical approaching method that focuses the width of a unit pixel by using a commercial spherical shape lenticular lens sheet and increases the effective resolution by increasing the number of sources of light in the multi-view 3D display system based on projection type. The method was performed in such an order that several main derivable parameters were defined, and, through the theoretical and experimental result, the value of the contractible unit pixel width and the scalable effective resolution was derived in a given system environment. As a result, for the case that the ray of light from the projector transmitted the 25 LPI lenticular lens sheet which has the pitch size 1.016 mm, the focused unit pixel width was 0.19 mm and the scalable effective resolution was, at most, 5 times wider than the original one. In addition, the range of depth of focus was 1.496 mm, which shows us the range of thickness tolerances of commercial spherical shape lenticular lens sheet and sufficient optical alignment tolerances.

Comparison of Cervical Hyeopcheok Acupoint's Depth Change with Cervical Rotation in a Prone Position: Protocol and Pilot Study Result for Accurate Observation of Cervical Hyeopcheok Acupoint by Ultrasonography (복와위에서 경추 회전 시 관찰되는 경추 협척혈의 심도 변화 비교: 초음파를 활용한 경추 협척혈 관찰 프로토콜 및 예비연구 결과)

  • Chu, Hongmin;Park, Kyungtae;Jang, Jongwon;Shin, Hee-Ra;Yang, Muhack;Kim, Doo Ri;Ryu, Won Hyung;Ryu, Ho-sun;Yeom, Seung-Ryong;Lee, Sangkwan;Kim, Cheol-hyun
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.29 no.4
    • /
    • pp.81-88
    • /
    • 2019
  • Objectives This study is a preliminary study for safe and accurate cervical Hyeopcheok acupuncture by comparing the depth of cervical Hyeopcheok acupoint with cervical spine rotation. Methods Researchers took ultrasonographic images of cervical Hyeopcheok acupoint during full rotation of cervical spine, 45 degree rotation and neutral condition in a prone position. 4 healthy volunteers were recruited. Results No significant difference in needling depth of cervical Hyeopcheok acupoint was observed. However, there were a differences in anatomical structures' shape such as muscles. Conclusions There are no significant difference in needling depth, but anatomical structures' shape were changed. This result mean that if patient rotate cervical spine during acupuncture treatment, it can occur complications. Thus, when acupuncture treatment on cervical Hyeopcheok acupoint, practioner should make subject's cervical spine alignment corrected and be careful not to change posture during the procedure.

Study on the Differences in the Results of Body Shape Test According to the Position of the Two Feet and the Usefulness of the Neck and Body Motion Image Test (두 발의 위치에 따른 체형검사 결과 차이와 체간신전 동작 이미지 검사의 유용성 연구)

  • Chang, Wan Song;Kim, Song Ja;Ryu, Seo Won;Lim, Duk Joon;Jung, Moon Young
    • Journal of Naturopathy
    • /
    • v.9 no.1
    • /
    • pp.22-26
    • /
    • 2020
  • Purposes: The purposes of this study were to investigate the relationship between the standing position of the subject and the normal standing position(NSP) and the straight standing position(SSP) and to investigate the possibility of different body shape test results depending on the status of the image inspection apparatus. Methods: The images of the NSP and SSP were compared with each other by body line BLS system. Results: At the time of examination, the position of the camera was captured at a position 2.3 m vertically from the posterior position 45 cm behind the subject. This is a privacy protection method for covering the breast of the subject. Results: The physiological characteristics of the anatomical position of the body align image test are the living body. NSP and SSP tests showed different shapes of the pelvis AS(antero-supero) and pelvis rotation in the transverse plane. Shoulder and arm displacement was observed in the trunk extension image capture. Conclusions: In the body alignment test, the pelvis position test images of NSP and SSP are evaluated differently for pelvis rotation, AS, and PS. At the extension position of the trunk, a test of the maximal extension range showed that the left and right shortening of the shoulder anterior muscles could be observed. Inducing and testing the trunk extension is also useful.

Improvement of the Uniformity of Temperature Distribution inside Semiconductor Test Equipment Chamber (반도체 검사 장비의 챔버 내부 온도 분포의 균일성 개선)

  • Lee, Kwang-Ju;Jeong, Kyung-Seok;Park, Sung-Mun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3626-3632
    • /
    • 2010
  • Some design changes were made to enhance the uniformity of temperature distribution inside the chamber of semiconductor test equipment. The design changes include the installation of adjustable airflow controller inside the chamber, the alignment of the centers of heater and match plate, the change in the size and the shape of holes in match plate base, and the addition of new holes of 2 mm diameter in order to allow airflow directly to the temperature sensors. In order to verify their effects, the temperature distributions inside the chambers were measured using 32 RTD sensors before and after the design changes. The temperature distributions were in the ranges of 87.1 to $91.5^{\circ}C$ ($90{\pm}2.9^{\circ}C$) and 89.5 to $90.8^{\circ}C$ ($90{\pm}0.8^{\circ}C$) before and after the design changes, respectively. The above temperature distribution after design changes was maintained for longer than 15 minutes, which satisfied the target temperature range of $90{\pm}1^{\circ}C$ for longer than 10 minutes.

The Overview of Layered structures in Mafic - Ultramafic Macheon Intrusion (고철질-초고철질 마천관입암의 층상구조 개관)

  • Song, Yong-Sun;Kim, Dong-Yeon;Park, Kye-Hun
    • The Journal of the Petrological Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.162-179
    • /
    • 2007
  • Macheon Layered Intrusion (MLI) which intruded into Precambrian gneiss complex of the northern Jirisan area, southeastern part of Youngnam (or Sobaeksan) Massif, is a layered mafic-ultramafic complex of Triassic age (ca. 223 Ma). The MLI is divided into Layered Series and Laminated Series. Layered Series is subdivided into Central Zone (Lower Zone) consisting of olivine gabbros and Peripheral Zone (Middle or Upper Zone) consisting of hornblende gabbros based on the type of cumulus texture and the main mafic phase. The Central Zone of Layered Series comprises thinly laminated olivine gabbros and uniform or thickly laminated coarse olivine gabbros which consist of mela-gabbro, troctolite, leuco-troctolite, and anorthositic rocks. Laminated Series is also subdivided into quartz-bearing biotite-pyroxene gabbros and homblende diorite and both have variable amount of interstitial quartz and microcline. Laminated series display moderately to slightly developed igneous lamination which is defined by the planar alignment of lath-shape plagioclases. Chilled margin of quartz-bearing biotite-pyroxene gabbro with surrounding Precambrian gneisses insists shallower intrusion of more felsic cognate magma evolved in the deep a little later. Rocks of Layered Series have orthocumulus to adcumulus olivine, adcumulus to intercumulus plagioclase, and intercumulus to heteradcumulus pyroxene and hornblende. Magmatic modally grading, folding, and cross-lamination are not rarely occurred in thinly layered rocks. These textural characteristics define main mechanisms of the formation of layered and laminated structure in mafic-ultramafic rocks of Macheon Layered Intrusion are gravity settling and in-situ crystallization associated with slumping and density current.

A Study on form of 'collar' in the China and Mongolian Traditional OverCoat & National Costume -Focusing on 13th Century's- (중국 및 몽고제국의 포제와 민족복에 나타난 ' 깃 (옷깃)'에 대한 연구 -13세기를 중심으로-)

  • 김은주
    • Journal of the Korean Society of Costume
    • /
    • v.19
    • /
    • pp.209-240
    • /
    • 1992
  • The costume of any nation is an attribute of a culture. This study concerns chinese and Mongolian costume's 'collar' form according to the observation of some reports about import folk materials and the pictures of the genuine objects, the author has investigated and rearranged them focusing on 13th Century's. 1. Traditional OverCoat or National costume on the poing of won dynasty in china such as Jacket, Coat, Mantle for making classical matching color, lacing, pearl pieces, and all costume shall be properly decorated and disigned. The example, Chinese Women's Gown and Double Jacket, on top of alignment of plaid, focus shall be placed on chinese classical form and color-matching, such as flowers and bireds, butterflies, made wishing ornaments, which shall be either hand painted or embroidered on collars, fronts, sleeves openings, and lower portion of gown. 2. Mongolian Costume, the stone status of a person, are seen at the territory of the Republic of Mongolia was a powerful country of Asia. So during the Mongolian Empire a lot of Missions from many countries came to kharakorom for establishing official relations between Mongolia and a country represented by mission. In particularly, the costume of mongols on the point of Chinggis khan Empire which the upper clothes in cluded ; a several kinds of the Caftan as compared with in Korea as to material (Silk caftan, Cotton Caftan, Fur Caftan) with closing to the right due to overlapping and Stand-up-Shawl Collars will pancho style & Round or V Neckline. 3. As compared with in Korea it is said that this a sort of Simui was brought in prior to the middle of Koryeo dynasty. Korean Simui system was complied with chinese system through confucian domestic behaviour. This was respected for court dress of confucian scholars, as it was, Chumri can ordinary dress of schloars) and Hakchangui ( a uniform of confucian student). Generally its form or shape of the outer lapels of Korean jacket were used together Squar-Tray-Collar. In late Yi-dynasty the inside collar length was longer than the outside collar length and the width of the collar was gradually narrow. And so the Traditional costume's outer collar of Jacket and OverCoat became small while the width and length of breast-tie became large. The same thing as the form of the collar on these days had been appeared by the design method or adjust one's dress. Therefore the form of collar in the china and Mongolian Traditional OverCoat & National Costume is fix arranged according to Stand up Collar, Without Collar, Clothing to the Right, Central opening, Horizontal Row of Button with Round or V Neckline and so on.

  • PDF