• 제목/요약/키워드: Shaft Current

검색결과 159건 처리시간 0.028초

개선된 등가 파라미터를 이용한 인버터 구동 유도전동기의 축전류 해석에 관한 연구 (A Study on Analysis of Inverter-fed Induction Motor's Bearing Current using Improved Equivalent Ciruit Parameters)

  • 김병택;구대현;홍정표;권병일;전지훈
    • 전기학회논문지
    • /
    • 제56권4호
    • /
    • pp.683-692
    • /
    • 2007
  • An inverter driven induction motor has more superior dynamic characteristic than sine wave driven induction motor. But it has a problem with shaft voltage and bearing current in drive-motor system. This paper presents the analysis of bearing current in inverter-fed induction motor. The proposed method is based on using numerical method (FEM) to derive parasitic parameters in motor. Using the electric field analysis with FEM, the stored energy in dielectric materials of the motor can be calculated and the parasitic capacitances are obtained. Then we compared the proposed method with a conventional method in variable frequency and load conditions. From the comparision of simulation and experiment result, we confirmed that the proposed method is valid.

Control Design of the Brushless Doubly-Fed Machines for Stand-Alone VSCF Ship Shaft Generator Systems

  • Liu, Yi;Ai, Wu;Chen, Bing;Chen, Ke
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.259-267
    • /
    • 2016
  • This paper presents a stand-alone variable speed constant frequency (VSCF) ship shaft generator system based on a brushless doubly-fed machine (BDFM). In this system, the output voltage amplitude and frequency of the BDFM are kept constant under a variable rotor speed and load by utilizing a well-designed current vector controller to regulate the control winding (CW) current. The control scheme is proposed, and the hardware design for the control system is developed. The proposed generator system is tested on a 325 TEU container vessel, and the test results show the good dynamic performance of the CW current vector controller and the whole control system. A harmonic analysis of the output voltage and a fuel consumption analysis of the generator system are also implemented. Finally, the total efficiency of the generator system is presented under different rotor speeds and load conditions.

Analysis of queuing mine-cars affecting shaft station radon concentrations in Quzhou uranium mine, eastern China

  • Hong, Changshou;Zhao, Guoyan;Li, Xiangyang
    • Nuclear Engineering and Technology
    • /
    • 제50권3호
    • /
    • pp.453-461
    • /
    • 2018
  • Shaft stations of underground uranium mines in China are not only utilized as waiting space for loaded mine-cars queuing to be hoisted but also as the principal channel for fresh air taken to working places. Therefore, assessment of how mine-car queuing processes affect shaft station radon concentration was carried out. Queuing network of mine-cars has been analyzed in an underground uranium mine, located in Quzhou, Zhejiang province of Eastern China. On the basis of mathematical analysis of the queue network, a MATLAB-based quasi-random number generating program utilizing Monte-Carlo methods was worked out. Extensive simulations were then implemented via MATALB operating on a DELL PC. Thereafter, theoretical calculations and field measurements of shaft station radon concentrations for several working conditions were performed. The queuing performance measures of interest, like average queuing length and waiting time, were found to be significantly affected by the utilization rate (positively correlated). However, even with respect to the "worst case", the shaft station radon concentration was always lower than $200Bq/m^3$. The model predictions were compared with the measuring results, and a satisfactory agreement was noted. Under current working conditions, queuing-induced variations of shaft station radon concentration of the study mine are not remarkable.

마이크로 가스터빈의 탈설계 운전 성능특성 (Performance Characteristics for Off-design Operation of Micro Gas Turbines)

  • 김동섭;황성훈
    • 한국유체기계학회 논문집
    • /
    • 제7권3호
    • /
    • pp.39-47
    • /
    • 2004
  • Micro gas turbines are designed with low turbine inlet temperature and pressure ratio. To overcome the efficiency defect of the simple cycle, adoption of the recuperator is an inevitable choice. In addition to the design performance, we should also pay attention to the off-design performance of gas turbines since they usually operate at part-load conditions lot a considerable amount of their lifetime. This study analyzes off-design performance characteristics of micro gas turbines and addresses the importance of the recuperation process doting the part load operation. Comparative analyses have been performed to evaluate the part load performance differences among various design and operating options : simple vs recuperative cycles, single vs two shaft configurations, various operating strategies for the single shaft configuration, and current vs advanced engines. Major finding is that maintaining high turbine exhaust temperature is crucial for efficient operation of micro gas turbines.

마이크로 가스터빈의 탈설계 운전 성능특성 (Performance Characteristics for Off-design Operation of Micro Gas Turbines)

  • 황성훈;김동섭
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.80-87
    • /
    • 2003
  • Micro gas turbines are designed with low turbine inlet temperature and pressure ratio. To overcome the efficiency defect of the simple cycle, adoption of the recuperator is an inevitable choice. In addition to the design performance, we should also pay attention to the off-design performance of gas turbines since they usually operate at part-load conditions for a considerable amount of the time. This study aims at analyzing off-design performance characteristics of micro gas turbines and addressing the importance of the recuperator in the part load operation. Comparative analyses have been performed to evaluate the part load performance differences among various design and operating options : simple vs recuperative cycles, single vs two shaft configurations, various operating strategies for the single shaft configuration (fuel only control, variable speed operation, variable inlet guide vane control), and current vs advanced engines. Major finding is that maintaining turbine at high level is crucial in efficient operation of micro gas turbines.

  • PDF

A Novel Claw Pole Eddy Current Load for Testing a DC Counter Rotating Motor Part I: Construction

  • Kanzi, Khalil;Dehafarin, Abolfazl;Roozbehani, Sam;Kanzi, Majid;Vasheghani, Qasem
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.321-329
    • /
    • 2012
  • Providing variable load for testing a motor in high speed conditions is usually a difficult task. The eddy current brake can be used in application of load testing of motors. This paper deals with construction of a novel claw pole eddy current brake which is employed as a load for a DC counter rotating motor (CRM). These kinds of motors have two inner and outer shafts that rotate in opposite directions simultaneously, which are particularly suitable for under water propulsion systems. The prototype 45KW eddy current brake consists of two parts. One of them is installed on the inner shaft of the 60KW DC CRM and the other one is installed on its outer shaft. The simulation and experimental results with prototype brakes are also analyzed by using MATLAB/Simulink and the operational characteristic of the brake is demonstrated as a function of the motor speed and current of the magnetic poles.

Unity Power Factor Control of Sensorless Switched Reluctance Motor

  • Jeyakumar, A. Ebenezer;Shanmuganandan, K.J.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1147-1152
    • /
    • 2004
  • Switched Reluctance Motors have an inexpensive, intrinsic simplicity and low cost that makes them well suited to home appliance and office applications. However the motor suffering with necessity of shaft position sensor, lead to non-linearity of operations. Further, the involvement of static converters deteriorates the operational power factor. Implementation of a sensorless algorithm, can remove the need of position sensors. Also, the drive includes a compact power factor control in the input stage by implementing Zero Current Switching Quasi-Resonant Boost Technology. This paper presented, aims at optimized low line current distortion, high power factor, low cost and a shaft position sensorless Switched Reluctance Motor drive.

  • PDF

고효율 영구자석 여자기 구조의 발전기 설계와 전압제어 (A Design and Voltage Control of a High Efficiency Generator with PM Exciter)

  • 조영준;이동희
    • 전기학회논문지
    • /
    • 제65권11호
    • /
    • pp.1827-1834
    • /
    • 2016
  • This paper presents a high efficient generator with PM(Permanent Magnet) exciter. The proposed PM exciter for the generator can produce a linear output voltage according to the engine speed. This output voltage is directly used to control the field current of the generator to adjust the generator output voltage. In the proposed generator system, since the field winding current can be supplied by the PM exciter, the generator can self-start without any battery or an external power supply due to the low residential flux. Furthermore, the operating efficiency of the generator is higher than a conventional winding exciter. The main problem of the proposed generator system, the field winding current controller has to be embedded inside the generator, and it rotates according to the generator shaft. In this paper, the proper embedded current controller is designed for the proposed generator system. Due to the embedded controller cannot be connected to the outside the generator controller, the measured instantaneous output voltage of the generator is transferred by the photo isolated communication using shaft aligned infrared transmitter and receiver to keep the constant generator output voltage. In this paper, 10kW, 380V engine generator with PM exciter and the embedded DAVR(Digital Automatic Voltage Regulator) are described. The proposed high efficiency generator is simulated and tested to verify the effectiveness.

이상상태 발생 시 선박용 추진전동기 및 추진축의 과도상태 해석 (Transient analysis of marine propulsion motor and shaft under abnormal conditions)

  • 오세진;김종수;김성환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권1호
    • /
    • pp.34-38
    • /
    • 2016
  • 최근 추진 전동기가 장착된 전기추진 시스템의 대형 크루즈 선박 및 상선이 점차 증가하는 추세이다. 이러한 전기추진 선박에서 추진 전동기에 이상상태가 발생하면 전동기 자체 및 프로펠러축에 심각한 손상이 발생할 수 있다. 하지만 전기추진 선박에 사용되는 추진 전동기의 정상상태 운전 및 이상상태 시의 분석에 관한 연구는 찾아보기 힘들고 관련 정보도 매우 부족한 실정이다. 본 연구에서는 전기추진 선박용 추진 시스템의 수학적 모델을 제시하고 이를 바탕으로 전기적인 이상상태 발생 시에 추진 전동기 및 프로펠러축에 발생하는 과도현상을 해석하고자 한다. 본 연구에 사용된 전기추진 선박용 전동기는 동기전동기이며 소프트웨어인 Matlab을 사용하여 모의실험을 수행하였으며, 정격으로 운전 중인 추진 전동기에 이상상태가 발생하였을 경우 과도전류는 1상 접지 상태에서 가장 크게 발생하며 추진축에 발생하는 과도토크는 3상 접지 및 2상 접지 상태에서 상대적으로 크게 발생하였고, 정격으로 운전 중 추진 전동기의 여자전력이 차단될 경우에도 과도전류와 과도토크가 비교적 크게 발생함을 확인하였다.