• Title/Summary/Keyword: Shallow thickness

Search Result 180, Processing Time 0.026 seconds

A Study of Tensile Strength in 18% Ni Maraging Steel Sheet Welded with Electron Beam (E.B 용접된 18% Ni 마르에이징강 박판의 인장이음강도에 관한 연구)

  • 정병호;김무길;김원녕
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.157-165
    • /
    • 1997
  • The strength level of welded joint in room temperature and elevated temperature up to $600^{\circ}C$ was investigated in 250 and 300 grade 18% Ni maraging steel sheet welded with electron beam. The results obtained in this study are as follows; 1. Optimum welding heat input was 600J/cm in 1.0mm thickness and the room temperature tensile strength, joint efficiency of welded joint treated with optimum aging condition were found to be about 166kg/$mm^2$, 95% in 250 grade, 189kg/$mm^2$, 92% in 300 grade maraging steel sheet, respectively. 2. Tensile strength of welded joint in room temperature increased slightly by aging after repeated solution heat treatment, but the fracture mode showed a shear. 3. Joint efficiency at a temperature between $540^{\circ}C$and $600^{\circ}C$ found to be about 72% to 55%, but the joint efficiency exceeded about 90% below $300^{\circ}C$. 4. The fracture occurred in most weld metal, and the fracture surface showed a shallow dimple.

  • PDF

Detection of Deep Subsurface Cracks in Thick Stainless Steel Plate

  • Kishore, M.B.;Park, D.G.;Jeong, J.R.;Kim, J.Y.;Jacobs, L.J.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.20 no.3
    • /
    • pp.312-316
    • /
    • 2015
  • Unlike conventional Eddy Current Test (ECT), Pulsed Eddy Current (PEC) uses a multiple-frequency current pulse through the excitation coil. In the present study, the detection of subsurface cracks using a specially designed probe that allows the detection of a deeper crack with a relatively small current density has been attempted using the PEC technique. The tested sample is a piece of 304 stainless steel (SS304) with a thickness of 30mm. Small electrical discharge machining (EDM) notches were put in the test sample at different depths from the surface to simulate the subsurface cracks in a pipe. The designed PEC probe consists of an excitation coil and a Hall sensor and can detect a subsurface crack as narrow and shallow as 0.2 mm wide and 2 mm deep. The maximum distance between the probe and the defect is 28 mm. The peak amplitude of the detected pulse is used to evaluate the cracks under the sample surface. In time domain analysis, the greater the crack depth the greater the peak amplitude of the detected pulse. The experimental results indicated that the proposed system has the potential to detect the subsurface cracks in stainless steel plates.

Cementing failure of the casing-cement-rock interfaces during hydraulic fracturing

  • Zhu, Hai Y.;Deng, Jin G.;Zhao, Jun;Zhao, Hu;Liu, Hai L.;Wang, Teng
    • Computers and Concrete
    • /
    • v.14 no.1
    • /
    • pp.91-107
    • /
    • 2014
  • Using the principle of damage mechanics, zero-thickness pore pressure cohesive elements (PPCE) are used to simulate the casing-cement interface (CCI) and cement-rock interface (CRI). The traction-separation law describes the emergence and propagation of the PPCE. Mohr-coulomb criteria determines the elastic and plastic condition of cement sheath and rock. The finite element model (FEM) of delamination fractures emergence and propagation along the casing-cement-rock (CCR) interfaces during hydraulic fracturing is established, and the emergence and propagation of fractures along the wellbore axial and circumferential direction are simulated. Regadless of the perforation angle (the angle between the perforation and the max. horizontal principle stress), mirco-annulus will be produced alonge the wellbore circumferential direction when the cementation strength of the CCI and the CRI is less than the rock tensile strength; the delamination fractures are hard to propagate along the horizontal wellbore axial direction; emergence and propagation of delamination fractures are most likely produced on the shallow formation when the in-situ stresses are lower; the failure mode of cement sheath in the deep well is mainly interfaces seperation and body damange caused by cement expansion and contraction, or pressure testing and well shut-in operations.

Petrochemical Study of the Gadaeri Granite in Ulsan Area, Kyeongsang Province (경상남도 울산지역 가대리화강암에 대한 암석화학적 연구)

  • Choi, Seon-Gyu;Wee, Soo-Meen
    • Economic and Environmental Geology
    • /
    • v.27 no.5
    • /
    • pp.459-467
    • /
    • 1994
  • The Gadaeri granite near Ulsan mine is an oval-shape isolated granitic body, and is genetically related to the iron-tungsten mineralization. The Gadaeri granite exhibits calc-alkaline and I-type characteristics, and generally shows the micrographic texture which indicates the shallow depth of emplacement. Consideration of the stratigraphic thickness of Ulsan formation and minimum-melt compositions suggests that the bulk magma crystallized at pressure of 0.5~2.0 kbar under water saturated condition. The evolutionary trend observed in the studied rocks represents that feldspar fractional crystallization has been a major magmatic process at the Gadaeri granite pluton. Different chemical characteristics between the Gadaeri and the Masan-Kimhae granites cannot be explained by fractional crystallization or different degrees of partial melting, and it reflects that the magma source for Gadaeri granite was different from that of the Masan and Kimhae granites.

  • PDF

An Amorphous Silicon Local Interconnection (ASLI) CMOS with Self-Aligned Source/Drain and Its Electrical Characteristics

  • Yoon, Yong-Sun;Baek, Kyu-Ha;Park, Jong-Moon;Nam, Kee-Soo
    • ETRI Journal
    • /
    • v.19 no.4
    • /
    • pp.402-413
    • /
    • 1997
  • A CMOS device which has an extended heavily-doped amorphous silicon source/drain layer on the field oxide and an amorphous silicon local interconnection (ASLI) layer in the self-aligned source/drain region has been studied. The ASLI layer has some important roles of the local interconnections from the extended source/drain to the bulk source/drain and the path of the dopant diffusion sources to the bulk. The junction depth and the area of the source/drain can be controlled easily by the ASLI layer thickness. The device in this paper not only has very small area of source/drain junctions, but has very shallow junction depths than those of the conventional CMOS device. An operating speed, however, is enhanced significantly compared with the conventional ones, because the junction capacitance of the source/drain is reduced remarkably due to the very small area of source/drain junctions. For a 71-stage unloaded CMOS ring oscillator, 128 ps/gate has been obtained at power supply voltage of 3.3V. Utilizing this proposed structure, a buried channel PMOS device for the deep submicron regime, known to be difficult to implement, can be fabricated easily.

  • PDF

The Fabrication of (Ga, Al) As/GaAs Modified Multi-Quantum Well Laser Diode by MOCVD (MOCVD법에 의한 (Ga, Al) As/GaAs 변형된 영지우물 레이저 다이오드의 제작)

  • Kim, Chung-Jin;Kang, Myung-Ku;Kim, Yong;Eom, Kyung-Sook;Min, Suk-Ki;Oh, Hwan-Sool
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.9
    • /
    • pp.36-45
    • /
    • 1992
  • The Modified Multi-Quantum Well(MMQWAl) structures have been grown by Mental-Organic chemical Vapor Deposition(MOCVD) method and stripe type MMQW laser diodes have been investigated. In the case of GaAs/AlGaAs superlattice and quantum well growth by MOCVD, the periodicity, interface abruptess, Al compositional uniformity and layer thickness have been confirmed though the shallow angle lapping technique, double crystal x-ray diffractometry (DCXD) and photoluminescence (PL) measurement. stripe-type MMQW laser diodes have been fabricated using the process technology of photolithography, chemical etching, ohmic contact, back side removing and cleaving. As the result of the electrical and opticalmeasurement of these laser diodes, we have achieved the series resistance of $1[\Omega}~2{\Omega}$ by current-voltage measurements, the threshold current of 200-300mA by currnt-light measurements and the lasing wavelength of 8000-8400$\AA$ by lasing spectrum measurements.

  • PDF

Survey of underwater deposits using ground penetrating radar (지표레이다 (GPR) 탐사에 의한 하상퇴적물 조사)

  • Chang, Hyun-Sam;Jeong, Seong-Tae
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.163-178
    • /
    • 2002
  • Investigation of underwater sedimentary layers has been carried out with GPR (Ground Penetration Radar) survey. GPR survey has been proved to be very satisfactory since the target area has shallow water depth of about 2.5 m, is lake with no water flow, and the thickness of mud layer, which is a main survey target, is relatively thin. The results clearly showed the underwater sedimentary layers, which includes mud, sand, gravel and basement layer. Specially, the distribution and total amount of mud layers from the survey, which is main target of removal, can be used as a basic data for the dredging of mud layer in the area.

  • PDF

Nanotopography Simulation of Shallow Trench Isolation Chemical Mechanical Polishing Using Nano Ceria Slurry (나노 세리아 슬러리를 이용한 STI CMP에서 나노토포그라피 시뮬레이션)

  • Kim, Min-Seok;Katoh, Takeo;Kang, Hyun-Goo;Park, Jea-Gun;Paik, Un-Gyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.239-242
    • /
    • 2004
  • We investigated the nanotopography impact on the post-chemical mechanical polishing (post-CMP) oxide thickness deviation(OTD) of ceria slurry with a surfactant. Not only the surfactant but also the slurry abrasive size influenced the nanotopography impact. The magnitude of the post-CMP OTD increased with adding the surfactant in the case of smaller abrasives, but it did not increase in the case of larger abrasives, while the magnitudes of the nanotopography heights are all similar. We created a one-dimensional numercal simulation of the nanotopography impact by taking account of the non-Prestonian behavior of the slurry, and good agreement with experiment results was obtained.

  • PDF

The measurement of nano properties using nanoindentation (나노인덴테이션을 이용한 나노물성 측정)

  • Kwon Dong-Il;Lee Kyung-Woo;Kim Sung-Hoon;Kim Ju-Young;Lee Yun-Hee
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.63-68
    • /
    • 2005
  • The nanoindentation technique is widely used to investigate the mechanical properties of nano-microscale materials. The nanoindentation method for assessing mechanical properties at low loads and shallow depths is already well established fur the characterization of thin films as well as bulk materials. In this study, we evaluated residual stress in DLC and Au thin films usign nanoindentation technique with a new stress-relaxation model. Moreover, We suggest a composite hardness equation and quantify the magnitude of hardness increase by using an equation based on the interface hardness and the interface thickness, derived by comparing results derived from this equation and those determined in nanoindentation tests. Finally, We present an indentation size effect (ISE) model that extends the available contact depth for ISE application down to several tens of nanometers by considering the tip bluntness effect.

  • PDF

A passive control on shock oscillations in a supersonic diffuser (초음속 디퓨져에서 발생하는 충격파 진도의 피동제어)

  • Kim, Heuy-Dong;Matsuo, Kazuyasu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.3
    • /
    • pp.1083-1095
    • /
    • 1996
  • Shock wave/boundary layer interaction frequently causes the shock wave to oscillate violently and thus the global flow field to unstabilize. In order to stabilize the shock wave system in the diffuser of a supersonic wind tunnel, the present study attempted to control the shock oscillations by using a passive control. A porous wall with the porosity of 19.6% was mounted on a shallow cavity. Experiment was made by means of schlieren optical observation and wall pressure measurements. The flow Mach number just upstream the shock system and Reynolds number based on the turbulent boundary layer thickness were 2.1 and 1.8 * 10$\^$6/, respectively. The results show that the present passive control method on the shock wave/boundary layer interaction in the supersonic diffuser can significantly suppress the oscillations of shock system, especially when the shock system locates at the porous wall.