• 제목/요약/키워드: Shading devices

Search Result 54, Processing Time 0.038 seconds

A study of Illumination on Floor Surface by Flat Form Louver of Top Lighting System (천창루버에 의한 내부공간 바닥면 조도변화와 설치방식에 관한 연구)

  • Kim, Mi-Hee;Tae, Won-Jin
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.6
    • /
    • pp.132-138
    • /
    • 2011
  • Inducing the natural lighting into building has been commonly applied to the spaces where artistic objects are displayed to create better visual environment for the appreciation. The direct natural lighting, especially through top lighting system may, however, bring forth discoloing of highly light-sensitive materials such as paintings or demanding additional cooling load. In addition, it causes to create glare against appreciators or to yield in visual distraction due to the extreme contrast on the inner surfaces of the spaces. Shading device such as louver is capable of preventing such voidable cases with careful manipulation. This study aims to provide basic design guide-line when the flat-form louver has to be applied to top lighting system. Interaction between the daylight and louver was simulated by Reluxpro program with variation of the attachment location, the angle of the lover, surface reflectivity, to obtain the illumination of the floor surface. This study yields the louver just under the top lighting window with 90 degree angle gives the most desirable way of employment when the uniform illumination on the floor surface is required.

A Experiment Study on Performance Evaluation of Solar Heat Gain Coefficient in Glazing with Shading Devices (실내 차양장치 결합형 창호의 태양열 취득률 평가에 대한 실험적 연구)

  • Kim, Tae-Jung;Kang, Jae-Sik;Park, Jun-Seok
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.89-99
    • /
    • 2014
  • The determination of the solar and thermal performance of fenestration is required for the evaluation of fenestration energy performance, estimating building load. Presently, there exist several methods for determining the thermal transmission(U-value) and solar heat gain coefficient (SHGC) of fenestration system. These method are commonly grouped under calculation or experimental methods. While U-value testing and calculation methods have been long established, SHGC has been evaluated only by the method of calculation under the lack of any established testing method. However, it is difficult to assess the exact SHGC for various types of fenestration with sun-shading or other solar control systems. The purpose of this study was to evaluate the effect of interior venetian blind and roll screen on the SHGC of glazing system. SHGC has been evaluated by the KS L 9107 test method and exiting calculation method for precise comparison of the energy performances of various shading devices. In this research, the test sample consists of three different types of double glazing unit with venetian blind and roll screen. Slat angles of venetian blind were changed to $-45^{\circ}$, $0^{\circ}$, and$-45^{\circ}$. For the roll screen, measurements were taken with the roll screen in the closed position. In result, the venetian blind reduced SHGC by 21.2~28.4% at $45^{\circ}$, when compared to the double glazing unit. The roll screen reduced SHGC by 34.4~41.7% at closed. The differences between the measured and calculated SHGC were found to range between 0.001(0.2%) and 0.047(11.1%) for all test cases. For the cases of venetian blind $-45^{\circ}$, $0^{\circ}$ and $45^{\circ}$, the deviation ratio were 3.6~9.8%, 1.1~2.6%, 4.2~11.1%, respectively. For the case of roll screen, the deviation ratio were 4.1~5.7%.

Economic Probation on the Benefit of Daylighting by a Light-Guide System (생애주기비용분석 기법을 이용한 채광기능성 창호시스템의 경제성 평가에 관한 연구)

  • Kim, Gon;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.11-18
    • /
    • 2006
  • Attention on daylighting should be focused not so much on a simple maximization of the natural light available in a space, as on improving the quality of lighting by ensuring as even but intense distribution of illumination in inner areas. An architectural means of optimal daylight distribution is by using so-called light shelf systems, horizontal shading and redirecting devices. The overall performance of the daylighting system can be improved by the incorporation with electric lighting control devices. This paper aims to exemplify the benefit of daylighting in term of economic consideration. In such a case a reasonable technique to compare system costs is by life-cycle costing. Stated simply, a life-cycle cost represents the total cost of a system over its entire life cycle, that is, the sum of first cost and all future costs. Four different electric lighting system designs are proposed and a lighting control system that is continuously operating according to the level of daylight in the space has been adapted. The result shows clearly that although denser layout of lighting fixtures might be more effective to interface to the level of daylight ceaselessly changeable, its economic benefit may not meet the expected criterion the reason of increased initial investment and maintenance cost for the fixtures and control devices.

Improvement of sound insulation performance of windows according to the specifications of the external electric blinds (외부 전동블라인드의 사양에 따른 창호 차음성능 개선 효과)

  • Min-Woo, Kang;Hee-Dong, Lee;Yang-Ki, Oh
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.6
    • /
    • pp.621-628
    • /
    • 2022
  • The most realistic way to reduce noise outside the building, such as road traffic noise and aircraft noise, is to strengthen the sound insulation performance at the sound collecting points such as balconies, windows, and exterior walls of each building. However, in light of the reality that shading devices outside buildings are not yet widely used, there are not many studies on sound insulation performance improvement using external windows and window devices such as louvers and blinds. In particular, external blinds can not only block the inflow of strong sunlight in the morning and evening from the outside of the building, but also target the sound insulation effect that blocks the peak noise that occurs during commuting hours. In this study, a study was conducted to improve sound insulation performance against external noise by using an external electric blind (EEB), which is one of the most efficient window and door external shading devices. Various sound insulation performance tests were conducted while changing the configuration of external electric blinds developed for light blocking purposes. Through this, it was verified that an additional sound insulation performance of 6 dB can be obtained by installing an external electric blind compared to the reduction performance of general windows.

A Study on the Architectural Characteristics of ¡?Verbena Heights¡?Estate in Hong Kong (홍콩 버비나하이츠(Verbena Heights) 주거단지의 특징에 관한 연구)

  • 이재훈;김남응;김성화
    • Journal of the Korean housing association
    • /
    • v.13 no.3
    • /
    • pp.21-31
    • /
    • 2002
  • The purpose of this study is to find the architectural characteristics of Verbena Heights, super high-rise complex housing, which has been most highly evaluated as a new town development model in Hong Kong, as a successful case of new housing type and sustainable design. The analyzed features of Verbena Heights are as follows; 1) Formation of various open spaces by a creative layout. 2) Enhancement of natural ventilation and daylighting by a linear plan instead of conventional cruciform plans. 3) Applications of integrated facade design for noise mitigation and for sunlight shading. 4) Adoption of energy-efficient devices, use of recyclable materials, and improvement of livability by a sustainable design process. These architectural characteristics provide the high-density high-rise housing with more efficient and comfortable environments for residents. And it is proved that the sustainable design can enhance the quality of dwelling environment.

Users Defined Shading Method in Mobile Devices for Artistic Expressions (모바일 기기에서의 회화적 표현을 위한 사용자 정의 쉐이딩)

  • Jang Hyun-Ho;Jeon Jae-Woong;Hyun Chang-Won;Choy Yoon-Chul
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.06a
    • /
    • pp.112-114
    • /
    • 2006
  • 기존의 컴퓨터 그래픽이 추구하던 사실적 모사와는 다른 비사실적 기법(Non-Photorealistic Rendering)을 3차원 그래픽에 적용함으로써 사용자에게 보다 원활한 커뮤니케이션을 제공할 수 있게 되었다. 이러한 NPR 기법 중 카툰 렌더링은 사용자에게 친숙한 환경을 제시함으로써 수용자가 관련 컨텐츠에 집중을 할 수 있도록 해 많은 분야에서 사용되고 있는 실정이다. 특히 NPR 기법을 최근 증가하고 있는 모바일 컨텐츠에 적용하는 연구들도 활발히 진행되고 있다. 그러나 기존 모바일 연구에서의 연구는 전처리를 위한 카툰 렌더링 처리 정도 밖에 없었다. 본 논문은 모바일 기기에서의 사용자 정의에 의한 쉐이딩 기법 구현을 위해, 모바일 NPR 전처리 파일 대체 기법과 음영 단계를 위한 역학적 기법을 제안한다. 이 기법을 사용함으로써 사용자는 자신의 선호도에 따라 3D 모델을 보다 예술적으로 표현할 수 있어 다양한 모바일 분야에 적용이 가능하게 된다.

  • PDF

Optimum Automated Control Strategies of Inside Slat-type Blind considering Visual Comport and Building Energy Performance (재실자의 시쾌적과 건물에너지성능을 고려한 슬랫형 블라인드 자동제어전략)

  • Oh, Myung-Hwan;Yoon, Jong-Ho;Shin, U-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.187-195
    • /
    • 2011
  • Glass Envelope is vulnerable to insulation performance and controling solar radiation. Insulation performance is consistently improving these days due to recent building energy saving policy in South Korea. However, solar control at glass envelope is still limited to meeting requirements of ideal high performance. Generally, Inside Blind plays an important role of solar control instead of glass which have a characteristics of transmitted solar. Unfortunately, most of them are controled by occupants and which method is not resonable in building energy. Therefore, achieving the high efficient performance building, automated control blind system considering reduction of building loads have to be adopted. Furthermore, considering occupants visual comport about removing discomfort glare is also essential.

  • PDF

Performance characteristics of building-integrated transparent amorphous silicon PV system for a daylighting application (자연채광용 박막 투광형 BIPV 창호의 발전특성 분석 연구)

  • Yoon, Jong-Ho;Kim, Seok-Ge;Song, Jong-Wha;Lee, Sung-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.280-283
    • /
    • 2007
  • The first grid-connected, building-integrated transparent amorphous silicon photovoltaic installation has been operated since October 2004 in Yongin, Korea. The 2.2kWp transparent PV system was applied to the facade of entrance hall in newly constructed KOLON E&C R&D building. The PV module is a nominal 0.98m ${\times}$ 0.95m, 10% transparent, laminated, amorphous(a-Si) thin-film device rated at 44 Wp per module. To demonstrate the architectural features of thin film PV technologies for daylighting application, transparent PV modules are attached to the building envelope with the form of single glazed window and special point glazing(SPG) frames. Besides power generation, the 10% transmittance of a-Si PV module provides very smooth natural daylight to the entrance hall without any special shading devices for whole year. The installation is fully instrumented and is continuously monitored in order to allow the performance assessment of amorphous silicon PV operating at the prevailing conditions. This paper presents measured power performance data from the first 12 months of operation. For the first year, annual average system specific yield was just 486.4kWh/kWp/year which is almost half of typical amorphous silicon PV output under the best angle and orientation. It should be caused by building orientation and self-shading of adjacent mass. Besides annual power output, various statistical analysis was performed to identify the characteristics of transparent thin film PV system.

  • PDF

Case Studies on Space Zoning and Passive Façade Strategies for Green Laboratories

  • Kim, Jinho
    • Architectural research
    • /
    • v.22 no.2
    • /
    • pp.41-52
    • /
    • 2020
  • Laboratory buildings with specialized equipment and ventilation systems pose challenges in terms of efficient energy use and initial construction costs. Additionally, lab spaces should have flexible and efficient layouts and provide a comfortable indoor research environment. Therefore, this study aims to identify the correlation between the facade of a building and its interior layout from case studies of energy-efficient research labs and to propose passive energy design strategies for the establishment of an optimal research environment. The case studies in this paper were selected from the American Institute of Architects Committee on the Environment Top Ten Projects and Leadership in Energy and Environmental Design (LEED) certified research lab projects. In this paper, the passive design strategies of space zoning, façade design devices to control heating and cooling loads were analyzed. Additionally, the relationships between these strategies and the interior lab layouts, lab support spaces, offices, and circulation areas were examined. The following four conclusions were drawn from the analysis of various cases: 1) space zoning for grouping areas with similar energy requirements is performed to concentrate similar heating and cooling demands to simplify the HVAC loads. 2) Public areas such as corridor, atrium, or courtyard can serve as buffer zones that employ passive solar design to minimize the mechanical energy load. 3) A balanced window-to-wall ratio (WWR), exterior shading devices, and natural ventilation systems are applied according to the space programming energy requirements to minimize the dependence on mechanical service. 4) Lastly, typical laboratory space zoning categories can be revised, reversed, and even reconfigured to minimize the energy load and adjust to the site context. This study can provide deep insights into various design strategies employed for construction of green laboratories along with intuitive arrangement of various building components such as laboratory spaces, lab support spaces, office spaces, and common public areas. The key findings of this study can contribute towards creating improved designs of laboratory facilities with reduced carbon footprint and greenhouse emissions.

A Study on Micro-Converter of Photovoltaic System for Efficiency Progress (태양광발전시스템의 효율 향상을 위한 마이크로컨버터에 관한 연구)

  • Chae, Young-Kee;Lim, Jung-Yeol
    • Journal of IKEEE
    • /
    • v.18 no.1
    • /
    • pp.159-164
    • /
    • 2014
  • This paper targets the development of micro-converter such as a power converter for photovoltaic module. In corresponding to the poor performance of centralized PV system under partial shading, the power converter for single PV module to maximize the energy harvest from PV module. The power converter is constantly tracking the maximum power point of photovoltaic system and increases energy output power. To minimize the quantity of devices and switchs, 320W solar micro-converter is developed using synchronous rectifier. From the basis of these results, through simulations and experiments were verified efficiency.