• Title/Summary/Keyword: Shaking table

Search Result 603, Processing Time 0.025 seconds

Hysterisis Rules of RC member by Shaking Table Test (진동대 실험에 의한 RC부재의 이력거동)

  • Lee, Dae-Hyoung;Yang, Dong-Wook;Baek, Min-Chul;Hong, Hyun-Ki;Chung, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.9-10
    • /
    • 2009
  • The object of this research is to investigate the hysteresis rules of RC members by shaking table test. These hysteresis rules are essential to verify of safety under earthquake excitation. The effect of mass was investigated in stiffness of hysteresis rules.

  • PDF

진동대를 이용한 Geomembrane-Geotextile 사이의 동적 접촉마찰특성 평가

  • 김동진;서민우;박준범
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.179-182
    • /
    • 2002
  • Geosynthetics are widely used in landfill for filtration, drainage, separation and so on. For many landfill failure cases, interfaces of geosynthetics can be potential failure surfaces. Therefore, it is very Important to estimate the interface properties of geosynthetics. In this study, shaking table tests were peformed between smooth geomembrane and geotextile. From the test results, it was found that there is a limited acceleration that can be transmitted from smooth geomembrane to geotextile. And the influence of normal stress and frequencies of excitation were discussed.

  • PDF

A Study on the Dynamic Behaviour of Cut-and-Cover Tunnel by Shaking Table Test (진동대 실험을 이용한 개착식터널의 동적 거동특성에 관한 연구)

  • 정형식;조병완;이영남;이두화;이용준
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.173-180
    • /
    • 2001
  • This research is aimed at investigating the dynamic response of cut-and-cover tunnel to seismic waves. We carried out shaking table test which is used a 1/40-scale(the width of prototype tunnel is about 14.2m, the height is about 8.5m) model for this research, and we analyzed the effect of depth of tunnel and slope of the ground in relation to the dynamic responses of tunnel. As a result of the test, the stress and acceleration along the tunnel decreased accordingly to the depth of increment, and this phenomenon is caused by the increase of the confining effect of ground. Also, the dynamic responses of tunnel showed a tendency to rise according as ground declined gently. In comparison the result of shaking table test with that of structural analysis on ordinary condition, we conclude that seismic waves do not affect cut-and-cover tunnel when the depth of tunnel is over the diameter of tunnel.

  • PDF

Critical seismic incidence angle of transmission tower based on shaking table tests

  • Tian, Li;Dong, Xu;Pan, Haiyang;Gao, Guodong;Xin, Aiqiang
    • Structural Engineering and Mechanics
    • /
    • v.76 no.2
    • /
    • pp.251-267
    • /
    • 2020
  • Transmission tower-line systems have come to represent one of the most important infrastructures in today's society. Recent strong earthquakes revealed that transmission tower-line systems are vulnerable to earthquake excitations, and that ground motions may arrive at such structures from any direction during an earthquake event. Considering these premises, this paper presents experimental and numerical studies on the dynamic responses of a 1000 kV ultrahigh-voltage (UHV) transmission tower-line system under different seismic incidence angles. Specifically, a 1:25 reduced-scale experimental prototype model is designed and manufactured, and a series of shaking table tests are carried out. The influence of the seismic incidence angle on the dynamic structural response is discussed based on the experimental data. Additionally, the incidence angles corresponding to the maximum peak displacement of the top of the tower relative to the ground (referred to herein as the critical seismic incidence angles) are summarized. The experimental results demonstrate that seismic incidence angle has a significant influence on the dynamic responses of transmission tower-line systems. Subsequently, an approximation method is employed to orient the critical seismic incidence angle, and a corresponding finite element (FE) analysis is carried out. The angles obtained from the approximation method are compared with those acquired from the numerical simulation and shaking table tests, and good agreement is observed. The results demonstrate that the approximation method can properly predict the critical seismic incidence angles of transmission tower-line systems. This research enriches the available experimental data and provides a simple and convenient method to assess the seismic performance of UHV transmission systems.

Seismic performance evaluation of circular composite columns by shaking table test (진동대 실험을 통한 원형 합성 기둥의 내진 성능 평가)

  • Shim, Chang-Su;Chung, Young-Soo;Park, Ji-Ho;Park, Chang-Young
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.71-81
    • /
    • 2007
  • For the design of composite bridge piers, detail requirements for the reinforcements is not clear to satisfy the required seismic performance. Composite bridge piers were suggested to reduce the sectional dimensions and to enhance the ductility of the columns under earthquake loadings. In this paper, five specimens of concrete encased composite columns of 400mm diameter with single core steel were fabricated to investigate the seismic performance of the composite columns. Shaking table tests and a Pseudo-Dynamic test were carried out and structural behavior of small-scaled models considering near-fault motions was evaluated. Test parameters were the pace of the transverse reinforcement, lap splice of longitudinal reinforcement and encased steel member sections. The displacement ductility from shaking table tests was lower than that from the pseudo-dynamic test. Limited ductile design and 50% lap splice of longitudinal reinforcement reduced the displacement ductility. Steel ratio showed significant effect on the ultimate strength. Lap splice and low transverse reinforcements reduced the displacement capacity. The energy dissipation capacity of composite columns did not show significant difference according to details.

A Study on Seismic Retrofit Design of the Stabilized Piles by 1g Shaking Table Tests and Pseudo-static Analysis (1g 진동대 실험 및 등가정적해석을 이용한 억지말뚝의 사면안정 내진보강 효과 연구)

  • Han, Jin-Tae;Cho, Jong-Suck;Yoo, Min-Taek;Lee, Seung-Hyun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.2
    • /
    • pp.93-101
    • /
    • 2011
  • Korea has about 70% of its land classified as the mountain area, which has led to cut-slope being the result of substantial road and railway construction. However, there is currently a lack of research about the seismic retrofit design of a slope, even though many earthquakes have recently occurred at home and abroad. In this study, in order to investigate the stabilizing effect of piles against sliding during an earthquake, a series of 1 g shaking table tests and pseudo-static analyses were carried out. As a result, the stabilizing effect of piles against sliding during an earthquake was verified by the 1 g shaking table tests and the most effective result from the pseudo-static analyses was that the installation of the piles on the central part of the slope, where the failure surface included piles unlike the lower part and upper part of the slope. Furthermore, when the pile was installed on the central part of the slope, the change of the safety factor depending on the distance between the center of two piles was evaluated.

Analysis on the Dynamic Behavior of Breakwater with the DCM Method Using the Shaking Table Test (진동대시험을 이용한 DCM공법에 따른 방파제의 동적거동 분석)

  • Kim, Youngjun;Park, Innjoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.5
    • /
    • pp.25-32
    • /
    • 2022
  • As recently, there have been two earthquakes with a magnitude of 5.0 or greater in Korea and the number of smaller earthquakes has increased, a lot of research and interest in earthquake-resistant design are increasing. Especially, the Pohang earthquake has also raised interest in earthquake-resistant design of port facilities. In this study, experiments and analysis were conducted on the dynamic behavior of upright and inclined breakwaters during earthquakes among port structures through the 1g shaking table test. To this end, three seismic waves were applied to the model to which the similarity law (scale effect) was applied: long period (Hachinohe), short period (Ofunato) and artificial seismic waves. The acceleration and displacement of the upright and inclined breakwaters were analyzed according to whether the DCM method was reinforced during earthquakes based on the results of shaking table test. As the result, the dynamic behavior of the upright and inclined breakwater shows a tendency to suppress the amplification of acceleration as bearing capacity and rigidity increase when DCM method is reinforced.

Quasi-Static and Shaking Table Tests of Precast Concrete Structures Utilizing Clamped Mechanical Splice (가압고정 기계적이음을 활용한 프리캐스트 콘크리트 구조물의 준정적 및 진동대 실험)

  • Sung, Han Suk;Ahn, Seong Ryong;Park, Si Young;Kang, Thomas H.-K.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.37-47
    • /
    • 2023
  • A new clamped mechanical splice system was proposed to develop structural performance and constructability for precast concrete connections. The proposed mechanical splice resists external loading immediately after the engagement. The mechanical splices applicable for both large-scale rebars for plants and small-scale rebars for buildings were developed with the same design concept. Quasi-static lateral cyclic loading tests were conducted with reinforced and precast concrete members to verify the seismic performance. Also, shaking table tests with three types of seismic wave excitation, 1) random wave with white noise, 2) the 2016 Gyeongju earthquake, and 3) the 1999 Chi-Chi earthquake, were conducted to confirm the dynamic performance. All tests were performed with real-scale concrete specimens. Sensors measured the lateral load, acceleration, displacement, crack pattern, and secant system stiffness, and energy dissipation was determined by lateral load-displacement relation. As a result, the precast specimen provided the emulative performance with RC. In the shaking table tests, PC frames' maximum acceleration and displacement response were amplified 1.57 - 2.85 and 2.20 - 2.92 times compared to the ground motions. The precast specimens utilizing clamped mechanical splice showed ductile behavior with energy dissipation capacity against strong motion earthquakes.

A Study on the Analysis of the Fracture Behavior of Pallet Racks due to Earthquake Load (지진하중으로 인한 팔레트 랙의 파괴 거동 분석에 관한 연구)

  • Kim, Chunggil;Heo, Gwanghee;Jeong, Seonghoon;Kim, Sun Tae;Seo, Youngdeuk;Ko, Byeongchan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.157-164
    • /
    • 2023
  • This study aims to analyze the damage and destruction behavior of pallet racks due to external forces through shaking table test. Pallet racks is a general storage racks type consisting of column, beam, and brace to resist an external force. To analyze the safety of the pallet racks due to external force, a shaking table test was conducted to investigate the pallet racks behavior due to external force while increasing the seismic load targeting the pallet racks used in the existing logistics storage facility. As a result of the shaking table test, it was confirmed that the torsion of the pallet racks damaged the connection parts of some members located on the 1st and 2nd levels, thereby destroying the loading equipment.

Evaluation of Seismic Performance of Valve Chamber System by Shaking Table Tests (진동대 실험을 통한 밸브실 시스템의 내진성능 평가)

  • Young-Soo Jeong;Kyeong-Seok Lee;Jin-Seok Yu;Hyung-Chae Jeong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.1
    • /
    • pp.46-52
    • /
    • 2024
  • The structural safety of expansion joints for piping systems has been drawing attention owing to ruptures and leaks of water pipes caused by earthquakes and road subsidence at soft ground. In general, metal bellows are installed as expansion joints to prevent various damages in the piping system. In this study, the seismic performance of a valve chamber system was evaluated by performing earthquake shaking table tests. To validate the benefits to structural safety of metal bellows in connecting steel pipes to valve chambers, the seismic tests were conducted on expansion joints (bellows) and general pipping, and the results were compared for durability. Strain gauges were attached to measure the effects of the input motion. As a result of the shaking table test, it was confirmed that the strain of the valve chamber structure and inflow or outflow steel pipes were decreased in 1/100, 1/20 by applied to the expansion joints.